High-purity germanium(HPGe)detectors,which are used for direct dark matter detection,have the advantages of a low threshold and excellent energy resolution.The surface passivation of HPGe has become crucial for achiev...High-purity germanium(HPGe)detectors,which are used for direct dark matter detection,have the advantages of a low threshold and excellent energy resolution.The surface passivation of HPGe has become crucial for achieving an extremely low energy threshold.In this study,first-principles simulations,passivation film preparation,and metal oxide semiconductor(MOS)capacitor characterization were combined to study surface passivation.Theoretical calculations of the energy band structure of the -H,-OH,and -NH_(2) passivation groups on the surface of Ge were performed,and the interface state density and potential with five different passivation groups with N/O atomic ratios were accurately analyzed to obtain a stable surface state.Based on the theoretical calculation results,the surface passivation layers of the Ge_(2)ON_(2) film were prepared via magnetron sputtering in accordance with the optimum atomic ratio structure.The microstructure,C-V,and I-V electrical properties of the layers,and the passivation effect of the Al/Ge_(2)ON_(2)/Ge MOS were characterized to test the interface state density.The mean interface state density obtained by the Terman method was 8.4×10^(11) cm^(-2) eV^(-1).The processing of germanium oxynitrogen passivation films is expected to be used in direct dark matter detection of the HPGe detector surface passivation technology to reduce the detector leakage currents.展开更多
High-performance germanium(Ge)waveguide photodetectors are designed and fabricated utilizing the inductivegain-peaking technique.With the appropriate integrated inductors,the 3-dB bandwidth of photodetectors is signif...High-performance germanium(Ge)waveguide photodetectors are designed and fabricated utilizing the inductivegain-peaking technique.With the appropriate integrated inductors,the 3-dB bandwidth of photodetectors is significantly improved owing to the inductive-gain-peaking effect without any compromises to the dark current and optical responsivity.Measured 3-dB bandwidth up to 75 GHz is realized and clear open eye diagrams at 64 Gbps are observed.In this work,the relationship between the frequency response and large signal transmission characteristics on the integrated inductors of Ge waveguide photodetectors is investigated,which indicates the high-speed performance of photodetectors using the inductive-gainpeaking technique.展开更多
目的:鉴于脓毒症的高发病率和高病死率,早期识别高风险患者并及时干预至关重要,而现有死亡风险预测模型在操作、适用性和预测长期预后等方面均存在不足。本研究旨在探讨脓毒症患者死亡的危险因素,构建近期和远期死亡风险预测模型。方法...目的:鉴于脓毒症的高发病率和高病死率,早期识别高风险患者并及时干预至关重要,而现有死亡风险预测模型在操作、适用性和预测长期预后等方面均存在不足。本研究旨在探讨脓毒症患者死亡的危险因素,构建近期和远期死亡风险预测模型。方法:从美国重症监护医学信息数据库IV(Medical Information Mart for Intensive Care-IV,MIMIC-IV)中选取符合脓毒症3.0诊断标准的人群,按7?3的比例随机分为建模组和验证组,分析患者的基线资料。采用单因素Cox回归分析和全子集回归确定脓毒症患者死亡的危险因素并筛选出构建预测模型的变量。分别用时间依赖性曲线下面积(area under the curve,AUC)、校准曲线和决策曲线评估模型的区分度、校准度和临床实用性。结果:共纳入14240例脓毒症患者,28 d和1年病死率分别为21.45%(3054例)和36.50%(5198例)。高龄、女性、高感染相关器官衰竭评分(sepsis-related organ failure assessment,SOFA)、高简明急性生理学评分(simplified acute physiology score II,SAPS II)、心率快、呼吸频率快、脓毒症休克、充血性心力衰竭、慢性阻塞性肺疾病、肝脏疾病、肾脏疾病、糖尿病、恶性肿瘤、高白细胞计数(white blood cell count,WBC)、长凝血酶原时间(prothrombin time,PT)、高血肌酐(serum creatinine,SCr)水平均为脓毒症死亡的危险因素(均P<0.05)。由PT、呼吸频率、体温、合并恶性肿瘤、合并肝脏疾病、脓毒症休克、SAPS II及年龄8个变量构建的模型,其28 d和1年生存的AUC分别为0.717(95%CI 0.710~0.724)和0.716(95%CI 0.707~0.725)。校准曲线和决策曲线表明该模型具有良好的校准度及较好的临床应用价值。结论:基于MIMIC-IV建立的脓毒症患者近期和远期死亡风险预测模型有较好的识别能力,对患者预后风险评估及干预治疗具有一定的临床参考意义。展开更多
The growth of high-quality germanium tin(Ge_(1–y)Sn_(y))binary alloys on a Si substrate using chemical vapor deposition(CVD)techniques holds immense potential for advancing electronics and optoelectronics application...The growth of high-quality germanium tin(Ge_(1–y)Sn_(y))binary alloys on a Si substrate using chemical vapor deposition(CVD)techniques holds immense potential for advancing electronics and optoelectronics applications,including the development of efficient and low-cost mid-infrared detectors and light sources.However,achieving precise control over the Sn concentration and strain relaxation of the Ge_(1–y)Sn_(y)epilayer,which directly influence its optical and electrical properties,remain a significant challenge.In this research,the effect of strain relaxation on the growth rate of Ge_(1–y)Sn_(y)epilayers,with Sn concentration>11at.%,is investigated.It is successfully demonstrated that the growth rate slows down by~55%due to strain relaxation after passing its critical thickness,which suggests a reduction in the incorporation of Ge into Ge_(1–y)Sn_(y)growing layers.Despite the increase in Sn concentration as a result of the decrease in the growth rate,it has been found that the Sn incorporation rate into Ge_(1–y)Sn_(y)growing layers has also decreased due to strain relaxation.Such valuable insights could offer a foundation for the development of innovative growth techniques aimed at achieving high-quality Ge_(1–y)Sn_(y)epilayers with tuned Sn concentration and strain relaxation.展开更多
To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resul...To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively.展开更多
Objective This study aimed to establish a neural cell injury model in vitro by stimulating PC12 cells with lipopolysaccharide(LPS)and to examine the effects of astragaloside IV on key targets using high-throughput seq...Objective This study aimed to establish a neural cell injury model in vitro by stimulating PC12 cells with lipopolysaccharide(LPS)and to examine the effects of astragaloside IV on key targets using high-throughput sequence technology and bioinformatics analyses.Methods PC12 cells in the logarithmic growth phase were treated with LPS at final concentrations of 0.25,0.5,0.75,1,and 1.25 mg/mL for 24 h.Cell morphology was evaluated,and cell survival rates were calculated.A neurocyte inflammatory model was established with LPS treatment,which reached a 50%cell survival rate.PC12 cells were treated with 0.01,0.1,1,10,or 100µmol/L astragaloside IV for 24 h.The concentration of astragaloside IV that did not affect the cell survival rate was selected as the treatment group for subsequent experiments.NOS activity was detected by colorimetry;the expression levels of ERCC2,XRCC4,XRCC2,TNF-α,IL-1β,TLR4,NOS and COX-2 mRNA and protein were detected by RT-qPCR and Western blotting.The differentially expressed genes(DEGs)between the groups were screened using a second-generation sequence(fold change>2,P<0.05)with the following KEGG enrichment analysis,RT-qPCR and Western blotting were used to detect the mRNA and protein expression of DEGs related to the IL-17 pathway in different groups of PC12 cells.Results The viability of PC12 cells was not altered by treatment with 0.01,0.1,or 1µmol/L astragaloside IV for 24 h(P>0.05).However,after treatment with 0.5,0.75,1,or 1.25 mg/mL LPS for 24 h,the viability steadily decreased(P<0.01).The mRNA and protein expression levels of ERCC2,XRCC4,XRCC2,TNF-α,IL-1β,TLR4,NOS,and COX-2 were significantly increased after PC12 cells were treated with 1 mg/mL LPS for 24 h(P<0.01);however,these changes were reversed when PC12 cells were pretreated with 0.01,0.1,or 1µmol/L astragaloside IV in PC12 cells and then treated with 1 mg/mL LPS for 24 h(P<0.05).Second-generation sequencing revealed that 1026 genes were upregulated,while 1287 genes were downregulated.The DEGs were associated with autophagy,TNF-α,interleukin-17,MAPK,P53,Toll-like receptor,and NOD-like receptor signaling pathways.Furthermore,PC12 cells treated with a 1 mg/mL LPS for 24 h exhibited increased mRNA and protein expression of CCL2,CCL11,CCL7,MMP3,and MMP10,which are associated with the IL-17 pathway.RT-qPCR and Western blotting analyses confirmed that the DEGs listed above corresponded to the sequence assay results.Conclusion LPS can damage PC12 cells and cause inflammatory reactions in nerve cells and DNA damage.astragaloside IV plays an anti-inflammatory and DNA damage protective role and inhibits the IL-17 signaling pathway to exert a neuroprotective effect in vitro.展开更多
The single event effect(SEE) sensitivity of silicon–germanium heterojunction bipolar transistor(Si Ge HBT) irradiated by 100-Me V proton is investigated. The simulation results indicate that the most sensitive positi...The single event effect(SEE) sensitivity of silicon–germanium heterojunction bipolar transistor(Si Ge HBT) irradiated by 100-Me V proton is investigated. The simulation results indicate that the most sensitive position of the Si Ge HBT device is the emitter center, where the protons pass through the larger collector-substrate(CS) junction. Furthermore, in this work the experimental studies are also carried out by using 100-Me V proton. In order to consider the influence of temperature on SEE, both simulation and experiment are conducted at a temperature of 93 K. At a cryogenic temperature, the carrier mobility increases, which leads to higher transient current peaks, but the duration of the current decreases significantly.Notably, at the same proton flux, there is only one single event transient(SET) that occurs at 93 K. Thus, the radiation hard ability of the device increases at cryogenic temperatures. The simulation results are found to be qualitatively consistent with the experimental results of 100-Me V protons. To further evaluate the tolerance of the device, the influence of proton on Si Ge HBT after gamma-ray(^(60)Coγ) irradiation is investigated. As a result, as the cumulative dose increases, the introduction of traps results in a significant reduction in both the peak value and duration of the transient currents.展开更多
基金supported by the National Natural Science Foundation of China(No.12005017).
文摘High-purity germanium(HPGe)detectors,which are used for direct dark matter detection,have the advantages of a low threshold and excellent energy resolution.The surface passivation of HPGe has become crucial for achieving an extremely low energy threshold.In this study,first-principles simulations,passivation film preparation,and metal oxide semiconductor(MOS)capacitor characterization were combined to study surface passivation.Theoretical calculations of the energy band structure of the -H,-OH,and -NH_(2) passivation groups on the surface of Ge were performed,and the interface state density and potential with five different passivation groups with N/O atomic ratios were accurately analyzed to obtain a stable surface state.Based on the theoretical calculation results,the surface passivation layers of the Ge_(2)ON_(2) film were prepared via magnetron sputtering in accordance with the optimum atomic ratio structure.The microstructure,C-V,and I-V electrical properties of the layers,and the passivation effect of the Al/Ge_(2)ON_(2)/Ge MOS were characterized to test the interface state density.The mean interface state density obtained by the Terman method was 8.4×10^(11) cm^(-2) eV^(-1).The processing of germanium oxynitrogen passivation films is expected to be used in direct dark matter detection of the HPGe detector surface passivation technology to reduce the detector leakage currents.
基金supported by the National Key Research and Development Program of China(2020YFB2206103)National Natural Science Foundation of China(61975196)Youth Innovation Promotion Association Chinese Academy of Sciences(2021111)。
文摘High-performance germanium(Ge)waveguide photodetectors are designed and fabricated utilizing the inductivegain-peaking technique.With the appropriate integrated inductors,the 3-dB bandwidth of photodetectors is significantly improved owing to the inductive-gain-peaking effect without any compromises to the dark current and optical responsivity.Measured 3-dB bandwidth up to 75 GHz is realized and clear open eye diagrams at 64 Gbps are observed.In this work,the relationship between the frequency response and large signal transmission characteristics on the integrated inductors of Ge waveguide photodetectors is investigated,which indicates the high-speed performance of photodetectors using the inductive-gainpeaking technique.
文摘目的:鉴于脓毒症的高发病率和高病死率,早期识别高风险患者并及时干预至关重要,而现有死亡风险预测模型在操作、适用性和预测长期预后等方面均存在不足。本研究旨在探讨脓毒症患者死亡的危险因素,构建近期和远期死亡风险预测模型。方法:从美国重症监护医学信息数据库IV(Medical Information Mart for Intensive Care-IV,MIMIC-IV)中选取符合脓毒症3.0诊断标准的人群,按7?3的比例随机分为建模组和验证组,分析患者的基线资料。采用单因素Cox回归分析和全子集回归确定脓毒症患者死亡的危险因素并筛选出构建预测模型的变量。分别用时间依赖性曲线下面积(area under the curve,AUC)、校准曲线和决策曲线评估模型的区分度、校准度和临床实用性。结果:共纳入14240例脓毒症患者,28 d和1年病死率分别为21.45%(3054例)和36.50%(5198例)。高龄、女性、高感染相关器官衰竭评分(sepsis-related organ failure assessment,SOFA)、高简明急性生理学评分(simplified acute physiology score II,SAPS II)、心率快、呼吸频率快、脓毒症休克、充血性心力衰竭、慢性阻塞性肺疾病、肝脏疾病、肾脏疾病、糖尿病、恶性肿瘤、高白细胞计数(white blood cell count,WBC)、长凝血酶原时间(prothrombin time,PT)、高血肌酐(serum creatinine,SCr)水平均为脓毒症死亡的危险因素(均P<0.05)。由PT、呼吸频率、体温、合并恶性肿瘤、合并肝脏疾病、脓毒症休克、SAPS II及年龄8个变量构建的模型,其28 d和1年生存的AUC分别为0.717(95%CI 0.710~0.724)和0.716(95%CI 0.707~0.725)。校准曲线和决策曲线表明该模型具有良好的校准度及较好的临床应用价值。结论:基于MIMIC-IV建立的脓毒症患者近期和远期死亡风险预测模型有较好的识别能力,对患者预后风险评估及干预治疗具有一定的临床参考意义。
文摘The growth of high-quality germanium tin(Ge_(1–y)Sn_(y))binary alloys on a Si substrate using chemical vapor deposition(CVD)techniques holds immense potential for advancing electronics and optoelectronics applications,including the development of efficient and low-cost mid-infrared detectors and light sources.However,achieving precise control over the Sn concentration and strain relaxation of the Ge_(1–y)Sn_(y)epilayer,which directly influence its optical and electrical properties,remain a significant challenge.In this research,the effect of strain relaxation on the growth rate of Ge_(1–y)Sn_(y)epilayers,with Sn concentration>11at.%,is investigated.It is successfully demonstrated that the growth rate slows down by~55%due to strain relaxation after passing its critical thickness,which suggests a reduction in the incorporation of Ge into Ge_(1–y)Sn_(y)growing layers.Despite the increase in Sn concentration as a result of the decrease in the growth rate,it has been found that the Sn incorporation rate into Ge_(1–y)Sn_(y)growing layers has also decreased due to strain relaxation.Such valuable insights could offer a foundation for the development of innovative growth techniques aimed at achieving high-quality Ge_(1–y)Sn_(y)epilayers with tuned Sn concentration and strain relaxation.
基金This work was supported by the National Key R&D Program of China(Nos.2022YFF0709503,2022YFB1902700,2017YFC0602101)the Key Research and Development Program of Sichuan province(No.2023YFG0347)the Key Research and Development Program of Sichuan province(No.2020ZDZX0007).
文摘To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively.
基金supported by grants from Open Project of Gansu Traditional Chinese Medicine Research Center(No.zyzx-2020-10)Gansu Province Youth Science and Technology Foundation Program(No.21JR7RA652)+1 种基金Gansu Province Higher Education Research(No.2018A-049)Gansu Province Higher Education Research(No.2021B-163).
文摘Objective This study aimed to establish a neural cell injury model in vitro by stimulating PC12 cells with lipopolysaccharide(LPS)and to examine the effects of astragaloside IV on key targets using high-throughput sequence technology and bioinformatics analyses.Methods PC12 cells in the logarithmic growth phase were treated with LPS at final concentrations of 0.25,0.5,0.75,1,and 1.25 mg/mL for 24 h.Cell morphology was evaluated,and cell survival rates were calculated.A neurocyte inflammatory model was established with LPS treatment,which reached a 50%cell survival rate.PC12 cells were treated with 0.01,0.1,1,10,or 100µmol/L astragaloside IV for 24 h.The concentration of astragaloside IV that did not affect the cell survival rate was selected as the treatment group for subsequent experiments.NOS activity was detected by colorimetry;the expression levels of ERCC2,XRCC4,XRCC2,TNF-α,IL-1β,TLR4,NOS and COX-2 mRNA and protein were detected by RT-qPCR and Western blotting.The differentially expressed genes(DEGs)between the groups were screened using a second-generation sequence(fold change>2,P<0.05)with the following KEGG enrichment analysis,RT-qPCR and Western blotting were used to detect the mRNA and protein expression of DEGs related to the IL-17 pathway in different groups of PC12 cells.Results The viability of PC12 cells was not altered by treatment with 0.01,0.1,or 1µmol/L astragaloside IV for 24 h(P>0.05).However,after treatment with 0.5,0.75,1,or 1.25 mg/mL LPS for 24 h,the viability steadily decreased(P<0.01).The mRNA and protein expression levels of ERCC2,XRCC4,XRCC2,TNF-α,IL-1β,TLR4,NOS,and COX-2 were significantly increased after PC12 cells were treated with 1 mg/mL LPS for 24 h(P<0.01);however,these changes were reversed when PC12 cells were pretreated with 0.01,0.1,or 1µmol/L astragaloside IV in PC12 cells and then treated with 1 mg/mL LPS for 24 h(P<0.05).Second-generation sequencing revealed that 1026 genes were upregulated,while 1287 genes were downregulated.The DEGs were associated with autophagy,TNF-α,interleukin-17,MAPK,P53,Toll-like receptor,and NOD-like receptor signaling pathways.Furthermore,PC12 cells treated with a 1 mg/mL LPS for 24 h exhibited increased mRNA and protein expression of CCL2,CCL11,CCL7,MMP3,and MMP10,which are associated with the IL-17 pathway.RT-qPCR and Western blotting analyses confirmed that the DEGs listed above corresponded to the sequence assay results.Conclusion LPS can damage PC12 cells and cause inflammatory reactions in nerve cells and DNA damage.astragaloside IV plays an anti-inflammatory and DNA damage protective role and inhibits the IL-17 signaling pathway to exert a neuroprotective effect in vitro.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.61574171,61704127,11875229,51872251,and 12027813)。
文摘The single event effect(SEE) sensitivity of silicon–germanium heterojunction bipolar transistor(Si Ge HBT) irradiated by 100-Me V proton is investigated. The simulation results indicate that the most sensitive position of the Si Ge HBT device is the emitter center, where the protons pass through the larger collector-substrate(CS) junction. Furthermore, in this work the experimental studies are also carried out by using 100-Me V proton. In order to consider the influence of temperature on SEE, both simulation and experiment are conducted at a temperature of 93 K. At a cryogenic temperature, the carrier mobility increases, which leads to higher transient current peaks, but the duration of the current decreases significantly.Notably, at the same proton flux, there is only one single event transient(SET) that occurs at 93 K. Thus, the radiation hard ability of the device increases at cryogenic temperatures. The simulation results are found to be qualitatively consistent with the experimental results of 100-Me V protons. To further evaluate the tolerance of the device, the influence of proton on Si Ge HBT after gamma-ray(^(60)Coγ) irradiation is investigated. As a result, as the cumulative dose increases, the introduction of traps results in a significant reduction in both the peak value and duration of the transient currents.