期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evaluation of the Three Glucometer Devices Performance in Comparison with the Cobas Integra 400 Plus Autoanalyzer in Measuring Blood Glucose Levels: A Comparative Cross-Sectional Study
1
作者 Lotfi S. Bin Dahman Ahmed M. Daakeek +2 位作者 Hussein S. Alghazali Abdullah M. Kaity Munir S. Obbed 《Journal of Diabetes Mellitus》 2021年第4期132-142,共11页
<strong>Objective:</strong> The study aimed to evaluate the performance of the three glucometers compared to standard the laboratory method (Cobas Integra 400 Plus) in measuring blood glucose levels. <s... <strong>Objective:</strong> The study aimed to evaluate the performance of the three glucometers compared to standard the laboratory method (Cobas Integra 400 Plus) in measuring blood glucose levels. <strong>Patients and Methods: </strong>A total of 100 Yemeni diabetic patients were randomly recruited into a comparative cross-sectional study. Venous and finger-pricked blood samples were obtained from all participants and used for blood glucose levels measurement following the standard procedures. <strong>Results:</strong> The mean blood glucose levels for one-hundred diabetic patients using the Gluco Contour TS and Gluco SD Codefree were not significantly different compared with the Cobas Integra 400 Plus (12.14 ± 6.89 mmol/L vs. 12.85 ± 8.83 mmol/L, <span style="white-space:normal;"><i></span>P<span style="white-space:normal;"></i></span> = 0.159;12.50 ± 7.18 mmol/L vs. 12.85 ± 8.83 mmol/L, <i>P</i> = 0.490), respectively. However, there is a significant difference using the Gluco Alert device from that of the Cobas Integra 400 Plus (11.83 ± 6.94 mmol/L vs. 12.85 ± 8.83 mmol/L, <span style="white-space:normal;"><i></span>P<span style="white-space:normal;"></i></span> = 0.046). Furthermore, using the ROC curve at a 95% confidence interval, the Cobas Integra 400 Plus showed a significant agreement with the Gluco Contour TS (51.4%), Gluco SD Codefree (50.4%), and Gluco Alert (39.3%), respectively. For determining accuracy, the sensitivity of the glucometer devices was the following: Gluco SD Codefree (87.3%), Contour TS (85.9%), and Gluco Alert (78.9%). In this regard, the highest specificity was related to Gluco Contour TS (65.5%). <strong>Conclusion:</strong> The correlation between both methods was good, with high sensitivity and specificity in measuring blood glucose levels as indicated by the ROC curve. Thus, we suggest using these glucometers at homes and hospitals as a point of care for diabetic patients. 展开更多
关键词 Diabetes Mellitus Blood Glucose Levels glucometers Cobas Integra 400 Plus Autoanalyzer
下载PDF
Self monitoring of blood glucose and its association with glycaemic control and lipid levels in type 2 diabetic patients aged 40 - 75 in Trinidad and Tobago
2
作者 B. Shivananda Nayak Khateija Gowrie +7 位作者 Renelle Romano Carl Spencer Domonique Noel Hellen Bissoon Ikageng Dipatene Nadia Mahabir Rissa Ragbir Shalane Xavier 《Journal of Diabetes Mellitus》 2012年第3期294-300,共7页
This study was done to assess whether self monitoring of blood glucose is associated with better glycaemic control in type 2 diabetic Trinidadians. Data was collected from 146 type 2 diabetics via interviews and medic... This study was done to assess whether self monitoring of blood glucose is associated with better glycaemic control in type 2 diabetic Trinidadians. Data was collected from 146 type 2 diabetics via interviews and medical files. Variables extracted included fasting blood glucose, HbA1c and lipid profile. Recent users of the glucometer had better glycemic control compared with longstanding users (HbA1c: 8.4% ± 0.28% vs 9.4% ± 0.62%). Diabetics using a glucometer for >11 years had the highest cholesterol (234 ± 27mg/dL) while those using it 6 months to 5 yrs had the lowest values (206 ± 8 mg/dL). Using the glucometer occasionally or once a week had little impact on these indices. Usage of insulin preparation was positively correlated with HbA1c (r = 0.295;p = 0.001) while those relying on oral hypoglycaemic agents showed a negative correlation (r = -0.265). Further, those who took their medication as prescribed had a lower HbA1c than those who took their medication occasionally. Ironically, HbA1c fell with increasing duration between clinic visits with those visiting annually having the lowest HbA1c (9.0% ± 0.2% vs 7.1% ± 0.7%). Compliance with lifestyle and exercise resulted in lower HbA1c and blood lipids. Poor client education on glucometer usage, administration of insulin and non-compliance with diet and exercise were associated with higher HbA1c. 展开更多
关键词 glucometer BLOOD GLUCOSE Glycemic Control LIPID Profile
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部