The modified sum-peak method estimates radioactivity by using only the peak and the sum-peak count rates.To verify the modified sum-peak method,the dependence of the full energy peak efficiency on the source-to-detect...The modified sum-peak method estimates radioactivity by using only the peak and the sum-peak count rates.To verify the modified sum-peak method,the dependence of the full energy peak efficiency on the source-to-detector distance in a high-purity germanium detector system was studied using a Geant4 Monte Carlo simulation.The effect of the deadlayer in the germanium crystal was estimated by reference to experiments on 241 Am and the relative efficiency of the detector.The peak efficiency dependence on the source-to-detector distance was compared between the simulation and measurements.The modified sum-peak method is discussed with respect to these peak efficiencies.展开更多
The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles at astrophysical energies. The Trojan-horse method (THM) has been introduced t...The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles at astrophysical energies. The Trojan-horse method (THM) has been introduced to solve the difficulties as a powerful indirect tool. In order to understand experimentM spectra better, Geant4 is employed to simulate the method. Validity and reliability of simulation data are examined by comparing the experimental data with simulated results. The Geant4 simulation of THM future related experiments. improves data analysis and is beneficial to the design for展开更多
Since many industrial applications rely on the processing of densely packed and moving granular ma-terial,obtaining bulk internal information on the particle movement inside the reactors is of great importance.Such in...Since many industrial applications rely on the processing of densely packed and moving granular ma-terial,obtaining bulk internal information on the particle movement inside the reactors is of great importance.Such information can be delivered by Positron Emission Particle Tracking(PEPT).By marking pellets with a positron-emitting radioisotope,the position of these tracer particles can be determined via the time-of-flight differences of the emitted gamma-ray pairs.The current paper proposes a PET-like detector system based on cost-effective organic plastic scintillators instead of the more common but expensive inorganic scintillators.This system is currently under construction and was tested for its resolution and efficiency in this simulation study.Using Monte Carlo simulations and the software toolkit Geant4,three different geometries(an empty glass box,a generic grate system,and a cubic box of 1 m3 completely filled with pellets)were investigated,leading to a spatial resolution in the millimeter range and an efficiency,defined as the ratio of reconstructed decay locations to simulated decays,of 2.7%,1.4%,and 0.3%.展开更多
文摘The modified sum-peak method estimates radioactivity by using only the peak and the sum-peak count rates.To verify the modified sum-peak method,the dependence of the full energy peak efficiency on the source-to-detector distance in a high-purity germanium detector system was studied using a Geant4 Monte Carlo simulation.The effect of the deadlayer in the germanium crystal was estimated by reference to experiments on 241 Am and the relative efficiency of the detector.The peak efficiency dependence on the source-to-detector distance was compared between the simulation and measurements.The modified sum-peak method is discussed with respect to these peak efficiencies.
基金Supported by National Natural Science Foundation of China(11075218,10575132)Beijing Natural Science Foundation(1122017)
文摘The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles at astrophysical energies. The Trojan-horse method (THM) has been introduced to solve the difficulties as a powerful indirect tool. In order to understand experimentM spectra better, Geant4 is employed to simulate the method. Validity and reliability of simulation data are examined by comparing the experimental data with simulated results. The Geant4 simulation of THM future related experiments. improves data analysis and is beneficial to the design for
基金funded by the DeutscheForschungsgemeinschaft(DFG,German Research Foundation)through 422037413-CRC/TRR 287"BULK-REACTION"。
文摘Since many industrial applications rely on the processing of densely packed and moving granular ma-terial,obtaining bulk internal information on the particle movement inside the reactors is of great importance.Such information can be delivered by Positron Emission Particle Tracking(PEPT).By marking pellets with a positron-emitting radioisotope,the position of these tracer particles can be determined via the time-of-flight differences of the emitted gamma-ray pairs.The current paper proposes a PET-like detector system based on cost-effective organic plastic scintillators instead of the more common but expensive inorganic scintillators.This system is currently under construction and was tested for its resolution and efficiency in this simulation study.Using Monte Carlo simulations and the software toolkit Geant4,three different geometries(an empty glass box,a generic grate system,and a cubic box of 1 m3 completely filled with pellets)were investigated,leading to a spatial resolution in the millimeter range and an efficiency,defined as the ratio of reconstructed decay locations to simulated decays,of 2.7%,1.4%,and 0.3%.