The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the funct...The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.展开更多
Objective:To study the differences in joint function and trauma severity after arthroscopic headless compression screw fixation and conventional open reduction and internal fixation treatment of patellar transverse fr...Objective:To study the differences in joint function and trauma severity after arthroscopic headless compression screw fixation and conventional open reduction and internal fixation treatment of patellar transverse fracture.Methods: 58 patients with patellar transverse fracture who accepted operative treatment in our hospital between August 2012 and December 2015 were collected and divided into open surgery group (n=30) and arthroscopic surgery group (n=28) according to the surgical approach. Before operation and 3 months after operation, the knee joint function of two groups of patients was evaluated respectively;3 d after operation, enzyme-linked immunosorbent assay (ELISA) was used to detect serum pain mediators, stress hormones and other trauma-related indicators.Results:Differences in the knee joint function index levels were not statistically significant between two groups of patients before operation (P>0.05);3 months after operation, the maximal knee joint flexibility and maximal extension levels of arthroscopic surgery group were higher than those of open surgery group (P<0.05);3 d after operation, serum prostaglandin (PGI2), dopamine (DA), neuropeptide Y (NPY), substance P (SP), glucocorticoid (Cor), renin (R), angiotensin 1 (Ang1), angiotensin 2 (Ang2), epinephrine (E), norepinephrine (NE) and aldosterone (ALD) levels of arthroscopic surgery group were significantly lower than those of open surgery group (P<0.05).Conclusions:Arthroscopic headless compression screw fixation can optimize the knee joint function and reduce the surgical trauma in patients with patellar transverse fracture.展开更多
Objective:To observe clinical effects of pedicle screw fixation combined with cable wires and bone graft and cannulated compression screws on adult multi-segment lumbar spondylolysis.Methods:70 cases of patients with ...Objective:To observe clinical effects of pedicle screw fixation combined with cable wires and bone graft and cannulated compression screws on adult multi-segment lumbar spondylolysis.Methods:70 cases of patients with multi-segment lumbar spondylolysis were selected in our hospital.According to different surgical schemes,these patients were divided into the observation group(35 cases)and the control group(35 cases).The observation group received pedicle screw fixation combined with cable wires and bone graft and the control group received cannulated compression screw fixation.Macnab criteria were adopted to implement a therapeutic evaluation of two groups of patients to make an observation and comparison of the excellent and good rate of surgery and a series of indicators including perioperative clinical effects,intraoperative blood loss,duration of surgery,hospital length of stay(HLOS),visual analogue scale(VAS),Oswestry disability index and Japanese Orthopaedic Association(JOA)score.Results:The excellent and good rate of the observation group was 97.14%,and that of the control group was 82.86%,the difference between two groups was statistically significant(χ^(2)=6.248,p=0.012).The differences in intraoperative blood loss,duration of surgery and HLOS between two groups were statistically significant(t=-4.55,t=-4.55,t=-4.55;p<0.05).Oswestry index,VAS score and JOA score of the observation group were(2.4±0.9),(28.5±6.4)and(27.1±3.1)respectively,and these of the control group were(3.5±1.2),(37.1±7.8)and(21.3±2.7)respectively,the differences between two groups were statistically significant(t=4.338,t=5.043,t=8.347,p<0.05).Conclusions:Pedicle screw combined with immobilized implantation bone by wirerope has an excellent clinical effect on the treatment of adult multi-segment lumbar spondylolysis,and it has a series of advantages such as fast postoperative recovery,small surgical trauma and so on.In addition,this technique can also restore the stability of spinal segments and relieve pains to a greater degree.展开更多
Objective To evaluate the biomechanics of hollow-compression-screw in the osteoporotic femoral neck with composite c alcium phosphate cement (CCPC).Methods Sixteen femurs of superior segment were randomly divided into...Objective To evaluate the biomechanics of hollow-compression-screw in the osteoporotic femoral neck with composite c alcium phosphate cement (CCPC).Methods Sixteen femurs of superior segment were randomly divided into two groups:augmentation group and non-augmentation group.CCPC was used in augmentation group.Result Augmentation with CCPC would improve the initial mobile force of hollow-compression-screw,the ini tial mobile force and the maximal axial pull-out strength for augmentation group,non-augmentation group in-creased from(192.7±14.0)N and(202.8±14.0)N to(328.5±34.7)N and(347.8±31.2)N.There was significant difference of two groups(P <0.01).Conclusion CCPC can enhance hollow-compressio n-screw fixation in osteoporotic fe moral neck.展开更多
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous scr...The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures.Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-Ⅲ calcaneal fracture model by using osteotomy.The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws.Reduction of fracture was evaluated through X radiographs.Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N,representing the partial weight bearing and full weight bearing,respectively,and then the specimens were loaded to failure.Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test.No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading(P=0.06),while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading(P=0.008).The load achieved at loss of fixation of the constructs for the two groups had significant difference:anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N(P=0.008).There was no significant difference between the ultimate displacements.Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading.The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture.展开更多
Objective:To investigate the effect of vertebroplasty combined with pedicle screw fixation in the treatment of senile osteoporotic vertebral compression fractures.Methods:Eighty-one patients with senile osteoporotic v...Objective:To investigate the effect of vertebroplasty combined with pedicle screw fixation in the treatment of senile osteoporotic vertebral compression fractures.Methods:Eighty-one patients with senile osteoporotic vertebral compression fractures were enrolled in our hospital from January 2015 to January 2019.They were randomly divided into a single group(40 cases)and a combined group(41 cases).),a single group was treated with pedicle screw internal fixation,and the combined group was treated with vertebroplasty.The recovery,pain and dysfunction index of the injured vertebrae before and after operation were compared between the two groups.The serum neurological function related indexes before and after operation were compared and the incidence of postoperative adverse events were recorded.Results:There was no significant difference in the recovery of the injured vertebrae between the two groups(P>0.05).The compression ratio,spinal stenosis rate and Cobb angle of the combined group were significantly lower than the single group(P<0.05).On the 3rd postoperative day,there were no significant differences between the two groups in Visual Analogue Scale/Score(VAS)and Oswestry Dability Index(ODI)scores(P>0.05).The VAS and ODI scores of the group were significantly lower than those of the single group(P<0.05).On the 3rd day after surgery,the neuron-specific enolase(NSE)and brain derived neurotrophic factor(brain-derived neurotrophic factor)were used.The levels of BDNF,S100βand Nerve growth factor(NGF)were not significantly different(P>0.05).At 3 months after operation,the level of BDNF in the combined group was significantly higher than that in the single group.The levels of NSE,S100βand NGF were significantly lower than that of the single group.The group(P<0.05);the incidence of adverse events in the combined group was significantly lower than that in the single group(P<0.05).Conclusions:Vertebroplasty combined with pedicle screw fixation for the treatment of senile osteoporotic vertebral compression fracture can effectively improve the recovery of postoperative vertebral body structure,postoperative pain and dysfunction in Jianing patients,improve postoperative neurological function To reduce the incidence of adverse events,with clinical promotion significance.展开更多
Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly...Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.展开更多
Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in ou...Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development.展开更多
文摘The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.
文摘Objective:To study the differences in joint function and trauma severity after arthroscopic headless compression screw fixation and conventional open reduction and internal fixation treatment of patellar transverse fracture.Methods: 58 patients with patellar transverse fracture who accepted operative treatment in our hospital between August 2012 and December 2015 were collected and divided into open surgery group (n=30) and arthroscopic surgery group (n=28) according to the surgical approach. Before operation and 3 months after operation, the knee joint function of two groups of patients was evaluated respectively;3 d after operation, enzyme-linked immunosorbent assay (ELISA) was used to detect serum pain mediators, stress hormones and other trauma-related indicators.Results:Differences in the knee joint function index levels were not statistically significant between two groups of patients before operation (P>0.05);3 months after operation, the maximal knee joint flexibility and maximal extension levels of arthroscopic surgery group were higher than those of open surgery group (P<0.05);3 d after operation, serum prostaglandin (PGI2), dopamine (DA), neuropeptide Y (NPY), substance P (SP), glucocorticoid (Cor), renin (R), angiotensin 1 (Ang1), angiotensin 2 (Ang2), epinephrine (E), norepinephrine (NE) and aldosterone (ALD) levels of arthroscopic surgery group were significantly lower than those of open surgery group (P<0.05).Conclusions:Arthroscopic headless compression screw fixation can optimize the knee joint function and reduce the surgical trauma in patients with patellar transverse fracture.
文摘Objective:To observe clinical effects of pedicle screw fixation combined with cable wires and bone graft and cannulated compression screws on adult multi-segment lumbar spondylolysis.Methods:70 cases of patients with multi-segment lumbar spondylolysis were selected in our hospital.According to different surgical schemes,these patients were divided into the observation group(35 cases)and the control group(35 cases).The observation group received pedicle screw fixation combined with cable wires and bone graft and the control group received cannulated compression screw fixation.Macnab criteria were adopted to implement a therapeutic evaluation of two groups of patients to make an observation and comparison of the excellent and good rate of surgery and a series of indicators including perioperative clinical effects,intraoperative blood loss,duration of surgery,hospital length of stay(HLOS),visual analogue scale(VAS),Oswestry disability index and Japanese Orthopaedic Association(JOA)score.Results:The excellent and good rate of the observation group was 97.14%,and that of the control group was 82.86%,the difference between two groups was statistically significant(χ^(2)=6.248,p=0.012).The differences in intraoperative blood loss,duration of surgery and HLOS between two groups were statistically significant(t=-4.55,t=-4.55,t=-4.55;p<0.05).Oswestry index,VAS score and JOA score of the observation group were(2.4±0.9),(28.5±6.4)and(27.1±3.1)respectively,and these of the control group were(3.5±1.2),(37.1±7.8)and(21.3±2.7)respectively,the differences between two groups were statistically significant(t=4.338,t=5.043,t=8.347,p<0.05).Conclusions:Pedicle screw combined with immobilized implantation bone by wirerope has an excellent clinical effect on the treatment of adult multi-segment lumbar spondylolysis,and it has a series of advantages such as fast postoperative recovery,small surgical trauma and so on.In addition,this technique can also restore the stability of spinal segments and relieve pains to a greater degree.
文摘Objective To evaluate the biomechanics of hollow-compression-screw in the osteoporotic femoral neck with composite c alcium phosphate cement (CCPC).Methods Sixteen femurs of superior segment were randomly divided into two groups:augmentation group and non-augmentation group.CCPC was used in augmentation group.Result Augmentation with CCPC would improve the initial mobile force of hollow-compression-screw,the ini tial mobile force and the maximal axial pull-out strength for augmentation group,non-augmentation group in-creased from(192.7±14.0)N and(202.8±14.0)N to(328.5±34.7)N and(347.8±31.2)N.There was significant difference of two groups(P <0.01).Conclusion CCPC can enhance hollow-compressio n-screw fixation in osteoporotic fe moral neck.
文摘The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures.Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-Ⅲ calcaneal fracture model by using osteotomy.The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws.Reduction of fracture was evaluated through X radiographs.Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N,representing the partial weight bearing and full weight bearing,respectively,and then the specimens were loaded to failure.Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test.No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading(P=0.06),while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading(P=0.008).The load achieved at loss of fixation of the constructs for the two groups had significant difference:anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N(P=0.008).There was no significant difference between the ultimate displacements.Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading.The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture.
基金Qinhuangdao science and technology research and development program(No.201703A079).
文摘Objective:To investigate the effect of vertebroplasty combined with pedicle screw fixation in the treatment of senile osteoporotic vertebral compression fractures.Methods:Eighty-one patients with senile osteoporotic vertebral compression fractures were enrolled in our hospital from January 2015 to January 2019.They were randomly divided into a single group(40 cases)and a combined group(41 cases).),a single group was treated with pedicle screw internal fixation,and the combined group was treated with vertebroplasty.The recovery,pain and dysfunction index of the injured vertebrae before and after operation were compared between the two groups.The serum neurological function related indexes before and after operation were compared and the incidence of postoperative adverse events were recorded.Results:There was no significant difference in the recovery of the injured vertebrae between the two groups(P>0.05).The compression ratio,spinal stenosis rate and Cobb angle of the combined group were significantly lower than the single group(P<0.05).On the 3rd postoperative day,there were no significant differences between the two groups in Visual Analogue Scale/Score(VAS)and Oswestry Dability Index(ODI)scores(P>0.05).The VAS and ODI scores of the group were significantly lower than those of the single group(P<0.05).On the 3rd day after surgery,the neuron-specific enolase(NSE)and brain derived neurotrophic factor(brain-derived neurotrophic factor)were used.The levels of BDNF,S100βand Nerve growth factor(NGF)were not significantly different(P>0.05).At 3 months after operation,the level of BDNF in the combined group was significantly higher than that in the single group.The levels of NSE,S100βand NGF were significantly lower than that of the single group.The group(P<0.05);the incidence of adverse events in the combined group was significantly lower than that in the single group(P<0.05).Conclusions:Vertebroplasty combined with pedicle screw fixation for the treatment of senile osteoporotic vertebral compression fracture can effectively improve the recovery of postoperative vertebral body structure,postoperative pain and dysfunction in Jianing patients,improve postoperative neurological function To reduce the incidence of adverse events,with clinical promotion significance.
文摘Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.
文摘Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development.