Numerical Simulation and Optimization of a Mid-Temperature Heat Pipe Exchanger 被引量:7
1
作者 Jun Du Xin Wu +1 位作者 Ruonan Li Ranran Cheng 《Fluid Dynamics & Materials Processing》 EI 2019年第1期77-87,共11页
In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.... In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.The effects of different operating parameters and fin parameters on the heat transfer performance of heat exchangers are studied.The results show that the heat transfer performance of the mid-temperature gravity heat pipe exchanger is the best when the fin spacing is between 5 mm and 6 mm,the height of the heat pipe is between 12 mm and 13 mm,and the inlet velocity of the fluid is between 2.5 m/s to 3 m/s. 展开更多
关键词 gravity heat pipe heat exchanger FLUENT numerical simulation heat transfer performance
下载PDF
Energy Saving Model and Calculation Example of Three Cooling Schemes for Data Center in Hot Summer and Cold Winter Area
2
作者 Feihu Chen Xinli Zhou Shuguang Liao 《Journal of Power and Energy Engineering》 2021年第12期1-20,共20页
In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy sa... In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy saving and energy consumption in data center, 5G network and other fields. The gravity heat pipe double cycle air conditioning is a kind of room air conditioning which uses natural cooling source with high efficiency. According to the outdoor meteorological parameters of ten typical cities in China, the calculation model of unit hybrid refrigeration mode is established by using integral method. A simplified algorithm for statistical summation is proposed. Then it compares with the same type of refrigerant pump air conditioner, water-cooled chiller and natural cooling plate. The results show that the annual operation time of gravity heat pipe double cycle air conditioner is 50.8% longer than that of refrigerant pump air conditioner. Then the calculation model is verified by the annual actual operation data of a data center in Changsha. The results show that the double cycle air conditioner with gravity heat pipe can save about 34% energy compared with the chiller. The accuracy of the calculation model is 17.5%, which meets the engineering accuracy requirements. The application of gravity heat pipe double cycle air conditioning in hot summer and cold winter area is a scheme worthy of popularization and application. 展开更多
关键词 gravity heat pipe Double Cycle Refrigerant Pump Natural Cooling Inte-gral Method Simplified Algorithm for Statistical Summation Energy Sav-ing Rate
下载PDF