A simulation study of the parallax effect of gaseous detectors using the Garfield program is reported. A method that mainly uses non-uniform cathode potentials to reduce the parallax error of planar type gas detectors...A simulation study of the parallax effect of gaseous detectors using the Garfield program is reported. A method that mainly uses non-uniform cathode potentials to reduce the parallax error of planar type gas detectors is described. By applying it to MWPC and Micro-pattern gas detectors, the method reduces the parallax broadening with very good results. For a 13° incidence track, the width (FWHM) of the parallax broadening is reduced to less than 20% of the normal one after using the special cathode potentials.展开更多
For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in t...For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector.展开更多
A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on...A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mm×200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the ^55Fe X-ray test of the detector.展开更多
基金Supported by Scientific Research Fund of the Sichuan Provincial Education Department(11ZA140)Scientific Research Fund of Southwest University of Science and Technology(10zx7123)
文摘A simulation study of the parallax effect of gaseous detectors using the Garfield program is reported. A method that mainly uses non-uniform cathode potentials to reduce the parallax error of planar type gas detectors is described. By applying it to MWPC and Micro-pattern gas detectors, the method reduces the parallax broadening with very good results. For a 13° incidence track, the width (FWHM) of the parallax broadening is reduced to less than 20% of the normal one after using the special cathode potentials.
基金Supported by Scientific Research Fund of Sichuan Provincial Education Department(11ZA140)
文摘For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector.
文摘A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mm×200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the ^55Fe X-ray test of the detector.