Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this...Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.展开更多
Recent research on the underlying mechanisms of cerebral ischemia indicates that the neurovascular unit can be used as a novel subject for general surveys of neuronal damage and protein mechanisms.Fingolimod(FTY-720)i...Recent research on the underlying mechanisms of cerebral ischemia indicates that the neurovascular unit can be used as a novel subject for general surveys of neuronal damage and protein mechanisms.Fingolimod(FTY-720)is a newly developed immunosuppressant isolated from Cordyceps sinensis that exhibits a wide range of biological activities,and has recently attracted much attention for the treatment of ischemic cerebrovascular diseases.In the current research,the role of FTY-720 and its possible mechanisms were assessed from an neurovascular unit perspective using a rat cerebral ischemia model.Our results revealed that FTY-720 markedly decreased infarct volume,promoted neurological function recovery,and weakened the blood-brain barrier permeability of ischemic rats.The protective roles of FTY-720 in ischemic stroke are ascribed to a combination of sphingosin-1-phosphate receptor-1 and reduced expression of sphingosin-1-phosphate receptor-1 in microvessels and reduction of interleukin-17A protein levels.These findings indicate that FTY-720 has promise as a new therapy for neurovascular protection and functional recovery after ischemic stroke.展开更多
In consideration of the global optimization for engineering projects, a group of calculation formulas have been derived by means of theoretical derivation and model tests. On this basis, a design procedure for the dis...In consideration of the global optimization for engineering projects, a group of calculation formulas have been derived by means of theoretical derivation and model tests. On this basis, a design procedure for the distorted units is proposed, by means of which the distorted units of an anology shape and an identical porosity ratio with the original units can be obtained after conducting a distorted enlargement and a normal contraction. The stability waveheight and stability factor of the distorted unit can be calculated with the enlargement factor, a, of the horizontal dimension of the distorted unit, or with the contraction scale, A , of the contracted distorted unit. As a result, the stability of the armor unit can be significantly improved without increasing the quantity of concrete. For the same wave met by the original units, the thickness of placement of the contracted distorted unit can be obviously reduced, thus, a large quantity of concrete can be saved, consequently, economic benefit can be achieved.展开更多
I. Introduction This paper discusses child protection in the United States. I will discuss four general topics. The first topic is United States laws on the protection of children from child abuse and neglect. The se...I. Introduction This paper discusses child protection in the United States. I will discuss four general topics. The first topic is United States laws on the protection of children from child abuse and neglect. The second topic is providing care for children who must be removed from their homes. The third is the role of courts in child protection in the United States.展开更多
In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated qui...In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated quickly and defined exactly. In our study, global information will be introduced into the backup protection system. By analyzing and computing real-time PMU measurements, basing on cluster analysis theory, we are using mainly hierarchical cluster analysis to search after the statistical laws of electrical quantities' marked changes. Then we carry out fast and exact detection of fault components and fault sections, and finally accomplish fault isolation. The facts show that the fault detection of fault component (fault section) can be performed successfully by hierarchical cluster analysis and calculation. The results of hierarchical cluster analysis are accurate and reliable, and the dendrograms of hierarchical cluster analysis are in intuition.展开更多
Although the new technology of protection and automation system of substation based on IEC61850 standard has developed rapidly in China,reliability measures depending on this technology need to be further researched.B...Although the new technology of protection and automation system of substation based on IEC61850 standard has developed rapidly in China,reliability measures depending on this technology need to be further researched.By taking advantage of convenient information sharing,two kinds of new schemes,shared backup protection unit(SBPU)and signal backup(SB),have been proposed to solve the failure problem of protective devices and current/voltage transducers respectively,and the working principle of these two schemes are also described.Furthermore,the key technologies of on-line diagnosis of protective devices'failure and on-line status diagnosis of optical or electronic current/voltage transducers to realize the two schemes are proposed.展开更多
Cathodic Protection system is an efficient system used for protecting the underground metal objects from corrosion. In this paper the use of Cathodic Protection (CP) system and how they can be developed to simulate co...Cathodic Protection system is an efficient system used for protecting the underground metal objects from corrosion. In this paper the use of Cathodic Protection (CP) system and how they can be developed to simulate corrosion control solution was illustrated. The aim of developing a Cathodic Protection system is to provide control over oil pipelines and to reduce the incidence of corrosion. The proposed system integrates the technology of wireless sensor Network (WSN) in order to collect potential data and to realize remote data transmission. In this system each WSN receives the data from the environment and forwards it to a Remote Terminal Unit (RTU). Then each RTU forwards it to its base station (BS). In this work Labview 2010 program was used, due to its high potentials. In addition it contains a Tool Kit that supports the wireless sensor network. In this simulation used many cases study to test and monitoring data and get optimum results, least time delay and high speed to prevent corrosion.展开更多
A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power system...A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station.展开更多
文摘Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.
基金supported by grants from the National Natural Science Foundation of China,No.81971231(to JL)Liaoning Revitalization Talents Program,No.XLYC1907178(to JL)。
文摘Recent research on the underlying mechanisms of cerebral ischemia indicates that the neurovascular unit can be used as a novel subject for general surveys of neuronal damage and protein mechanisms.Fingolimod(FTY-720)is a newly developed immunosuppressant isolated from Cordyceps sinensis that exhibits a wide range of biological activities,and has recently attracted much attention for the treatment of ischemic cerebrovascular diseases.In the current research,the role of FTY-720 and its possible mechanisms were assessed from an neurovascular unit perspective using a rat cerebral ischemia model.Our results revealed that FTY-720 markedly decreased infarct volume,promoted neurological function recovery,and weakened the blood-brain barrier permeability of ischemic rats.The protective roles of FTY-720 in ischemic stroke are ascribed to a combination of sphingosin-1-phosphate receptor-1 and reduced expression of sphingosin-1-phosphate receptor-1 in microvessels and reduction of interleukin-17A protein levels.These findings indicate that FTY-720 has promise as a new therapy for neurovascular protection and functional recovery after ischemic stroke.
文摘In consideration of the global optimization for engineering projects, a group of calculation formulas have been derived by means of theoretical derivation and model tests. On this basis, a design procedure for the distorted units is proposed, by means of which the distorted units of an anology shape and an identical porosity ratio with the original units can be obtained after conducting a distorted enlargement and a normal contraction. The stability waveheight and stability factor of the distorted unit can be calculated with the enlargement factor, a, of the horizontal dimension of the distorted unit, or with the contraction scale, A , of the contracted distorted unit. As a result, the stability of the armor unit can be significantly improved without increasing the quantity of concrete. For the same wave met by the original units, the thickness of placement of the contracted distorted unit can be obviously reduced, thus, a large quantity of concrete can be saved, consequently, economic benefit can be achieved.
文摘I. Introduction This paper discusses child protection in the United States. I will discuss four general topics. The first topic is United States laws on the protection of children from child abuse and neglect. The second topic is providing care for children who must be removed from their homes. The third is the role of courts in child protection in the United States.
文摘In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated quickly and defined exactly. In our study, global information will be introduced into the backup protection system. By analyzing and computing real-time PMU measurements, basing on cluster analysis theory, we are using mainly hierarchical cluster analysis to search after the statistical laws of electrical quantities' marked changes. Then we carry out fast and exact detection of fault components and fault sections, and finally accomplish fault isolation. The facts show that the fault detection of fault component (fault section) can be performed successfully by hierarchical cluster analysis and calculation. The results of hierarchical cluster analysis are accurate and reliable, and the dendrograms of hierarchical cluster analysis are in intuition.
基金National Natural Science Foundation of China(No.50777068).
文摘Although the new technology of protection and automation system of substation based on IEC61850 standard has developed rapidly in China,reliability measures depending on this technology need to be further researched.By taking advantage of convenient information sharing,two kinds of new schemes,shared backup protection unit(SBPU)and signal backup(SB),have been proposed to solve the failure problem of protective devices and current/voltage transducers respectively,and the working principle of these two schemes are also described.Furthermore,the key technologies of on-line diagnosis of protective devices'failure and on-line status diagnosis of optical or electronic current/voltage transducers to realize the two schemes are proposed.
文摘Cathodic Protection system is an efficient system used for protecting the underground metal objects from corrosion. In this paper the use of Cathodic Protection (CP) system and how they can be developed to simulate corrosion control solution was illustrated. The aim of developing a Cathodic Protection system is to provide control over oil pipelines and to reduce the incidence of corrosion. The proposed system integrates the technology of wireless sensor Network (WSN) in order to collect potential data and to realize remote data transmission. In this system each WSN receives the data from the environment and forwards it to a Remote Terminal Unit (RTU). Then each RTU forwards it to its base station (BS). In this work Labview 2010 program was used, due to its high potentials. In addition it contains a Tool Kit that supports the wireless sensor network. In this simulation used many cases study to test and monitoring data and get optimum results, least time delay and high speed to prevent corrosion.
文摘A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station.