期刊文献+
共找到995篇文章
< 1 2 50 >
每页显示 20 50 100
Generation of Continuous-Wave 194 nm Laser for Mercury Ion Optical Frequency Standard 被引量:4
1
作者 邹宏新 伍越 +2 位作者 陈国柱 沈咏 刘曲 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第5期73-77,共5页
A 194-nm cw laser is an essential part in the mercury ion optical frequency standard. We report the generation of over 2mW continuous-wave radiation at 194nm in a beta barium borate crystal using a simple sum frequenc... A 194-nm cw laser is an essential part in the mercury ion optical frequency standard. We report the generation of over 2mW continuous-wave radiation at 194nm in a beta barium borate crystal using a simple sum frequency mixing (SFM) system. One source beams at 718nm is resonantly enhanced with a cavity and the other at 266mn makes a single pass. Considering the walk-off effect in SFM, the source beam waists are designed to be elliptical, thus the conversion efficiency can be promoted. The 266-nm beam produced by frequency doubling of 532-nm laser is shaped close to the diffraction limit to achieve better mode matching. 展开更多
关键词 Generation of Continuous-Wave 194 nm Laser for Mercury Ion Optical frequency standard BBO SFM
下载PDF
Optimal Microwave Radiation Field Parameters for Mercury Ion Microwave Frequency Standards 被引量:2
2
作者 杨智慧 柳浩 +5 位作者 何跃宏 汪漫 万涌泉 陈义和 佘磊 李交美 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第6期21-24,共4页
We propose a method to determine the optimal power of the microwave resonance transition that simultaneously improves the signal-to-noise ratio and reduces line width based on saturation broadening theory and experime... We propose a method to determine the optimal power of the microwave resonance transition that simultaneously improves the signal-to-noise ratio and reduces line width based on saturation broadening theory and experiment. Saturation broadening spectra of the ground state hyperfine transition of trapped 199Hg+ ions are measured and analyzed. The value of the optimal microwave power is obtained by using the proposed method and is verified. Rabi oscillations decay spectra of trapped 199Hg+ ions are observed and the optimal microwave irradiation time for the maximum transition signal intensity is determined. This work will help to improve the short-term frequency stability of the mercury ion microwave frequency standard. 展开更多
关键词 of on IT Optimal Microwave Radiation Field Parameters for Mercury Ion Microwave frequency standards DBM IS for
下载PDF
Dual-Wavelength Bad Cavity Laser as Potential Active Optical Frequency Standard 被引量:2
3
作者 许志超 潘多 +1 位作者 庄伟 陈景标 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期31-34,共4页
We experimentally realize the dual-wavelength bad cavity laser for the first time. As the Cs cell temperature is kept between 118℃ and 144℃, both the 1359nm and 147Ohm lasing outputs of dual-wavelength bad cavity la... We experimentally realize the dual-wavelength bad cavity laser for the first time. As the Cs cell temperature is kept between 118℃ and 144℃, both the 1359nm and 147Ohm lasing outputs of dual-wavelength bad cavity laser are detected. The laser output power of dual-wavelength bad cavity laser is measured when changing the 455 nm pumping laser frequency and power at 127℃ Cs cell temperature. Both the 1359 nm laser and the 1470 nm laser are working at the deep bad cavity regime, and the ratio between the linewidth of cavity mode and the laser gain bandwidth a ≈ 40 for 1359nm and 1470nm lasers. The 147Ohm laser linewidth is measured to be 407.3Hz. The dual-wavelength bad cavity laser operating on atomic transitions demonstrated here has a potential in the application as a stable optical local oscillator, even an active optical frequency standard directly in the future. 展开更多
关键词 Dual-Wavelength Bad Cavity Laser as Potential Active Optical frequency standard AS Cs length
下载PDF
A 532 nm molecular iodine optical frequency standard based on modulation transfer spectroscopy 被引量:2
4
作者 程飞虎 金宁 +5 位作者 张风雷 李慧 杜远博 张洁 邓科 陆泽晃 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期277-286,共10页
We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s ave... We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s averaging time is achieved,and the frequency reproducibility has a relative uncertainty of 3.5×10^(-13),demonstrating the great stability of our setup.The systematic uncertainty of the iodine-stabilized laser frequency standard is evaluated,especially the contribution of the residual amplitude modulation(RAM).The contribution of the RAM in MTS cannot be evaluated directly.To solve this problem,we theoretically deduce the MTS signal with RAM under large modulation depth,and prove that the non-symmetric shape of the MTS signal is directly related to the MTS effect.The non-symmetric shape factor can be calibrated with a frequency comb,and in real experiments,this value can be obtained by least-squares fitting of the MTS signal,from which we can infer the RAMinduced frequency shift.The full frequency uncertainty is evaluated to be 5.3 kHz(corresponding to a relative frequency uncertainty of 9.4×10^(-12)).The corrected transition frequency has a difference from the BIPM-recommended value of 2 kHz,which is within 1σ uncertainty,proving the validity of our evaluation. 展开更多
关键词 iodine-stabilized laser frequency standard modulation transfer spectroscopy residual amplitude modulation
下载PDF
Experimental Scheme of 633 nm and 1359 nm Good-Bad Cavity Dual-Wavelength Active Optical Frequency Standard 被引量:3
5
作者 许志超 潘多 +1 位作者 庄伟 陈景标 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第8期57-61,共5页
The experimental scheme of 633 nm and 1359 nm good-bad cavity dual-wavelength active optical frequency stan- dard is proposed, where He-Ne 633nm and Cs 1359nm stimulated emissions are working at good-cavity and bad-ca... The experimental scheme of 633 nm and 1359 nm good-bad cavity dual-wavelength active optical frequency stan- dard is proposed, where He-Ne 633nm and Cs 1359nm stimulated emissions are working at good-cavity and bad-cavity regimes, respectively. The cavity length is stabilized by locking the 633nm output frequency to a super-cavity with the Pound Drever-Hall (PDH) technique. The frequency stability of 1359 nm bad-cavity stim- ulated emission output is then expected to be further improved by at least 1 order of magnitude than the 633nm PDH system due to the suppressed cavity pulling effect of active optical clock, and the quantum limited linewidth of 1359nm output is estimated to be 72.5 mHz. 展开更多
关键词 length Experimental Scheme of 633 nm and 1359 nm Good-Bad Cavity Dual-Wavelength Active Optical frequency standard
下载PDF
The time and frequency standard system for FAST receivers 被引量:1
6
作者 朱凯 范瑾 +16 位作者 Kun Liang Wei Tang Zhi-Sheng Gao Yan Zhu Yi Feng Wei-Wei Zhu Lei Qian You-Ling Yue Jin-You Song Xiang-Wei Shi Xing-Yi Wang Ming-Lei Guo Hang Zhang Heng-Qian Gan Hong-Fei Liu Cheng-Jin Jin Peng Jiang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2020年第5期148-154,共7页
This paper reports on the time and frequency standard system for the Five-hundred meter Aperture Spherical radio Telescope(FAST),including the system design,stability measurements and pulsar timing observations.The st... This paper reports on the time and frequency standard system for the Five-hundred meter Aperture Spherical radio Telescope(FAST),including the system design,stability measurements and pulsar timing observations.The stability and drift rate of the frequency standard are calculated using 1-year monitoring data.The UTC-NIM Disciplined Oscillator(NIMDO)system improves the system time accuracy and stability to the level of 5 ns.Pulsar timing observations were carried out for several months.The weighted RMS of timing residuals reaches the level of less than 3.0μs. 展开更多
关键词 FAST:radio telescope time frequency standard NIMDO:UTC-NIM
下载PDF
Improvement of Laser Frequency Stabilization for the Optical Pumping Cesium Beam Standard 被引量:2
7
作者 王青 段俊 +2 位作者 齐向晖 张胤 陈徐宗 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第5期69-72,共4页
A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an import... A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an important factor that limits the long-term frequency stability. We minimize the drift of the light angle by using a fiber- coupled output, and lock the frequency of a distributed-feedback diode laser to the fluorescence spectrum of the atomic beam. The measured frequency stability is about 3.5 ×10^-11 at i s and reaches 1.5 × 10^-12 at 2000s. The Allan variance keeps going down for up to thousands of seconds, indicating that the medium- and long-term stability of the laser frequency is significantly improved and perfectly fulfills the requirement for the optical pumping cesium clock. 展开更多
关键词 Improvement of Laser frequency Stabilization for the Optical Pumping Cesium Beam standard
下载PDF
Computed Tidal Relativistic Red-Shifts of Frequency Standards on Earth and in Space Stations 被引量:2
8
作者 庄伟 房芳 +2 位作者 王少凯 赵阳 李天初 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第11期11-14,共4页
Frequencies of frequency standards are shifted by the local static gravity red shifts and also modulated by the tidal relativistic red shifts. We compute the tidal relativistic red shifts using a time-domain method an... Frequencies of frequency standards are shifted by the local static gravity red shifts and also modulated by the tidal relativistic red shifts. We compute the tidal relativistic red shifts using a time-domain method and present the numerical results for the National Institute of Metrology (NIM) in Beijing, Laboratoire National de Metrologie et Essais-Systeme de References Temps-Espaee (LNE-SYRTE) in Paris and Physikalisch-Teehnische Bundesanstalt (PTB) in Braunschweig. The differences of the tidal relativistic red shift approach as large as 1.1 × 10^-16 when frequency standards at NIM are compared with those at SYRTE and PTB. Moreover, the tidal relativistic red shifts of frequency standards in space stations are also computed. 展开更多
关键词 Computed Tidal Relativistic Red-Shifts of frequency standards on Earth and in Space Stations
下载PDF
Progress of the NTSC-F1 primary frequency standard 被引量:1
9
作者 RUAN Jun WANG Xinliang +7 位作者 LIU Dandan GUAN Yong ZHANG Hui CHEN Jiang LIN Rui YU Fengxiang SHI Junru ZHANG Shougang 《Instrumentation》 2015年第4期16-27,共12页
The SI "second"is realized by caesium primary frequency standards( PFSs) using laser cooled atoms in a fountain configuration. Four sub systems and operation procedure of the NTSC-F1 primary frequency standa... The SI "second"is realized by caesium primary frequency standards( PFSs) using laser cooled atoms in a fountain configuration. Four sub systems and operation procedure of the NTSC-F1 primary frequency standard are introduced in the paper.The frequency stability of NTSC-F1 is 3.0×10-13/ τ-1 / 2compared to hydrogen maser. Four terms of frequency shift and uncertainty including second order Zeeman frequency shift,cold collision shift,gravity shift and blackbody shift are evaluated. The improvement of NTSC-F1 is introduced. 展开更多
关键词 PRIMARY frequency standard frequency stability frequency uncertainty.
下载PDF
A 420nm Blue Diode Laser for the Potential Rubidium Optical Frequency Standard
10
作者 张盛楠 张晓刚 +6 位作者 涂建辉 蒋招杰 商浩森 祝传文 杨炜 崔敬忠 陈景标 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第7期118-121,共4页
We report a 42Ohm external cavity diode laser with an interference filter (IF) of 0.5am narrow-bandwidth and 79% high transmission, which is first used for Rb optical frequency standard. The IF and the cat-eye refle... We report a 42Ohm external cavity diode laser with an interference filter (IF) of 0.5am narrow-bandwidth and 79% high transmission, which is first used for Rb optical frequency standard. The IF and the cat-eye reflector are used for selecting wavelength and light feedback, respectively. The measured laser linewidth is 24 kHz when the diode laser is free running. Using this narrow-linewidth IF blue diode laser, we realize a compact Rb optical frequency standard without a complicated PDH system. The preliminary stability of the Rb optical frequency standard is 2 × 10^-13 at I s and decreases to 1.9 ×10^-14 at 1000s. The narrow-linewidth characteristic makes the IF blue diode laser a well suited candidate for the compact Rb optical frequency standard. 展开更多
关键词 A 420nm Blue Diode Laser for the Potential Rubidium Optical frequency standard RB KHZ
下载PDF
Dick Effect in a Microwave Frequency Standard Based on Laser-Cooled 113Cd+ Ions
11
作者 张建伟 缪凯 王力军 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第1期27-29,共3页
The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion dock operated in pulsed mode which require unavoidable dead time during i... The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion dock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113^Cd+ ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion dock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps. 展开更多
关键词 Dick Effect in a Microwave frequency standard Based on Laser-Cooled
下载PDF
A diode laser spectrometer at 634 nm and absolute frequency measurements using optical frequency comb 被引量:1
12
作者 伊林 袁杰 +5 位作者 齐向晖 陈文兰 周大伟 周通 周小计 陈徐宗 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第4期1409-1412,共4页
This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the... This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the Doppler-free absorption signals using the third-harmonic detection technique. The instability of the stabilized laser is measured to be 2.8 × 10^-12 (after 1000 s) by counting the beat note between the two lasers. The absolute optical frequency of the transition is, for the first time, determined to be 472851936189.5 kHz by using an optical frequency comb referenced on the microwave caesium atomic clock. The uncertainty of the measurement is less than 4.9 kHz. 展开更多
关键词 frequency standard optical frequency comb absolute frequency measurement atomicclock
下载PDF
Investigation on Frequency Stirring in Reverberation Chamber 被引量:2
13
作者 CHENG Erwei WANG Qingguo LIU Yifei XU Xin 《高电压技术》 EI CAS CSCD 北大核心 2014年第3期951-956,共6页
关键词 高电压技术 高压安全 高压试验 避雷设施
下载PDF
Novel Frequency Hopping Sequences Generator Based on AES Algorithm 被引量:2
14
作者 李振荣 庄奕琪 +1 位作者 张博 张超 《Transactions of Tianjin University》 EI CAS 2010年第1期22-27,共6页
A novel frequency hopping(FH) sequences generator based on advanced encryption standard(AES) iterated block cipher is proposed for FH communication systems.The analysis shows that the FH sequences based on AES algorit... A novel frequency hopping(FH) sequences generator based on advanced encryption standard(AES) iterated block cipher is proposed for FH communication systems.The analysis shows that the FH sequences based on AES algorithm have good performance in uniformity, correlation, complexity and security.A high-speed, low-power and low-cost ASIC of FH sequences generator is implemented by optimizing the structure of S-Box and MixColumns of AES algorithm, proposing a hierarchical power management strategy, and applying the dynamic clock gating technology based on finite state machine and clock gating.SMIC 0.18 μm standard CMOS technology shows that the scale of ASIC is only about 10.68 kgate, power consumption is 33.8 μW/MHz, and the maximum hop-rate is 1 098 901 hop/s.This design is suitable for portable FH communication system for its advantages in high-security and hop-rate, low-power and low-cost.The proposed FH sequences generator has been employed in Bluetooth SoC design. 展开更多
关键词 频率跳跃序列 先进加密标准 低力量 便宜 申请特定的集成电路
下载PDF
Breast Lump Recognition Algorithms Based on Ultrasound Radio-Frequency Signals
15
作者 YAN Yu CAI Xiaowei +2 位作者 ZHU Wei CAI Runqiu WU Yiyun 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第4期635-640,共6页
A method for evaluating the benign and malignant breast tumors based on radio?frequency(RF)data was explored by extracting the characteristic parameters of breast ultrasound RF signals.The breast biopsy data were used... A method for evaluating the benign and malignant breast tumors based on radio?frequency(RF)data was explored by extracting the characteristic parameters of breast ultrasound RF signals.The breast biopsy data were used as the reference data for judging the lump benign or malignant.The extracted ultrasound RF data were reconstructed and segmented by computer aided method to obtain the breast tumor region of interest(ROI)and its characteristic parameters(entropy and standard deviation).The characteristic parameters were statistically analyzed to evaluate the relationship between characteristic parameters and benign or malignant breast tumors.The results indicate the entropy and standard deviation of normal region is much higher than that of lump region,which shows that the standard deviation and entropy characteristic parameters of ultrasonic RF signals are meaningful in the diagnosis of breast tumors.The proposed method provides a new direction for computer?aided diagnosis of benign and malignant breast tumors. 展开更多
关键词 ultrasound radio‑frequency signal breast lump signal processing standard deviation ENTROPY
下载PDF
Value of High-Frequency Relic Gravitational Wave (HFRGW) Detection to Astrophysics and Fabrication and Utilization of the Li-Baker HFRGW Detector 被引量:2
16
作者 Andrew Walcott Beckwith Robert M. L. Baker Jr 《Journal of High Energy Physics, Gravitation and Cosmology》 2020年第1期103-122,共20页
Up to the present time gravitational-wave detectors, such as LIGO and Virgo, have been sensitive to frequencies on the order of a few thousand to a small fraction of an Hz. They have been most effective in the study o... Up to the present time gravitational-wave detectors, such as LIGO and Virgo, have been sensitive to frequencies on the order of a few thousand to a small fraction of an Hz. They have been most effective in the study of black-hole mergers. We suggest that high-frequency relic gravitational wave (HFRGW) detectors be developed, especially the Li-Baker HFRGW detector, in the gigahertz and higher frequency range. We believe collecting cosmological, primordial observational data especially generated during the first few seconds after the beginning of our Universe is extremely important. One motivation for this paper is, therefore, that we are confident that observation of relic gravitational waves will provide vital information about the birth of our Universe and its early dynamical evolution. Other astrophysical applications of HFRGW detectors involve the entropy growth of the early Universe, an ability to study alternatives to inflation and to provide clues about the symmetries underlying new physics at the highest energies. A working hypothesis or theory, based upon the rollout of our Universe from infinitesimal Planck Length and Planck Time is presented. This theory involves the rapid motion of time and matter during that early time having frequencies on the order of trillions of cycles per second or more. Several alternative HFRGW detectors are described and the proposed Li-Baker HFRGW detector, which is theoretically sensitive to GW amplitudes, A, as small as 10-32, is discussed in detail. Such sensitivity may provide a means for verifying or falsifying the rollout of our Universe working hypothesis. Essentially a combination of theory and experimentation is presented. It is recommended that plans and detailed specifications for the Li-Baker HFRGW detector be prepared in order to expedite its fabrication. 展开更多
关键词 HIGH-frequency GRAVITATIONAL Waves DARK Energy DARK Matter Variation of Speed of Time Beyond the standard Model of COSMOLOGY Early UNIVERSE
下载PDF
Micro-piezoelectric pulse diagnoser and frequency domain analysis of human pulse signals
17
作者 Hung Chang Jiaxu Chen Yueyun Liu 《Journal of Traditional Chinese Medical Sciences》 2018年第1期35-42,共8页
Background:The theory of pulse diagnosis is to assess the physiological condition of the human body using radial pulse.However,pulses can vary markedly from person to person.Further,pulse diagnosis is difficult to lea... Background:The theory of pulse diagnosis is to assess the physiological condition of the human body using radial pulse.However,pulses can vary markedly from person to person.Further,pulse diagnosis is difficult to learn and requires one-on-one teaching.Methods:To address this problem,we built a home-made pulse diagnoser and measured human pulses for studying the standardization of pulse diagnosis.Our pulse diagnoser was composed of a piezoelectric transducer,differential amplifier,data acquisition instrument,and a Matlab analysis program.The measured pulses were converted into electronic signals by a piezoelectric transducer and saved on a computer.The digitalized data were then refined and analyzed by fast Fourier transform for frequency analysis.Simulations were performed to assess the factors that affected the pulse,including phase shifts of reflected pulse waves (generate sub-peaks in pulses),inconsistent heart rates (deform pulse waves),the vessel stiffness (alter harmonic frequencies of the pulses),and the wave amplitudes (determined by the pulse strength).Results:By comparing a published report and our simulation findings,we characterized the pulse types and the effects of various factors,and then applied the findings to study actual pulses in patients.Three types of pulses were determined from the frequency spectrumchoppy pulse (Se mai) without apparent harmonic peaks,the harmonic frequencies of wiry pulse (Xian mai) that are non-integer multiples of the fundamental frequency,and surging pulse (Hong mai) that exhibit strong amplitudes in the spectrum of frequency.A normal pulse and a slippery pulse were differentiated by a phase shift,but not by assessing the frequency spectrum.Conclusion:These findings confirm that frequency domain analysis can avoid ambiguity arising in assessing the three types of pulses in the time domain.Further studies of other pulses in the frequency domain are required to develop a precise electronic pulse diagnoser. 展开更多
关键词 PULSE DIAGNOSIS Electronic PULSE diagnoser standardIZATION of PULSE DIAGNOSIS in traditional Chinese MEDICINE frequency spectrum Fast FOURIER TRANSFORM
下载PDF
A tunable passive mixer for SAW-less front-end with reconfigurable voltage conversion gain and intermediate frequency bandwidth 被引量:1
18
作者 陶健 fan xiangning zhao yuan 《High Technology Letters》 EI CAS 2018年第1期10-18,共9页
An adjustable mixer for surface acoustic wave( SAW)-less radio frequency( RF) front-end is presented in this paper. Through changing the bias voltage,the presented mixer with reconfigurable voltage conversion gain( VC... An adjustable mixer for surface acoustic wave( SAW)-less radio frequency( RF) front-end is presented in this paper. Through changing the bias voltage,the presented mixer with reconfigurable voltage conversion gain( VCG) is suitable for multi-mode multi-standard( MMMS) applications. An equivalent local oscillator( LO) frequency-tunable high-Q band-pass filter( BPF) at low noise amplifier( LNA) output is used to reject the out-of-band interference signals. Base-band( BB) capacitor of the mixer is variable to obtain 15 kinds of intermediate frequency( IF) bandwidth( BW). The proposed passive mixer with LNA is implemented in TSMC 0. 18μm RF CMOS process and operates from 0. 5 to 2. 5 GHz with measured maximum out-of-band rejection larger than 40 d B. The measured VCG of the front-end can be changed from 5 to 17 d B; the maximum input intercept point( IIP3) is0 d Bm and the minimum noise figure( NF) is 3. 7 d B. The chip occupies an area of 0. 44 mm^2 including pads. 展开更多
关键词 RECONFIGURABLE radio frequency (RF) FRONT-END multi-mode multi-standard( MMMS) high-Q BAND-PASS filter ( BPF) cross-coupled common gate low noise amplifier ( CC-CGLNA) CMOS
下载PDF
AES Encrypted FSK Generation at X-Band Frequency using a Single Reflex Klystron
19
作者 Mohuya Chakraborty Amiya Kumar Mallick 《China Communications》 SCIE CSCD 2010年第3期1-9,共9页
This paper describes a high security data transmission system over X-band microwave frequency. The paper has two parts. The first part deals with encryption of binary data by Advanced Encryption Standard (AES) using V... This paper describes a high security data transmission system over X-band microwave frequency. The paper has two parts. The first part deals with encryption of binary data by Advanced Encryption Standard (AES) using VHDL modeling of Field Programmable Gate Array (FPGA). The second part deals with a novel idea of transmitting the encrypted data by using a single klystron. This requires the simultaneous generation of a pair of two independent RF frequencies from a reflex klystron working for X-band frequency range. In this scheme, the klystron is suitably biased on the repeller terminal and superimposed on a train of AES encrypted binary data so as to create two RF frequencies one corresponding to negative peaks and the other one to the positive peaks of the data resulting in an Frequency Shift Keying (FSK) signal. The results have been verified experimentally. 展开更多
关键词 通信技术 波段 微波 频率 数据传输系统
下载PDF
国产磁选态铯束频率标准环境特性研究
20
作者 郑宁 张亮 +5 位作者 郝莉娜 王骥 杨军 刘志栋 陈江 高望远 《时间频率学报》 CSCD 2024年第1期1-7,共7页
铯原子频率标准具有长期稳定性好、可靠性高的优点,在导航定位、守时授时、通信电力、时频计量等领域有着广泛的应用。近年来由于军事领域对高精度时间频率源的需求,铯原子频标的使用环境从实验室走向了战车、舰船等机动平台。本文针对... 铯原子频率标准具有长期稳定性好、可靠性高的优点,在导航定位、守时授时、通信电力、时频计量等领域有着广泛的应用。近年来由于军事领域对高精度时间频率源的需求,铯原子频标的使用环境从实验室走向了战车、舰船等机动平台。本文针对铯原子频标在战车、舰船、高原等复杂环境下的环境适应性,研究环境因素对整机指标的影响机理。通过仿真与试验对整钟设计进行优化,以提高整机在力学、热、磁场、低气压等复杂环境下的适应性。经过优化设计后的国产铯束频率标准样机通过了相关环境试验项目的考核,各项指标均满足要求。研究结果表明,铯原子钟电性能样机的稳定度优于8.73×10^(-15)/5 d,磁敏感度3.15×10^(-14)/Gauss,工作温度特性-8.18×10^(-14),这项工作为国产化铯钟的进一步应用提供了基础。 展开更多
关键词 国产铯束频率标准 环境适应性 振动 低气压 稳定度
下载PDF
上一页 1 2 50 下一页 到第
使用帮助 返回顶部