[Objectives]To establish a gas chromatography-triple quadrupole mass spectrometry(GC-MS/MS)method based on multiple reaction monitoring(MRM)mode for the analysis of the major components in Cang-ai volatile oil(CAVO).[...[Objectives]To establish a gas chromatography-triple quadrupole mass spectrometry(GC-MS/MS)method based on multiple reaction monitoring(MRM)mode for the analysis of the major components in Cang-ai volatile oil(CAVO).[Methods]An ultrasensitive gas chromatography-tandem mass spectrometry(GC-MS/MS)method was developed and validated for the determination of three highly abundant components in rat plasma samples.Paeonol was used as an internal standard.A multiple reaction monitoring(MRM)model was employed for the quantification of the three major components of CAVO.[Results]The method demonstrated linearity over the range of 0.25 to 50μg/mL with a correlation coefficient(R 2)greater than 0.9998.The lower limit of quantification was 0.25μg/mL.Intra-day and inter-day accuracy and precision were within 15%.Extraction recovery and matrix effect values ranged from 90.1%to 110.6%and 0.1%to 2.1%,respectively.[Conclusions]This method was successfully applied to the simultaneous determination of the three components in high-level CAVO plasma samples,providing a basis for subsequent studies of CAVO.展开更多
基金the National Natural Science Foundation of China(NSFC)(82060823)Yunnan Science and Technology Talent and Platform Program(202105AG070012).
文摘[Objectives]To establish a gas chromatography-triple quadrupole mass spectrometry(GC-MS/MS)method based on multiple reaction monitoring(MRM)mode for the analysis of the major components in Cang-ai volatile oil(CAVO).[Methods]An ultrasensitive gas chromatography-tandem mass spectrometry(GC-MS/MS)method was developed and validated for the determination of three highly abundant components in rat plasma samples.Paeonol was used as an internal standard.A multiple reaction monitoring(MRM)model was employed for the quantification of the three major components of CAVO.[Results]The method demonstrated linearity over the range of 0.25 to 50μg/mL with a correlation coefficient(R 2)greater than 0.9998.The lower limit of quantification was 0.25μg/mL.Intra-day and inter-day accuracy and precision were within 15%.Extraction recovery and matrix effect values ranged from 90.1%to 110.6%and 0.1%to 2.1%,respectively.[Conclusions]This method was successfully applied to the simultaneous determination of the three components in high-level CAVO plasma samples,providing a basis for subsequent studies of CAVO.