期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Simulation study of the parallax ef f ect of gaseous detectors 被引量:1
1
作者 王小胡 吴军龙 李江波 《Chinese Physics C》 SCIE CAS CSCD 2012年第11期1106-1110,共5页
A simulation study of the parallax effect of gaseous detectors using the Garfield program is reported. A method that mainly uses non-uniform cathode potentials to reduce the parallax error of planar type gas detectors... A simulation study of the parallax effect of gaseous detectors using the Garfield program is reported. A method that mainly uses non-uniform cathode potentials to reduce the parallax error of planar type gas detectors is described. By applying it to MWPC and Micro-pattern gas detectors, the method reduces the parallax broadening with very good results. For a 13° incidence track, the width (FWHM) of the parallax broadening is reduced to less than 20% of the normal one after using the special cathode potentials. 展开更多
关键词 garfield simulation parallax error gaseous detector
原文传递
Influence of working gas properties on MWPC anode wire modulation effect 被引量:2
2
作者 王小胡 陈孝强 《Chinese Physics C》 SCIE CAS CSCD 2015年第10期82-86,共5页
For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in t... For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector. 展开更多
关键词 garfield simulation anode wire modulation working gas MWPC
原文传递
Design and experimental study of a two-dimensional position sensitive X-ray detector
3
作者 王小胡 朱启明 +6 位作者 陈元柏 陈昌 刘荣光 王岚 金艳 马骁妍 江山 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第11期903-907,共5页
A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on... A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mm×200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the ^55Fe X-ray test of the detector. 展开更多
关键词 garfield simulation X-ray detector MWPC
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部