期刊文献+
共找到11,302篇文章
< 1 2 250 >
每页显示 20 50 100
Deep learning-assisted common temperature measurement based on visible light imaging
1
作者 朱佳仪 何志民 +8 位作者 黄成 曾峻 林惠川 陈福昌 余超群 李燕 张永涛 陈焕庭 蒲继雄 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期230-236,共7页
Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This pap... Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This paper proposes an alternative approach of extracting temperature information in real time from the visible light images of the monitoring target using a convolutional neural network(CNN).A mean-square error of<1.119℃was reached in the temperature measurements of low to medium range using the CNN and the visible light images.Imaging angle and imaging distance do not affect the temperature detection using visible optical images by the CNN.Moreover,the CNN has a certain illuminance generalization ability capable of detection temperature information from the images which were collected under different illuminance and were not used for training.Compared to the conventional machine learning algorithms mentioned in the recent literatures,this real-time,contact-free temperature measurement approach that does not require any further image processing operations facilitates temperature monitoring applications in the industrial and civil fields. 展开更多
关键词 convolutional neural network visible light image temperature measurement low-to-medium-range temperatures
下载PDF
Design of weak current measurement system and research on temperature impact
2
作者 Chu-Xiang Zhao San-Gang Li +8 位作者 Rong-Rong Su Li Yang Ming-Zhe Liu Qing-Yue Xue Shan Liao Zhi Zhou Qing-Shan Tan Xian-Guo Tuo Yi Cheng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期46-56,共11页
A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filterin... A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents. 展开更多
关键词 Weak current measurement system Neutron ionization chamber Kalman filter algorithm temperature correction model
下载PDF
The influences of canopy temperature measuring on the derived crop water stress index
3
作者 WANG Hongxi LI Fei +4 位作者 SHEN Hongtao LI Mengyu YIN Gongchao FANG Qin SHAO Liwei 《中国生态农业学报(中英文)》 CAS CSCD 北大核心 2024年第9期1503-1519,共17页
Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the... Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the influences of atmospheric conditions,settled height,view angle of infrared thermography,and investigating time of temperature measuring on the performance of the CWSI.Three irrigation treatments were used to create different soil water conditions during the 2020-2021 and 2021-2022 winter wheat-growing seasons.The CWSI was calculated using the CWSI-E(an empirical approach)and CWSI-T(a theoretical approach)based on the T_(c).Weather conditions were recorded continuously throughout the experimental period.The results showed that atmospheric conditions influenced the estimation of the CWSI;when the vapor pressure deficit(VPD)was>2000 Pa,the estimated CWSI was related to soil water conditions.The height of the installed infrared thermograph influenced the T_(c)values,and the differences among the T_(c)values measured at height of 3,5,and 10 m was smaller in the afternoon than in the morning.However,the lens of the thermometer facing south recorded a higher T_(c)than those facing east or north,especially at a low height,indicating that the direction of the thermometer had a significant influence on T_(c).There was a large variation in CWSI derived at different times of the day,and the midday measurements(12:00-15:00)were the most reliable for estimating CWSI.Negative linear relationships were found between the transpiration rate and CWSI-E(R^(2)of 0.3646-0.5725)and CWSI-T(R^(2)of 0.5407-0.7213).The relations between fraction of available soil water(FASW)with CWSI-T was higher than that with CWSI-E,indicating CWSI-T was more accurate for predicting crop water status.In addition,The R^(2)between CWSI-T and FASW at 14:00 was higher than that at other times,indicating that 14:00 was the optimal time for using the CWSI for crop water status monitoring.Relative higher yield of winter wheat was obtained with average seasonal values of CWSI-E and CWSI-T around 0.23 and 0.25-0.26,respectively.The CWSI-E values were more easily influenced by meteorological factors and the timing of the measurements,and using the theoretical approach to derive the CWSI was recommended for precise irrigation water management. 展开更多
关键词 Canopy temperature measuring time measuring height and direction Crop water stress index
下载PDF
In situ temperature measurement of vapor based on atomic speed selection
4
作者 于露 曹俐 +2 位作者 岳子骞 李林 翟跃阳 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期189-192,共4页
We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position... We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry. 展开更多
关键词 temperature measurement saturated absorption spectrum Doppler broadening atomic velocity distribution
下载PDF
Revamping design of an EAF automatic temperature measurement and sampling robot
5
作者 JIN Guoping WEI Zhenhong DONG Yiming 《Baosteel Technical Research》 CAS 2023年第3期32-39,共8页
The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key poin... The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key points of design and revamping experience on the site layout,device protection,lance tool,probe container,measuring position control,and system safety were summarized.Furthermore,a valuable reference for the application of automatic temperature measuring and sampling robots in EAF steelmaking plants will be provided. 展开更多
关键词 ROBOT electric arc furnace(EAF) temperature measuring sampling
下载PDF
Spatial pattern recognition for near-surface high temperature increases in mountain areas using MODIS and SRTM DEM
6
作者 WANG Yanxia YANG Lisha +1 位作者 HUANG Xiaoyuan ZHOU Ruliang 《Journal of Mountain Science》 SCIE CSCD 2024年第6期2025-2042,共18页
Abrupt near-surface temperature changes in mountainous areas are a special component of the mountain climate system.Fast and accurate measurements of the locations,intensity,and width of the near-surface changes are n... Abrupt near-surface temperature changes in mountainous areas are a special component of the mountain climate system.Fast and accurate measurements of the locations,intensity,and width of the near-surface changes are necessary but highly difficult due to the complicated environmental conditions and instrumental issues.This paper develops a spatial pattern recognition method to measure the near-surface high temperature increase(NSHTI),one of the lesser-attended changes.First,raster window measurement was proposed to calculate the temperature lapse rate using MODIS land surface temperature and SRTM DEM data.It fully considers the terrain heights of two neighboring cells on opposite or adjacent slopes with a moving window of 3×3 cell size.Second,a threshold selection was performed to identify the NSHTI cells using a threshold of-0.65℃/100 m.Then,the NSHTI strips were parameterized through raster vectorization and spatial analysis.Taking Yunnan,a mountainous province in southwestern China,as the study area,the results indicate that the NSHTI cells concentrate in a strip-like pattern along the mountains and valleys,and the strips are almost parallel to the altitude contours with a slight northward uplift.Also,they are located mostly at a 3/5 height of high mountains or within 400 m from the valley floors,where the controlling topographic index is the altitude of the terrain trend surface but not the absolute elevation and the topographic uplift height and cutting depth.Additionally,the NSHTI intensity varies with the geographic locations and the proportions increase with an exponential trend,and the horizontal width has a mean of about 1000 m and a maximum of over 5000 m.The result demonstrates that the proposed method can effectively recognize NSHTI boundaries over mountains,providing support for the modeling of weather and climate systems and the development of mountain resources. 展开更多
关键词 High temperature increase Mountain areas MODIS Spatial pattern recognition Raster window measurement Threshold selection
下载PDF
Experimental investigation for temperature and emissivity by flame emission spectrum in a cavity of rocket based combined cycle combustor chamber
7
作者 Weiguang Cai Shu Zheng +4 位作者 Yan Wang Bing Liu Shaohua Zhu Li Zhao Qiang Lu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第9期114-122,共9页
Flame temperature and spectral emissivity were the important parameters characterizing the sufficient degree of fuel combustion and the particle radiative characteristics in the Rocket Based Combined Cycle(RBCC)combus... Flame temperature and spectral emissivity were the important parameters characterizing the sufficient degree of fuel combustion and the particle radiative characteristics in the Rocket Based Combined Cycle(RBCC)combustor.To investigate the combustion characteristics of the complex supersonic flame in the RBCC combustor,a new radiation thermometry combined with Levenberg-Marquardt(LM)algorithm and the least squares method was proposed to measure the temperature,emissivity and spectral radiative properties based on the flame emission spectrum.In-situ measurements of the flame temperature,emissivity and spectral radiative properties were carried out in the RBCC direct-connected test bench with laser-induced plasma combustion enhancement(LIPCE)and without LIPCE.The flame average temperatures at fuel global equivalence ratio(a)of 1.0b and 0.6 with LIPCE were 4.51%and 2.08%higher than those without LIPCE.The flame combustion oscillation of kerosene tended to be stable in the recirculation zone of cavity with the thermal and chemical effects of laser induced plasma.The differences of flame temperature at a=1.0b and 0.6 were 503 K and 523 K with LIPCE,which were 20.07%and42.64%lower than those without LIPCE.The flame emissivity with methane assisted ignition was 80.46%lower than that without methane assisted ignition,due to the carbon-hydrogen ratio of kerosene was higher than that of methane.The spectral emissivities at 600 nm with LIPCE were 1.25%,22.2%,and 4.22%lower than those without LIPCE at a=1.0a(with methane assisted ignition),1.0b(without methane assisted ignition)and 0.6.The effect of concentration in the emissivity was removed by normalization to analyze the flame radiative properties in the RBCC combustor chamber.The maximum differences of flame normalized emissivity were 50.91%without LIPCE and 27.53%with LIPCE.The flame radiative properties were stabilized under the thermal and chemical effects of laser induced plasma at a=0.6. 展开更多
关键词 Rocket-based combined-cycle Supersonic combustion Flame temperature measurement EMISSIVITY Laser induced plasma combustion enhancement
下载PDF
Skin temperature measurement method 被引量:3
8
作者 彭友辉 连之伟 潘黎 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期258-261,共4页
To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is wel... To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research. 展开更多
关键词 thermal comfort skin temperature measurement platinum film resistance
下载PDF
Measurements of non-equilibrium and equilibrium temperature behind a strong shock wave in simulated martian atmosphere 被引量:4
9
作者 Xin Lin Xi-Long Yu +3 位作者 Fei Li Shao-Hua Zhang Jian-Guo Xin Xin-Yu Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第5期1296-1302,共7页
Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- reso... Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry. 展开更多
关键词 Radiation measurements - Shock wave Marsre-entry Rotational temperature Vibrational temperature
下载PDF
Temperature and light tolerance of representative brown,green and red algae in tumble culture revealed by chlorophyll fluorescence measurements 被引量:4
10
作者 PANG Shaojun SHAN Tifeng 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2008年第4期137-146,共10页
Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viabl... Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viable biomass, rapid growth and promising nutrient uptake rates. In this investigation, the responses of the optimal chlorophyll fluorescence yield of the five algal species in tumble culture were assessed at a temperature range of 10 - 30℃. The results revealed that Ulva lactuca was the most resistant species to high temperature, withstanding 30℃ for 4 h without apparent decline in the optimal chlorophyll fluorescence yield . While the arctic alga Palmaria palmata was the most vulnerable one, showing significant decline in the optimal chlorophyll fluorescence yield at 25℃ for 2 h. The cold-water species Laminaria japonica, however, demonstrated strong ability to cope with higher temperature (24 -26℃ ) for shorter time (within 24 h) without significant decline in the optimal chlorophyll fluorescence yield . Grateloupia turuturu showed a general decrease in the optimal chlorophyll fluorescence yield with the rising temperature from 23 to 30℃ , similar to the temperate kelp Undaria pinnatifida. Changes of chlorophyll fluorescence yields of these algae were characterized differently indicating the existence of species-unique strategy to cope with high light. Measurements of the optimal chlorophyll fluorescence yield after short exposure to direct solar irradiance revealed how long these exposures could be without significant photoinhibition or with promising recovery in photosynthetic activities. Seasonal pattern of alternation of algal species in tank culture in the Northern Hemisphere at the latitude of 36°N was proposed according to these basic measurements. 展开更多
关键词 seaweeds chlorophyll fluorescence measurements Pulse Amplitude Modulation temperature tolerance integrated aquaculture
下载PDF
Simultaneous measurement of strain and temperature: graphical representation 被引量:3
11
作者 W Jin (Dept. Electr. Eng., Hong Kong Polytechnic Univ. ) W C Michie, G Thursby, M Konstantaki, B Culshaw (Optoelectron. Div., Univ. of Strathclyde, Glasgow, UK) 《大连理工大学学报》 EI CAS CSCD 北大核心 1997年第S2期58-61,共4页
Simultaneousmeasurementofstrainandtemperature:graphicalrepresentation⒇WJin(Dept.Electr.Eng.,HongKongPolytech... Simultaneousmeasurementofstrainandtemperature:graphicalrepresentation⒇WJin(Dept.Electr.Eng.,HongKongPolytechnicUniv.)WCMichie... 展开更多
关键词 STRAIN temperature measurement
下载PDF
Investigation on the plastic work-heat conversion coefficient of 7075-T651 aluminum alloy during an impact process based on infrared temperature measurement technology 被引量:3
12
作者 Tong Zhang Ze-Rong Guo +1 位作者 Fu-Ping Yuan Hu-Sheng Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2018年第2期327-333,共7页
The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic com... The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat. 展开更多
关键词 Plastic work-heat conversion coefficient Infrared temperature measurement Dynamic compression 7075-T651 Aluminum alloy
下载PDF
Comparisons of the temperature and humidity profiles of reanalysis products with shipboard GPS sounding measurements obtained during the 2018 Eastern Indian Ocean Open Cruise 被引量:3
13
作者 WANG Lei BAO Qing +4 位作者 LI Jinxiao WANG Dongxiao LIU Yimin WU Guoxiong WU Xiaofei 《Atmospheric and Oceanic Science Letters》 CSCD 2019年第3期177-183,共7页
It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) te... It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) temperature and relative humidity profiles from three reanalysis products (JRA-55, MERRA2, and FGOALS-f2) with shipboard global positioning system (GPS) sounding measurements obtained during the Eastern Indian Ocean Open Cruise in spring 2018. The FGOALS-f2 reanalysis product is based on the initialization module of a sub-seasonal to seasonal prediction system with a nudging-based data assimilation method. The results indicated that:(1) both JRA-55 and MERRA2 were reliable in characterizing the temperature profile from 850 to 600 hPa, with a maximum deviation of about <0.5℃. Both datasets showed a large negative deviation below 825 hPa, with a maximum bias of about 2℃ at 1000 hPa and 1.5℃ at 900 hPa, respectively.(2) JRA-55 showed good performance in characterizing the relative humidity profile above 850 hPa, with a maximum deviation of < 8%, while it showed much wetter conditions below 850 hPa. MERRA2 overestimated the relative humidity in the middle to lower troposphere, with a maximum deviation of about 15% at 925 hPa.(3) The FGOALS-f2 reanalysis product more accurately reproduced the temperature profile in the marine atmospheric boundary layer over the EEIO than that in JRA-55 and MERRA2, but showed much wetter conditions than the GPS sounding observations, with a maximum deviation of up to 20% at 600 hPa. Future applications of GPS sounding datasets are discussed. 展开更多
关键词 GPS sounding measurements equatorial eastern Indian Ocean temperature and humidity profiles reanalysis datasets characterization of performance
下载PDF
Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser 被引量:3
14
作者 Xilong Yu Fei Li Lihong Chen Xinyu Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2010年第1期147-149,共3页
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS... A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS. 展开更多
关键词 WMS-2fTDLAS - Profile fitting Spatial resolved - temperature measurement
下载PDF
Computation and measurement for distributions of temperature and soot volume fraction in diffusion flames 被引量:1
15
作者 张引弟 娄春 +2 位作者 谢明亮 方庆艳 周怀春 《Journal of Central South University》 SCIE EI CAS 2011年第4期1263-1271,共9页
A combined computational and experimental investigation to examine temperature and soot volume fraction in coflow ethylene-air diffusion flames was presented.A numerical simulation was conducted by using a relatively ... A combined computational and experimental investigation to examine temperature and soot volume fraction in coflow ethylene-air diffusion flames was presented.A numerical simulation was conducted by using a relatively detailed gas-phase chemistry and complex thermal and transport properties coupled with a semi-empirical two-equation soot model.Thermal radiation was calculated using the discrete ordinates method.An image processing technique and a decoupled reconstruction method were used to simultaneously measure the distributions of temperature and soot volume fraction.The results show that the maximum error for temperature does not exceed 10% between the prediction and the measurement.And the maximum error is 6.9% for soot volume fraction between prediction and measurement.Additional simulations were performed to explore the effects of global equivalence ratio on diffusion flames and the soot formation.The results display that the soot formation increases with decreasing the coflow air velocity.And the soot formation in each case appears in the annular region,where the temperature ranges from about 1 000 K to 2 000 K and the profile becomes taller and wider when the coflow air is decreased. 展开更多
关键词 temperature soot volume fraction SIMULATION measurement diffusion flame
下载PDF
Evaluating the contribution of satellite measurements to the reconstruction of three-dimensional ocean temperature fields in combination with Argo profiles 被引量:1
16
作者 Jian Chen Hengqian Yan +3 位作者 Senliang Bao Xindong Cui Chengzu Bai Huizan Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第2期65-79,共15页
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ... Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics). 展开更多
关键词 satellite measurements ARGO three-dimensional reconstruction ocean temperature
下载PDF
Research on synchronous measurement technique of temperature and deformation fields using multispectral camera with bilateral telecentric lens 被引量:1
17
作者 Wenxiong Shi Yangyang Li +4 位作者 Ru Chen Chenghao Zhang Zhanwei Liu Huimin Xie Fei Liu 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2022年第3期137-144,共8页
The hot-section parts easily occur the creep-fatigued interaction under the condition of mechanicalthermal coupled load during the period of service, which may lead to the damage of the parts, and therefore, the measu... The hot-section parts easily occur the creep-fatigued interaction under the condition of mechanicalthermal coupled load during the period of service, which may lead to the damage of the parts, and therefore, the measurement and characterization of thermal-deformed fields of the parts are important to understand its damage process. Aiming at relevant demand, the bilateral telecentric-multispectral imaging system was established, the research of synchronous measurement technique of the temperature and deformation fields was developed. On the one hand, the measurement technology for surface temperature of the object was developed using the two-color images captured by the multispectral camera with bilateral telecentric lens and combined with colorimetric method. On the other hand, the 2 D-DIC measurement technique of the multispectral camera was developed by conducting digital image correlation analysis using the blue light images before and after deformation, which can measure the high temperature deformation field of the object(the blue light images were filtered by multispectral camera).Results showed that the bilateral telecentric lens is used to replace the ordinary optical lens for imaging,which can effectively eliminate the distortion of the multispectral imaging system. Since the temperature measurement process of this measurement system is little affected by the emissivity of the object, therefore, it has excellent robustness. The thermal expansion coefficients of the nickel alloys are evaluated at the temperature ranges of 700–1000℃, indicating this system can achieve the synchronous and precise measurement of the temperature and deformation fields of the object. 展开更多
关键词 Bilateral telecentric-multispectral measuring system Colorimetric method Digital image correlation Synchronous measurement temperature and deformation fields
下载PDF
Environmental temperature effect on dimensional measurements of atomic force microscopy 被引量:1
18
作者 Chengfu Ma Yuhang Chen Wenhao Huang 《Nanotechnology and Precision Engineering》 CAS CSCD 2021年第2期20-24,共5页
Atomic force microscopy(AFM)is increasingly being used as a fundamental tool for dimensional measurements at the nanoscale in the laboratory and in industry.Since the environmental temperature is not controlled in man... Atomic force microscopy(AFM)is increasingly being used as a fundamental tool for dimensional measurements at the nanoscale in the laboratory and in industry.Since the environmental temperature is not controlled in many measurements,or is even varied on purpose,quantification of its effects on AFM dimensional measurements is needed.In this paper,the influences of the temperature in the entire environment of the AFM(excluding only the controller and computer)and that in the local environment around the tip–sample are investigated.The results show that lateral dimensional measurements are affected mainly by the entire environmental temperature.However,vertical measurements are influenced by the temperature of both the entire environment and the local environment.The effects become significant for temperatures higher than some threshold,here between 35 and 40 XC. 展开更多
关键词 Atomic force microscopy Environmental temperature Dimensional measurement PITCH HEIGHT
下载PDF
Measurement of a Three-dimensional Gas Temperature Field with Holographic Interferometry 被引量:2
19
作者 CHEN Shaohua(Yibin Teacher’s College, Yibin 644007, CHN)ZHAO Xuxin HUANG Suyi SHI Dufang(Huazhong University of Science and Technology, Wuhan 430074, CHN) 《Semiconductor Photonics and Technology》 CAS 1996年第1期72-78,共7页
It is well known that optical tomography can accurately and quantitatively reconstruct the refractive index field of a transparent medium and display the three dimensional image of other physical quantities relevant t... It is well known that optical tomography can accurately and quantitatively reconstruct the refractive index field of a transparent medium and display the three dimensional image of other physical quantities relevant to temperature or density. In this paper, a new multidirectional holographic interferometric system is built, and two kinds of image reconstruction algorithms are introduced and an automatic image processing system of interferogram is designed. A three dimentsional asymmetric gas flow field above a combustor is expertmentally investigated with holographic interferometry. The reconstructed temperatures are similar to those measured with a thermocouple. 展开更多
关键词 Optical Tomography Orthographic Holography Reconstruction Algorithm Image Processing temperature measurement
下载PDF
The Design of Fiber Bragg Grating Temperature Measurement System Based on Labview 被引量:1
20
作者 Peng Gao Shengpeng Wan +3 位作者 Yuhua Xiong Fangyu Hu Haiming Wen Yuanding Ma 《Journal of Computer and Communications》 2013年第7期27-31,共5页
The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the softwar... The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the software realized rapid and accurate spectral data fitting, improving dynamic characteristics and measuring precision of the system. Depending on different fiber Bragg grating sensors, it can realize flexible calibration. It has the functions of collection, display and data storage, which can flexibly design alarm threshold according to the practical application. The fiber Bragg grating sensors can be identified by the software so that the distributed network, with large capacity optical fiber sensing, can be achieved. 展开更多
关键词 Optical FIBER SENSING LABVIEW temperature measurement UPPER MONITOR
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部