期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Application of UHPLCMS/ MS method in determining the content of multiingredient in hospital preparations
1
作者 林志燕 杨荣富 +2 位作者 唐跃年 田怀平 张健 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2014年第4期233-240,共8页
In the present study, we established an ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to simultaneously determine 11 compounds in two hospital preparations (Shegan mixture ... In the present study, we established an ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to simultaneously determine 11 compounds in two hospital preparations (Shegan mixture and Gandi capsules), including ephedrine, caffeic acid, ferulic acid, rutin, scutellarin, belamcandin, baicalin, baicalein, astragaloside IV, irisflorentin and wogonin. The chromatographic separation was conducted on ZORBAX SB-C18 (2.1 mm×50 mm, 1.8 μm). Eleven analytes and IS were detected using ESI and MRM combined with positive and negative scanning switch. Caffeic acid, ferulic acid, scutellarin and belamcandin were detected using negative ion mode detection, whereas ephedrine, rutin, baicalin, baicalein, astragaloside IV, irisflorentin and wogonin were detected using positive ion mode detection. The quantification limits of ephedrine, caffeic acid, scutellarin, belamcandin, baicalin, baicalein, irisfiorentin and wogonin were 4.90×10^-3 ng/mL, 7.80 ng/mL, 6.8 ng/mL, 5.3×10^-2 ng/mL, 4.20×10^-3 ng/mL, 4.6×10^-2 ng/mL, 1.44×10^-4 ng/mL, 4.85 ng/mL, 0.23 ng/mL, 3.18× 10^-4 ng/mL and 2.95× 10^-4 ng/mL, respectively. The detection limits of these components were 2.90× 10^-4 ng/mL, 0.77 ng/mL, 2.0 ng/mL, 0.016 ng/mL, 1.3×10^-3 ng/mL, 3.33×10^-4 ng/mL, 4.32×10^-5 ng/mL, 1.46 ng/mL, 0.07 ng/mL, 9.5×10^-5 ng/mL and 8.84× 10^-5 ng/mL, respectively. All calibration curves showed good linearity (R^2〉0.99) within the test range. The RSD values of intra-day and inter-day precision were less than 5%, and the average recovery rates of the 11 components ranged fi'om 80% to 120%. In conclusion, our newly developed method was simple, rapid, sensitive and accurate. It could be used to determine ephedrine, caffeic acid, ferulic acid, rutin, scutellarin, belamcandin, baicalin, baicalein, astragaloside IV, irisflorentin and wogonin in Shegan mixture and Gandi capsules, which was helpful for the quality control of drugs. 展开更多
关键词 Shegan mixture gandi capsules Ultra-high pressure liquid chromatography-tandem mass spectrometry Determination of multi-ingredient Quality control of Chinese patent drug
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部