Unified power quality conditioner(UPQC)with energy storage is commonly based on conventional capacity configuration strategy with power angle control.It has problems such as phase jumping before and after compensation...Unified power quality conditioner(UPQC)with energy storage is commonly based on conventional capacity configuration strategy with power angle control.It has problems such as phase jumping before and after compensation.DC-link cannot continuously emit active power externally.Therefore,this paper presents the compensation strategy of full load voltage magnitude and phase in capacity configuration of UPQC.The topology of UPQC is integrated a series active power filter(SAPF),a shunt active power filter(PAPF)and a photovoltaic-battery energy storage system(PV-BESS).The principle of full load voltage compensation is analyzed based on the PV-BESS-UPQC topology.Themagnitude constant of load voltage ismaintained by controlling the appropriate shunt compensation current.Then the UPQC capacity configuration is carried out using the full load voltage compensation strategy.The compensation capacity of UPQC series and shunt units are reduced.Finally,the simulation results show that the proposed compensation strategy reduces the capacity configuration by 5.11 kVA(36.4%)compared to the conventional compensation strategy.The proposed strategy can achieve full compensation of the load voltage,which can effectively reduce the capacity allocation and improve the economy of UPQC.It also has the PV-BESS units’ability of providing active power and can stabilize the DC-link voltage.展开更多
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren...The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.展开更多
基金Supported by Open Project of Jiangsu Key Laboratory of Power Transmission&Distribution Equipment Technology(2021JSSPD12)Supported by Talent Projects of Jiangsu University of Technology(KYY20018)Supported by Graduate Practice Innovation Program of Jiangsu University of Technology(XSJCX21_32).
文摘Unified power quality conditioner(UPQC)with energy storage is commonly based on conventional capacity configuration strategy with power angle control.It has problems such as phase jumping before and after compensation.DC-link cannot continuously emit active power externally.Therefore,this paper presents the compensation strategy of full load voltage magnitude and phase in capacity configuration of UPQC.The topology of UPQC is integrated a series active power filter(SAPF),a shunt active power filter(PAPF)and a photovoltaic-battery energy storage system(PV-BESS).The principle of full load voltage compensation is analyzed based on the PV-BESS-UPQC topology.Themagnitude constant of load voltage ismaintained by controlling the appropriate shunt compensation current.Then the UPQC capacity configuration is carried out using the full load voltage compensation strategy.The compensation capacity of UPQC series and shunt units are reduced.Finally,the simulation results show that the proposed compensation strategy reduces the capacity configuration by 5.11 kVA(36.4%)compared to the conventional compensation strategy.The proposed strategy can achieve full compensation of the load voltage,which can effectively reduce the capacity allocation and improve the economy of UPQC.It also has the PV-BESS units’ability of providing active power and can stabilize the DC-link voltage.
基金The financial support from the National Natural Science Foundation of China (No. 51107143)
文摘The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.