Glasses are known to possess low-frequency excess modes beyond the Debye prediction.For decades,it has been assumed that evolution of low-frequency density of excess modes D(ω) with frequency ω follows a power-law s...Glasses are known to possess low-frequency excess modes beyond the Debye prediction.For decades,it has been assumed that evolution of low-frequency density of excess modes D(ω) with frequency ω follows a power-law scaling:D(ω)~ω~γ.However,it remains debated on the value of γ at low frequencies below the first phonon-like mode in finitesize glasses.Early simulation studies reported γ=4 at low frequencies in two-(2D),three-(3D),and four-dimensional(4D)glasses,whereas recent observations in 2D and 3D glasses suggested γ=3.5 in a lower-frequency regime.It is uncertain whether the low-frequency scaling of D(ω)~ω^(3.5) could be generalized to 4D glasses.Here,we conduct numerical simulation studies of excess modes at frequencies below the first phonon-like mode in 4D model glasses.It is found that the system size dependence of D(ω) below the first phonon-like mode varies with spatial dimensions:D(ω) increases in2D glasses but decreases in 3D and 4D glasses as the system size increases.Furthermore,we demonstrate that the ω^(3.5)scaling,rather than the ω~4 scaling,works in the lowest-frequency regime accessed in 4D glasses,regardless of interaction potentials and system sizes examined.Therefore,our findings in 4D glasses,combined with previous results in 2D and 3D glasses,suggest a common low-frequency scaling of D(ω)~ ω^3.5) below the first phonon-like mode across different spatial dimensions,which would inspire further theoretical studies.展开更多
BACKGROUND Mitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation.Achieving precise measurements of artificial chordae tendineae length(CL)i...BACKGROUND Mitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation.Achieving precise measurements of artificial chordae tendineae length(CL)is an important factor in the procedure;however,no objective index currently exists to facilitate this measurement.Therefore,preoperative assessment of CL is critical for surgical planning and support.Four-dimensional x-ray micro-computed tomography(4D-CT)may be useful for accurate CL measurement considering that it allows for dynamic three-dimensional(3D)evaluation compared to that with transthoracic echocardiography,a conventional inspection method.AIM To investigate the behavior and length of mitral chordae tendineae during systole using 4D-CT.METHODS Eleven adults aged>70 years without mitral valve disease were evaluated.A 64-slice CT scanner was used to capture 20 phases in the cardiac cycle in electrocardiographic synchronization.The length of the primary chordae tendineae was measured from early systole to early diastole using the 3D image.The primary chordae tendineae originating from the anterior papillary muscle and attached to the A1-2 region and those from the posterior papillary muscle and attached to the A2-3 region were designated as cA and cP,respectively.The behavior and maximum lengths[cA(ma),cP(max)]were compared,and the correlation with body surface area(BSA)was evaluated.RESULTS In all cases,the mitral anterior leaflet chordae tendineae could be measured.In most cases,the cA and cP chordae tendineae could be measured visually.The mean cA(max)and cP(max)were 20.2 mm±1.95 mm and 23.5 mm±4.06 mm,respectively.cP(max)was significantly longer.The correlation coefficients(r)with BSA were 0.60 and 0.78 for cA(max)and cP(max),respectively.Both cA and cP exhibited constant variation in CL during systole,with a maximum 1.16-fold increase in cA and a 1.23-fold increase in cP from early to mid-systole.For cP,CL reached a plateau at 15%and remained elongated until end-systole,whereas for cA,after peaking at 15%,CL shortened slightly and then moved toward its peak again as end-systole approached.CONCLUSION The study suggests that 4D-CT is a valuable tool for accurate measurement of both the length and behavior of chordae tendineae within the anterior leaflet of the mitral valve.展开更多
The eigenvalue space of the canonical four-dimensional Chua's circuit which can realize every eigenvalue for fourdimensional system is studied in this paper. First, the analytical relations between the circuit parame...The eigenvalue space of the canonical four-dimensional Chua's circuit which can realize every eigenvalue for fourdimensional system is studied in this paper. First, the analytical relations between the circuit parameters and the eigenvalues of the system are established, and therefore all the circuit parameters can be determined explicitly by any given set of eigenvalues. Then, the eigenvalue space of the circuit is investigated in two cases by the nonlinear elements used. According to the types of the eigenvalues, some novel hyperchaotic attractors are presented. Further, the dynamic behaviours of the circuit are studied by the bifurcation diagrams and the Lyapunov spectra of the eigenvalues.展开更多
Introduction:Noninvasive diagnoses of clinically significant portal hypertension(CSPH)and high-risk gastroesophageal varices are clinically relevant but challenging.Four-dimensional(4D)flow magnetic resonance imaging(...Introduction:Noninvasive diagnoses of clinically significant portal hypertension(CSPH)and high-risk gastroesophageal varices are clinically relevant but challenging.Four-dimensional(4D)flow magnetic resonance imaging(MRI)provides comprehensive flow information and is a promising alternative.This study evaluated the efficacy of 4D flow MRI as a noninvasive method for diagnosing CSPH and high-risk varices in patients with liver cirrhosis.Methods:This prospective study enrolled consecutive patients diagnosed with liver cirrhosis at a tertiary referral center between October 2020 and March 2021.Each participant underwent abdominal 4D flow MRI.Hemodynamic parameters within the portal vein,including the average and peak flow velocities,normalized flow volume(Q_(normal)),and regurgitant fraction(R%),were extracted and compared between healthy individuals and patients with CSPH and between participants with high-and low-risk varices.Subsequently,these parameters were incorporated into a logistic regression(LR)model refined using L1 regularization and validated using five-fold cross-validation.The diagnostic efficacy was evaluated using receiver operating characteristic(ROC)curves.Results:Eighty-two participants were enrolled(71 patients diagnosed with liver cirrhosis and 11 healthy individuals serving as controls).Among hemodynamic parameters,patients with CSPH exhibited a notable increase in Q_(normal)of 0.66±0.19 ml*m^(2)/[cycle*kg](P=0.001)and an R%of 1.98(2.05)(P=0.002).Similarly,patients with high-risk varices showed a higher Q_(normal)of 0.61±0.15 ml*m^(2)/[cycle*kg](P<0.001)and R%of 1.88(2.81)(P=0.006).ROC analysis revealed an area under the curve(AUC)for Q_(normal)of 0.93 and 0.91 for R%for diagnosing CSPH,while the LR model showcased a superior AUC of 0.95.For high-risk varices,Q_(normal)and R%showed AUC values of 0.75 and 0.70,respectively,whereas the LR model showed a higher AUC of 0.84.Conclusion:As a noninvasive imaging modality,4D flow MRI exhibits considerable potential for the diagnosis of CSPH and high-risk gastroesophageal varices;thus,it may minimize the reliance on invasive procedures in patients with cirrhosis.展开更多
The four-dimensional variational assimilation(4D-Var)has been widely used in meteorological and oceanographic data assimilation.This method is usually implemented in the model space,known as primal approach(P4D-Var).A...The four-dimensional variational assimilation(4D-Var)has been widely used in meteorological and oceanographic data assimilation.This method is usually implemented in the model space,known as primal approach(P4D-Var).Alternatively,physical space analysis system(4D-PSAS)is proposed to reduce the computation cost,in which the 4D-Var problem is solved in physical space(i.e.,observation space).In this study,the conjugate gradient(CG)algorithm,implemented in the 4D-PSAS system is evaluated and it is found that the non-monotonic change of the gradient norm of 4D-PSAS cost function causes artificial oscillations of cost function in the iteration process.The reason of non-monotonic variation of gradient norm in 4D-PSAS is then analyzed.In order to overcome the non-monotonic variation of gradient norm,a new algorithm,Minimum Residual(MINRES)algorithm,is implemented in the process of assimilation iteration in this study.Our experimental results show that the improved 4D-PSAS with the MINRES algorithm guarantees the monotonic reduction of gradient norm of cost function,greatly improves the convergence properties of 4D-PSAS as well,and significantly restrains the numerical noises associated with the traditional 4D-PSAS system.展开更多
目的:对比三维多回波恢复梯度回波(3D MERGE)、三维可变反转角快速自旋回波(3D SPACE STIR)序列在腰椎间盘突出症(LDH)检查中的应用效果。方法:选择2020年1月~2022年11月收治的135例LDH患者,回顾性分析患者临床和磁共振成像(MRI)资料,...目的:对比三维多回波恢复梯度回波(3D MERGE)、三维可变反转角快速自旋回波(3D SPACE STIR)序列在腰椎间盘突出症(LDH)检查中的应用效果。方法:选择2020年1月~2022年11月收治的135例LDH患者,回顾性分析患者临床和磁共振成像(MRI)资料,所有患者均接受常规MRI扫描及3D MERGE、3D SPACE STIR序列扫描,对比3D MERGE、3D SPACE STIR序列测量神经根直径的一致性,评价两种序列的图像质量参数[信噪比(SNR)、对比噪声比(CNR)]、图像清晰度评分。结果:3D MERGE和3D SPACE STIR序列测量的L3~S1神经根直径比较差异无统计学意义(P>0.05),且两组序列测量的L3、L4、L5和S1直径均显示出较高相关性(r=0.957,0.986,0.975,0.972,P<0.05);3D MERGE序列的SNR及CNR均高于3D SPACE STIR序列,神经根显示分级、图像清晰度评分优于3D SPACE STIR序列,差异有统计学意义(P<0.05)。结论:3D MERGE、3D SPACE STIR序列在LDH神经根直径测量中具有极高一致性,3D MERGE序列较3D SPACE STIR序列能够更清晰显示神经跟的解剖形态,图像质量更好。展开更多
In the common theory of the Universe, the redshift of the light wavelength from distant stars indicates the speed of the star. In this study, the model of the Universe is the surface volume of the four-dimensional sph...In the common theory of the Universe, the redshift of the light wavelength from distant stars indicates the speed of the star. In this study, the model of the Universe is the surface volume of the four-dimensional sphere, and the shape of the Universe results in the most of the redshift of light wavelength. Therefore, there is no dark energy accelerating the Universe. The surface of the four-dimensional sphere is a volume, and this volume is a good model for the Universe. The surface volume of the four-dimensional sphere has been explained by a model of four-dimensional cube, within which the forming of surface volume can be easily shown. The model of four-dimensional cube containing six side cubes is ingenious for explaining the structure of the four-dimensional Universe, but it is not enough because the four-dimensional cube has not six side cubes, but eight side cubes. Therefore, in this study a better method has been created to construct the four-dimensional cube. Our three-dimensional Universe is the surface of the four-dimensional sphere Universe. The volume of our three-dimensional Universe is finite, and beneath it is the infinite volume four-dimensional Super Universe. Two important basic formulae have been derived: The surface volume of the four-dimensional sphere is π<sup>3</sup>R<sup>3</sup> in which R is the radius of the sphere, and the fourth-power volume of the four-dimensional sphere is 1/4 π<sup>3</sup>R<sup>4</sup>. The volume of the Universe has been calculated π<sup>3</sup>R<sup>3</sup> = 62 × 10<sup>30</sup> ly<sup>3</sup>. Time as the fourth dimension of the space takes effect only near the speed of light, and therefore it has been ignored in this study.展开更多
This study examines the performance of coupling the deterministic four-dimensional variational assimilation system (4DVAR) with an ensemble Kalman filter (EnKF) to produce a superior hybrid approach for data assim...This study examines the performance of coupling the deterministic four-dimensional variational assimilation system (4DVAR) with an ensemble Kalman filter (EnKF) to produce a superior hybrid approach for data assimilation. The coupled assimilation scheme (E4DVAR) benefits from using the state-dependent uncertainty provided by EnKF while taking advantage of 4DVAR in preventing filter divergence: the 4DVAR analysis produces posterior maximum likelihood solutions through minimization of a cost function about which the ensemble perturbations are transformed, and the resulting ensemble analysis can be propagated forward both for the next assimilation cycle and as a basis for ensemble forecasting. The feasibility and effectiveness of this coupled approach are demonstrated in an idealized model with simulated observations. It is found that the E4DVAR is capable of outperforming both 4DVAR and the EnKF under both perfect- and imperfect-model scenarios. The performance of the coupled scheme is also less sensitive to either the ensemble size or the assimilation window length than those for standard EnKF or 4DVAR implementations.展开更多
A four-dimensional variational (4D-Var) data assimilation method is implemented in an improved intermediate coupled model (ICM) of the tropical Pacific. A twin experiment is designed to evaluate the impact of the ...A four-dimensional variational (4D-Var) data assimilation method is implemented in an improved intermediate coupled model (ICM) of the tropical Pacific. A twin experiment is designed to evaluate the impact of the 4D-Var data assimilation algorithm on ENSO analysis and prediction based on the ICM. The model error is assumed to arise only from the parameter uncertainty. The "observation" of the SST anomaly, which is sampled from a "truth" model simulation that takes default parameter values and has Gaussian noise added, is directly assimilated into the assimilation model with its parameters set erroneously. Results show that 4D-Var effectively reduces the error of ENSO analysis and therefore improves the prediction skill of ENSO events compared with the non-assimilation case. These results provide a promising way for the ICM to achieve better real-time ENSO prediction.展开更多
A heavy rainfall event along the mei-yu front during 22-23 June 2002 was chosen for this study. To assess the impact of the routine and additional IOP (intensive observation period) radiosonde observations on the meso...A heavy rainfall event along the mei-yu front during 22-23 June 2002 was chosen for this study. To assess the impact of the routine and additional IOP (intensive observation period) radiosonde observations on the mesoscale heavy rainfall forecast, a series of four-dimensional variational (4DVAR) data assimilation and model simulation experiments was conducted using nonhydrostatic mesoscale model MM5 and the MM5 4DVAR system. The effects of the intensive observations in the different areas on the heavy rainfall forecast were also investigated. The results showed that improvement of the forecast skill for mesoscale heavy rainfall intensity was possible from the assimilation of the IOP radiosonde observations. However, the impact of the IOP observations on the forecast of the rainfall pattern was not significant. Initial conditions obtained through the 4DVAR experiments with a 12-h assimilation window were capable of improving the 24-h forecast. The simulated results after the assimilation showed that it would be best to perform the intensive radiosonde observations in the upstream of the rainfall area and in the moisture passageway area at the same time. Initial conditions created by the 4DVAR led to the low-level moisture convergence over the rainfall area, enhanced frontogenesis and upward motion within the mei-yu front, and intensified middle- and high-level unstable stratification in front of the mei-yu front. Consequently, the heavy rainfall forecast was improved.展开更多
螺旋藻(Spirulina)藻蓝蛋白具有独特的理化特性及生理功能,是药物、食品和化妆品的天然原料,具有较大的开发潜力。为探讨螺旋藻藻蓝蛋白的研究现状与发展前景,对中国知网和Web of Science数据库中1990—2023年发表的文献进行检索并筛选...螺旋藻(Spirulina)藻蓝蛋白具有独特的理化特性及生理功能,是药物、食品和化妆品的天然原料,具有较大的开发潜力。为探讨螺旋藻藻蓝蛋白的研究现状与发展前景,对中国知网和Web of Science数据库中1990—2023年发表的文献进行检索并筛选,使用Cite Space软件对文章发文量、研究团队及研究热点进行图谱分析。综合分析可知,国内年发文量偏少,呈平稳趋势;国外年发文量持续上升,尤其近几年发文量迅速增长,且发文量超过了100篇;国外研究热点集中于藻蓝蛋白在食品、医药行业的应用方面,而国内研究热点集中在提取纯化、稳定性、功能活性的研究与应用,下一步应结合研究现状开发适合规模化生产的提取纯化工艺,进一步加强藻蓝蛋白研究的广度与深度;国内外研究群体主要是高校的相关生物技术学院或研究机构等,总体来讲,学者间存在较为密切的合作,但研究机构间尚未形成紧密的合作关系,在地域上比较分散,各大高校和研究机构应突破地区或机构间的各种限制,促进该研究领域的深度融合和快速发展,深入挖掘藻蓝蛋白在各个领域的潜在应用。展开更多
Aircraft ground movement plays a key role in improving airport efficiency,as it acts as a link to all other ground operations.Finding novel approaches to coordinate the movements of a fleet of aircraft at an airport i...Aircraft ground movement plays a key role in improving airport efficiency,as it acts as a link to all other ground operations.Finding novel approaches to coordinate the movements of a fleet of aircraft at an airport in order to improve system resilience to disruptions with increasing autonomy is at the center of many key studies for airport airside operations.Moreover,autonomous taxiing is envisioned as a key component in future digitalized airports.However,state-of-the-art routing and scheduling algorithms for airport ground movements do not consider high-fidelity aircraft models at both the proactive and reactive planning phases.The majority of such algorithms do not actively seek to optimize fuel efficiency and reduce harmful greenhouse gas emissions.This paper proposes a new approach for generating efficient four-dimensional trajectories(4DTs)on the basis of a high-fidelity aircraft model and gainscheduling control strategy.Working in conjunction with a routing and scheduling algorithm that determines the taxi route,waypoints,and time deadlines,the proposed approach generates fuel-efficient 4DTs in real time,while respecting operational constraints.The proposed approach can be used in two contexts:①as a reactive decision support tool to generate new trajectories that can resolve unprecedented events;and②as an autopilot system for both partial and fully autonomous taxiing.The proposed methodology is realistic and simple to implement.Moreover,simulation studies show that the proposed approach is capable of providing an up to 11%reduction in the fuel consumed during the taxiing of a large Boeing 747-100 jumbo jet.展开更多
Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential...Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential element in cardiovascular and abdominal imaging.In addition to sonography and computer tomography,MRI is a valuable tool for diagnosing cardiovascular and abdominal diseases,for determining disease severity,and for assessing therapeutic success.MRI techniques have improved over the last few decades,revealing not just morphologic information,but functional information about perfusion,diffusion and hemodynamics as well.Four-dimensional(4D)flow MRI,a time-resolved phase contrast-MRI with three-dimensional(3D)anatomic coverage and velocity encoding along all three flow directions has been used to comprehensively assess complex cardiovascular hemodynamics in multiple regions of the body.The technique enables visualization of 3D blood flow patterns and retrospective quantification of blood flow parameters in a region of interest.Over the last few years,4D flow MRI has been increasingly performed in the abdominal region.By applying different acceleration techniques,taking 4D flow MRI measurements has dropped to a reasonable scanning time of 8 to 12 min.These new developments have encouraged a growing number of patient studies in the literature validating the technique’s potential for enhanced evaluation of blood flow parameters within the liver’s complex vascular system.The purpose of this review article is to broaden our understanding of 4D flow MRI for the assessment of liver hemodynamics by providing insights into acquisition,data analysis,visualization and quantification.Furthermore,in this article we highlight its development,focussing on the clinical application of the technique.展开更多
A new four-dimensional quadratic smooth autonomous chaotic system is presented in this paper, which can exhibit periodic orbit and chaos under the conditions on the system parameters. Importantly, the system can gener...A new four-dimensional quadratic smooth autonomous chaotic system is presented in this paper, which can exhibit periodic orbit and chaos under the conditions on the system parameters. Importantly, the system can generate one-, two-, three- and four-scroll chaotic attractors with appropriate choices of parameters. Interestingly, all the attractors are generated only by changing a single parameter. The dynamic analysis approach in the paper involves time series, phase portraits, Poincare maps, a bifurcation diagram, and Lyapunov exponents, to investigate some basic dynamical behaviours of the proposed four-dimensional system.展开更多
Consider a four-dimensional system having a two-dimensional invariant surface. By analyzing the solutions of bifurcation equations, this paper studied the bifurcation phenomena of a k multiple closed orbit in the inva...Consider a four-dimensional system having a two-dimensional invariant surface. By analyzing the solutions of bifurcation equations, this paper studied the bifurcation phenomena of a k multiple closed orbit in the invariant surface. Sufficient conditions for the existence of periodic orbits generated by the k multiple closed orbit were given.展开更多
In this paper, we propose a novel four-dimensional autonomous chaotic system. Of particular interest is that this novel system can generate one-, two, three- and four-wing chaotic attractors with the variation of a si...In this paper, we propose a novel four-dimensional autonomous chaotic system. Of particular interest is that this novel system can generate one-, two, three- and four-wing chaotic attractors with the variation of a single parameter, and the multi-wing type of the chaotic attractors can be displayed in all directions. The system is simple with a large positive Lyapunov exponent and can exhibit some interesting and complicated dynamical behaviours. Basic dynamical properties of the four-dimensional chaotic system, such as equilibrium points, the Poincare map, the bifurcation diagram and the Lyapunov exponents are investigated by using either theoretical analysis or numerical method. Finally, a circuit is designed for the implementation of the multi-wing chaotic attractors. The electronic workbench observations axe in good agreement with the numerical simulation results.展开更多
目的梳理国内多发伤急救相关研究文献,分析研究现状、热点和趋势,为我国多发伤急救研究提供借鉴和指导。方法检索中国知网数据库中2011—2021年关于多发伤急救的相关文献,使用Cite Space 6.1.R3可视化软件对该领域的年发文量、机构、作...目的梳理国内多发伤急救相关研究文献,分析研究现状、热点和趋势,为我国多发伤急救研究提供借鉴和指导。方法检索中国知网数据库中2011—2021年关于多发伤急救的相关文献,使用Cite Space 6.1.R3可视化软件对该领域的年发文量、机构、作者、关键词进行分析。结果最终纳入多发伤急救研究文献2519篇,整体发文数量较平稳,以2016年为小高峰;发文量最高的机构是华中科技大学附属同济医院。多发伤急救研究热点包括院前急救、并发症护理、风险因素分析和预后效果评估,研究前沿包括不同多发伤人群的诊断、治疗、手术和护理体会等方面。结论本文通过可视化分析国内多发伤急救研究的热点及趋势,指明了多发伤目前研究存在的问题和未来研究发展的方向,为进一步完善多发伤急救卫生服务和管理体系提供指导。展开更多
基金the support from the National Natural Science Foundation of China(Grant Nos.12374202 and 12004001)Anhui Projects(Grant Nos.2022AH020009,S020218016,and Z010118169)Hefei City(Grant No.Z020132009)。
文摘Glasses are known to possess low-frequency excess modes beyond the Debye prediction.For decades,it has been assumed that evolution of low-frequency density of excess modes D(ω) with frequency ω follows a power-law scaling:D(ω)~ω~γ.However,it remains debated on the value of γ at low frequencies below the first phonon-like mode in finitesize glasses.Early simulation studies reported γ=4 at low frequencies in two-(2D),three-(3D),and four-dimensional(4D)glasses,whereas recent observations in 2D and 3D glasses suggested γ=3.5 in a lower-frequency regime.It is uncertain whether the low-frequency scaling of D(ω)~ω^(3.5) could be generalized to 4D glasses.Here,we conduct numerical simulation studies of excess modes at frequencies below the first phonon-like mode in 4D model glasses.It is found that the system size dependence of D(ω) below the first phonon-like mode varies with spatial dimensions:D(ω) increases in2D glasses but decreases in 3D and 4D glasses as the system size increases.Furthermore,we demonstrate that the ω^(3.5)scaling,rather than the ω~4 scaling,works in the lowest-frequency regime accessed in 4D glasses,regardless of interaction potentials and system sizes examined.Therefore,our findings in 4D glasses,combined with previous results in 2D and 3D glasses,suggest a common low-frequency scaling of D(ω)~ ω^3.5) below the first phonon-like mode across different spatial dimensions,which would inspire further theoretical studies.
文摘BACKGROUND Mitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation.Achieving precise measurements of artificial chordae tendineae length(CL)is an important factor in the procedure;however,no objective index currently exists to facilitate this measurement.Therefore,preoperative assessment of CL is critical for surgical planning and support.Four-dimensional x-ray micro-computed tomography(4D-CT)may be useful for accurate CL measurement considering that it allows for dynamic three-dimensional(3D)evaluation compared to that with transthoracic echocardiography,a conventional inspection method.AIM To investigate the behavior and length of mitral chordae tendineae during systole using 4D-CT.METHODS Eleven adults aged>70 years without mitral valve disease were evaluated.A 64-slice CT scanner was used to capture 20 phases in the cardiac cycle in electrocardiographic synchronization.The length of the primary chordae tendineae was measured from early systole to early diastole using the 3D image.The primary chordae tendineae originating from the anterior papillary muscle and attached to the A1-2 region and those from the posterior papillary muscle and attached to the A2-3 region were designated as cA and cP,respectively.The behavior and maximum lengths[cA(ma),cP(max)]were compared,and the correlation with body surface area(BSA)was evaluated.RESULTS In all cases,the mitral anterior leaflet chordae tendineae could be measured.In most cases,the cA and cP chordae tendineae could be measured visually.The mean cA(max)and cP(max)were 20.2 mm±1.95 mm and 23.5 mm±4.06 mm,respectively.cP(max)was significantly longer.The correlation coefficients(r)with BSA were 0.60 and 0.78 for cA(max)and cP(max),respectively.Both cA and cP exhibited constant variation in CL during systole,with a maximum 1.16-fold increase in cA and a 1.23-fold increase in cP from early to mid-systole.For cP,CL reached a plateau at 15%and remained elongated until end-systole,whereas for cA,after peaking at 15%,CL shortened slightly and then moved toward its peak again as end-systole approached.CONCLUSION The study suggests that 4D-CT is a valuable tool for accurate measurement of both the length and behavior of chordae tendineae within the anterior leaflet of the mitral valve.
基金Project supported by the National Natural Science Foundation of China (Grant No. 50877007)
文摘The eigenvalue space of the canonical four-dimensional Chua's circuit which can realize every eigenvalue for fourdimensional system is studied in this paper. First, the analytical relations between the circuit parameters and the eigenvalues of the system are established, and therefore all the circuit parameters can be determined explicitly by any given set of eigenvalues. Then, the eigenvalue space of the circuit is investigated in two cases by the nonlinear elements used. According to the types of the eigenvalues, some novel hyperchaotic attractors are presented. Further, the dynamic behaviours of the circuit are studied by the bifurcation diagrams and the Lyapunov spectra of the eigenvalues.
基金supported by the Key Research and Development Program of Jiangsu Province(BE2023767)Research Personnel Cultivation Programme of Zhongda Hospital,Southeast University(CZXMGSP-RC125)+2 种基金the Fundamental Research Fund of Southeast University(3290002303A2)Changjiang Scholars Talent Cultivation Project of Zhongda Hospital of Southeast University(2023YJXYYRCPY03)the Basic Research Fund,First Affiliated Hospital of Gannan Medical University(QD095).
文摘Introduction:Noninvasive diagnoses of clinically significant portal hypertension(CSPH)and high-risk gastroesophageal varices are clinically relevant but challenging.Four-dimensional(4D)flow magnetic resonance imaging(MRI)provides comprehensive flow information and is a promising alternative.This study evaluated the efficacy of 4D flow MRI as a noninvasive method for diagnosing CSPH and high-risk varices in patients with liver cirrhosis.Methods:This prospective study enrolled consecutive patients diagnosed with liver cirrhosis at a tertiary referral center between October 2020 and March 2021.Each participant underwent abdominal 4D flow MRI.Hemodynamic parameters within the portal vein,including the average and peak flow velocities,normalized flow volume(Q_(normal)),and regurgitant fraction(R%),were extracted and compared between healthy individuals and patients with CSPH and between participants with high-and low-risk varices.Subsequently,these parameters were incorporated into a logistic regression(LR)model refined using L1 regularization and validated using five-fold cross-validation.The diagnostic efficacy was evaluated using receiver operating characteristic(ROC)curves.Results:Eighty-two participants were enrolled(71 patients diagnosed with liver cirrhosis and 11 healthy individuals serving as controls).Among hemodynamic parameters,patients with CSPH exhibited a notable increase in Q_(normal)of 0.66±0.19 ml*m^(2)/[cycle*kg](P=0.001)and an R%of 1.98(2.05)(P=0.002).Similarly,patients with high-risk varices showed a higher Q_(normal)of 0.61±0.15 ml*m^(2)/[cycle*kg](P<0.001)and R%of 1.88(2.81)(P=0.006).ROC analysis revealed an area under the curve(AUC)for Q_(normal)of 0.93 and 0.91 for R%for diagnosing CSPH,while the LR model showcased a superior AUC of 0.95.For high-risk varices,Q_(normal)and R%showed AUC values of 0.75 and 0.70,respectively,whereas the LR model showed a higher AUC of 0.84.Conclusion:As a noninvasive imaging modality,4D flow MRI exhibits considerable potential for the diagnosis of CSPH and high-risk gastroesophageal varices;thus,it may minimize the reliance on invasive procedures in patients with cirrhosis.
基金The National Key Research and Development Program of China under contract Nos 2017YFC1501803 and2018YFC1506903the National Natural Science Foundation of China under contract Nos 91730304,41475021 and 41575026
文摘The four-dimensional variational assimilation(4D-Var)has been widely used in meteorological and oceanographic data assimilation.This method is usually implemented in the model space,known as primal approach(P4D-Var).Alternatively,physical space analysis system(4D-PSAS)is proposed to reduce the computation cost,in which the 4D-Var problem is solved in physical space(i.e.,observation space).In this study,the conjugate gradient(CG)algorithm,implemented in the 4D-PSAS system is evaluated and it is found that the non-monotonic change of the gradient norm of 4D-PSAS cost function causes artificial oscillations of cost function in the iteration process.The reason of non-monotonic variation of gradient norm in 4D-PSAS is then analyzed.In order to overcome the non-monotonic variation of gradient norm,a new algorithm,Minimum Residual(MINRES)algorithm,is implemented in the process of assimilation iteration in this study.Our experimental results show that the improved 4D-PSAS with the MINRES algorithm guarantees the monotonic reduction of gradient norm of cost function,greatly improves the convergence properties of 4D-PSAS as well,and significantly restrains the numerical noises associated with the traditional 4D-PSAS system.
文摘目的:对比三维多回波恢复梯度回波(3D MERGE)、三维可变反转角快速自旋回波(3D SPACE STIR)序列在腰椎间盘突出症(LDH)检查中的应用效果。方法:选择2020年1月~2022年11月收治的135例LDH患者,回顾性分析患者临床和磁共振成像(MRI)资料,所有患者均接受常规MRI扫描及3D MERGE、3D SPACE STIR序列扫描,对比3D MERGE、3D SPACE STIR序列测量神经根直径的一致性,评价两种序列的图像质量参数[信噪比(SNR)、对比噪声比(CNR)]、图像清晰度评分。结果:3D MERGE和3D SPACE STIR序列测量的L3~S1神经根直径比较差异无统计学意义(P>0.05),且两组序列测量的L3、L4、L5和S1直径均显示出较高相关性(r=0.957,0.986,0.975,0.972,P<0.05);3D MERGE序列的SNR及CNR均高于3D SPACE STIR序列,神经根显示分级、图像清晰度评分优于3D SPACE STIR序列,差异有统计学意义(P<0.05)。结论:3D MERGE、3D SPACE STIR序列在LDH神经根直径测量中具有极高一致性,3D MERGE序列较3D SPACE STIR序列能够更清晰显示神经跟的解剖形态,图像质量更好。
文摘In the common theory of the Universe, the redshift of the light wavelength from distant stars indicates the speed of the star. In this study, the model of the Universe is the surface volume of the four-dimensional sphere, and the shape of the Universe results in the most of the redshift of light wavelength. Therefore, there is no dark energy accelerating the Universe. The surface of the four-dimensional sphere is a volume, and this volume is a good model for the Universe. The surface volume of the four-dimensional sphere has been explained by a model of four-dimensional cube, within which the forming of surface volume can be easily shown. The model of four-dimensional cube containing six side cubes is ingenious for explaining the structure of the four-dimensional Universe, but it is not enough because the four-dimensional cube has not six side cubes, but eight side cubes. Therefore, in this study a better method has been created to construct the four-dimensional cube. Our three-dimensional Universe is the surface of the four-dimensional sphere Universe. The volume of our three-dimensional Universe is finite, and beneath it is the infinite volume four-dimensional Super Universe. Two important basic formulae have been derived: The surface volume of the four-dimensional sphere is π<sup>3</sup>R<sup>3</sup> in which R is the radius of the sphere, and the fourth-power volume of the four-dimensional sphere is 1/4 π<sup>3</sup>R<sup>4</sup>. The volume of the Universe has been calculated π<sup>3</sup>R<sup>3</sup> = 62 × 10<sup>30</sup> ly<sup>3</sup>. Time as the fourth dimension of the space takes effect only near the speed of light, and therefore it has been ignored in this study.
基金sponsored by the U.S. National Science Foundation (Grant No.ATM0205599)the U.S. Offce of Navy Research under Grant N000140410471Dr. James A. Hansen was partially supported by US Offce of Naval Research (Grant No. N00014-06-1-0500)
文摘This study examines the performance of coupling the deterministic four-dimensional variational assimilation system (4DVAR) with an ensemble Kalman filter (EnKF) to produce a superior hybrid approach for data assimilation. The coupled assimilation scheme (E4DVAR) benefits from using the state-dependent uncertainty provided by EnKF while taking advantage of 4DVAR in preventing filter divergence: the 4DVAR analysis produces posterior maximum likelihood solutions through minimization of a cost function about which the ensemble perturbations are transformed, and the resulting ensemble analysis can be propagated forward both for the next assimilation cycle and as a basis for ensemble forecasting. The feasibility and effectiveness of this coupled approach are demonstrated in an idealized model with simulated observations. It is found that the E4DVAR is capable of outperforming both 4DVAR and the EnKF under both perfect- and imperfect-model scenarios. The performance of the coupled scheme is also less sensitive to either the ensemble size or the assimilation window length than those for standard EnKF or 4DVAR implementations.
基金supported by the National Natural Science Foundation of China(Grant Nos.41490644,41475101 and 41421005)the CAS Strategic Priority Project(the Western Pacific Ocean System+2 种基金Project Nos.XDA11010105,XDA11020306 and XDA11010301)the NSFC-Shandong Joint Fund for Marine Science Research Centers(Grant No.U1406401)the NSFC Innovative Group Grant(Project No.41421005)
文摘A four-dimensional variational (4D-Var) data assimilation method is implemented in an improved intermediate coupled model (ICM) of the tropical Pacific. A twin experiment is designed to evaluate the impact of the 4D-Var data assimilation algorithm on ENSO analysis and prediction based on the ICM. The model error is assumed to arise only from the parameter uncertainty. The "observation" of the SST anomaly, which is sampled from a "truth" model simulation that takes default parameter values and has Gaussian noise added, is directly assimilated into the assimilation model with its parameters set erroneously. Results show that 4D-Var effectively reduces the error of ENSO analysis and therefore improves the prediction skill of ENSO events compared with the non-assimilation case. These results provide a promising way for the ICM to achieve better real-time ENSO prediction.
文摘A heavy rainfall event along the mei-yu front during 22-23 June 2002 was chosen for this study. To assess the impact of the routine and additional IOP (intensive observation period) radiosonde observations on the mesoscale heavy rainfall forecast, a series of four-dimensional variational (4DVAR) data assimilation and model simulation experiments was conducted using nonhydrostatic mesoscale model MM5 and the MM5 4DVAR system. The effects of the intensive observations in the different areas on the heavy rainfall forecast were also investigated. The results showed that improvement of the forecast skill for mesoscale heavy rainfall intensity was possible from the assimilation of the IOP radiosonde observations. However, the impact of the IOP observations on the forecast of the rainfall pattern was not significant. Initial conditions obtained through the 4DVAR experiments with a 12-h assimilation window were capable of improving the 24-h forecast. The simulated results after the assimilation showed that it would be best to perform the intensive radiosonde observations in the upstream of the rainfall area and in the moisture passageway area at the same time. Initial conditions created by the 4DVAR led to the low-level moisture convergence over the rainfall area, enhanced frontogenesis and upward motion within the mei-yu front, and intensified middle- and high-level unstable stratification in front of the mei-yu front. Consequently, the heavy rainfall forecast was improved.
文摘螺旋藻(Spirulina)藻蓝蛋白具有独特的理化特性及生理功能,是药物、食品和化妆品的天然原料,具有较大的开发潜力。为探讨螺旋藻藻蓝蛋白的研究现状与发展前景,对中国知网和Web of Science数据库中1990—2023年发表的文献进行检索并筛选,使用Cite Space软件对文章发文量、研究团队及研究热点进行图谱分析。综合分析可知,国内年发文量偏少,呈平稳趋势;国外年发文量持续上升,尤其近几年发文量迅速增长,且发文量超过了100篇;国外研究热点集中于藻蓝蛋白在食品、医药行业的应用方面,而国内研究热点集中在提取纯化、稳定性、功能活性的研究与应用,下一步应结合研究现状开发适合规模化生产的提取纯化工艺,进一步加强藻蓝蛋白研究的广度与深度;国内外研究群体主要是高校的相关生物技术学院或研究机构等,总体来讲,学者间存在较为密切的合作,但研究机构间尚未形成紧密的合作关系,在地域上比较分散,各大高校和研究机构应突破地区或机构间的各种限制,促进该研究领域的深度融合和快速发展,深入挖掘藻蓝蛋白在各个领域的潜在应用。
基金This work was funded by the UK Engineering and Physical Sciences Research Council(EP/N029496/1,EP/N029496/2,EP/N029356/1,EP/N029577/1,and EP/N029577/2).
文摘Aircraft ground movement plays a key role in improving airport efficiency,as it acts as a link to all other ground operations.Finding novel approaches to coordinate the movements of a fleet of aircraft at an airport in order to improve system resilience to disruptions with increasing autonomy is at the center of many key studies for airport airside operations.Moreover,autonomous taxiing is envisioned as a key component in future digitalized airports.However,state-of-the-art routing and scheduling algorithms for airport ground movements do not consider high-fidelity aircraft models at both the proactive and reactive planning phases.The majority of such algorithms do not actively seek to optimize fuel efficiency and reduce harmful greenhouse gas emissions.This paper proposes a new approach for generating efficient four-dimensional trajectories(4DTs)on the basis of a high-fidelity aircraft model and gainscheduling control strategy.Working in conjunction with a routing and scheduling algorithm that determines the taxi route,waypoints,and time deadlines,the proposed approach generates fuel-efficient 4DTs in real time,while respecting operational constraints.The proposed approach can be used in two contexts:①as a reactive decision support tool to generate new trajectories that can resolve unprecedented events;and②as an autopilot system for both partial and fully autonomous taxiing.The proposed methodology is realistic and simple to implement.Moreover,simulation studies show that the proposed approach is capable of providing an up to 11%reduction in the fuel consumed during the taxiing of a large Boeing 747-100 jumbo jet.
文摘Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential element in cardiovascular and abdominal imaging.In addition to sonography and computer tomography,MRI is a valuable tool for diagnosing cardiovascular and abdominal diseases,for determining disease severity,and for assessing therapeutic success.MRI techniques have improved over the last few decades,revealing not just morphologic information,but functional information about perfusion,diffusion and hemodynamics as well.Four-dimensional(4D)flow MRI,a time-resolved phase contrast-MRI with three-dimensional(3D)anatomic coverage and velocity encoding along all three flow directions has been used to comprehensively assess complex cardiovascular hemodynamics in multiple regions of the body.The technique enables visualization of 3D blood flow patterns and retrospective quantification of blood flow parameters in a region of interest.Over the last few years,4D flow MRI has been increasingly performed in the abdominal region.By applying different acceleration techniques,taking 4D flow MRI measurements has dropped to a reasonable scanning time of 8 to 12 min.These new developments have encouraged a growing number of patient studies in the literature validating the technique’s potential for enhanced evaluation of blood flow parameters within the liver’s complex vascular system.The purpose of this review article is to broaden our understanding of 4D flow MRI for the assessment of liver hemodynamics by providing insights into acquisition,data analysis,visualization and quantification.Furthermore,in this article we highlight its development,focussing on the clinical application of the technique.
文摘A new four-dimensional quadratic smooth autonomous chaotic system is presented in this paper, which can exhibit periodic orbit and chaos under the conditions on the system parameters. Importantly, the system can generate one-, two-, three- and four-scroll chaotic attractors with appropriate choices of parameters. Interestingly, all the attractors are generated only by changing a single parameter. The dynamic analysis approach in the paper involves time series, phase portraits, Poincare maps, a bifurcation diagram, and Lyapunov exponents, to investigate some basic dynamical behaviours of the proposed four-dimensional system.
文摘Consider a four-dimensional system having a two-dimensional invariant surface. By analyzing the solutions of bifurcation equations, this paper studied the bifurcation phenomena of a k multiple closed orbit in the invariant surface. Sufficient conditions for the existence of periodic orbits generated by the k multiple closed orbit were given.
文摘In this paper, we propose a novel four-dimensional autonomous chaotic system. Of particular interest is that this novel system can generate one-, two, three- and four-wing chaotic attractors with the variation of a single parameter, and the multi-wing type of the chaotic attractors can be displayed in all directions. The system is simple with a large positive Lyapunov exponent and can exhibit some interesting and complicated dynamical behaviours. Basic dynamical properties of the four-dimensional chaotic system, such as equilibrium points, the Poincare map, the bifurcation diagram and the Lyapunov exponents are investigated by using either theoretical analysis or numerical method. Finally, a circuit is designed for the implementation of the multi-wing chaotic attractors. The electronic workbench observations axe in good agreement with the numerical simulation results.
文摘目的梳理国内多发伤急救相关研究文献,分析研究现状、热点和趋势,为我国多发伤急救研究提供借鉴和指导。方法检索中国知网数据库中2011—2021年关于多发伤急救的相关文献,使用Cite Space 6.1.R3可视化软件对该领域的年发文量、机构、作者、关键词进行分析。结果最终纳入多发伤急救研究文献2519篇,整体发文数量较平稳,以2016年为小高峰;发文量最高的机构是华中科技大学附属同济医院。多发伤急救研究热点包括院前急救、并发症护理、风险因素分析和预后效果评估,研究前沿包括不同多发伤人群的诊断、治疗、手术和护理体会等方面。结论本文通过可视化分析国内多发伤急救研究的热点及趋势,指明了多发伤目前研究存在的问题和未来研究发展的方向,为进一步完善多发伤急救卫生服务和管理体系提供指导。