期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
GuardWire Plus远端保护下急性心肌梗死的经皮冠状动脉介入治疗 被引量:2
1
作者 E.Grube F.W.Amann +1 位作者 S.Klugmann 申珂 《中国介入心脏病学杂志》 2003年第4期224-224,共1页
关键词 guardwire Plus远端保护 急性心肌梗死 经皮冠状动脉介入治疗 心肌灌注
下载PDF
PercuSurge GuardWire Plus远端球囊保护系统在介入治疗中的应用
2
作者 申珂 《中国介入心脏病学杂志》 2004年第2期117-117,共1页
关键词 PercuSurge guardwire Plus远端球囊保护系统 介入治疗 心肌梗死 适应证
下载PDF
在经皮介入隐静脉-主动脉冠状旁路桥(SVG)的过程中对Guard Wire远端防血栓装置进行随机试验
3
作者 申珂 《中国介入心脏病学杂志》 2002年第4期222-222,共1页
关键词 隐静脉桥血管成形术 经皮介入隐静脉-主动脉冠状旁路桥 guardwire 远端防血栓装置
下载PDF
利用远端保护装置对主动脉-冠状动脉的隐静脉桥病变实施经皮介入手术的6个月预后:FIRE试验结果
4
作者 Halkin A. Masud A.Z. +2 位作者 Rogers C. G.W.Stone 罗亮 《世界核心医学期刊文摘(心脏病学分册)》 2006年第9期18-19,共2页
Background: The filter-based FilterWire EX(Boston Scientific, Natick, MA) embolic protection system and the GuardWire(Medtronic, Santa Rosa, CA) balloon occlusion and aspiration device have been previously shown to re... Background: The filter-based FilterWire EX(Boston Scientific, Natick, MA) embolic protection system and the GuardWire(Medtronic, Santa Rosa, CA) balloon occlusion and aspiration device have been previously shown to reduce periprocedural complication rates of percutaneous coronary intervention for saphenous vein graft(SVG) disease and are considered the standard of care in this setting. The lateclinical course after treatment with these devices has not been reported. Methods: In the FIRE trial, 651 patients undergoing SVG intervention were randomized to either the FilterWire EX or GuardWire. Six-month rates of the primary end point(composite major adverse cardiac events[MACE]) and its components(death, myocardial infarction[MI], or target vessel revascularization)were studied. Results: MACE at 30 days occurred in 9.9%of patients randomized to the FilterWire EX compared with 11.6%with the GuardWire, P=.53. By 6 months, MACE had increased to 19.3%and 21.9%in FilterWire EX and GuardWire groups, respectively,(relative risk 0.88, 95%CI 0.65-1.19; P=.44). All-cause 6-month mortality in the entire population was 3.5%(3.0%with FilterWire EX vs 4.1%with GuardWire, P=.53, with all deaths occurring after hospital discharge). MI occurred in 12.0%of patients at 6 months(12.1%vs 11.9%with the FilterWire EX and GuardWire, respectively, P=.99), and target vessel revascularization was required in 9.1%(8.2%vs 10.0%, respectively, P=.42). Conclusions: SVG intervention with the FilterWire EX and GuardWire distal protection devices resulted in similar outcomes at 6 months, although the clinical course after hospital discharge was not benign, with significant rates of death, MI, and repeat intervention. 展开更多
关键词 经皮冠状动脉介入术 远端保护装置 经皮介入手术 静脉桥病变 E试验 FIR guardwire 主动脉
下载PDF
远端血管保护装置Guard Wire在急性心肌梗死急诊介入治疗中的应用 被引量:14
5
作者 黄铮 陈红武 +1 位作者 Osamu Katoh Shigeru Nakamura 《中华心血管病杂志》 CAS CSCD 北大核心 2003年第11期830-833,共4页
目的 评价GuardWire在急性心肌梗死 (AMI)急诊介入治疗时应用的价值。方法 连续观察 4 8例AMI急诊介入治疗并应用了GuardWire的患者 ,记录术中心电图变化及血流情况等 ,分析该装置的操作、造影和手术成功率 ,以及住院期间和术后 30d... 目的 评价GuardWire在急性心肌梗死 (AMI)急诊介入治疗时应用的价值。方法 连续观察 4 8例AMI急诊介入治疗并应用了GuardWire的患者 ,记录术中心电图变化及血流情况等 ,分析该装置的操作、造影和手术成功率 ,以及住院期间和术后 30d内的心血管事件发生率。结果 操作成功率、造影成功率和手术成功率均为 10 0 %。远端球囊阻塞时间平均 (8 1± 6 8)min ,所有患者均能良好耐受。 93 8%的患者吸引出肉眼可见的血栓 /斑块碎片 ,术中未出现因远端血管阻塞而引起的血液动力学或心电图、症状变化 ,未出现远端血管栓塞或无血流现象。住院期间和术后 30d内的心血管事件发生率均为 0。结论 该装置容易操作 ,可安全地应用于冠状动脉系统 ,有效防止AMI急诊介入治疗中可能出现的远端血管栓塞。 展开更多
关键词 远端血管保护装置 guardwire 急性心肌梗死 急诊 介入治疗 经皮冠状动脉血管成形术
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部