With the technique of Fourier transform near infrared (FT-NIR) spectroscopy, the calibration models for quantitative analysis of sucrose and polarization in sugarcane juice were developed by using transmission mode an...With the technique of Fourier transform near infrared (FT-NIR) spectroscopy, the calibration models for quantitative analysis of sucrose and polarization in sugarcane juice were developed by using transmission mode and calibrating with partial least square (PLS) algorithm. The determination coefficients (R2) of the predicted models for sucrose and polarization in juice were 0. 9980 and 0. 9979 respectively; the root mean square errors of cross validation (RMSECV) were 0. 143 and 0. 155% for sucrose and polarization in juice respectively. The predictive errors measured by FT-NIR were close to those by routine laboratory methods. The results demonstrated that the FT-NIR methods had high accuracy and they were able to replace the routine laboratory analysis. It was also demonstrated that as a rapid and accurate measurement, the FT-NIR technique had potential applications in quality control of mill sugarcane, establishment of payment system based on sugarcane quality, and selection of clones in sugarcane breeding.展开更多
In this paper,in vivo spectra from 23 patients'blood samples with various Creatinine(Cr)concentration levels ranging from 0.96 to 12.5 mg/dL were measured using Fourier transform near-infrared spectrometer(FT-NIRS...In this paper,in vivo spectra from 23 patients'blood samples with various Creatinine(Cr)concentration levels ranging from 0.96 to 12.5 mg/dL were measured using Fourier transform near-infrared spectrometer(FT-NIRS)and spectrum quantitative analysis method.Since Cr undergoes passive filtration,it serves as a key biomarker of kidneys function via the estimation of glomerular filtration rate.Thus,increased blood Cr concentration reflects impaired renal func-tion.After spectra pre processing and outlier exclusion,a spectral model was developed based on partial least squares regression(PLSR)method,wherein Cr concentrations correlated with filtered NIR spectra across several peaks,where Cr is know n to absorb NIR light.Several statistical metrics were applied to estimate the model efficiency during data analysis.Comparison of spectra-derived concentrations to reference Cr measurements by the current gold-standard Jaffe's method held in hospital lab revealed a Cr prediction accuracy of 1.64 mg/dL with good corre-lation of R=0.9.Bland-Altman plots were used to compare between our calculations and ref-erence lab values and reveal minimal bias between the two.The finding presented the potential of FT-NIRS coupled with PLSR technique for Cr determination.展开更多
文摘With the technique of Fourier transform near infrared (FT-NIR) spectroscopy, the calibration models for quantitative analysis of sucrose and polarization in sugarcane juice were developed by using transmission mode and calibrating with partial least square (PLS) algorithm. The determination coefficients (R2) of the predicted models for sucrose and polarization in juice were 0. 9980 and 0. 9979 respectively; the root mean square errors of cross validation (RMSECV) were 0. 143 and 0. 155% for sucrose and polarization in juice respectively. The predictive errors measured by FT-NIR were close to those by routine laboratory methods. The results demonstrated that the FT-NIR methods had high accuracy and they were able to replace the routine laboratory analysis. It was also demonstrated that as a rapid and accurate measurement, the FT-NIR technique had potential applications in quality control of mill sugarcane, establishment of payment system based on sugarcane quality, and selection of clones in sugarcane breeding.
文摘In this paper,in vivo spectra from 23 patients'blood samples with various Creatinine(Cr)concentration levels ranging from 0.96 to 12.5 mg/dL were measured using Fourier transform near-infrared spectrometer(FT-NIRS)and spectrum quantitative analysis method.Since Cr undergoes passive filtration,it serves as a key biomarker of kidneys function via the estimation of glomerular filtration rate.Thus,increased blood Cr concentration reflects impaired renal func-tion.After spectra pre processing and outlier exclusion,a spectral model was developed based on partial least squares regression(PLSR)method,wherein Cr concentrations correlated with filtered NIR spectra across several peaks,where Cr is know n to absorb NIR light.Several statistical metrics were applied to estimate the model efficiency during data analysis.Comparison of spectra-derived concentrations to reference Cr measurements by the current gold-standard Jaffe's method held in hospital lab revealed a Cr prediction accuracy of 1.64 mg/dL with good corre-lation of R=0.9.Bland-Altman plots were used to compare between our calculations and ref-erence lab values and reveal minimal bias between the two.The finding presented the potential of FT-NIRS coupled with PLSR technique for Cr determination.