[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga...[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.展开更多
A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). ...A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). Gel permeation chromatography(GPC) was used to evaluate the molecular weight of synthesized CAR-CBA. Polyethyleneimine(PEI) with molecular weight of 25 kDa was adopted as a reference, and polyethylene glycols(PEG) with different molecular weights were used to establish a standard curve for determining the molecular weight of CAR-CBA. The effects of two critical factors, namely columns and eluents,on the molecular weight measurement of CAR-CBA were investigated to optimize the GPC quantitative method. The results showed that Ultrahydrogel columns(120, 250) and HAc–NaAc(0.5 M, pH 4.5) buffer solution were the optimal column and GPC eluent, respectively.The molecular weight of the synthesized CAR-CBA was analyzed by the optimized GPC method and determined to be 24.66 kDa.展开更多
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s...A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.展开更多
The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas ...The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control.展开更多
Ten fractionated samples of Chinese lacquer polysaccharide in aqueous 0.1M NaC1 solution were studied by aqueous-phase gel permeation chromatography (GPC). The universal calibration, broad MWD calibration and correc...Ten fractionated samples of Chinese lacquer polysaccharide in aqueous 0.1M NaC1 solution were studied by aqueous-phase gel permeation chromatography (GPC). The universal calibration, broad MWD calibration and corrected column dispersion were adopted to the analysis of GPC chromatograms of the polysaccharide. The molecular weights M;, M;and polydispersity index M;/M;obtained from GPC are in good agreement with the results of light scattering and membrane osmometry. It is verified that the universal calibration concept is applicable to the lacquer polysaccharide having a number of side chains.展开更多
Conventional plasticizers deteriorate mechanical and viscoelastic properties of the propellants due to their migration upon aging and long-term storage,which affects reliability and safety properties during exploitati...Conventional plasticizers deteriorate mechanical and viscoelastic properties of the propellants due to their migration upon aging and long-term storage,which affects reliability and safety properties during exploitation.To address this issue,conventional plasticizer,dioctyl adipate(DOA),is replaced by reactive one,castor oil(CO).In addition,three different types of HTPB were used to obtain propellants with designed viscoelastic and mechanical properties.The CO increased propellants viscosity,without a significant impact on the propellant processability,regardless to the type of prepolymer.Conversely,mechanical properties were different depending on the type of resin,which were further analyzed by gel permeation chromatography(GPC).Addition of CO formed a denser polymer network and shifted T_(g) to higher values,compared to the compositions with DOA.The tensile strength of CO-containing propellants was lower at +20℃ and +50℃ compared to the reference compositions,while the strain at maximum load and strain at break were significantly increased with pronounced plastic deformation,especially for samples at -30℃.The inclusion of CO in the propellants composition gives more room for adjusting a wide range of mechanical properties.展开更多
The thermal aging behavior of poly ( vinyl alcohol ) ( PVA ) hydrogel was studied at four different temperatures of 40 ℃, 50 ℃, 60 ℃ and 70 ℃ in one year. The samples of PVA hydrogel were closely covered by pl...The thermal aging behavior of poly ( vinyl alcohol ) ( PVA ) hydrogel was studied at four different temperatures of 40 ℃, 50 ℃, 60 ℃ and 70 ℃ in one year. The samples of PVA hydrogel were closely covered by plastic film. The changes of their chemical structures and physical properties during aging were measured through different measurable techniques including tensile testing, gel permeation chromatography ( GPC ), viscosity analysis, and Fourier transform infrared (FTIR) spec- trum. The results showed that the molecular weight of PVA in hydrogel changed little with time and temperature. FTIR spectra of PVA in all the samples were similar to those of the original samples. The tensile strength of PVA hydrogel didn't change until the 330th days.展开更多
基金Supported by The Fourth Batch of High-end Talent Project in Hebei Province.
文摘[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.
基金the National Natural Science Foundation of China for financial support(No.81373335)
文摘A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). Gel permeation chromatography(GPC) was used to evaluate the molecular weight of synthesized CAR-CBA. Polyethyleneimine(PEI) with molecular weight of 25 kDa was adopted as a reference, and polyethylene glycols(PEG) with different molecular weights were used to establish a standard curve for determining the molecular weight of CAR-CBA. The effects of two critical factors, namely columns and eluents,on the molecular weight measurement of CAR-CBA were investigated to optimize the GPC quantitative method. The results showed that Ultrahydrogel columns(120, 250) and HAc–NaAc(0.5 M, pH 4.5) buffer solution were the optimal column and GPC eluent, respectively.The molecular weight of the synthesized CAR-CBA was analyzed by the optimized GPC method and determined to be 24.66 kDa.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY17C200009)the Foundation of Zhejiang Educational Committee(No.Y201328477)
文摘A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.
文摘The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control.
文摘Ten fractionated samples of Chinese lacquer polysaccharide in aqueous 0.1M NaC1 solution were studied by aqueous-phase gel permeation chromatography (GPC). The universal calibration, broad MWD calibration and corrected column dispersion were adopted to the analysis of GPC chromatograms of the polysaccharide. The molecular weights M;, M;and polydispersity index M;/M;obtained from GPC are in good agreement with the results of light scattering and membrane osmometry. It is verified that the universal calibration concept is applicable to the lacquer polysaccharide having a number of side chains.
基金the support of this research from the Serbian Ministry of Education,Science and Technological Development(Grant No.451-03-68/2023-14/200325)Ministry of Defense(Grant No.VA-TT/1/22-24)。
文摘Conventional plasticizers deteriorate mechanical and viscoelastic properties of the propellants due to their migration upon aging and long-term storage,which affects reliability and safety properties during exploitation.To address this issue,conventional plasticizer,dioctyl adipate(DOA),is replaced by reactive one,castor oil(CO).In addition,three different types of HTPB were used to obtain propellants with designed viscoelastic and mechanical properties.The CO increased propellants viscosity,without a significant impact on the propellant processability,regardless to the type of prepolymer.Conversely,mechanical properties were different depending on the type of resin,which were further analyzed by gel permeation chromatography(GPC).Addition of CO formed a denser polymer network and shifted T_(g) to higher values,compared to the compositions with DOA.The tensile strength of CO-containing propellants was lower at +20℃ and +50℃ compared to the reference compositions,while the strain at maximum load and strain at break were significantly increased with pronounced plastic deformation,especially for samples at -30℃.The inclusion of CO in the propellants composition gives more room for adjusting a wide range of mechanical properties.
文摘The thermal aging behavior of poly ( vinyl alcohol ) ( PVA ) hydrogel was studied at four different temperatures of 40 ℃, 50 ℃, 60 ℃ and 70 ℃ in one year. The samples of PVA hydrogel were closely covered by plastic film. The changes of their chemical structures and physical properties during aging were measured through different measurable techniques including tensile testing, gel permeation chromatography ( GPC ), viscosity analysis, and Fourier transform infrared (FTIR) spec- trum. The results showed that the molecular weight of PVA in hydrogel changed little with time and temperature. FTIR spectra of PVA in all the samples were similar to those of the original samples. The tensile strength of PVA hydrogel didn't change until the 330th days.