期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Preliminary Evaluation of Hemodynamic Effects of Fontan Palliation on Renal Artery Using Computational Fluid Dynamics
1
作者 Jinlong Liu Jing Shi +6 位作者 Weiru Luo Zhirong Tong Lefei Yang Peixuan Sun Tianyi Li Jun Du Qian Wang 《Congenital Heart Disease》 SCIE 2023年第1期41-55,共15页
Background:The assessment of renal function is important to the prognosis of patients needing Fontan palliation due to the reconstructed compromised circulation.To know the relationship between the kidney perfusion an... Background:The assessment of renal function is important to the prognosis of patients needing Fontan palliation due to the reconstructed compromised circulation.To know the relationship between the kidney perfusion and hemodynamic characteristics during surgical design could reduce the risk of acute kidney injury(AKI)and the postoperative complications.However,the issue is still unsolved because the current clinical evaluation methods are unable to predict the hemodynamic changes in renal artery(RA).Methods:We reconstructed a three-dimensional(3D)vascular model of a patient requiring Fontan palliation.The technique of computational fluid dynamics(CFD)was utilized to explore the changes of RA hemodynamics under different possible blood flow rates.The relationship between the kidney perfusion and hemodynamic characteristics was investigated.Results:The calculated results indicated the declined tendency of the pressure and pressure drop as the flow rate decreased.When the flow rate decreased to two-thirds of its baseline,both the pressure of left renal artery(LRA)and the pressure of right renal artery(RRA)dipped below 50%,and the pressure of RRA fell more quickly than that of LRA.Uneven distribution of WSS was observed on the trunk of RA,and the lowest WSS was found at the distal of RA.The average WSS in RA dropped to around 50%as the flow rate reached one-third of its baseline.Conclusions:As a promising approach,CFD can be utilized to quantitatively evaluate the hemodynamic characteristics of RA and contribute to offsetting the drawbacks of clinical assessments of renal function,to help realize better prognosis for the patients with Fontan palliation. 展开更多
关键词 Renal artery fontan palliation HEMODYNAMICS computational fluid dynamics surgical design
下载PDF
Comparison of 2D and 4D Flow MRI Measurements for Hemodynamic Evaluation of the Fontan Palliation
2
作者 Elisa Listo Nicola Martini +8 位作者 Stefano Salvadori Elisa Valenti Nicola Stagnaro Gianluca Trocchio Chiara Marrone Alberto Clemente Francesca Raimondi Pierluigi Festa Lamia Ait Ali 《Congenital Heart Disease》 SCIE 2023年第6期627-638,共12页
Background:The assessment of Fontan circuit’sflow is traditionally evaluated by multiple through-plane phase-contrast MRI acquisitions(2Dflow),while recently,a single volumetric 4D-flow MRI acquisition is emerging as a ... Background:The assessment of Fontan circuit’sflow is traditionally evaluated by multiple through-plane phase-contrast MRI acquisitions(2Dflow),while recently,a single volumetric 4D-flow MRI acquisition is emerging as a comprehensive tool for the hemodynamic evaluation in congenital heart diseases.Purpose:To compare 2D and 4D-flow MRI measurements in patients after Fontan palliation and to evaluate parameters affecting potential dis-agreement.Methods:39 patients after Fontan palliation(23 males,age 22±11 years)who underwent cardiac MRI with 2D and 4D-flow MRI acquisition were included in the study.In all patients,bloodflow quantification in the Fontan circuit and aorta by 2Dflow and by 4Dflow MRI acquisition blinding to the 2D results was per-formed.The agreement between 2D and 4D-flow MRI was calculated as the intraclass correlation coefficient(ICC).The mean absolute differences between 4D and 2Dflows were analyzed using linear regression models.Results:4D-flow MRI acquisition time was slightly lower than 2D(7.6±1.8 min vs.9.4±3.3 min,p=0.03).Flow was slightly predominant in the right pulmonary artery(58%of total pulmonaryflow).Conduit/tunnel-pul-monary arteriesflow accounted for 60%of the Fontan circuit.Agreement between 2D and 4D was overall good-to-excellent from ICC:0.81795%CI:0.637–0.907 to 0.93295%CI:0.866–0.965.There was no significant influ-ence of evaluated parameters on the agreement on 4D and 2Dflow.Conclusions:4D-flow MRI represents a valid tool in Fontan’sflow quantification.Further larger studies are needed to confirm our results and to evaluate the impact of advanced 4D-flow MRI parameters on the prognostic stratification in patients after Fontan palliation. 展开更多
关键词 fontan palliation fontanflows 4Dflow MRI 2Dflow MRI cardiac magnetic resonance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部