Objective:To investigate the feasibility of a 4D-CT reconstruction method based on the similarity principle of spatial adjacent images and mutual information measure. Methods:A motor driven sinusoidal motion platform ...Objective:To investigate the feasibility of a 4D-CT reconstruction method based on the similarity principle of spatial adjacent images and mutual information measure. Methods:A motor driven sinusoidal motion platform made in house was used to create one-dimensional periodical motion that was along the longitudinal axis of the CT couch. The amplitude of sinusoidal motion was set to an amplitude of ±1 cm. The period of the motion was adjustable and set to 3.5 s. Phantom objects of two eggs were placed in a Styrofoam block, which in turn were placed on the motion platform. These objects were used to simulate volumes of interest undergoing ideal periodic motion. CT data of static phantom were acquired using a multi-slice general electric (GE) LightSpeed 16-slice CT scanner in an axial mode. And the CT data of periodical motion phantom were acquired in an axial and cine-mode scan. A software program was developed by using VC++ and VTK software tools to resort the CT data and reconstruct the 4D-CT. Then all of the CT data with same phase were sorted by the program into the same series based on the similarity principle of spatial adjacent images and mutual information measure among them, and 3D reconstruction of different phase CT data were completed by using the software. Results:All of the CT data were sorted accurately into different series based on the similarity principle of spatial adjacent images and mutual information measures among them. Compared with the unsorted CT data, the motion artifacts in the 3D reconstruction of sorted CT data were reduced significantly, and all of the sorted CT series result in a 4D-CT that reflected the characteristic of the periodical motion phantom. Conclusion:Time-resolved 4D-CT reconstruction can be implemented with any general multi-slice CT scanners based on the similarity principle of spatial adjacent images and mutual information measure.The process of the 4D-CT data acquisition and reconstruction were not restricted to the hardware or software of the CT scanner and has the feasibility ,which extensive applicability.展开更多
Objective: The purpose of this study was to evaluate the performance of the phase-binning algorithm and amplitude-binning algorithm for four-dimensional computed tomography(4DCT) reconstruction in lung cancer radiatio...Objective: The purpose of this study was to evaluate the performance of the phase-binning algorithm and amplitude-binning algorithm for four-dimensional computed tomography(4DCT) reconstruction in lung cancer radiation therapy. Methods: Quasar phantom data were used for evaluation. A phantom of known geometry was mounted on a four-dimensional(4D) motion platform programmed with twelve respiratory waves(twelve lung patients trajectories) and scanned with a Philips Brilliance Big bore 16-slice CT simulator. The 4DCT images were reconstructed using both phase- and amplitude-binning algorithms. Internal target volumes(ITVs) of the phase- and amplitude-binned image sets were compared by evaluation of shape and volume distortions. Results: The phantom experiments illustrated that, as expected, maximum inhalation occurred at the 0% amplitude and maximum exhalation occurred at the 50% amplitude of the amplitude-binned 4DCT image sets. The amplitude-binned algorithm rendered smaller ITV than the phase-binning algorithm. Conclusion: The amplitude-binning algorithm for 4DCT reconstruction may have a potential advantage in reducing the margin and protecting normal lung tissue from unnecessary irradiation.展开更多
Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor al...Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor along the cranial-caudal direction is constructed by step motor, small ball of polyethylene and potato. Ten different scan protocols were set and CT data of the phantom were acquired by using a commercial GE LightSpeedl6 CT scanner. The 3D reconstruction of the CT data was implemented by adopting volume-rendering technology of GE AdvantageSim 6.0 system. The reconstructed volumes of each target in different scan protocols were measured through 3D measuring tools. Thus, relative deviations of the reconstruction volumes between moving targets and static ones were determined. The three-dimensional conformal radiation therapy (3D- CRT) plans and conformal fields were created and compared for a static/moving target with the WiMRT treatment planning system (TPS). Results:For a static target, there was no obvious difference among the 3D reconstruction volumes when the CT data were acquired with different pitches and slices. The appearance of 3D reconstruction volume and 3D conformal field of a moving target was quite different from that of static one. The maximum relative deviation is nearly 90% for a moving target scanned with different scan protocols. The relative deviations are variable among the different targets, about from -39.8% to 89.5% for a smaller target and from - 18.4% to 20.5% for a larger one. Conclusion :The motion artifacts have great effects on 3 D-CRT planning and reconstruction volume, which will greatly induce distorted conformal radiation fields and false DVHs for a moving target.展开更多
基金Guangzhou Municipal Medicine &Health ProgramGrant number:2006-YB-177+1 种基金Guangdong Province Medicine Scientific Research ProgramGrant number:A2007290
文摘Objective:To investigate the feasibility of a 4D-CT reconstruction method based on the similarity principle of spatial adjacent images and mutual information measure. Methods:A motor driven sinusoidal motion platform made in house was used to create one-dimensional periodical motion that was along the longitudinal axis of the CT couch. The amplitude of sinusoidal motion was set to an amplitude of ±1 cm. The period of the motion was adjustable and set to 3.5 s. Phantom objects of two eggs were placed in a Styrofoam block, which in turn were placed on the motion platform. These objects were used to simulate volumes of interest undergoing ideal periodic motion. CT data of static phantom were acquired using a multi-slice general electric (GE) LightSpeed 16-slice CT scanner in an axial mode. And the CT data of periodical motion phantom were acquired in an axial and cine-mode scan. A software program was developed by using VC++ and VTK software tools to resort the CT data and reconstruct the 4D-CT. Then all of the CT data with same phase were sorted by the program into the same series based on the similarity principle of spatial adjacent images and mutual information measure among them, and 3D reconstruction of different phase CT data were completed by using the software. Results:All of the CT data were sorted accurately into different series based on the similarity principle of spatial adjacent images and mutual information measures among them. Compared with the unsorted CT data, the motion artifacts in the 3D reconstruction of sorted CT data were reduced significantly, and all of the sorted CT series result in a 4D-CT that reflected the characteristic of the periodical motion phantom. Conclusion:Time-resolved 4D-CT reconstruction can be implemented with any general multi-slice CT scanners based on the similarity principle of spatial adjacent images and mutual information measure.The process of the 4D-CT data acquisition and reconstruction were not restricted to the hardware or software of the CT scanner and has the feasibility ,which extensive applicability.
文摘Objective: The purpose of this study was to evaluate the performance of the phase-binning algorithm and amplitude-binning algorithm for four-dimensional computed tomography(4DCT) reconstruction in lung cancer radiation therapy. Methods: Quasar phantom data were used for evaluation. A phantom of known geometry was mounted on a four-dimensional(4D) motion platform programmed with twelve respiratory waves(twelve lung patients trajectories) and scanned with a Philips Brilliance Big bore 16-slice CT simulator. The 4DCT images were reconstructed using both phase- and amplitude-binning algorithms. Internal target volumes(ITVs) of the phase- and amplitude-binned image sets were compared by evaluation of shape and volume distortions. Results: The phantom experiments illustrated that, as expected, maximum inhalation occurred at the 0% amplitude and maximum exhalation occurred at the 50% amplitude of the amplitude-binned 4DCT image sets. The amplitude-binned algorithm rendered smaller ITV than the phase-binning algorithm. Conclusion: The amplitude-binning algorithm for 4DCT reconstruction may have a potential advantage in reducing the margin and protecting normal lung tissue from unnecessary irradiation.
基金Grant sponsor:Guangzhou Municipal Medicin &Health ProgramGrant number:2006-YB-177
文摘Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor along the cranial-caudal direction is constructed by step motor, small ball of polyethylene and potato. Ten different scan protocols were set and CT data of the phantom were acquired by using a commercial GE LightSpeedl6 CT scanner. The 3D reconstruction of the CT data was implemented by adopting volume-rendering technology of GE AdvantageSim 6.0 system. The reconstructed volumes of each target in different scan protocols were measured through 3D measuring tools. Thus, relative deviations of the reconstruction volumes between moving targets and static ones were determined. The three-dimensional conformal radiation therapy (3D- CRT) plans and conformal fields were created and compared for a static/moving target with the WiMRT treatment planning system (TPS). Results:For a static target, there was no obvious difference among the 3D reconstruction volumes when the CT data were acquired with different pitches and slices. The appearance of 3D reconstruction volume and 3D conformal field of a moving target was quite different from that of static one. The maximum relative deviation is nearly 90% for a moving target scanned with different scan protocols. The relative deviations are variable among the different targets, about from -39.8% to 89.5% for a smaller target and from - 18.4% to 20.5% for a larger one. Conclusion :The motion artifacts have great effects on 3 D-CRT planning and reconstruction volume, which will greatly induce distorted conformal radiation fields and false DVHs for a moving target.