期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
1
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
2
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location Main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
下载PDF
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
3
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault grounding protection Zero-sequence current ratio coefficient
下载PDF
Multiple Random Forests Based Intelligent Location of Single-phase Grounding Fault in Power Lines of DFIG-based Wind Farm 被引量:1
4
作者 Yongli Zhu Hua Peng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1152-1163,共12页
To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes a... To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes an intelligent location method for a single-phase grounding fault based on a multiple random forests(multi-RF) algorithm. First, the simulation model is built, and the fundamental amplitudes of the zerosequence currents are extracted by a fast Fourier transform(FFT) to construct the feature set. Then, the random forest classification algorithm is applied to establish the fault section locator. The model is resampled on the basis of the bootstrap method to generate multiple sample subsets, which are used to establish multiple classification and regression tree(CART) classifiers. The CART classifiers use the mean decrease in the node impurity as the feature importance,which is used to mine the relationship between features and fault sections. Subsequently, a fault section is identified by voting on the test results for each classifier. Finally, a multi-RF regression fault locator is built to output the predicted fault distance. Experimental results with PSCAD/EMTDC software show that the proposed method can overcome the shortcomings of a single RF and has the advantage of locating a short hybrid overhead/cable line with multiple branches. Compared with support vector machines(SVMs)and previously reported methods, the proposed method can meet the location accuracy and efficiency requirements of a DFIG-based wind farm better. 展开更多
关键词 Doubly-fed induction generator(DFIG)based wind farm power line multiple random forests(multi-RF) single-phase grounding fault fault location
原文传递
Control method based on DRFNN sliding mode for multifunctional flexible multistate switch
5
作者 Jianghua Liao Wei Gao +1 位作者 Yan Yang Gengjie Yang 《Global Energy Interconnection》 EI CSCD 2024年第2期190-205,共16页
To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this st... To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this study.This approach is based on an improved double-loop recursive fuzzy neural network(DRFNN)sliding mode,which is intended to stably achieve multiterminal power interaction and adaptive arc suppression for single-phase ground faults.First,an improved DRFNN sliding mode control(SMC)method is proposed to overcome the chattering and transient overshoot inherent in the classical SMC and reduce the reliance on a precise mathematical model of the control system.To improve the robustness of the system,an adaptive parameter-adjustment strategy for the DRFNN is designed,where its dynamic mapping capabilities are leveraged to improve the transient compensation control.Additionally,a quasi-continuous second-order sliding mode controller with a calculus-driven sliding mode surface is developed to improve the current monitoring accuracy and enhance the system stability.The stability of the proposed method and the convergence of the network parameters are verified using the Lyapunov theorem.A simulation model of the three-port FMS with its control system is constructed in MATLAB/Simulink.The simulation result confirms the feasibility and effectiveness of the proposed control strategy based on a comparative analysis. 展开更多
关键词 Distribution networks Flexible multistate switch grounding fault arc suppression Double-loop recursive fuzzy neural network Quasi-continuous second-order sliding mode
下载PDF
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
6
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
下载PDF
Dominant pulse simulation of near fault ground motions 被引量:10
7
作者 S.R. Hoseini Vaez M.K. Sharbatdar +2 位作者 G. Ghodrati Amiri H. Naderpour A. Kheyroddin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第2期267-278,共12页
In this study, a new mathematical model is developed composed of two parts, including harmonic and polynomial expressions for simulating the dominant velocity pulse of near fault ground motions. Based on a proposed ve... In this study, a new mathematical model is developed composed of two parts, including harmonic and polynomial expressions for simulating the dominant velocity pulse of near fault ground motions. Based on a proposed velocity function, the corresponding expressions for the ground acceleration and displacement time histories are also derived. The proposed model is then fitted using some selected pulse-like near fault ground motions in the Next Generation Attenuation (NGA) project library. The new model is not only simple in form but also simulates the long-period portion of actual velocity near fault records with a high level of precision. It is shown that the proposed model-based elastic response spectra are compatible with the near fault records in the neighborhood of the prevailing frequency of the pulse. The results indicate that the proposed model adequately simulates the components of the time histories. Finally, the energy of the proposed pulse was compared with the energy of the actual record to confirm the compatibility. 展开更多
关键词 dominant pulse near fault ground motions forward directivity response spectra SIMULATION
下载PDF
Traveling wave effect on the seismic response of a steel arch bridge subjected to near fault ground motions 被引量:11
8
作者 徐艳 George C Lee 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第3期245-257,共13页
In the 1990s, several major earthquakes occurred throughout the world, with a common observation that near fault ground motion (NFGM) characteristics had a distinct impact on causing damage to civil engineering stru... In the 1990s, several major earthquakes occurred throughout the world, with a common observation that near fault ground motion (NFGM) characteristics had a distinct impact on causing damage to civil engineering structures that could not be predicted by using far field ground motions. Since then, seismic responses of structures under NFGMs have been extensively examined, with most of the studies focusing on structures with relatively short fundamental periods, where the traveling wave effect does not need to be considered. However, for long span bridges, especially arch bridges, the traveling wave (only time delay considered) effect may be very distinct and is therefore important. In this paper, the results from a case study on the seismic response of a steel arch bridge under selected NFGMs is presented by considering the traveling wave effect with variable apparent velocities. The effects of fling step and long period pulses of NFGMs on the seismic responses of the arch bridge are also discussed. 展开更多
关键词 traveling wave effect arch bridge near fault ground motion fling step long period pulses
下载PDF
Direct use of peak ground motion parameters for the estimation of inelastic displacement ratio of SDOF systems subjected to repeated far fault ground motions 被引量:5
9
作者 Cengizhan Durucan Muhammed Gümüs 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第4期771-785,共15页
This study is aimed at developing statistical equations to estimate the inelastic displacement ratio of singledegree-of-freedom systems subjected to far fault repeated earthquakes. In the study, peak ground motion par... This study is aimed at developing statistical equations to estimate the inelastic displacement ratio of singledegree-of-freedom systems subjected to far fault repeated earthquakes. In the study, peak ground motion parameters are used to define the scatter of the original data. The ratio of peak ground acceleration to peak ground velocity, and peak ground velocity of the ground motion records and structural parameters such as period of vibration and lateral strength ratio are used in the proposed equations. For the development of the equations, nonlinear time history analyses of single-degree-offreedom systems are conducted. Then, the results are used in a multivariate regression procedure. The equations are verified by comparing the estimated results with the calculated results. The average error and coefficient of variation of the proposed equations are presented. The analyses results revealed that the direct use of peak ground motion parameters for the estimation of inelastic displacement ratio significantly reduced the scatter in the original data and yielded accurate results. From the comparative results it is also observed that results obtained using equations specific to peak ground velocity or peak ground acceleration to peak ground velocity ratio are similar. 展开更多
关键词 C1 peak ground velocity peak ground acceleration far fault ground motions sequential ground motions
下载PDF
Faulty Feeder Identification in Resonant Grounding Distribution Networks Based on Deep Learning and Transfer Learning
10
作者 Xiuyong Yu Jun Cao +2 位作者 Zhong Fan Mingming Xu Liye Xiao 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第6期2168-2178,共11页
Identification of faulty feeders in resonant grounding distribution networks remains a significant challenge dueto the weak fault current and complicated working conditions.In this paper, we present a deep learning-ba... Identification of faulty feeders in resonant grounding distribution networks remains a significant challenge dueto the weak fault current and complicated working conditions.In this paper, we present a deep learning-based multi-labelclassification framework to reliably distinguish the faulty feeder.Three different neural networks (NNs) including the multilayerperceptron, one-dimensional convolutional neural network (1DCNN), and 2D CNN are built. However, the labeled data maybe difficult to obtain in the actual environment. We use thesimplified simulation model based on a full-scale test field (FSTF)to obtain sufficient labeled source data. Being different frommost learning-based methods, assuming that the distribution ofsource domain and target domain is identical, we propose asamples-based transfer learning method to improve the domainadaptation by using samples in the source domain with properweights. The TrAdaBoost algorithm is adopted to update theweights of each sample. The recorded data obtained in the FSTFare utilized to test the domain adaptability. According to ourvalidation and testing, the validation accuracies are high whenthere is sufficient labeled data for training the proposed NNs.The proposed 2D CNN has the best domain adaptability. TheTrAdaBoost algorithm can help the NNs to train an efficientclassifier that has better domain adaptation. It has been thereforeconcluded that the proposed method, especially the 2D CNN, issuitable for actual distribution networks. 展开更多
关键词 Deep-learning method faulty feederc identification full-scale test field(FSTF) resonant groundingc distribution network single line to ground fault transfer learning
原文传递
Stability Analysis of PLL Influenced by Control Loops in Grid-connected Converters Under Fault Disturbance 被引量:8
11
作者 Yushuang Liu Meng Huang +1 位作者 Xiaoming Zha Herbert Ho-Ching Iu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期239-248,共10页
When the power grid suffers from grid faults that cause phase disturbances,the grid-connected converter becomes destabilized by the interaction between the phase-locked loop(PLL)and the control loop.In this paper,the ... When the power grid suffers from grid faults that cause phase disturbances,the grid-connected converter becomes destabilized by the interaction between the phase-locked loop(PLL)and the control loop.In this paper,the stability of the PLL affected by the control loop under transient grid faults is studied.First,the equivalent model of the PLL under the influence of the control loop is established.Then,different response processes of PLLs under the ground fault with various control parameters are qualitatively analyzed.Furthermore,a small-signal model is proposed to assess the stability of the PLL under different control loop parameters.The system poles can be calculated to show the physical origin of the instability.Finally,simulations of a three-phase 21-level modular multilevel converter(MMC)built in PSCAD and a down-scale experiment is performed to verify the parameter influence of the control loop on the PLL. 展开更多
关键词 Control loop grid-connected MMC ground fault phase-locked loop transient stability
原文传递
The ground deformation field induced by a listric thrust fault with an overburden soil layer
12
作者 Shaogang ZENG Yong'en CAI 《Frontiers of Earth Science》 SCIE CAS CSCD 2013年第4期501-507,共7页
The surface deformation field induced by a listric thrust fault with a thick, overburden soil layer is studied in this paper by the finite element method (FEM). The results show: (a) The maximum slip induced by t... The surface deformation field induced by a listric thrust fault with a thick, overburden soil layer is studied in this paper by the finite element method (FEM). The results show: (a) The maximum slip induced by the buried fault is not located at upper tip of the fault, but below it. (b) The vertical displacement changes remarkably near the fault, forming a fault scarp. With the increase of the soil layer thickness, the height of the scarp is decreased for the same earthquake magnitude. (c) The strong strain zone on the surface is localized near the projection of the fault tip on the ground surface. The horizontal strains in the zone are in tension above the hanging wall and in compression above the foot wall, and the vertical strains in the zone are vice versa, which is favorable for tensile- shear, compression-shear fissures above hanging wall and foot wall, respectively. 展开更多
关键词 listric thrust fault EARTHQUAKE fault scarps ground fissures finite element method (FEM)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部