期刊文献+
共找到102篇文章
< 1 2 6 >
每页显示 20 50 100
A low-noise X-band microwave source with digital automatic frequency control for electron paramagnetic resonance spectroscopy
1
作者 贺羽 康润琪 +1 位作者 石致富 荣星 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期46-51,共6页
We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital auto... We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital automatic frequency control circuit can be flexibly configured for different experimental conditions,such as the input powers or the quality factors of the resonator.The configurability makes the microwave source universally compatible and greatly extends its application.To demonstrate the ability of adapting to various experimental conditions,the microwave source is tested by varying the input powers and the quality factors of the resonator.A satisfactory phase noise as low as-135 d Bc/Hz at 100-k Hz offset from the center frequency is achieved,due to the use of a phase-locked dielectric resonator oscillator and a direct digital synthesizer.Continuous-wave electron paramagnetic resonance experiments are conducted to examine the performance of the microwave source.The outstanding performance shows a prospect of wide applications of the microwave source in numerous fields of science. 展开更多
关键词 electron paramagnetic resonance X-BAND microwave source automatic frequency control
下载PDF
Distributed Model Predictive Load Frequency Control of Multi-area Power System with DFIGs 被引量:16
2
作者 Yi Zhang Xiangjie Liu Bin Qu 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第1期125-135,共11页
Reliable load frequency control(LFC) is crucial to the operation and design of modern electric power systems. Considering the LFC problem of a four-area interconnected power system with wind turbines, this paper prese... Reliable load frequency control(LFC) is crucial to the operation and design of modern electric power systems. Considering the LFC problem of a four-area interconnected power system with wind turbines, this paper presents a distributed model predictive control(DMPC) based on coordination scheme.The proposed algorithm solves a series of local optimization problems to minimize a performance objective for each control area. The generation rate constraints(GRCs), load disturbance changes, and the wind speed constraints are considered. Furthermore, the DMPC algorithm may reduce the impact of the randomness and intermittence of wind turbine effectively. A performance comparison between the proposed controller with and without the participation of the wind turbines is carried out. Analysis and simulation results show possible improvements on closed–loop performance, and computational burden with the physical constraints. 展开更多
关键词 Distributed model predictive control(DMPC) doubly fed induction generator(DFIG) load frequency control(LFC)
下载PDF
Robust H_∞ Load Frequency Control of Multi-area Power System With Time Delay:A Sliding Mode Control Approach 被引量:4
3
作者 Yonghui Sun Yingxuan Wang +2 位作者 Zhinong Wei Guoqiang Sun Xiaopeng Wu 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2018年第2期610-617,共8页
This paper is devoted to investigate the robust H∞sliding mode load frequency control(SMLFC) of multi-area power system with time delay. By taking into account stochastic disturbances induced by the integration of re... This paper is devoted to investigate the robust H∞sliding mode load frequency control(SMLFC) of multi-area power system with time delay. By taking into account stochastic disturbances induced by the integration of renewable energies,a new sliding surface function is constructed to guarantee the fast response and robust performance, then the sliding mode control law is designed to guarantee the reach ability of the sliding surface in a finite-time interval. The sufficient robust frequency stabilization result for multi-area power system with time delay is presented in terms of linear matrix inequalities(LMIs). Finally,a two-area power system is provided to illustrate the usefulness and effectiveness of the obtained results. 展开更多
关键词 Load frequency control(LFC) multi-area power system robust control sliding mode control(SMC) time delay
下载PDF
Addressing Frequency Control Challenges in Future Low-Inertia Power Systems:A Great Britain Perspective 被引量:2
4
作者 Qiteng Hong Md Asif Uddin Khan +3 位作者 Callum Henderson AgustíEgea-Àlvarez Dimitrios Tzelepis Campbell Booth 《Engineering》 SCIE EI 2021年第8期1057-1063,共7页
The ambitious global targets on decarbonization present the need for massive integration of renewable generation in power systems,resulting in a significant decrease in the system inertia.In addition to the reduction ... The ambitious global targets on decarbonization present the need for massive integration of renewable generation in power systems,resulting in a significant decrease in the system inertia.In addition to the reduction in system inertia,the transmission system in Great Britain(GB)faces some unique challenges owing to its relatively small capacity,while being decoupled from other transmission systems and with the renewable resources largely non-uniformly distributed across the system.This paper presents opinions and insights on the challenges associated with frequency control in a low-inertia system and the potential solutions from a GB perspective.In this paper,we focus on three main techniques that act over different time scales:synchronous condensers,inertia emulation,and fast frequency response.We evaluate their relative advantages and limitations with learnings from recent research and development projects in GB,along with the opinions on their roles in addressing the frequency control challenges in future low-inertia systems. 展开更多
关键词 Fast frequency control Inertia emulation Synchronous compensation Low-inertia systems
下载PDF
Multi-objective optimization for voltage and frequency control of smart grids based on controllable loads 被引量:2
5
作者 Yaxin Wang Donglian Qi Jianliang Zhang 《Global Energy Interconnection》 CAS CSCD 2021年第2期136-144,共9页
The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capabi... The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capability for nodal-power control.To maintain the system frequency and voltage magnitude around rated values,a new multi-objective optimization model for both voltage and frequency control is proposed.Moreover,a great similarity between the multiobjective optimization and game problems appears.To reduce the strong subjectivity of the traditional methods,the idea and method of the game theory are introduced into the solution.According to the present situational data and analysis of the voltage and frequency sensitivities to nodal-power variations,the design variables involved in the voltage and frequency control are classified into two strategy spaces for players using hierarchical clustering.Finally,the effectiveness and rationality of the proposed control are verified in MATLAB. 展开更多
关键词 Multi-objective optimization Voltage control frequency control Power flow controllable loads Game theory
下载PDF
Decentralized Resilient H_∞Load Frequency Control for Cyber-Physical Power Systems Under DoS Attacks 被引量:1
6
作者 Xin Zhao Suli Zou Zhongjing Ma 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2021年第11期1737-1751,共15页
This paper designs a decentralized resilient H_(∞)load frequency control(LFC)scheme for multi-area cyber-physical power systems(CPPSs).Under the network-based control framework,the sampled measurements are transmitte... This paper designs a decentralized resilient H_(∞)load frequency control(LFC)scheme for multi-area cyber-physical power systems(CPPSs).Under the network-based control framework,the sampled measurements are transmitted through the communication networks,which may be attacked by energylimited denial-of-service(DoS)attacks with a characterization of the maximum count of continuous data losses(resilience index).Each area is controlled in a decentralized mode,and the impacts on one area from other areas via their interconnections are regarded as the additional load disturbance of this area.Then,the closed-loop LFC system of each area under DoS attacks is modeled as an aperiodic sampled-data control system with external disturbances.Under this modeling,a decentralized resilient H_(∞)scheme is presented to design the state-feedback controllers with guaranteed H∞performance and resilience index based on a novel transmission interval-dependent loop functional method.When given the controllers,the proposed scheme can obtain a less conservative H_(∞)performance and resilience index that the LFC system can tolerate.The effectiveness of the proposed LFC scheme is evaluated on a one-area CPPS and two three-area CPPSs under DoS attacks. 展开更多
关键词 Cyber-physical power systems(CPPSs) denial-of-service(DoS)attacks load frequency control(LFC) sampled-data control
下载PDF
Load Frequency Control of Multi-interconnected Renewable Energy Plants Using Multi-Verse Optimizer 被引量:1
7
作者 Hegazy Rezk Mohamed A.Mohamed +1 位作者 Ahmed A.Zaki Diab N.Kanagaraj 《Computer Systems Science & Engineering》 SCIE EI 2021年第5期219-231,共13页
A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presente... A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presented in this paper.It has been applied for optimizing the control parameters of the load frequency controller(LFC)of the multi-source power system(MSPS).The MSPS includes thermal,gas,and hydro power plants for energy generation.Moreover,the MSPS is integrated with renewable energy sources(RES).The MVO algorithm is applied to acquire the ideal parameters of the controller for controlling a single area and a multi-area MSPS integrated with RES.HVDC link is utilized in shunt with AC multi-areas interconnection tie line.The proposed scheme has achieved robust performance against the disturbance in loading conditions,variation of system parameters,and size of step load perturbation(SLP).Meanwhile,the simulation outcomes showed a good dynamic performance of the proposed controller. 展开更多
关键词 Load frequency control multi-verse optimization multi-area power system renewable energy sources
下载PDF
Load Frequency Control of Small Hydropower Plants Using One-Input Fuzzy PI Controller with Linear and Non-Linear Plant Model 被引量:2
8
作者 Derek Ajesam Asoh Edwin Nyuysever Mbinkar Albert Nouck Moutlen 《Smart Grid and Renewable Energy》 2022年第1期1-16,共16页
<span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes... <span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes into account the non-linearity of SHPs—something which is not possible using traditional controllers. Most intelligent methods use two-</span><span style="font-family:;" "=""> </span><span style="font-family:;" "=""><span style="font-family:Verdana;">input fuzzy controllers, but because such controllers are expensive, there is </span><span style="font-family:Verdana;">economic interest in the relatively cheaper single-input controllers. A n</span><span style="font-family:Verdana;">on-</span></span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">linear control model based on one-input fuzzy logic PI (FLPI) controller was developed and applied to control the non-linear SHP. Using MATLAB/Si</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">mulink SimScape, the SHP was simulated with linear and non-linear plant models. The performance of the FLPI controller was investigated and compared with that of the conventional PI/PID controller. Results show that the settling time for the FLPI controller is about 8 times shorter;while the overshoot is about 15 times smaller compared to the conventional PI/PID controller. Therefore, the FLPI controller performs better than the conventional PI/PID controller not only in meeting the LFC control objective but also in ensuring increased dynamic stability of SHPs.</span> 展开更多
关键词 Small Hydropower Plant Linear and Non-Linear Model Load frequency control Non-Linear control Fuzzy Logic controller Renewable Energy
下载PDF
Distributed demand side management via smart appliances contributing to frequency control
9
作者 张玮琛 《Journal of Chongqing University》 CAS 2015年第3期101-108,共8页
Nowadays renewable energy has become a trend for energy production but its variable nature has made balancing of demand and supply of the power grid difficult. Dynamic demand management using smart appliances is propo... Nowadays renewable energy has become a trend for energy production but its variable nature has made balancing of demand and supply of the power grid difficult. Dynamic demand management using smart appliances is proposed to serve as a way that part of the regulation burden of balancing demand and supply is shifted to the demand side. However, if all appliances respond to the same frequency deviation, they may start to synchronize, causing large power overshoots and instability of the power grid. Therefore, the idea of implementing randomness into the frequency control of the appliances is proposed and this is what we call a stochastic approach. Simulators are built from scratch to model both scenarios. The effect of synchronization is analyzed and the parameters that can affect the synchronization are investigated. It has been found that the larger the contribution from the smart appliances to the power grid, the easier and faster the synchronization takes place. The stochastic approach solves the problem of synchronization and averages out the large power overshoot. However, the overall performance of stochastic operations is unacceptable due to the randomness in the operation though the mean and variance are as expected. More advanced feedback policies and schemes may be designed to achieve a better performance. 展开更多
关键词 renewable energy demand side smart grid smart appliance frequency control RANDOMNESS
下载PDF
Coefficient Diagram Method Based Load Frequency Control for a Modern Power System
10
作者 Princess Garasi Yaser Qudaih +2 位作者 Raheel Ali Masayuki Watanabe Yasunori Mitani 《Journal of Electronic Science and Technology》 CAS 2014年第3期270-276,共7页
increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the syste... increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the system stable. However, controllable or dispatchable loads such as electric vehicles (EVs) and heat pumps (HPs) can be utilized for supplementary frequency control. This paper shows the ability of plug-in hybrid EVs, HPs, and batteries (BTs) to contribute in the frequency control of an isolated power system. Moreover, we propose a new online intelligent approach by using a coefficient diagram method (CDM) to enhance the system performance and robustness against uncertainties. The performance of the proposed intelligent CDM control has been compared with the proportional-integral (PI) controller and the superiority of the proposed scheme has been verified in Matiab/Simulink programs. 展开更多
关键词 BATTERY coefficient diagram method electric vehicles heat pump load frequency control renewable energy sources.
下载PDF
Kalman-Filtering-Based Frequency Control Strategy Considering Electrolytic Aluminum Load
11
作者 Yuqin Chen Shihai Yang +1 位作者 Yueping Kong Mingming Chen 《Energy Engineering》 EI 2022年第4期1517-1529,共13页
Traditional thermal power units are continuously replaced by renewable energies,of which fluctuations and intermittence impose pressure on the frequency stability of the power system.Electrolytic aluminum load(EAL)acc... Traditional thermal power units are continuously replaced by renewable energies,of which fluctuations and intermittence impose pressure on the frequency stability of the power system.Electrolytic aluminum load(EAL)accounts for large amount of the local electric loads in some areas.The participation of EAL in local frequency control has huge application prospects.However,the controller design of EAL is difficult due to the measurement noise of the system frequency and the nonlinear dynamics of the EAL’s electric power consumption.Focusing on this problem,this paper proposes a control strategy for EAL to participate in the frequency control.For the controller design of the EAL system,the system frequency response model is established and the EAL transfer function model is developed based on the equivalent circuit of EAL.For the problem of load-side frequency measurement error,the frequency estimation method based on Kalman-filtering is designed.To improve the performance of EAL in the frequency control,a fuzzy EAL controller is designed.The testing examples show that the designed Kalman-filter has good performance in de-noising the measured frequency,and the designed fuzzy controller has better performance in stabilizing system frequency than traditional methods. 展开更多
关键词 Electrolytic aluminum load kalman-filtering frequency control
下载PDF
Direct Digital Frequency Control Based on the Phase Step Change Characteristic between Signals
12
作者 贾兆旻 杨旭海 +3 位作者 孙保琪 周晓平 向波 窦新宇 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第9期29-32,共4页
We present a new digital phase lock technology to achieve the frequency control and transformation through high precision multi-cycle group synchronization between signals without the frequency transformation circuit.... We present a new digital phase lock technology to achieve the frequency control and transformation through high precision multi-cycle group synchronization between signals without the frequency transformation circuit. In the case of digital sampling, the passing zero point of the phase of the controlled signal has the phase step characteristic, the phase step of the passing zero point is monotonic continuous with high resolution in the phase lock process, and using the border effect of digital fuzzy area, the gate can synchronize with the two signals, the quantization error is reduced. This technique is quite different from the existing methods of frequency transformation and frequency synthesis, the phase change characteristic between the periodic signals with different nominal is used. The phase change has the periodic phenomenon, and it has the high resolution step value. With the application of the physical law, the noise is reduced because of simplifying frequency transformation circuits, and the phase is locked with high precision. The regular phase change between frequency signals is only used for frequency measurement, and the change has evident randomness, but this randomness is greatly reduced in frequency control, and the certainty of the process result is clear. The experiment shows that the short term frequency stability can reach 10-12/s orders of magnitude. 展开更多
关键词 Direct Digital frequency control Based on the Phase Step Change Characteristic between Signals
下载PDF
Application of Frequency Control Technique to a Rotary Drill
13
作者 YAO Can-yang 《International Journal of Plant Engineering and Management》 2009年第1期38-42,共5页
The scheme of a frequency control system in a rotary drill is established by integrating a converter and a programmable logic controller ( PLC ). The principle of speed regulation, characters of speed-up and speed-d... The scheme of a frequency control system in a rotary drill is established by integrating a converter and a programmable logic controller ( PLC ). The principle of speed regulation, characters of speed-up and speed-down, and the mechanical running performance are also analyzed. The result of application indicates that the frequency control system excellently solves the problems of start, stop, and speed regulation of the drill. The equipment maintenance workload and cost are thus reduced. 展开更多
关键词 rotary drill frequency control PLC MOTOR
下载PDF
Integral Performance Criteria Based Analysis of Load Frequency Control in Bilateral Based Market
14
作者 P. Anitha P. Subburaj 《Circuits and Systems》 2016年第6期1021-1032,共12页
Performance index based analysis is made to examine and highlight the effective application of Particle Swarm Optimization (PSO) to optimize the Proportional Integral gains for Load Frequency Control (LFC) in a restru... Performance index based analysis is made to examine and highlight the effective application of Particle Swarm Optimization (PSO) to optimize the Proportional Integral gains for Load Frequency Control (LFC) in a restructured power system that operates under Bilateral based policy scheme. Various Integral Performance Criteria measures are taken as fitness function in PSO and are compared using overshoot, settling time and frequency and tie-line power deviation following a step load perturbation (SLP). The motivation for using different fitness technique in PSO is to show the behavior of the controller for a wide range of system parameters and load changes. Error based analysis with parametric uncertainties and load changes are tested on a two-area restructured power system. The results of the proposed PSO based controller show the better performance compared to the classical Ziegler-Nichols (Z-N) tuned PI and Fuzzy Rule based PI controller. 展开更多
关键词 Load frequency control Particle Swarm Optimization Bilateral Market Area control Error Fuzzy Rule Based PI controller Parametric Uncertainties
下载PDF
A Novel Flower Pollination Algorithm to Solve Load Frequency Control for a Hydro-Thermal Deregulated Power System
15
作者 D. Lakshmi A. Peer Fathima Ranganath Muthu 《Circuits and Systems》 2016年第4期166-178,共13页
Load frequency control plays a vital role in power system operation and control. LFC regulates the frequency of larger interconnected power systems and keeps the net interchange of power between the pool members at pr... Load frequency control plays a vital role in power system operation and control. LFC regulates the frequency of larger interconnected power systems and keeps the net interchange of power between the pool members at predetermined values for the corresponding changes in load demand. In this paper, the two-area, hydrothermal deregulated power system is considered with Redox Flow Batteries (RFB) in both the areas. RFB is an energy storage device, which converts electrical energy into chemical energy, that is used to meet the sudden requirement of real power load and hence very effective in reducing the peak shoots. With conventional proportional-integral (PI) controller, it is difficult to get the optimum solution. Hence, intelligent techniques are used to tune the PI controller of the LFC to improve the dynamic response. In the family of intelligent techniques, a recent nature inspired algorithm called the Flower Pollination Algorithm (FPA) gives the global minima solution. The optimal value of the controller is determined by minimizing the ISE. The results show that the proposed FPA tuned PI controller improves the dynamic response of the deregulated system faster than the PI controller for different cases. The simulation is implemented in MATLAB environment. 展开更多
关键词 Load frequency control Redox Flow Battery Proportional Integral controller Flower Pollination Algorithm
下载PDF
Ant Lion Optimization Approach for Load Frequency Control of Multi-Area Interconnected Power Systems
16
作者 R. Satheeshkumar R. Shivakumar 《Circuits and Systems》 2016年第9期2357-2383,共27页
This work proposes a novel nature-inspired algorithm called Ant Lion Optimizer (ALO). The ALO algorithm mimics the search mechanism of antlions in nature. A time domain based objective function is established to tune ... This work proposes a novel nature-inspired algorithm called Ant Lion Optimizer (ALO). The ALO algorithm mimics the search mechanism of antlions in nature. A time domain based objective function is established to tune the parameters of the PI controller based LFC, which is solved by the proposed ALO algorithm to reach the most convenient solutions. A three-area interconnected power system is investigated as a test system under various loading conditions to confirm the effectiveness of the suggested algorithm. Simulation results are given to show the enhanced performance of the developed ALO algorithm based controllers in comparison with Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Bat Algorithm (BAT) and conventional PI controller. These results represent that the proposed BAT algorithm tuned PI controller offers better performance over other soft computing algorithms in conditions of settling times and several performance indices. 展开更多
关键词 Load frequency control (LFC) Multi-Area Power System Proportional-Integral (PI) controller Ant Lion Optimization (ALO) Bat Algorithm (BAT) Genetic Algorithm (GA) Particle Swarm Optimization (PSO)
下载PDF
Steady-state Voltage Security-constrained Optimal Frequency Control for Weak HVDC Sending-end AC Power Systems
17
作者 Qiangqiang Wang Liangzhong Yao +3 位作者 Jian Xu Yuping Zheng Wei Li Wei Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期658-669,共12页
Due to the fact that a high share of renewable energy sources(RESs)are connected to high-voltage direct current(HVDC)sending-end AC power systems,the voltage and frequency regulation capabilities of HVDC sending-end A... Due to the fact that a high share of renewable energy sources(RESs)are connected to high-voltage direct current(HVDC)sending-end AC power systems,the voltage and frequency regulation capabilities of HVDC sending-end AC power systems have diminished.This has resulted in potential system operating problems such as overvoltage and overfrequency,which occur simultaneously when block faults exist in the HVDC link.In this study,a steady-state voltage security-constrained optimal frequency control method for weak HVDC sending-end AC power systems is proposed.The integrated virtual inertia control of RESs is employed for system frequency regulation.Additional dynamic reactive power compensation devices are utilized to control the voltage of all nodes meet voltage security constraints.Then,an optimization model that simultaneously considers the frequency and steady-state voltage security constraints for weak HVDC sending-end AC power systems is established.The optimal control scheme with the minimum total cost of generation tripping and additional dynamic reactive power compensation required is obtained through the optimization solution.Simulations are conducted on a modified IEEE 9-bus test system and practical Qing-Yu line commutated converter based HVDC(LCC-HVDC)sending-end AC power system to verify the effectiveness of the proposed method. 展开更多
关键词 Renewable energy source(RES) high-voltage direct current(HVDC) AC power system optimal frequency control steady-state voltage security dynamic reactive power compensation
原文传递
Robust Load Frequency Control for Isolated Microgrids Based on Double-loop Compensation
18
作者 Yang Mi Yuchen Ma +5 位作者 Xingtang He Xingwu Yang Jinxia Gong Yao Zhao Ronghui Liu Wei Wei 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第4期1359-1369,共11页
Frequency is an important indicator for the oper-ation of microgrids.However,the randomness and uncertainty of renewable energy and load variability may lead to frequency undulation.So,a robust load frequency control(... Frequency is an important indicator for the oper-ation of microgrids.However,the randomness and uncertainty of renewable energy and load variability may lead to frequency undulation.So,a robust load frequency control(LFC)is pro-posed for isolated wind-diesel microgrids considering time delay and parameter uncertainty.The control strategy can suppress frequency fuctuation and optimize frequency dynamic response.First,the double compensation loop,including feedforward control and integral sliding mode control(SMC),is devised to provide anti-disturbance compensation for the diesel generator system and ameliorate the frequency stability of independent microgrids.Secondly,a dynamic fuzzy controller,composed of wind speed and load demand,is designed to provide real-time response reference power for doubly fed induction generator systems(DFIGs),which can promote the effective participation of a wind turbine system for frequency regulation.Then,the proportional differential(PD)parameters of a dynamic fuzzy controller and the frequency adjustment compensation of DFIGs can be obtained by using a particle swarm optimization(PSO)algorithm.Thirdly,load demand is an important index of the robust dynamic load frequency control method;the radial basis function(RBF)neural network observer(NNO)based on the LFC model is presented to obtain more accurate load deviations and improve the control precision of LFC.The performance of the proposed LFC method is tested under different operation cases.Index Terms-Load frequency control,microgrid,neural network observer,sliding mode,time delay and parameter uncertainty. 展开更多
关键词 Load frequency control MICROGRID neural network observer sliding mode time delay and parameter uncertainty.
原文传递
Adaptive H_(∞) event-triggered load frequency control in islanded microgirds with limited spinning reserve constraints
19
作者 Yajian Zhang Chen Peng 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第2期231-243,共13页
Using an islanded microgrid(MG)with large-scale integration of renewable energy is the most popular way of solving the reliable power supply problem for remote areas and critical electrical users.However,compared with... Using an islanded microgrid(MG)with large-scale integration of renewable energy is the most popular way of solving the reliable power supply problem for remote areas and critical electrical users.However,compared with traditional power systems,the limited spinning reserves and network communication bandwidth may cause weak frequency stability in the presence of stochastic renewable active outputs and load demand fluctuations.In this paper,an adap-tive event-triggered control(ETC)strategy for a load frequency control(LFC)system in an islanded MG is proposed.First,a bounded adaptive event-triggered communication scheme is designed.This not only saves on network resources,but also ensures that the control center has a sensitive monitoring ability for the MG operating status when the frequency deviations have been effectively damped.Secondly,by fully considering the spinning reserve con-straints and uncertain communication delays,the LFC system is described as a nonlinear model with saturation terms.Design criteria for ETC parameters are strictly deduced based on Lyapunov stability theory.Finally,an ETC parameter optimization algorithm based on random direction search is developed to reconcile the bandwidth occupancy and control performance.The effectiveness of the proposed method is verified in an MG test system. 展开更多
关键词 MICROGRID Load frequency control Event-triggered control Nonlinear saturation Time delay
原文传递
Effective participation of wind turbines in frequency control of a two-area power system using coot optimization
20
作者 Mahmoud Hussain El-Bahay Mohammed Elsayed Lotfy Mohamed A.El-Hameed 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第1期230-244,共15页
In this paper,load frequency control is performed for a two-area power system incorporating a high penetration of renewable energy sources.A droop controller for a type 3 wind turbine is used to extract the stored kin... In this paper,load frequency control is performed for a two-area power system incorporating a high penetration of renewable energy sources.A droop controller for a type 3 wind turbine is used to extract the stored kinetic energy from the rotating masses during sudden load disturbances.An auxiliary storage controller is applied to achieve effec-tive frequency response.The coot optimization algorithm(COA)is applied to allocate the optimum parameters of the fractional-order proportional integral derivative(FOPID),droop and auxiliary storage controllers.The fitness function is represented by the summation of integral square deviations in tie line power,and Areas 1 and 2 frequency errors.The robustness of the COA is proven by comparing the results with benchmarked optimizers including:atomic orbital search,honey badger algorithm,water cycle algorithm and particle swarm optimization.Performance assessment is confirmed in the following four scenarios:(i)optimization while including PID controllers;(ii)optimization while including FOPID controllers;(iii)validation of COA results under various load disturbances;and(iv)validation of the proposed controllers under varying weather conditions. 展开更多
关键词 Coot optimizer FOPID Load frequency control PHOTOVOLTAIC Variable speed wind turbine
原文传递
上一页 1 2 6 下一页 到第
使用帮助 返回顶部