The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatogra...The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatography with flame ionization detector (HS-GC-FID) has been developed and validated for the use in characterization of ethanol reference materials. The validation study was carried out in the linear calibration range 100 - 1500 mg/kg using the NIST SRM 2900, nominal 95.6%. The studied performance characteristics of the method were the limit of detection, LOD, the limit of quantification LOQ, selectivity, linearity, precision, recovery and bias. The validation results showed that the method is selective, precise, accurate and free from any significant bias. The LOD and LOQ were 1.27 and 3.86 mg/kg respectively and the estimated expanded uncertainty was 2% indicating that the method is fit for the purpose of certification of ethanol in water reference materials.展开更多
地面核磁共振(surface nuclear magnetic resonance,SNMR)技术是一种可直接定性定量探测地下水的非侵害式地球物理方法,已广泛应用于资源勘探、地质灾害预警和环境检测等方面。但在实际应用中,复杂的环境噪声导致微弱的SNMR信号常常被淹...地面核磁共振(surface nuclear magnetic resonance,SNMR)技术是一种可直接定性定量探测地下水的非侵害式地球物理方法,已广泛应用于资源勘探、地质灾害预警和环境检测等方面。但在实际应用中,复杂的环境噪声导致微弱的SNMR信号常常被淹没,很难获取有效的SNMR信号。针对这一问题,本文提出了一种基于差分结构的SNMR数据噪声压制技术,采用两个接收线圈等距设置在发射线圈上下位置。这种分布可以实时抵消大部分环境噪声以及消除收发线圈耦合影响。理论建模和仿真结果验证了新方法能够有效压制噪声,并可靠获取到早期自由感应衰减(free induction decay,FID)信号。展开更多
文摘The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatography with flame ionization detector (HS-GC-FID) has been developed and validated for the use in characterization of ethanol reference materials. The validation study was carried out in the linear calibration range 100 - 1500 mg/kg using the NIST SRM 2900, nominal 95.6%. The studied performance characteristics of the method were the limit of detection, LOD, the limit of quantification LOQ, selectivity, linearity, precision, recovery and bias. The validation results showed that the method is selective, precise, accurate and free from any significant bias. The LOD and LOQ were 1.27 and 3.86 mg/kg respectively and the estimated expanded uncertainty was 2% indicating that the method is fit for the purpose of certification of ethanol in water reference materials.