Analysis of the Molecules Structure and Vertical Electron Affinity of Organic Gas Impact on Electric Strength 被引量:13
1
作者 焦俊韬 肖登明 +1 位作者 赵小令 邓云坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期554-559,共6页
It is necessary to find an efficient selection method to pre-analyze the gas electric strength from the perspective of molecule structure and the properties for finding the alternative gases to sulphur hexafluoride (... It is necessary to find an efficient selection method to pre-analyze the gas electric strength from the perspective of molecule structure and the properties for finding the alternative gases to sulphur hexafluoride (SF6). As the properties of gas are determined by the gas molecule structure, the research on the relationship between the gas molecule structure and the electric strength can contribute to the gas pre-screening and new gas development. In this paper, we calculated the vertical electron affinity, molecule orbits distribution and orbits energy of gas molecules by the means of density functional theory (DFT) for the typical structures of organic gases and compared their electric strengths. By this method, we find part of the key properties of the molecule which are related to the electric strength, including the vertical electron affinity, the lowest unoccupied molecule orbit (LUMO) energy, molecule orbits distribution and negativeion system energy. We also listed some molecule groups such as unsaturated carbons double bonds (C=C) and carbonitrile bonds (C=N) which have high electric strength theoretically by this method. 展开更多
关键词 gas insulation electric strength SF6 substitutes molecule structure
下载PDF
THE STUDY ON MEASURING TECHNIQUE OF PARTIAL DISCHARGE IN GAS INSULATED SWITCHGEAR USING ULTRA HIGH FREQUENCY METHOD WITH EXTERNAL SENSORS 被引量:1
2
作者 李忠 冯允平 《Journal of Pharmaceutical Analysis》 SCIE CAS 2005年第2期7-10,15,共5页
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ... Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique. 展开更多
关键词 gas insulated switchgear partial discharge ultra high frequency finite-difference time-domain (FDTD) method MEASUREMENT external sensor
下载PDF
Arcing Model of a Disconnector and its Effect on VFTO 被引量:6
3
作者 林莘 王娜 徐建源 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第7期644-647,共4页
In the computational process of very fast transient over-voltage (VFTO), it is essen-tial to find an accurate model for a gas insulated substation. The arcing model of the disconnector is particularly important. The... In the computational process of very fast transient over-voltage (VFTO), it is essen-tial to find an accurate model for a gas insulated substation. The arcing model of the disconnector is particularly important. The general arcing model is not able to give a good description of the arc development process. In this paper, based on the physical process of arcing and existing arc models (the exponential time-varying resistance model and the segmental arcing models), a dy- namic arcing model is proposed, which is divided into two stages before and after the zero crossing. The dynamic arcing model combines hyperbola time-varying resistance and the Mayr model to describe the dynamic process of arcing. The present paper creates an arc model blockset upon the Matlab/Simulink software platform. Moreover for a specific 1100 kV station, VFTO is simulated in detail based on different arcing models. It is demonstrated that the dynamic arcing model can describe the physical arc process precisely and is useful for improving the accuracy of VFTO simulations. 展开更多
关键词 disconnector switching UHV dynamic arcing model gas insulated substa-tion VFTO
下载PDF
GIS用超高频传感器的校准:不同校准方法的比较及一种采用锥形天线的校准系统测试(英文) 被引量:2
4
作者 David Gautschi Pierre Bertholet 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2643-2648,共6页
Different methods of calibrating ultra high frequency(UHF) sensors for gas-insulated substations(GIS) were investigated in the past.The first approach was to use strip lines,triplates and TEM calibration cells.These c... Different methods of calibrating ultra high frequency(UHF) sensors for gas-insulated substations(GIS) were investigated in the past.The first approach was to use strip lines,triplates and TEM calibration cells.These cells had already been in use for years for example to test the electromagnetic compatibility of electronic devices.The smaller the size of the cell,the higher its bandwidth-but the cell should be large enough to not disturb the electric field with the installed sensor under test.To overcome this problem,a calibration procedure using a gigahertz transverse electromagnetic (GTEM) test cell and a pulsed signal source were introduced in 1997.Although this procedure has many advantages and is easy to understand,measurements show several shortcomings of this calibration method.To overcome the disadvantages of the known systems,a calibration cell using a monopole cone antenna and a metallic ground plane were developed and tested.The UHF sensor was placed in a region with minimum distortion of the electric field due to its installation.Experience shows that the new method for calibrating UHF sensors is necessary in order to overcome the limits in the calibration of large sensors and to suppress the propagation of higher order modes and reflections.Due to its surprisingly simple structure,its low price and low overall measurement uncertainty,it is the preferred method for calibrating UHF sensors for GIS applications. 展开更多
关键词 ultra high frequency(UHF) sensors partial discharge detection partial discharge monitoring gas insulated substations(GIS) calibration of sensors calibration cells cone calibration system
下载PDF
单壁碳纳米管气体传感器在GIS局部放电检测中的应用(英文) 被引量:2
5
作者 魏宁 丁卫东 +2 位作者 朱宜东 苏春强 末广纯也 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2700-2706,共7页
This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by ... This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by partial discharge(PD) in GIS tank.The results showed a superior sensitivity,favorable reliability and good reproducibility. For further clarifying the relativity between sensor response and partial discharge activity,the discharge in GIS tank was monitored simultaneously through conventional pulse current method and a SWCNTs gas sensor,and the measurement results were put together for comparative analysis in this paper.The sensor response showed a great dependence on partial discharge characteristics.The sensor response increased nearly linearly with limits when the energy of discharge was persistently accumulated.Partial discharge power had a great influence on the response rate and the time delay.With the increase of partial discharge power,the response rate augmented almost in proportion while the time delay gradually becomes shorter with limits.The results were quite favorable to assess the partial discharge intensity and duration to some extent.Compared with pulse current method,the sensor was predominant to detect partial discharge exposed to constantly high levels of noise.It was capable of detecting partial discharge which was too weak to be detected with pulse current method.However,the sensor response didn't show much dependency on the apparent discharge of partial discharge. 展开更多
关键词 single-walled carbon nanotubes(SWCNTs) gas sensors partial discharge(PD) detection gas insulated switchgear(GIS) tank SF6 decomposition gas PD parameters
下载PDF
佛山地区500kV变电站设备运行缺陷分析 被引量:5
6
作者 郁景礼 高博 《广东电力》 2009年第2期68-72,共5页
对广东佛山地区500kV变电站运行设备从缺陷类别、发现方法、设备种类、出现原因、电压等级等方面进行了统计分析和总结,并提出了针对性较强的消缺和预防措施,对500kV变电站的运行管理、维护、建设有一定的指导意义。
关键词 500 KV变电站 封闭式组合电器(gas—insulated switchgear GIS) 缺陷 措施
下载PDF
浅论六氟化硫组合开关安装的管理
7
作者 谢飞虎 《中国水能及电气化》 2007年第3期43-45,共3页
随着国民经济的发展需要,高压配电SF6的装置广泛应用于水电站、城区变电站。做好SF6的安装、维护,能保证电力系统的安全运行。
关键词 SF6气体 (gas—insulated Switchgear)GIS全封闭组合电器 绝缘 电阻 管理
下载PDF
Discharge Characteristics of Long SF6 Gas Gap with and Without Insulator in GIS Under VFTO and LI 被引量:17
8
作者 Tao Wen Qiaogen Zhang +6 位作者 Jingtan Ma Can Guo Haoyang You Yifan Qin Yu Yin Weidong Shi Weijiang Chen 《CSEE Journal of Power and Energy Systems》 SCIE 2015年第3期16-22,共7页
Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient over... Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient overvoltage(VFTO)increases caused by a rise in voltage levels can lead to GIS insulation failures.In this paper,a generating system of VFTO and standard lightning impulse(LI)is established.The insulation characteristics of SF6 gas with and without insulators under VFTO and standard LI are investigated.Experimental results show that the 50%breakdown voltages of the inhomogeneous electric field rod-plane gap under positive VFTO and standard LI are higher than that under negative VFTO and standard LI.The research shows that the 50%breakdown voltage under VFTO could be lower than that under standard LI at 0.5 MPa for the negative polarity.Moreover,the polarity effect of the insulator without defect is different from that with defect.Similarly,the breakdown voltage of the defective insulator under VFTO could be lower than that under standard LI by 8%.The flashover channel under VFTO is seen as more than that under standard LI.Based on the analysis of discharge images and experimental results,it is concluded that the polarity effect is related to the distortion effect of ion clusters formed by SF6 on the electric field.Additionally,the steepness and front time of impulse plays an important role in the initiation and further development of discharge on insulator surface.Finally,the research shows that different discharge characteristics between VFTO and standard LI may be caused by different wave fronts and oscillation on the tails of the impulses. 展开更多
关键词 Breakdown voltage discharge characteristic gas insulated switchgear(GIS) lightning impulse(LI) space charge very fast transient overvoltage(VFTO)
原文传递
Estimation of the Type of Low Energy Discharge in GIS Adopting Characteristic Gas 被引量:7
9
作者 CHEN Jun LI Li +5 位作者 YAO Weijian TANG Yang ZHENG Xiaoguang YU Jianhui LUO Yunbai ZHOU Wenjun 《Wuhan University Journal of Natural Sciences》 CAS 2011年第4期319-324,共6页
In order to guarantee safe operations, low energy discharge within gas insulated switchgear (GIS) should be detected as soon as possible before they develop severely and cause final breakdown failures. This paper ai... In order to guarantee safe operations, low energy discharge within gas insulated switchgear (GIS) should be detected as soon as possible before they develop severely and cause final breakdown failures. This paper aims to present a GIS discharge diagnosis technique adopting gaseous decompositions. To reach this aim, needle-plate electrode and the sphere-plate electrode with metallic particles on the plate are designed to simulate two kinds of low energy discharge, namely, corona discharge and spark discharge, respectively. After sampling and analyzing the gases, different yields of gaseous by-products under different types of low energy discharge are obtained. Based on the decomposition mechanisms reported by previous researches and the experiment results, it can be concluded that S2OF10, SO2F2 , and SO2 can be used as the characteristic gas to identify low energy discharge; the increment of S2OF10 can indicate the occurrence of low energy discharges while the volume ratio between SO2F2 and SO2 can define the type of low energy discharge. 展开更多
关键词 gas insulated switchgear (GIS) SF6 decomposition low energy discharge DIAGNOSIS
原文传递
Review of Charge Accumulation on Spacers of Gas Insulated Equipment at DC Stress 被引量:4
10
作者 Hongyang Zhou Guoming Ma +4 位作者 Cong Wang Jue Wang Guixin Zhang Youping Tu Chengrong Li 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第3期496-517,共22页
Charge accumulation on the spacer surface in gas insulated equipment is very severe in the DC field,leading to easy flashover,which restricts the application of DC GIS/GIL.Therefore,knowledge about the charge accumula... Charge accumulation on the spacer surface in gas insulated equipment is very severe in the DC field,leading to easy flashover,which restricts the application of DC GIS/GIL.Therefore,knowledge about the charge accumulation characteristics of gas insulated equipment at DC stress is essential.In this paper,we reviewed the research methods and the characteristics of charge accumulation on spacers.A summary of charge measurement methods and setups are presented.And the surface charge inversion algorithms are introduced.Then the simulation model for charge accumulation in the DC field is reviewed.Subsequently,the charge accumulation mechanisms and phenomenon,the influence factor of surface charge accumulation and the influence of accumulated charge on spacer insulation characteristics are summarized.In addition,some suppression methods of surface charge accumulation are discussed.Finally,based on the understanding of charge accumulation on spacers,some suggestions on further studies are presented to aid in the design of a better spacer free from surface charges. 展开更多
关键词 Charge accumulation DC gas insulated equipment REVIEW SPACER
原文传递
Environment-friendly Insulating Gases for HVDC Gas-insulated Transmission Lines 被引量:3
11
作者 Geng Chen Youping Tu +6 位作者 Cong Wang Jue Wang Zhikang Yuan Guoming Ma Jian Wang Bo Qi Chuanyang Li 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第3期510-529,共20页
Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the ... Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the literature on sulfur hexafluoride(SF6)alternatives including the scientific understanding,control,and implementation of gas-solid systems in this type of power transmission.First,the structure-activity relationship between the molecular structure and physico-chemical properties of Environment-friendly insulating gases is presented.Then,the search and prediction of important physicochemical properties of gases are summarized.Subsequently,in view of the potential of environmental friendly insulating gases,the swarm parameters of gas discharge and breakdown properties in a quasi-uniform field,inhomogeneous field,and at the gas-solid interface,that need to be taken into account with industrialized DC GILs are discussed.The latest research progress on insulation characteristics,especially the polarity effect in DC gas-solid insulation systems,the sensitivity to the electrode surface state,and the non-uniformity of the electric field,and the influence of metal particles and their variation with air pressure,is highlighted.In addition,the heat transfer characteristics of insulating gases,related to DC GIL transmission with a large current-carrying capacity and the influence of alternative gases on the heat transfer characteristics are described.Finally,aiming at solving the contradiction of low environmental impact,high dielectric strength and low liquefaction temperatures in the selection of alternative gases,an coordinated regulation model for Environment-friendly gases in DC GILs is established.Considerations for future work on this topic are also presented. 展开更多
关键词 Environmental friendly insulating gas gas-insulated transmission line high-voltage direct-current transmis-sion sulfur hexafluoride
原文传递
A novel algorithm for frequency dependent modeling of ferrite ring and its optimum design to study VFTO behaviors within GIS
12
作者 Mehrdad MAJIDI Hamid JAVADI Moein MANBACHI 《Frontiers in Energy》 SCIE CSCD 2014年第1期90-100,共11页
One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order ... One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemen- ted on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios. 展开更多
关键词 comsol multiphysics EMTP-RV ferrite ring gas insulated substations (GIS) transient over-voltage insulation coordination
原文传递