An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct curre...An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct current glow discharge mass spectrometry (GD-MS) was established. MnZn ferrite powder was mixed with copper powder, used as a conductor, and pressed. The effects of MnZn ferrite powder preparation conditions and glow discharge parameters for the sensitivity and stability of signal analysis were investigated. By determining the choice of isotope and the application of the mass resolutions of 4000 (MR, medium resolution) and 10000 (HR, high resolution), mass spectral interference was eliminated. The contents of impurity elements in MnZn ferrite powder was calculated by subtraction after normalizing the total signal of Mn, Zn, Fe, O and Cu. The results showed that the detection limit of 26 kinds of impurity elements was between 0.002 and 0.57 μg/g, and the relative standard deviation (RSD) was between 3.33% and 32.35%. The accuracy of this method was verified by the ICP-MS. The method was simple and practical, which is applied to the determination of impurity elements in MnZn ferrite powder.展开更多
The paper investigated a new method of analyzing perfume odors.The study adopted IMS with glow dischargeas ion source and with positive ion mode.We got the quality characteristics of perfume odors in this way without ...The paper investigated a new method of analyzing perfume odors.The study adopted IMS with glow dischargeas ion source and with positive ion mode.We got the quality characteristics of perfume odors in this way without any collection and concentration process.The quality of perfume odors can be identified by IMS peak characteristics,and the characteristics of different quality of perfume also can be identified.In summary,the IMS is an effective technique in the perfume odor detection,it is also a new way of gas sample analysis.展开更多
A novel ambient glow discharge ion source with improved line-cylinder electrodes is put forward and designed in this paper. The diameters of inner and outer electrodes are 0.16 and 4 mm respectively. With a special as...A novel ambient glow discharge ion source with improved line-cylinder electrodes is put forward and designed in this paper. The diameters of inner and outer electrodes are 0.16 and 4 mm respectively. With a special assembly method, a perfect coaxiality of the two electrodes is obtained. From the gas discharge experiment, it can be seen that the discharge can stably work in normal glow discharge mode. The operating currents of the ion source are in an order of milliamperes and can generate a much larger number and wider variety of reagent ions. The MS experiment shows that the ion source has higher detection sensitivity,展开更多
基金Project(21275162)supported by the National Natural Science Foundation of ChinaProject(KJZH14217)supported by the Achievement Transfer Program of Institutions of Higher Education in Chongqing,ChinaProject(KJ1601224)supported by the Scientific and Technological Research Program of Chongqing Municipal Education Commission,China
文摘An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct current glow discharge mass spectrometry (GD-MS) was established. MnZn ferrite powder was mixed with copper powder, used as a conductor, and pressed. The effects of MnZn ferrite powder preparation conditions and glow discharge parameters for the sensitivity and stability of signal analysis were investigated. By determining the choice of isotope and the application of the mass resolutions of 4000 (MR, medium resolution) and 10000 (HR, high resolution), mass spectral interference was eliminated. The contents of impurity elements in MnZn ferrite powder was calculated by subtraction after normalizing the total signal of Mn, Zn, Fe, O and Cu. The results showed that the detection limit of 26 kinds of impurity elements was between 0.002 and 0.57 μg/g, and the relative standard deviation (RSD) was between 3.33% and 32.35%. The accuracy of this method was verified by the ICP-MS. The method was simple and practical, which is applied to the determination of impurity elements in MnZn ferrite powder.
文摘The paper investigated a new method of analyzing perfume odors.The study adopted IMS with glow dischargeas ion source and with positive ion mode.We got the quality characteristics of perfume odors in this way without any collection and concentration process.The quality of perfume odors can be identified by IMS peak characteristics,and the characteristics of different quality of perfume also can be identified.In summary,the IMS is an effective technique in the perfume odor detection,it is also a new way of gas sample analysis.
基金supported by the National Natural Science Foundation of China(No.60706030 and No.20827007)the National High Technology Research and Development Plan of China(No.2007AA04Z337)
文摘A novel ambient glow discharge ion source with improved line-cylinder electrodes is put forward and designed in this paper. The diameters of inner and outer electrodes are 0.16 and 4 mm respectively. With a special assembly method, a perfect coaxiality of the two electrodes is obtained. From the gas discharge experiment, it can be seen that the discharge can stably work in normal glow discharge mode. The operating currents of the ion source are in an order of milliamperes and can generate a much larger number and wider variety of reagent ions. The MS experiment shows that the ion source has higher detection sensitivity,