期刊文献+
共找到2,640篇文章
< 1 2 132 >
每页显示 20 50 100
Mid-infrared Optical Frequency Comb-based Fourier Transform Spectrometer for Broadband Molecular Spectroscopy
1
作者 Feihu Cheng Weixiong Zhao +5 位作者 Bo Fang Nana Yang Shuangshuang Li Weijun Zhang Lunhua Deng Weidong Chen 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2024年第4期471-480,I0093,共11页
Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of pre... Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)]. 展开更多
关键词 Mid-infrared optical frequency comb Multi-pass cell fourier transform infrared spectrometer
下载PDF
GP Algorithm-Based Fourier Transform Infrared Spectrum Trend Term Removal Model
2
作者 Bo Yan Shuaihui Li Hao Chen 《Journal of Beijing Institute of Technology》 EI CAS 2023年第1期41-51,共11页
Trend term removal is a key step in Fourier transform infrared spectroscopy(FTIR)data pre-processing.The most commonly used least squares(LS)method,although satisfying the real-time requirement,has many problems such ... Trend term removal is a key step in Fourier transform infrared spectroscopy(FTIR)data pre-processing.The most commonly used least squares(LS)method,although satisfying the real-time requirement,has many problems such as highly correlated initial values of the expression parameters,the need to pre-estimate the trend term shape,and poor fitting accuracy at low signal-to-noise ratios.In order to achieve real-time and robust trend term removal,a new trend term removal method using genetic programming(GP)in symbolic regression is constructed in this paper,and the FTIR simulation interference results and experimental measurement data for common volatile organic compounds(VOCs)gases are analyzed.The results show that the genetic programming algorithm can both reduce the initial value requirement and greatly improve the trend term accuracy by 20%-30% in three evaluation indicators,which is suitable for gas FTIR detection in complex scenarios. 展开更多
关键词 fourier transform infrared spectroscopy(ftir) genetic programming(GP) trend term removal
下载PDF
The application of Fourier transform mid-infrared(FTIR) spectroscopy to identify variation in cell wall composition of Setaria italica ecotypes 被引量:2
3
作者 Christopher Brown Antony P.Martin Christopher P.L.Grof 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2017年第6期1256-1267,共12页
Cell wall composition in monocotyledonous grasses has been identified as a key area of research for developing better feedstocks for forage and biofuel production.Setaria viridis and its close domesticated relative Se... Cell wall composition in monocotyledonous grasses has been identified as a key area of research for developing better feedstocks for forage and biofuel production.Setaria viridis and its close domesticated relative Setaria italica have been chosen as suitable monocotyledonous models for plants possessing the C4 pathway of photosynthesis including sorghum,maize,sugarcane,switchgrass and Miscanthus×giganteus.Accurate partial least squares regression(PLSR)models to predict S.italica stem composition have been generated,based upon Fourier transform mid-infrared(FTIR)spectra and calibrated with wet chemistry determinations of ground S.italica stem material measured using a modified version of the US National Renewable Energy Laboratory(NREL)acid hydrolysis protocol.The models facilitated a high-throughput screening analysis for glucan,xylan,Klason lignin and acid soluble lignin(ASL)in a collection of 183 natural S.italica variants and clustered them into classes,some possessing unique chemotypes.The predictive models provide a highly efficient screening tool for large scale breeding programs aimed at identifying lines or mutants possessing unique cell wall chemotypes.Genes encoding key catalytic enzymes of the lignin biosynthesis pathway exhibit a high level of conservation with matching expression profiles,measured by RT-q PCR,among accessions of S.italica,which closely mirror profiles observed in the different developmental regions of an elongating internode of S.viridis by RNASeq. 展开更多
关键词 monocotyledonous C4 grasses lignin biosynthesis fourier transform mid-infrared spectroscopy Setaria italica
下载PDF
Classification of Toxic Cyanobacterial Blooms by Fourier-Transform Infrared Technology (FTIR) 被引量:1
4
作者 Gabriel Kenne Deon van der Merwe 《Advances in Microbiology》 2013年第6期1-8,共8页
Cyanobacteria are gram-negative photosynthetic bacteria capable of producing toxins responsible for morbidity and mortality in humans and domestic animals. They are capable of forming concentrated blooms, referred to ... Cyanobacteria are gram-negative photosynthetic bacteria capable of producing toxins responsible for morbidity and mortality in humans and domestic animals. They are capable of forming concentrated blooms, referred to as harmful algal blooms (HABs). Characterization of HABs is necessary to reduce risks from human and animal exposures to toxins. Current methods used to classify cyanobacteria and cyanotoxins have limitations related to time, analyst skills, and cost. Fourier-Transform Infrared Spectroscopy (FTIR) is a potential tool for rapid, robust cyanobacterial classification that is not limited by these factors. To examine the practicality of this method, library screening with default software algorithms was performed on HAB samples, followed by principle component cluster analyses and dendrogram analysis of samples meeting minimum quality requirements. Two tested spectrometers and software packages were successful at distinguishing cyanobacteria from green algae. Principle component cluster analysis and dendrogram analysis also resulted in clear differentiation between cyanobacteria and green algae. While these methods cannot be used independently to fully characterize HABs, they show the potential and practicality of FTIR as a screening tool. 展开更多
关键词 CYANOBACTERIA Harmful ALGAL BLOOM fourier-transform infrared Spectroscopy
下载PDF
Identification of Eight Carnation Cultivars by Fourier Transform Infrared(FTIR) Spectroscopy
5
作者 Haichao YU Gang LIU +2 位作者 Quanhong OU Dianxu MA Huimei LI 《Agricultural Biotechnology》 CAS 2016年第2期20-23,共4页
In order to distinguish eight carnation cultivars, 40 samples were analyzed by Fourier transform infrared (FI'IR) spectroscopy combined with principal component analysis (PCA) and hierarchical cluster analysis (... In order to distinguish eight carnation cultivars, 40 samples were analyzed by Fourier transform infrared (FI'IR) spectroscopy combined with principal component analysis (PCA) and hierarchical cluster analysis (HCA). According to the results, infrared spectra of eight carnation cuhivars were similar, but signifi- cant differences were observed in wave numbers and absorption peak intensities in the range of 1 800 -700cm-1. The second order derivative spectra in the range of 1 800 -700 cm -l were selected to perform principal component analysis (PCA) and hierarchical cluster analysis (HCA). The cumulative contribution rate of the first three principal components reached 96.2%. The classification accuracy rate of PCA and HCA was 95% and 100%, respectively. The results demonstrated that Fourier transform infrared (FTIR) spectroscopy combined with principal component analysis (PCA) and hierarchical cluster analysis (HCA) could be used for identification of different carnation cultivars. 展开更多
关键词 fourier transform infrared (FFIR) spectroscopy CARNATION Principal component analysis Hierarchical luster analysis
下载PDF
Carbonization mechanism of bamboo (phyllostachys) by means of Fourier Transform Infrared and elemental analysis 被引量:13
6
作者 左宋林 高尚愚 +1 位作者 阮锡根 徐柏森 《Journal of Forestry Research》 SCIE CAS CSCD 2003年第1期75-79,共5页
通过测定在200-600℃炭化竹材得到的固体产物的碳、氢、氧元素的含量及它们的红外光谱,研究了在炭化过程中竹材中半纤维素、纤维素及木素的变化规律。结果表明,结合元素分析,红外光谱分析方法是研究竹材炭化机理的有效手段。在200℃以前... 通过测定在200-600℃炭化竹材得到的固体产物的碳、氢、氧元素的含量及它们的红外光谱,研究了在炭化过程中竹材中半纤维素、纤维素及木素的变化规律。结果表明,结合元素分析,红外光谱分析方法是研究竹材炭化机理的有效手段。在200℃以前,竹材中的半纤维素和纤维素的大量羟基断裂,并结合成水而失去。在200-250℃之间,竹材中的纤维素被降解,其中的吡喃型环也遭到破坏。并且木素中的甲氧基也被脱去。竹材中的木素网状结构在250-400℃之间遭到完全的破坏。竹炭中的碳原子在600℃已基本上完成了芳环化。图3表2参15。 展开更多
关键词 BAMBOO CARBONIZATION fourier transform infrared Elemental analysis
下载PDF
Fourier Transform Infrared Spectral Difference of Leaf Tips in Rice Related to Nitrogen Fertilizer Rates 被引量:2
7
作者 周启发 沈掌泉 王人潮 《Acta Botanica Sinica》 CSCD 2002年第5期547-550,共4页
Fourier transform infrared spectroscopy (FTIR) was used to detect the spectral difference among leaf tips from rice ( Oryza sativa L.) plants with different nitrogen fertilizer rates. The proposed spectral index,... Fourier transform infrared spectroscopy (FTIR) was used to detect the spectral difference among leaf tips from rice ( Oryza sativa L.) plants with different nitrogen fertilizer rates. The proposed spectral index, ( A 3400 - A 1653 )/( A 3400 + A 1653 ) ( A denotes absorption value at certain frequency (cm -1 )), was found to decline with the increase of nitrogen fertilizer rates and the results suggested that FTIR may be useful to diagnose nitrogen status in crops. 展开更多
关键词 Oryza sativa NITROGEN fourier transform infrared spectroscopy
下载PDF
Detection of Broad Bean Diseases by Fourier Transform Infrared Spectroscopy Combined with Curve Fitting 被引量:1
8
作者 汪小华 刘刚 +4 位作者 欧全宏 周湘萍 郝建明 刘剑虹 汪禄祥 《Agricultural Science & Technology》 CAS 2015年第6期1310-1313,共4页
Fourier transform infrared (FTIR) spectroscopy was used to study diseased leaves in broad bean. Results showed that the infrared spectra of different broad bean diseased leaves were similar, which were mainly made u... Fourier transform infrared (FTIR) spectroscopy was used to study diseased leaves in broad bean. Results showed that the infrared spectra of different broad bean diseased leaves were similar, which were mainly made up of the vibrational absorption bands of protein,lipid and polysaccharide.There were minor differences in-cluding the spectral peak position, peak shape and the absorption intensity in the range of 1 800-1 300 cm-1. There were obvious differences among their second derivative spectra in the range of 1 800-1 300 cm-1. After the procedure of the Fourier self-deconvolution and curve fitting of health bean leaves and broad bean diseased leaves in the range of 1 700-1 500 cm-1, three sub-peaks were obtained at 1 550 cm-1 (protein amide Ⅱ band), 1 605 cm-1 (lignin) and 1 650 cm-1 (protein amide I band).The ratios of relative areas of the bands of amide Ⅱ, lignin, and amide I were 38.86%, 28.68% and 32.47% in the spectra of healthy leaves, respec-tively. It was distinguished from the diseased leaves (chocolate spot leaf: 15.42%, 42.98% and 41.61%, ring spot leaf:32.39%, 35.63% and 31.98%, rust leaf: 13.97%, 46.40% and 39.65%, yel owing leaf curl disease leaf: 24.01%,36.55% and 39.44%). For sub-peak area ratios (A1 563/A1 605, A1 650/A1 605 and A1 563/A1 654), those of four kinds of diseased leaves were smal er than that of healthy leaves, and there were also differences among four kinds of diseased leaves. The results proved that FTIR combining with curve fitting might be a potential y useful tool for detecting different kinds of broad bean diseases. 展开更多
关键词 fourier transform infrared ftir spectroscopy Broad bean diseases Second derivative spectra Curve fitting
下载PDF
Supercritical water syntheses of transition metal-doped CeO_2 nano-catalysts for selective catalytic reduction of NO by CO:An in situ diffuse reflectance Fourier transform infrared spectroscopy study 被引量:12
9
作者 Xiaoxia Dai Weiyu Jiang +4 位作者 Wanglong Wang Xiaole Weng Yuan Shang Yehui Xue Zhongbiao Wu 《Chinese Journal of Catalysis》 SCIE EI CAS CSCD 北大核心 2018年第4期728-735,共8页
In the present study,we synthesized CeO2 catalysts doped with various transition metals(M=Co,Fe,or Cu)using a supercritical water hydrothermal route,which led to the incorporation of the metal ions in the CeO2 lattice... In the present study,we synthesized CeO2 catalysts doped with various transition metals(M=Co,Fe,or Cu)using a supercritical water hydrothermal route,which led to the incorporation of the metal ions in the CeO2 lattice,forming solid solutions.The catalysts were then used for the selective catalytic reduction(SCR)of NO by CO.The Cu‐doped catalyst exhibited the highest SCR activity;it had a T50(i.e.,50%NO conversion)of only 83°C and a T90(i.e.,90%NO conversion)of 126°C.Such an activity was also higher than in many state‐of‐the‐art catalysts.In situ diffuse reflectance Fourier transform infrared spectroscopy suggested that the MOx‐CeO2 catalysts(M=Co and Fe)mainly followed an Eley‐Rideal reaction mechanism for CO‐SCR.In contrast,a Langmuir‐Hinshelwood SCR reaction mechanism occurred in CuO‐CeO2 owing to the presence of Cu+species,which ensured effective adsorption of CO.This explains why CuO‐CeO2 exhibited the highest activity with regard to the SCR of NO by CO. 展开更多
关键词 Supercritical water Nitrogen oxides CO Selective catalytic reduction Diffuse reflectance fourier transform infrared spectroscopy CEO2
下载PDF
Mathematic Models for Analysis of Quality Components in Sugarcane Juice with Fourier Transform Near Infrared Spectroscopy 被引量:4
10
作者 CAOGan TANZhong-wen 《Agricultural Sciences in China》 CAS CSCD 2003年第2期190-194,共5页
With the technique of Fourier transform near infrared (FT-NIR) spectroscopy, the calibration models for quantitative analysis of sucrose and polarization in sugarcane juice were developed by using transmission mode an... With the technique of Fourier transform near infrared (FT-NIR) spectroscopy, the calibration models for quantitative analysis of sucrose and polarization in sugarcane juice were developed by using transmission mode and calibrating with partial least square (PLS) algorithm. The determination coefficients (R2) of the predicted models for sucrose and polarization in juice were 0. 9980 and 0. 9979 respectively; the root mean square errors of cross validation (RMSECV) were 0. 143 and 0. 155% for sucrose and polarization in juice respectively. The predictive errors measured by FT-NIR were close to those by routine laboratory methods. The results demonstrated that the FT-NIR methods had high accuracy and they were able to replace the routine laboratory analysis. It was also demonstrated that as a rapid and accurate measurement, the FT-NIR technique had potential applications in quality control of mill sugarcane, establishment of payment system based on sugarcane quality, and selection of clones in sugarcane breeding. 展开更多
关键词 fourier transform near infrared spectroscopy Quantitative analysis SUGARCANE SUCROSE
下载PDF
Retrieval algorithm of quantitative analysis of passive Fourier transform infrared (FTRD) remote sensing measurements of chemical gas cloud from measuring the transmissivity by passive remote Fourier transform infrared 被引量:3
11
作者 刘志明 刘文清 +4 位作者 高闽光 童晶晶 张天舒 徐亮 魏秀丽 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第11期4184-4192,共9页
Passive Fourier transform infrared (FTIR) remote sensing measurement of chemical gas cloud is a vital technology. It takes an important part in many fields for the detection of released gases. The principle of conce... Passive Fourier transform infrared (FTIR) remote sensing measurement of chemical gas cloud is a vital technology. It takes an important part in many fields for the detection of released gases. The principle of concentration measurement is based on the Beer-Lambert law. Unlike the active measurement, for the passive remote sensing, in most cases, the difference between the temperature of the gas cloud and the brightness temperature of the background is usually a few kelvins. The gas cloud emission is almost equal to the background emission, thereby the emission of the gas cloud cannot be ignored. The concentration retrieval algorithm is quite different from the active measurement. In this paper, the concentration retrieval algorithm for the passive FTIR remote measurement of gas cloud is presented in detail, which involves radiative transfer model, radiometric calibration, absorption coefficient calculation, et al. The background spectrum has a broad feature, which is a slowly varying function of frequency. In this paper, the background spectrum is fitted with a polynomial by using the Levenberg-Marquardt method which is a kind of nonlinear least squares fitting algorithm. No background spectra are required. Thus, this method allows mobile, real-time and fast measurements of gas clouds. 展开更多
关键词 passive remote measurement fourier transform infrared ftir gas cloud sensing concentration retrieval
下载PDF
The role of fluid polarity in the swelling of sodium-montmorillonite clay:A molecular dynamics and Fourier transform infrared spectroscopy study 被引量:1
12
作者 Dinesh R.Katti Keshab B.Thapa Kalpana S.Katti 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2018年第6期1133-1144,共12页
Swelling clays are found extensively in various parts of the world, and sodium-montmorillonite(NaMMT) is the main constituent of an expansive clay mineral. In this work, the swelling behavior of NaMMT clay with a wide... Swelling clays are found extensively in various parts of the world, and sodium-montmorillonite(NaMMT) is the main constituent of an expansive clay mineral. In this work, the swelling behavior of NaMMT clay with a wide range of organic fluids, high polar through low polar fluids, is studied using a combination of Fourier transform infrared(FTIR) technique and molecular dynamics(MD) simulations.The construction of the representative clayefluid models is carried out, and the nature of nonbonded interactions between clay and fluids is studied using MD. Our FTIR and MD simulations results suggest the significant nonbonded interactions between Na-MMT clay and polar fluids, such as formamide and water. The nonbonded interactions of Na-MMT with methanol and acetone are significantly less than those in Na-MMT with polar fluids. The interactions of the fluids with various entities of the clay such as Sie O, Fee OH, Mge OH, and Ale OH captured via the spectroscopy experiments and modeling provide a finer understanding of the interactions and their contributions to swelling. The MD simulations are able to capture the band shifts observed in the spectra obtained in the spectroscopy experiments. This work also captures the conformations of interlayer sodium ions with formamide, water, methanol, and acetone during swelling. These nonbonded interactions provide insight into the molecular mechanism that the polarity of fluids plays an important role in the initiation of interlayer swelling, alteration in the orientations, and evolution of microstructure of swelling clays at the molecular scale. 展开更多
关键词 Swelling clays MONTMORILLONITE fourier transform infrared(ftir) technique Molecular dynamics(MD) Organic fluids Polarity
下载PDF
In vivo and in situ detection of colorectal cancer using Fourier transform infrared spectroscopy 被引量:3
13
作者 Qing-BoLi ZhiXu +9 位作者 Neng-WeiZhang LiZhang FanWang Li-MinYang Jian-ShengWang SuZhou Yuan-FuZhang Xiao-SiZhou Jing-SenShi Jin-GuangWu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第3期327-330,共4页
AIM: Real-time and rapid Identification of the malignant tissue can be performed during or before surgical operation. Here we aimed to detect in vivo and in situ colorectal cancer by using Fourier transform infrared (... AIM: Real-time and rapid Identification of the malignant tissue can be performed during or before surgical operation. Here we aimed to detect in vivo and in situ colorectal cancer by using Fourier transform infrared (FTIR) spectroscopy and fiber-optic technology. METHODS: A total of five patients with large intestine cancer were detected in vivo and in situ. Of them, three cases of colon cancer and one case of cecum cancer were detected intraoperatively and in vivo by using a FTIR spectrometer during surgical operation, and one case of rectum cancer was explored non-invasively and in vivo before the surgical operation. Normal and malignant colorectal tissues were detected in vivo and in situ using FTIR spectroscopy on the basis of fundamental studies. RESULTS: There were significant differences between FTIR spectra of normal and malignant colorectal tissues detected in vivo and in situ. Experimental results revealed that the spectral characteristics of normal and malignant tissues found in vivo and in situ were similar to those obtained from in vitro measurement in our previous fundamental research. CONCLUSION: FTIR fiber-optic attenuated total reflectance (ATR) spectroscopy can identify in situ and in vivo colorectal cancer. FTIR spectroscopie method with fiber optics is a non-invasive, rapid, accurate and in vivo cancer detection technique in clinical diagnosis. 展开更多
关键词 Colorectal cancer fourier transform infrared spectroscopy
下载PDF
A simple,sensitive and non-destructive technique for characterizing bovine dental enamel erosion:attenuated total reflection Fourier transform infrared spectroscopy 被引量:1
14
作者 In-Hye Kim Jun Sik Son +3 位作者 Bong Ki Min Young Kyoung Kim Kyo-Han Kim Tae-Yub Kwon 《International Journal of Oral Science》 SCIE CAS CSCD 2016年第1期54-60,共7页
Although many techniques are available to assess enamel erosion in vitro, a simple, non-destructive method with sufficient sensitivity for quantifying dental erosion is required. This study characterized the bovine de... Although many techniques are available to assess enamel erosion in vitro, a simple, non-destructive method with sufficient sensitivity for quantifying dental erosion is required. This study characterized the bovine dental enamel erosion induced by various acidic beverages in vitro using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. Deionized water (control) and 10 acidic beverages were selected to study erosion, and the pH and neutralizable acidity were measured. Bovine anterior teeth (110) were polished with up to 1 200-grit silicon carbide paper to produce flat enamel surfaces, which were then immersed in 20 mL of the beverages for 30 min at 37 ℃. The degree of erosion was evaluated using ATR-FTIR spectroscopy and Vickers' microhardness measurements. The spectra obtained were interpreted in two ways that focused on the ~1, ~3 phosphate contour: the ratio of the height amplitude of ~3 P04 to that of/11 P04 (Method 1) and the shift of the v3 P04 peak to a higher wavenumber (Method 2). The percentage changes in microhardness after the erosion treatments were primarily affected by the pH of the immersion media. Regression analyses revealed highly significant correlations between the surface hardness change and the degree of erosion, as detected by ATR-FTIR spectroscopy (P〈0.001). Method 1 was the most sensitive to these changes, followed by surface hardness change measurements and Method 2. This study suggests that ATR- FTIR spectroscopy is potentially advantageous over the microhardness test as a simple, non-destructive, sensitive technique for the quantification of enamel erosion. 展开更多
关键词 acidic beverage enamel erosion fourier transform infrared spectroscopy MICROHARDNESS sensitivity
下载PDF
Fourier Transform Infrared Spectroscopic Studies in Flotation 被引量:1
15
作者 龚文琪 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2001年第1期63-69,共7页
Fourier transform infrared (FTIR) spectroscopy has beenextensively employed in flotation research. The work done by theauthor and co-workers has been reported. A comparison has been madeamong the different FTIR spectr... Fourier transform infrared (FTIR) spectroscopy has beenextensively employed in flotation research. The work done by theauthor and co-workers has been reported. A comparison has been madeamong the different FTIR spectroscopic techniques, e.g., transmissionFTIR spectroscopy, diffuse reflectance infrared Fourier transform(DRIFT) spectroscopy, and attenuated total reflectance (ATR) FTIRspectroscopy. 展开更多
关键词 FLOTATION infrared spectroscopic study fourier transform
下载PDF
基于Fourier变换红外光谱分析咖啡豆成分
16
作者 于跃 胡长城 《吉林大学学报(理学版)》 CAS 北大核心 2024年第4期980-984,共5页
采用Fourier变换红外光谱对不同产区、不同海拔的5组浅中烘焙的咖啡豆样品进行分析,根据官能团的红外光谱特征峰分析样品主要成分;为进一步分析5组样品的成分差异,对原始光谱进行二阶导数处理,结合聚类分析理论建立平均偏离分析方法,计... 采用Fourier变换红外光谱对不同产区、不同海拔的5组浅中烘焙的咖啡豆样品进行分析,根据官能团的红外光谱特征峰分析样品主要成分;为进一步分析5组样品的成分差异,对原始光谱进行二阶导数处理,结合聚类分析理论建立平均偏离分析方法,计算出5组样品间的平均偏离大小并进行分析.结果表明:5组样品的红外光谱特征峰峰形相似,即主要成分相同;根据红外光谱得到平均偏离大小与产区海拔差值呈正相关.研究结果为分析咖啡豆产区和海拔提供鉴别依据,并对红外光谱研究提供一定参考. 展开更多
关键词 fourier变换红外光谱 平均偏离法 聚类分析 咖啡豆
下载PDF
COMP ARISON OF MACROMOLECULAR COMPONENT DISTRIBUTIONS IN OSTEOARTHRITIC AND HEALTHY CARTILAGES BY FOURIER TRANSFORM INFRARED IMAGING 被引量:1
17
作者 JIANHUA YIN YANG XIA ZHIYAN XIAO 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2013年第4期84-90,共7页
Fourier transform infrared imaging(FTIRI)was used to examine the depth-dependent content variations of macromolcular components,ollagen and protooglycan(PG),in osteoarthritic and healthy cartilages.Dried 6 pmm thick s... Fourier transform infrared imaging(FTIRI)was used to examine the depth-dependent content variations of macromolcular components,ollagen and protooglycan(PG),in osteoarthritic and healthy cartilages.Dried 6 pmm thick sections of canine knee cartilages were imaged at 6.25 pμrm pixel-size in FTIRI.By analyzing the infrared(IR)images and spectra,the depth dependence of characteristic band(sugar)intensity of PG show obvious difference bet ween the cartilage sections of(OA)and bealth.The result confimns that PG content decreases in the ostcoarthritic cartilage.However,no clear change occurs to collagen,suggesting that the OA influences little on the collagen content at early stage of OA.This observation will be helpful to further understand PG loss associated with pathological conditions in OA,and demonstrates that FIIRI has the po-tential to become an important analytical tool to identify early clinical signs of tissue degna-dation,such as PG loss even collagen disruption. 展开更多
关键词 Macromolecular component OSTEOARTHRITIS articular cartilage fourier transform infrared imaging(ftirI)
下载PDF
Quantitative Analysis of Lignocellulosic Components of Non-Treated and Steam Exploded Barley, Canola, Oat and Wheat Straw Using Fourier Transform Infrared Spectroscopy 被引量:1
18
作者 P. K. Adapa L. G. Tabil +2 位作者 G.J. Schoenau T. Canam T. Dumonceaux 《Journal of Agricultural Science and Technology(B)》 2011年第2期177-188,共12页
Rapid and cost effective quantification of lignocellulosic components (cellulose, hemicelluloses and lignin) of agricultural biomass (barley, canola, oat and wheat) is essential to determine the effect of various ... Rapid and cost effective quantification of lignocellulosic components (cellulose, hemicelluloses and lignin) of agricultural biomass (barley, canola, oat and wheat) is essential to determine the effect of various pre-treatments (such as steam explosion) on biomass used as feedstock for the biofuel industry. Fourier Transformed Infrared (FTIR) spectroscopy was considered as an option to achieve this objective. Regression equations having R2 values of 0.89, 0.99 and 0.98 were developed to predict the cellulose, hemicelluloses and lignin compounds of biomass, respectively. The average absolute difference in predicted and measured cellulose, hemicellulose and lignin in agricultural biomass was 7.5%, 2.5%, and 3.8%, respectively. 展开更多
关键词 fourier transformed infrared ftir photoacoustic spectroscopy LIGNIN cellulose hemicellulose.
下载PDF
Assessment of portable FTIR and Raman spectroscopy for the detection of 2,3-dimethyl-2,3-dinitrobutane(DMDNB)in plastic explosives
19
作者 Jacky Cailes Robert Dunsmore Kathryn L.Linge 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期11-18,共8页
The Marplex Convention was established to prevent the manufacture of unmarked plastic explosives and stipulates that a volatile detection agent must be added at the time of manufacture.However,to-date,laboratory testi... The Marplex Convention was established to prevent the manufacture of unmarked plastic explosives and stipulates that a volatile detection agent must be added at the time of manufacture.However,to-date,laboratory testing remains the internationally accepted practice for identifying and quantifying the taggants stipulated in the Convention.In this project,portable FTIR and Raman instruments were tested for their ability to detect 2,3-dimethyl-2,3-dinitrobutane(DMDNB),the chemical marker incorporated in plastic explosives that are manufactured within Australia.While both FTIR and Raman instruments detected solid DMDNB(98%purity),field analysis of plastic explosives at an Australian Defence establishment showed that both FTIR and Raman spectra were matched the relevant explosive(RDX or PETN),rather than the DMDNB taggant.For all three plastic explosives tested,the concentration of DMDNB was measured by SPME-GC-MS to be between 1.8 and 2%,greater than the minimum 1%concentration stipulated by the Marplex Convention.Additional testing with a plastic explosive analogue confirmed that the minor absorption peaks that would characterize low concentrations of DMDNB were masked by absorption bands from other compounds within the solid.Thus,while both FTIR and Raman spectroscopy are suitable for detection of plastic explosives,neither rely on the presence of DMDNB for detection.It is likely that similar results would be found for other taggants stipulated by the Marplex Convention,given they are also present in concentrations less than 1%. 展开更多
关键词 Explosive ICAO taggants 2 3-Dimethyl-2 3-dinitrobutane(DMDNB) fourier transform infrared(ftir) Raman
下载PDF
Comparative study on identi¯cation of healthy and osteoarthritic articular cartilages by fourier transform infrared imaging and chemometrics methods 被引量:1
20
作者 Zhi-Hua Mao Yue-Chao Wu +2 位作者 Xue-Xi Zhang Hao Gao Jian-Hua Yin 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第3期43-51,共9页
Two discriminant methods,partial least squares-discriminant analysis(PLS-DA)and Fisher's discriminant analysis(FDA),were combined with Fourier transform infrared imaging(FTIRI)to differentiate healthy and osteoart... Two discriminant methods,partial least squares-discriminant analysis(PLS-DA)and Fisher's discriminant analysis(FDA),were combined with Fourier transform infrared imaging(FTIRI)to differentiate healthy and osteoarthritic articular cartilage in a canine model.Osteoarthritic cartilage had been developed for up to two years after the anterior cruciate ligament(ACL)transection in one knee.Cartilage specimens were sectioned into 10μm thickness for FTIRI.A PLS-DA model was developed after spectral pre-processing.All IR spectra extracted from FTIR images were calculated by PLS-DA with the discriminant accuracy of 90%.Prior to FDA,principal component analysis(PCA)was performed to decompose the IR spectral matrix into informative princi pal component matrices.Based on the different discriminant mechanism,the discriminant accuracy(96%)of PCA-FDA with high convenience was higher than that of PLS-DA.No healthy cartilage sample was mis assigned by these two methods.The above mentioned suggested that both integrated technologies of FTIRI-PLS-DA and,especially,FTIRI-PCA-FDA could become a promising tool for the discrimination of healthy and osteoarthritic cartilage specimen as well as the diagnosis of cartilage lesion at microscopic level.The results of the study would be helpful for better understanding the pathology of osteoarthritics. 展开更多
关键词 Articular cartilage OSTEOARTHRITIS fourier transform infrared imaging partial least squares discriminant analysis Fisher's discriminant analysis.
下载PDF
上一页 1 2 132 下一页 到第
使用帮助 返回顶部