期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Small-signal modelling and stability analysis of grid-following and grid-forming inverters dominated power system
1
作者 Yaran Li Long Fu +3 位作者 Qiang Li Wei Wang Yubin Jia Zhao Yang Dong 《Global Energy Interconnection》 EI CSCD 2023年第3期363-374,共12页
In this paper,the explicit state-space model for a multi-inverter system including grid-following inverter-based generators(IBGs)and grid-forming IBGs is developed by the two-level component connection method(CCM),whi... In this paper,the explicit state-space model for a multi-inverter system including grid-following inverter-based generators(IBGs)and grid-forming IBGs is developed by the two-level component connection method(CCM),which modularized inverter control blocks at the primary level and IBGs at the secondary level.Based on the comprehensive state-space model representing full order of system dynamics,eigenvalues of the overall system are thoroughly analyzed,identifying potential adverse impacts of not only grid-following inverters,but also grid forming inverters on the system small-signal stability,with the underlying principle of oscillations also understood.Numerical and simulation results validate effectiveness of the proposed methodology on IEEE benchmarking 39-bus system. 展开更多
关键词 grid-following control Grid-forming control State-space modelling Inverter-driven oscillations
下载PDF
Impact of Frequency Anti-windup Limiter on Synchronization Stability of Grid Feeding Converter
2
作者 Junru Chen Chenchen Ge +3 位作者 Di Qiang Hua Geng Terence O'Donnell Federico Milano 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1676-1687,共12页
Loss of synchronization is one of the main issues for a grid-feeding converter in a weak grid after being subjected to a large disturbance.The synchronous transient is highly nonlinear due to phase movement and freque... Loss of synchronization is one of the main issues for a grid-feeding converter in a weak grid after being subjected to a large disturbance.The synchronous transient is highly nonlinear due to phase movement and frequency limiters.However,none of the previous research has considered the anti-windup PI in the phase-locked loop,which is commonly implemented in reality and introduced as an additional nonlinear transient.This work provides a taxonomy to evaluate and compare the effect of different anti-windup PI limiters on synchronization stability,including clamping,back-calculation and combined method.Different anti-windup PI limiters allocate zeros and poles differently and have different impacts on damping and stability enhancement.A case study implemented in Matlab/Simulink serves to compare the trajectory of the converter phase and frequency using different anti-windup PI in the scenario of both with and without equilibrium points during the fault.Simulation results show that anti-windup PI limiters increase damping during the fault and thus improve the synchronization stability margin. 展开更多
关键词 Frequency Limiter(FL) grid-following converter Phase-Locked Loop(PLL) synchronization stability
原文传递
上一页 1 下一页 到第