In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpat...In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction.展开更多
Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imagi...Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imaging with high spatial resolution.However,the traditional NIR-IIfluorescence confocal microscope with separate excitation focus and detection pinhole makes it possess low confocal e±ciency,as well as di±cultly to adjust.Two types of upgraded NIR-IIfluorescence confocal microscopes,sharing the same pinhole by excitation and emission focus,leading to higher confocal e±ciency,are built in this work.One type is-ber-pinhole-based confocal microscope applicable to CW laser excitation.It is constructed forfluorescence intensity imaging with large depth,high stabilization and low cost,which could replace multiphotonfluorescence microscopy in some applications(e.g.,cerebrovascular and hepatocellular imaging).The other type is air-pinhole-based confocal microscope applicable to femtosecond(fs)laser excitation.It can be employed not only for NIR-IIfluorescence intensity imaging,but also for multi-channelfluorescence lifetime imaging to recognize different structures with similarfluorescence spectrum.Moreover,it can be facilely combined with multiphotonfluorescence microscopy.A single fs pulsed laser is utilized to achieve up-conversion(visible multiphotonfluorescence)and down-conversion(NIR-II one-photonfluorescence)excitation simultaneously,extending imaging spectral channels,and thus facilitates multi-structure and multi-functional observation.展开更多
Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation....Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure.展开更多
BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a n...BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.展开更多
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical...Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.展开更多
In order to realize the detection and analysis of microalgae in sediment samples with complex scenes, the project takes advantage of the character of microalgae that they can auto-fluoresce when exposed to the illumin...In order to realize the detection and analysis of microalgae in sediment samples with complex scenes, the project takes advantage of the character of microalgae that they can auto-fluoresce when exposed to the illumination of certain exciation waves. The project takes grey-scale and fluorescent pictures of microalgae in the same field of view and uses the image processing technique to deal with the images, such as threshold segmentation, contour and texture analysis and pattern recognition. The results show that the fluorescent image can effectively elimate the yawp in the complex background and make the consequent image processing more effective and easy. Then the project comes to the conclusion that fluorescence-assisted image processing can realize the detection and analysis of microalgae in sediment samples containing complex scenes.展开更多
Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affec...Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies.展开更多
The automatic and accurate identification of apoptosis facilitates large-scale cell analysis.Most identification approaches using nucleus fluorescence imaging are based on specific morphological parameters.However,the...The automatic and accurate identification of apoptosis facilitates large-scale cell analysis.Most identification approaches using nucleus fluorescence imaging are based on specific morphological parameters.However,these parameters cannot completely describe nuclear morphology,thus limiting the identification accuracy of models.This paper proposes a new feature extraction method to improve the performance of the model for apoptosis identification.The proposed method uses a histogram of oriented gradient(HOG)of high-frequency wavelet coefficients to extract internal and edge texture information.The HOG vectors are classified using support vector machine.The experimental results demonstrate that the proposed feature extraction method well performs apoptosis identification,attaining 95:7% accuracy with low cost in terms of time.We confirmed that our method has potential applications to cell biology research.展开更多
Objective and Impact Statement:We developed a generalized computational approach to design uniform,high-intensity excitation light for low-cost,quantitative fluorescence imaging of in vitro,ex vivo,and in vivo samples...Objective and Impact Statement:We developed a generalized computational approach to design uniform,high-intensity excitation light for low-cost,quantitative fluorescence imaging of in vitro,ex vivo,and in vivo samples with a single device.Introduction:Fluorescence imaging is a ubiquitous tool for biomedical applications.Researchers extensively modify existing systems for tissue imaging,increasing the time and effort needed for translational research and thick tissue imaging.These modifications are applicationspecific,requiring new designs to scale across sample types.Methods:We implemented a computational model to simulate light propagation from multiple sources.Using a global optimization algorithm and a custom cost function,we determined the spatial positioning of optical fibers to generate 2 illumination profiles.These results were implemented to image core needle biopsies,preclinical mammary tumors,or tumor-derived organoids.Samples were stained with molecular probes and imaged with uniform and nonuniform illumination.Results:Simulation results were faithfully translated to benchtop systems.We demonstrated that uniform illumination increased the reliability of intraimage analysis compared to nonuniform illumination and was concordant with traditional histological findings.The computational approach was used to optimize the illumination geometry for the purposes of imaging 3 different fluorophores through a mammary window chamber model.Illumination specifically designed for intravital tumor imaging generated higher image contrast compared to the case in which illumination originally optimized for biopsy images was used.Conclusion:We demonstrate the significance of using a computationally designed illumination for in vitro,ex vivo,and in vivo fluorescence imaging.Applicationspecific illumination increased the reliability of intraimage analysis and enhanced the local contrast of biological features.This approach is generalizable across light sources,biological applications,and detectors.展开更多
The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized li...The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications.展开更多
It is critical to establish a direct and precise method with a high sensitivity and selectivity in analytical chemistry. In this research, making use of a well known phenomenon of capillary flow, we have proposed an...It is critical to establish a direct and precise method with a high sensitivity and selectivity in analytical chemistry. In this research, making use of a well known phenomenon of capillary flow, we have proposed an image analysis method of nucleic acids at the price of a small amount of sample. When a droplet of the supramolecular complex solution, formed by neutral red and nucleic acids(NA) under an approximate neutral condition, was placed on the hydrophobic surface of dimethyl dichlorosilane pretreated glass slides, and it was evaporated, the supramolecular complex exhibited the periphery of the droplet due to the capillary effect, and accumulated there to form a red capillary flow directed assembly ring(CFDAR). A typical CFDAR has an outer diameter of (2 r ) about 1.18 mm and a ring width(2 δ ) of about 41 μm. Depending on the experimental conditions, a variety of CFDAR can be assembled. The experimental results are in agreement with our former theoretical discussion. It was found that when a droplet volume is 0.1 μL, the fluorescence intensity of the CFDAR formed by the NR NA is in proportion to the content of calf thymus DNA in the range of 0-0.28 ng, fish sperm DNA of 0-0.24 ng and yeast RNA of 0-0.16 ng with the limit of detection(3 σ ) of 1 7, 1.4 and 0.9 pg, respectively for the three nucleic acids.展开更多
Dual-functional aggregation-induced photosensitizers(AIE-PSs)with singlet oxygen generation(SOG)ability and bright fluorescence in aggregated state have received much attention in image-guided photodynamic therapy(PDT...Dual-functional aggregation-induced photosensitizers(AIE-PSs)with singlet oxygen generation(SOG)ability and bright fluorescence in aggregated state have received much attention in image-guided photodynamic therapy(PDT).However,designing an AIE-PS with both high SOG and intense fluorescence via molecular design is still challenging.In this work,we report a new nanohybrid consisting of gold nanostar(AuNS)and AIE-PS dots with enhanced fluorescence and photosensitization for theranostic applications.The spectral overlap between the extinction of AuNS and fluorescence emission of AIE-PS dots(665 nm)is carefully selected using five different AuNSs with distinct localized surface plasmon(LSPR)peaks.Results show that all the AuNS s can enhance the 1 O2 production of AIE-PS dots,among which the AuNS with LSPR peak at 585 nm exhibited the highest 1 O2 enhancement factor of15-fold with increased fluorescence brightness.To the best of our knowledge,this is the highest enhancement factor reported for the metalenhanced singlet oxygen generation systems.The Au585@AIE-PS nanodots were applied for simultaneous fluorescence imaging and photodynamic ablation of HeLa cancer cells with strongly enhanced PDT efficiency in vitro.This study provides a better understanding of the metal-enhanced AIE-PS nanohybrid systems,opening up new avenue towards advanced image-guided PDT with greatly improved efficacy.展开更多
Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reco...Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1.展开更多
Background: Even though NIR fluorescence imaging has many advantages in SLN mapping and cancer detection, NIR fluorescence imaging shows a serious drawback that NIR cannot be detected by the naked eye without any dete...Background: Even though NIR fluorescence imaging has many advantages in SLN mapping and cancer detection, NIR fluorescence imaging shows a serious drawback that NIR cannot be detected by the naked eye without any detectors. This limitation further disturbs accurate SLN detection and adequate tumor resection resulting in the presence of cancerous cells near the boundaries of surgically removed tissues. Materials and methods: To overcome the drawback of the conventional NIR imaging method, we suggest a novel NIR imaging system which can make the NIR fluorescence image visible to the naked eye as NIR fluorescence image detected by a video camera is processed by a computer and then projected back onto the NIR fluorescence excitation position with a projector using conspicuous color light. Image processing techniques were used for projection onto the exact position of the NIR fluorescence image. Also, we implemented a phantom experiment to evaluate the performance of the developed NIR fluorescence projection system by use of the ICG. Results: The developed NIR fluorescence projection system was applied in normal mouse model to confirm the usefulness of the system in the clinical field. A BALB/c nude mouse was prepared to be applied in normal mouse model and 0.25 mg/ml stock solution of the ICG was injected through a tail vein of the mouse. From the application in normal mouse model, we could confirm that the injected ICG stayed in the liver of the mouse and verify that the projection system projected the ICG fluorescence image at the exact location of the ICG by performing laparotomy of the mouse. Conclusions: From the application in normal mouse model, we could verify that the ICG fluorescence image was precisely projected back on the site where ICG fluorescence generated. It can be demonstrated that the NIR fluorescence projection system can make it possible to visualize the invisible NIR fluorescence image and to realize that SLN mapping and cancer detection in clinical surgery.展开更多
In this paper, we describe an algorithm that performs automatic detection and tracking of astral microtubules in fluorescence confocal images. This sub-population of microtubules only exists during and immediately bef...In this paper, we describe an algorithm that performs automatic detection and tracking of astral microtubules in fluorescence confocal images. This sub-population of microtubules only exists during and immediately before mitosis and aids in the spindle orientation by connecting it to the cell cortex. Anomalies in their dynamic behaviour play a causal role in many diseases, such as development disorders and cancer. The main novelty of the proposed algorithm lies in the fact it provides a fully automated estimation of parameters related to microtubule dynamic instability (growth velocity, track length and track lifetime), and helps in understanding the effects of intermediate drug concentrations. Its performance has been objectively assessed using publicly available synthetic data and largely employed metrics. Moreover, we present experiments addressing cell cultures doped with different concentrations of taxol and nocodazole. Such drugs are known to suppress the microtubule dynamic instability, but their effects at intermediate concentrations are not completely assessed. The algorithm has been compared with other state-of-the-art approaches, tested on consistent real datasets. The results are encouraging in terms of performance, robustness and simplicity of use, and the algorithm is now routinely employed in our Department of Molecular Biotechnology.展开更多
Infrared and visible light images can be obtained simultaneously by building fluorescence imaging system,which includes fluorescence excitation,images acquisition,mechanical part,image transmission and processing sect...Infrared and visible light images can be obtained simultaneously by building fluorescence imaging system,which includes fluorescence excitation,images acquisition,mechanical part,image transmission and processing section.This system studied the 2charge-coupled device(CCD)camera(AD-080CL)of the JAI company.Fusion algorithm of visible light and near infrared images was designed for the fluorescence imaging system with wavelet transform image fusion algorithm.In order to enhance the fluorescent moiety of the fusion image,the luminance value of the green component of the color image was changed.And using microsoft foundation classes(MFC)application architecture,the supporting software system was bulit in VS2010 environment.展开更多
[Objective] This study was to determine the response of Ficus microcarpa L. foliage to polyethylene glycol (PEG) simulated water stress using chlorophyll fluo- rescence imaging technique. [Method] The responses of d...[Objective] This study was to determine the response of Ficus microcarpa L. foliage to polyethylene glycol (PEG) simulated water stress using chlorophyll fluo- rescence imaging technique. [Method] The responses of detached leaves from Ficus microcarpa, Ficus benjamina and Nerium oleander to PEG-6000 simulated water stress were detected, and the chlorophyll fluorescence imaging technique was used to detect and analyze the stress at different spots of a single leaf simultaneously. [Result] The responses of Ficus microcarpa, Ficus benjamina and Nerium oleander to dehydration showed that: ~1~) the maximal photochemical efficiency (Fv/Fm) and non- photo-chemical quenching (NPQ) values were small in the reaction center among different detected spots of leaves, and there were great differences between relative electron transport rate (ETR), photochemical quenching (qP) and quantum efficiency of PSII photochemistry ((φPSII); (2) the differences of these parameters were more ob- vious among different spots of water-stressed leaves; (3) the discrete degrees of the species with strong resitances decreased significantly. [Conclusion] This study lays the foundation for the further research on the response of plants to drought stress using chlorophyll fluorescence imaging technique.展开更多
The MINimal emission FLUXes(MINFLUX)technique in optical microscopy,widely recognized as the next innovative fluorescence microscopy method,claims a spatial resolution of 1-3 nm in both dead and living cells.To make u...The MINimal emission FLUXes(MINFLUX)technique in optical microscopy,widely recognized as the next innovative fluorescence microscopy method,claims a spatial resolution of 1-3 nm in both dead and living cells.To make use of the full resolution of the MINFLUX microscope,it is important to select appropriate fluorescence probes and labeling strategies,especially in living-cell imaging.This paper mainly focuses on recent applications and developments of fluorescence probes and the relevant labeling strategy for MINFLUX microscopy.Moreover,we discuss the deficiencies that need to be addressed in the future and a plan for the possible progression of MINFLUX to help investigators who have been involved in or are just starting in the field of super-resolution imaging microscopy with theoretical support.展开更多
In recent years, the use of fluorescence-guided surgery(FGS) to treat benign and malignant visceral, hepatobiliary and pancreatic neoplasms has significantly increased. FGS relies on the fluorescence signal emitted by...In recent years, the use of fluorescence-guided surgery(FGS) to treat benign and malignant visceral, hepatobiliary and pancreatic neoplasms has significantly increased. FGS relies on the fluorescence signal emitted by injected substances(fluorophores) after being illuminated by ad hoc laser sources to help guide the surgical procedure and provide the surgeon with real-time visualization of the fluorescent structures of interest that would be otherwise invisible. This review surveys and discusses the most common and emerging clinical applications of indocyanine green(ICG)-based fluorescence in visceral, hepatobiliary and pancreatic surgery. The analysis, findings, and discussion presented here rely on the authors' significant experience with this technique in their medical institutions, an up-to-date review of the most relevant articles published on this topic between 2014 and 2018, and lengthy discussions with key opinion leaders in the field during recent conferences and congresses. For each application, the benefits and limitations of this technique, as well as applicable future directions, are described. The imaging of fluorescence emitted by ICG is a simple, fast,relatively inexpensive, and harmless tool with numerous different applications in surgery for both neoplasms and benign pathologies of the visceral and hepatobiliary systems. The ever-increasing availability of visual systems that can utilize this tool will transform some of these applications into the standard of care in the near future. Further studies are needed to evaluate the strengths and weaknesses of each application of ICG-based fluorescence imaging in abdominal surgery.展开更多
Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determine...Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determined by immunohistochemical(IHC) staining using tissue microarrays with the H-score system and immunofluorescence(IF) staining of tumor cell lines.Imaging probes with the NIR fluorescent dye cyanine 7(Cy7) conjugated to COC183 B2 Mab were chemically engineered. OC183 B2-positive human OC cells(SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging(BLI) was performed to detect tumor location and growth. COC183 B2-Cy7 at 1.1,3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline(PBS), free Cy7 dye and mouse isotype immunoglobulin G(IgG)-Cy7(delivered at the same doses as COC183 B2-Cy7) were used as controls.Results: The expression of OC183 B2 with a high H-score was more prevalent in OC tissue than fallopian tube(FT) tissue. Among 417 OC patients, the expression of OC183 B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183 B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183 B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background(T/B)ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h postinjection(hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183 B2 positive.Conclusions: COC183 B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.展开更多
基金supported by the National Key R&D Program of China(No.2020YFA0710700)the National Natural Science Foundation of China(Nos.51873201 and 82172071)+2 种基金Key Research and Development Program of Anhui Province(No.202104b11020025)the Fundamental Research Funds for the Central Universities(No.YD2060002015)the CAS Youth Interdisciplinary Team(No.JCTD-2021-08).
文摘In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction.
基金supported by National Natural Science Foundation of China(61975172,82001874 and 61735016).
文摘Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imaging with high spatial resolution.However,the traditional NIR-IIfluorescence confocal microscope with separate excitation focus and detection pinhole makes it possess low confocal e±ciency,as well as di±cultly to adjust.Two types of upgraded NIR-IIfluorescence confocal microscopes,sharing the same pinhole by excitation and emission focus,leading to higher confocal e±ciency,are built in this work.One type is-ber-pinhole-based confocal microscope applicable to CW laser excitation.It is constructed forfluorescence intensity imaging with large depth,high stabilization and low cost,which could replace multiphotonfluorescence microscopy in some applications(e.g.,cerebrovascular and hepatocellular imaging).The other type is air-pinhole-based confocal microscope applicable to femtosecond(fs)laser excitation.It can be employed not only for NIR-IIfluorescence intensity imaging,but also for multi-channelfluorescence lifetime imaging to recognize different structures with similarfluorescence spectrum.Moreover,it can be facilely combined with multiphotonfluorescence microscopy.A single fs pulsed laser is utilized to achieve up-conversion(visible multiphotonfluorescence)and down-conversion(NIR-II one-photonfluorescence)excitation simultaneously,extending imaging spectral channels,and thus facilitates multi-structure and multi-functional observation.
文摘Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure.
文摘BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.
文摘Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.
文摘In order to realize the detection and analysis of microalgae in sediment samples with complex scenes, the project takes advantage of the character of microalgae that they can auto-fluoresce when exposed to the illumination of certain exciation waves. The project takes grey-scale and fluorescent pictures of microalgae in the same field of view and uses the image processing technique to deal with the images, such as threshold segmentation, contour and texture analysis and pattern recognition. The results show that the fluorescent image can effectively elimate the yawp in the complex background and make the consequent image processing more effective and easy. Then the project comes to the conclusion that fluorescence-assisted image processing can realize the detection and analysis of microalgae in sediment samples containing complex scenes.
基金supported by the National Natural Science Foundation of China(82072432)the China-Japan Friendship Hospital Horizontal Project/Spontaneous Research Funding(2022-HX-JC-7)+1 种基金the National High Level Hospital Clinical Research Funding(2022-NHLHCRF-PY-20)the Elite Medical Professionals project of China-Japan Friendship Hospital(ZRJY2021-GG12).
文摘Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies.
基金This work is supported by the Key Project of the National Natural Science Foundation of China(Grant Number 62135003)the Science and Technology Program of Guangzhou(Grant No.202201010704)Special Carrier Program of Qingyuan Hitech Industrial Development Zone.
文摘The automatic and accurate identification of apoptosis facilitates large-scale cell analysis.Most identification approaches using nucleus fluorescence imaging are based on specific morphological parameters.However,these parameters cannot completely describe nuclear morphology,thus limiting the identification accuracy of models.This paper proposes a new feature extraction method to improve the performance of the model for apoptosis identification.The proposed method uses a histogram of oriented gradient(HOG)of high-frequency wavelet coefficients to extract internal and edge texture information.The HOG vectors are classified using support vector machine.The experimental results demonstrate that the proposed feature extraction method well performs apoptosis identification,attaining 95:7% accuracy with low cost in terms of time.We confirmed that our method has potential applications to cell biology research.
基金This work was supported by generous funding from the National Institutes of Health grant(5R01EB028148-02)(N.R.)the Department of Defense National Defense Science and Engineering Graduate Fellowship Program(R.J.D.)the Doctoral Scholarship by Duke Global Health Institute(R.W.)。
文摘Objective and Impact Statement:We developed a generalized computational approach to design uniform,high-intensity excitation light for low-cost,quantitative fluorescence imaging of in vitro,ex vivo,and in vivo samples with a single device.Introduction:Fluorescence imaging is a ubiquitous tool for biomedical applications.Researchers extensively modify existing systems for tissue imaging,increasing the time and effort needed for translational research and thick tissue imaging.These modifications are applicationspecific,requiring new designs to scale across sample types.Methods:We implemented a computational model to simulate light propagation from multiple sources.Using a global optimization algorithm and a custom cost function,we determined the spatial positioning of optical fibers to generate 2 illumination profiles.These results were implemented to image core needle biopsies,preclinical mammary tumors,or tumor-derived organoids.Samples were stained with molecular probes and imaged with uniform and nonuniform illumination.Results:Simulation results were faithfully translated to benchtop systems.We demonstrated that uniform illumination increased the reliability of intraimage analysis compared to nonuniform illumination and was concordant with traditional histological findings.The computational approach was used to optimize the illumination geometry for the purposes of imaging 3 different fluorophores through a mammary window chamber model.Illumination specifically designed for intravital tumor imaging generated higher image contrast compared to the case in which illumination originally optimized for biopsy images was used.Conclusion:We demonstrate the significance of using a computationally designed illumination for in vitro,ex vivo,and in vivo fluorescence imaging.Applicationspecific illumination increased the reliability of intraimage analysis and enhanced the local contrast of biological features.This approach is generalizable across light sources,biological applications,and detectors.
基金supported by the Fundamental Re-search Funds for the Central Universities(HYGJXM202309).
文摘The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications.
基金Supported by the NationalNaturalScience Foundation of China( No. 2 0 175 0 1) and U niversity Key Teachers Programdirected under the Ministry of Education ofP.R.China( No. 2 0 0 0 - 6 5 )
文摘It is critical to establish a direct and precise method with a high sensitivity and selectivity in analytical chemistry. In this research, making use of a well known phenomenon of capillary flow, we have proposed an image analysis method of nucleic acids at the price of a small amount of sample. When a droplet of the supramolecular complex solution, formed by neutral red and nucleic acids(NA) under an approximate neutral condition, was placed on the hydrophobic surface of dimethyl dichlorosilane pretreated glass slides, and it was evaporated, the supramolecular complex exhibited the periphery of the droplet due to the capillary effect, and accumulated there to form a red capillary flow directed assembly ring(CFDAR). A typical CFDAR has an outer diameter of (2 r ) about 1.18 mm and a ring width(2 δ ) of about 41 μm. Depending on the experimental conditions, a variety of CFDAR can be assembled. The experimental results are in agreement with our former theoretical discussion. It was found that when a droplet volume is 0.1 μL, the fluorescence intensity of the CFDAR formed by the NR NA is in proportion to the content of calf thymus DNA in the range of 0-0.28 ng, fish sperm DNA of 0-0.24 ng and yeast RNA of 0-0.16 ng with the limit of detection(3 σ ) of 1 7, 1.4 and 0.9 pg, respectively for the three nucleic acids.
基金supported by the Institute of Materials Research and Engineering under Biomimetic and Biomedical Materials program(IMRE/00-1P1400)Newcastle University(RSA/CCEAMD5010)+1 种基金National University of Singapore(R279-000-482-133)The funding from NRF Investigatorship(R279-000-444-281)is also appreciated。
文摘Dual-functional aggregation-induced photosensitizers(AIE-PSs)with singlet oxygen generation(SOG)ability and bright fluorescence in aggregated state have received much attention in image-guided photodynamic therapy(PDT).However,designing an AIE-PS with both high SOG and intense fluorescence via molecular design is still challenging.In this work,we report a new nanohybrid consisting of gold nanostar(AuNS)and AIE-PS dots with enhanced fluorescence and photosensitization for theranostic applications.The spectral overlap between the extinction of AuNS and fluorescence emission of AIE-PS dots(665 nm)is carefully selected using five different AuNSs with distinct localized surface plasmon(LSPR)peaks.Results show that all the AuNS s can enhance the 1 O2 production of AIE-PS dots,among which the AuNS with LSPR peak at 585 nm exhibited the highest 1 O2 enhancement factor of15-fold with increased fluorescence brightness.To the best of our knowledge,this is the highest enhancement factor reported for the metalenhanced singlet oxygen generation systems.The Au585@AIE-PS nanodots were applied for simultaneous fluorescence imaging and photodynamic ablation of HeLa cancer cells with strongly enhanced PDT efficiency in vitro.This study provides a better understanding of the metal-enhanced AIE-PS nanohybrid systems,opening up new avenue towards advanced image-guided PDT with greatly improved efficacy.
基金supported by the Sichuan Science and Technology Program,China(No.2020ZDZX0004)。
文摘Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1.
文摘Background: Even though NIR fluorescence imaging has many advantages in SLN mapping and cancer detection, NIR fluorescence imaging shows a serious drawback that NIR cannot be detected by the naked eye without any detectors. This limitation further disturbs accurate SLN detection and adequate tumor resection resulting in the presence of cancerous cells near the boundaries of surgically removed tissues. Materials and methods: To overcome the drawback of the conventional NIR imaging method, we suggest a novel NIR imaging system which can make the NIR fluorescence image visible to the naked eye as NIR fluorescence image detected by a video camera is processed by a computer and then projected back onto the NIR fluorescence excitation position with a projector using conspicuous color light. Image processing techniques were used for projection onto the exact position of the NIR fluorescence image. Also, we implemented a phantom experiment to evaluate the performance of the developed NIR fluorescence projection system by use of the ICG. Results: The developed NIR fluorescence projection system was applied in normal mouse model to confirm the usefulness of the system in the clinical field. A BALB/c nude mouse was prepared to be applied in normal mouse model and 0.25 mg/ml stock solution of the ICG was injected through a tail vein of the mouse. From the application in normal mouse model, we could confirm that the injected ICG stayed in the liver of the mouse and verify that the projection system projected the ICG fluorescence image at the exact location of the ICG by performing laparotomy of the mouse. Conclusions: From the application in normal mouse model, we could verify that the ICG fluorescence image was precisely projected back on the site where ICG fluorescence generated. It can be demonstrated that the NIR fluorescence projection system can make it possible to visualize the invisible NIR fluorescence image and to realize that SLN mapping and cancer detection in clinical surgery.
文摘In this paper, we describe an algorithm that performs automatic detection and tracking of astral microtubules in fluorescence confocal images. This sub-population of microtubules only exists during and immediately before mitosis and aids in the spindle orientation by connecting it to the cell cortex. Anomalies in their dynamic behaviour play a causal role in many diseases, such as development disorders and cancer. The main novelty of the proposed algorithm lies in the fact it provides a fully automated estimation of parameters related to microtubule dynamic instability (growth velocity, track length and track lifetime), and helps in understanding the effects of intermediate drug concentrations. Its performance has been objectively assessed using publicly available synthetic data and largely employed metrics. Moreover, we present experiments addressing cell cultures doped with different concentrations of taxol and nocodazole. Such drugs are known to suppress the microtubule dynamic instability, but their effects at intermediate concentrations are not completely assessed. The algorithm has been compared with other state-of-the-art approaches, tested on consistent real datasets. The results are encouraging in terms of performance, robustness and simplicity of use, and the algorithm is now routinely employed in our Department of Molecular Biotechnology.
基金National Natural Science Foundation of China(No.61171177)National Major Scientific Equipment Development Projects of China(No.2013YQ240803)+1 种基金Natural Science Foundation for Young Scientists of Shanxi Province(No.2012021011-1)Scientific and Technological Project in Shanxi Province(No.20140321010-02)
文摘Infrared and visible light images can be obtained simultaneously by building fluorescence imaging system,which includes fluorescence excitation,images acquisition,mechanical part,image transmission and processing section.This system studied the 2charge-coupled device(CCD)camera(AD-080CL)of the JAI company.Fusion algorithm of visible light and near infrared images was designed for the fluorescence imaging system with wavelet transform image fusion algorithm.In order to enhance the fluorescent moiety of the fusion image,the luminance value of the green component of the color image was changed.And using microsoft foundation classes(MFC)application architecture,the supporting software system was bulit in VS2010 environment.
基金Supported by the Major Program for the West Action Projects of the Knowledge Innovation Program of the Chinese Academy of Sciences(KZCX2-XB2-08)the Science-Technology Foundation of Zealquest(ZQFD200705)~~
文摘[Objective] This study was to determine the response of Ficus microcarpa L. foliage to polyethylene glycol (PEG) simulated water stress using chlorophyll fluo- rescence imaging technique. [Method] The responses of detached leaves from Ficus microcarpa, Ficus benjamina and Nerium oleander to PEG-6000 simulated water stress were detected, and the chlorophyll fluorescence imaging technique was used to detect and analyze the stress at different spots of a single leaf simultaneously. [Result] The responses of Ficus microcarpa, Ficus benjamina and Nerium oleander to dehydration showed that: ~1~) the maximal photochemical efficiency (Fv/Fm) and non- photo-chemical quenching (NPQ) values were small in the reaction center among different detected spots of leaves, and there were great differences between relative electron transport rate (ETR), photochemical quenching (qP) and quantum efficiency of PSII photochemistry ((φPSII); (2) the differences of these parameters were more ob- vious among different spots of water-stressed leaves; (3) the discrete degrees of the species with strong resitances decreased significantly. [Conclusion] This study lays the foundation for the further research on the response of plants to drought stress using chlorophyll fluorescence imaging technique.
基金supported by the Science and Technology Commission of Shanghai Municipality (21DZ1100500)the Shanghai Municipal Science and Technology Major Project+1 种基金the Shanghai Frontiers Science Center Program (2021-2025 No.20)Shanghai Hong Kong,Macao,and Taiwan Cooperation Project (No.19490760900).
文摘The MINimal emission FLUXes(MINFLUX)technique in optical microscopy,widely recognized as the next innovative fluorescence microscopy method,claims a spatial resolution of 1-3 nm in both dead and living cells.To make use of the full resolution of the MINFLUX microscope,it is important to select appropriate fluorescence probes and labeling strategies,especially in living-cell imaging.This paper mainly focuses on recent applications and developments of fluorescence probes and the relevant labeling strategy for MINFLUX microscopy.Moreover,we discuss the deficiencies that need to be addressed in the future and a plan for the possible progression of MINFLUX to help investigators who have been involved in or are just starting in the field of super-resolution imaging microscopy with theoretical support.
文摘In recent years, the use of fluorescence-guided surgery(FGS) to treat benign and malignant visceral, hepatobiliary and pancreatic neoplasms has significantly increased. FGS relies on the fluorescence signal emitted by injected substances(fluorophores) after being illuminated by ad hoc laser sources to help guide the surgical procedure and provide the surgeon with real-time visualization of the fluorescent structures of interest that would be otherwise invisible. This review surveys and discusses the most common and emerging clinical applications of indocyanine green(ICG)-based fluorescence in visceral, hepatobiliary and pancreatic surgery. The analysis, findings, and discussion presented here rely on the authors' significant experience with this technique in their medical institutions, an up-to-date review of the most relevant articles published on this topic between 2014 and 2018, and lengthy discussions with key opinion leaders in the field during recent conferences and congresses. For each application, the benefits and limitations of this technique, as well as applicable future directions, are described. The imaging of fluorescence emitted by ICG is a simple, fast,relatively inexpensive, and harmless tool with numerous different applications in surgery for both neoplasms and benign pathologies of the visceral and hepatobiliary systems. The ever-increasing availability of visual systems that can utilize this tool will transform some of these applications into the standard of care in the near future. Further studies are needed to evaluate the strengths and weaknesses of each application of ICG-based fluorescence imaging in abdominal surgery.
基金supported by the National Key Research and Development Program of China (No.2016YFA0201400)National Natural Science Foundation of China (No. 81671431)
文摘Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determined by immunohistochemical(IHC) staining using tissue microarrays with the H-score system and immunofluorescence(IF) staining of tumor cell lines.Imaging probes with the NIR fluorescent dye cyanine 7(Cy7) conjugated to COC183 B2 Mab were chemically engineered. OC183 B2-positive human OC cells(SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging(BLI) was performed to detect tumor location and growth. COC183 B2-Cy7 at 1.1,3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline(PBS), free Cy7 dye and mouse isotype immunoglobulin G(IgG)-Cy7(delivered at the same doses as COC183 B2-Cy7) were used as controls.Results: The expression of OC183 B2 with a high H-score was more prevalent in OC tissue than fallopian tube(FT) tissue. Among 417 OC patients, the expression of OC183 B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183 B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183 B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background(T/B)ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h postinjection(hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183 B2 positive.Conclusions: COC183 B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.