期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
GIS用超高频传感器的校准:不同校准方法的比较及一种采用锥形天线的校准系统测试(英文) 被引量:2
1
作者 David Gautschi Pierre Bertholet 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2643-2648,共6页
Different methods of calibrating ultra high frequency(UHF) sensors for gas-insulated substations(GIS) were investigated in the past.The first approach was to use strip lines,triplates and TEM calibration cells.These c... Different methods of calibrating ultra high frequency(UHF) sensors for gas-insulated substations(GIS) were investigated in the past.The first approach was to use strip lines,triplates and TEM calibration cells.These cells had already been in use for years for example to test the electromagnetic compatibility of electronic devices.The smaller the size of the cell,the higher its bandwidth-but the cell should be large enough to not disturb the electric field with the installed sensor under test.To overcome this problem,a calibration procedure using a gigahertz transverse electromagnetic (GTEM) test cell and a pulsed signal source were introduced in 1997.Although this procedure has many advantages and is easy to understand,measurements show several shortcomings of this calibration method.To overcome the disadvantages of the known systems,a calibration cell using a monopole cone antenna and a metallic ground plane were developed and tested.The UHF sensor was placed in a region with minimum distortion of the electric field due to its installation.Experience shows that the new method for calibrating UHF sensors is necessary in order to overcome the limits in the calibration of large sensors and to suppress the propagation of higher order modes and reflections.Due to its surprisingly simple structure,its low price and low overall measurement uncertainty,it is the preferred method for calibrating UHF sensors for GIS applications. 展开更多
关键词 ultra high frequency(UHF) sensors partial discharge detection partial discharge monitoring gas insulated substations(GIS) calibration of sensors calibration cells cone calibration system
下载PDF
A novel algorithm for frequency dependent modeling of ferrite ring and its optimum design to study VFTO behaviors within GIS
2
作者 Mehrdad MAJIDI Hamid JAVADI Moein MANBACHI 《Frontiers in Energy》 SCIE CSCD 2014年第1期90-100,共11页
One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order ... One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemen- ted on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios. 展开更多
关键词 comsol multiphysics EMTP-RV ferrite ring gas insulated substations (GIS) transient over-voltage insulation coordination
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部