In recent years,there is a scenario in urban tunnel constructions to build super-large-span tunnels for traffic diversion and route optimization purposes.However,the increased size makes tunnel support more difficult....In recent years,there is a scenario in urban tunnel constructions to build super-large-span tunnels for traffic diversion and route optimization purposes.However,the increased size makes tunnel support more difficult.Unfortunately,there are few studies on the failure and support mechanism of the surrounding rocks in the excavation of supported tunnel,while most model tests of super-large-span tunnels focus on the failure characteristics of surrounding rocks in tunnel excavation without supports.Based on excavation compensation method(ECM),model tests of a super-large-span tunnel excavation by different anchor cable support methods in the initial support stage were carried out.The results indicate that during excavation of super-large-span tunnel,the stress and displacement of the shallow surrounding rocks decrease,following a step-shape pattern,and the tunnel failure is mainly concentrated on the vault and spandrel areas.Compared with conventional anchor cable supports,the NPR(negative Poisson’s ratio)anchor cable support is more suitable for the initial support stage of the super-large-span tunnels.The tunnel support theory,model test materials,methods,and the results obtained in this study could provide references for study of similar super-large-span tunnels。展开更多
Huaihe River Basin(HRB) is located in China’s north-south climatic transition zone,which is very sensitive to global climate change.Based on the daily maximum temperature,minimum temperature,and precipitation data of...Huaihe River Basin(HRB) is located in China’s north-south climatic transition zone,which is very sensitive to global climate change.Based on the daily maximum temperature,minimum temperature,and precipitation data of 40 meteorological stations and nine monthly large-scale ocean-atmospheric circulation indices data during 1959–2019,we present an assessment of the spatial and temporal variations of extreme temperature and precipitation events in the HRB using nine extreme climate indices,and analyze the teleconnection relationship between extreme climate indices and large-scale ocean-atmospheric circulation indices.The results show that warm extreme indices show a significant(P < 0.05) increasing trend,while cold extreme indices(except for cold spell duration) and diurnal temperature range(DTR) show a significant decreasing trend.Furthermore,all extreme temperature indices show significant mutations during 1959-2019.Spatially,a stronger warming trend occurs in eastern HRB than western HRB,while maximum 5-d precipitation(Rx5day) and rainstorm days(R25) show an increasing trend in the southern,central,and northwestern regions of HRB.Arctic oscillation(AO),Atlantic multidecadal oscillation(AMO),and East Atlantic/Western Russia(EA/WR) have a stronger correlation with extreme climate indices compared to other circulation indices.AO and AMO(EA/WR) exhibit a significant(P < 0.05) negative(positive)correlation with frost days and diurnal temperature range.Extreme warm events are strongly correlated with the variability of AMO and EA/WR in most parts of HRB,while extreme cold events are closely related to the variability of AO and AMO in eastern HRB.In contrast,AMO,AO,and EA/WR show limited impacts on extreme precipitation events in most parts of HRB.展开更多
In this paper,by choosing some appropriate test functions,we prove the Weyl’s lemma for triharmonic functions based on the new type of mean value formulas.
To make oral test accurately reflect the actual English spoken ability of candidates and play its role in guiding and promoting the improvement of English learners in the teaching, we must ensure that the design of sc...To make oral test accurately reflect the actual English spoken ability of candidates and play its role in guiding and promoting the improvement of English learners in the teaching, we must ensure that the design of scientific questions, the feasibility and validity of judgments to make an accurate and fair measurement of testers' language ability.展开更多
AIM:To study intestinal permeability(IP) and its relationship to the disease activity in patients with inflammatory bowel diseases(IBD)-Crohn's disease(CD) and ulcerative colitis(UC).METHODS:Fifty-eight patients w...AIM:To study intestinal permeability(IP) and its relationship to the disease activity in patients with inflammatory bowel diseases(IBD)-Crohn's disease(CD) and ulcerative colitis(UC).METHODS:Fifty-eight patients with active IBD(32 with CD and 26 with UC) and 25 healthy controls consented to participate in the study.The clinical activity of CD was estimated using the Crohn's Disease Activity Index(CDAI),and the endoscopic activity of UC using the Mayo scoring system.IP was assessed by the rise in levels of iohexol,which was administered orally(25 mL,350 mg/mL) 2 h after breakfast.Three and six hours later serum(SIC mg/L) and urine(UIC g/mol) iohexol concentrations were determined by a validated HPLC-UV technique.RESULTS:In the CD group,SIC values at 3 h(2.95 ± 2.11 mg/L) and at 6 h after ingestion(2.63 ± 2.18 mg/L) were significantly higher compared to those of healthy subjects(1.25 ± 1.40 mg/L and 1.11 ± 1.10 mg/L,respectively,P < 0.05).UIC(g/mol) values were also higher in patients,but the differences were significant only for UIC at 6 h.Significant positive correlation(P < 0.05) was found between the CDAI and IP,assessed by SIC at 3 h(r = 0.60) and 6 h(r = 0.74) after the ingestion.In comparison to controls,SIC and UIC of UC patients were higher in the two studied periods,but the differences were significant at 6 h only.Significantly higher values of SIC(P < 0.05) were found in patients with severe endoscopic activity of UC compared to those of patients with mild and moderate activity(3.68 ± 3.18 vs 0.92 ± 0.69 mg/L).CONCLUSION:Serum levels of iohexol at 3 h and 6 h after its ingestion reflect increased IP,which is related to the disease activity in patients with IBD.展开更多
AIM To assess the diagnostic accuracy of a new fecal test for detecting Helicobacter pylori(H. pylori), using ^(13)Curea breath test as the reference standard, and explore bacterial antibiotic resistance. METHODS We c...AIM To assess the diagnostic accuracy of a new fecal test for detecting Helicobacter pylori(H. pylori), using ^(13)Curea breath test as the reference standard, and explore bacterial antibiotic resistance. METHODS We conducted a prospective two-center diagnostic test accuracy study. We enrolled consecutive people≥ 18 years without previous diagnosis of H. pylori infection, referred for dyspepsia between February and October 2017. At enrollment, all participants underwent 13 C-urea breath test. Participants aged over 50 years were scheduled to undergo upper endoscopy with histology. Participants collected stool samples 1-3 d after enrollment for a new fecal investigation(THD fecal test). The detection of bacterial 23 S rRNA subunit gene indicated H. pylori infection. We also used the index diagnostic test to examine mutations conferring resistance to clarithromycin and levofloxacin. Independent investigators analyzed index test and reference test standard results blinded to the other test findings. We estimated sensitivity, specificity, positive(PPV) and negative(NPV) predictive value, diagnostic accuracy, positive and negative likelihood ratio(LR), together with 95% confidence intervals(CI).RESULTS We enrolled 294 consecutive participants(age: Median 37.0 years, IQR: 29.0-46.0 years; men: 39.8%). Ninetyfive(32.3%) participants had a positive ^(13)C-urea breath test. Twenty-three(7.8%) participants underwent upper endoscopy with histology, with a full concordance between ^(13)C-urea breath test and histology in detecting H. pylori infection. Four(1.4%) out of the 294 participants withdrew from the study after the enrollment visit and did not undergo THD fecal testing. In the 290 participants who completed the study, the THD fecal test sensitivity was 90.2%(CI: 84.2%-96.3%), specificity 98.5%(CI:96.8%-100%), PPV 96.5%(CI: 92.6%-100%), NPV 95.6%(CI: 92.8%-98.4%), accuracy 95.9%(CI: 93.6%-98.2%), positive LR 59.5(CI: 19.3-183.4), negative LR 0.10(CI: 0.05-0.18). Out of 83 infected participants identified with the THD fecal test, 34(41.0%) had bacterial genotypic changes consistent with antibiotic-resistant H. pylori infection. Of these, 27(32.5%) had bacterial strains resistant to clarithromycin, 3(3.6%) to levofloxacin, and 4(4.8%) to both antibiotics. CONCLUSION The THD fecal test has high performance for the non-invasive diagnosis of H. pylori infection while additionally enabling the assessment of bacterial antibiotic resistances.展开更多
Mechanical properties of structural materials are particularly important for design, performance realization and reliability analysis of microelectromechanical systems (MEMS). Furthermore, accurate database of mecha...Mechanical properties of structural materials are particularly important for design, performance realization and reliability analysis of microelectromechanical systems (MEMS). Furthermore, accurate database of mechanical properties at the micro scale can provide indispensable reference for establishing MEMS standard. Electroplated nickel film is one of the most favored structural materials used in MEMS, thus its mechanical properties has been studied for many years. However, the measured values show large scatter in Yotmg's modulus of nickel film. Young's modulus and yield stress of electroplated nickel film are measured by using a micro-tensile testing instrument. The tensile load applied on the specimen is measured by a load cell with accuracy 0.25 mN directly, without additional friction. Through measuring the axial stiffness coefficient of the tensile instnunent in situ, the tensile strain of the specimen is obtained by using two-serial spring model. The electroplated nickel films were fabricated from sulfarnate baths, and the gauge section is 500μm long and 10μm wide nominally, and thickness range between 25 μm and 50μm. The obtained Young's modulus from tensile testing is 83+6 GPa for nickel specimens electroplated at current density of 20 mA/cm2 and it increases to 124+5 GPa as current density is decreased to 10 mA/cm2. The phenomena are interpreted in terms of porosity of microstructure. The higher current density produced rnicrostucture with low density and high volume fraction of pores, and the microstructure of high porosity corresponds to a lower modulus. The measured values of Young's modulus are consistent with those of calculated from the exponential empirical formula between Young's modulus and porosity. The micro-tensile testing instrument can also be used for mechanical measurement of other MEMS films.展开更多
基金supported by the Innovation Fund Research Project of State Key Laboratory for Geomechanics and Deep Underground Engineering,China University of Mining and Technology(Grant No.SKLGDUEK202201)the Foundation for the Opening of State Key Laboratory for Geomechanics and Deep Underground Engineering,China University of Mining and Technology(Grant No.SKLGDUEK2129)the Open Research Fund of State Key Laboratory of Geomechanics and Geotechnical Engineering,Institute of Rock and Soil Mechanics,Chinese Academy of Sciences(Grant No.Z020007)。
文摘In recent years,there is a scenario in urban tunnel constructions to build super-large-span tunnels for traffic diversion and route optimization purposes.However,the increased size makes tunnel support more difficult.Unfortunately,there are few studies on the failure and support mechanism of the surrounding rocks in the excavation of supported tunnel,while most model tests of super-large-span tunnels focus on the failure characteristics of surrounding rocks in tunnel excavation without supports.Based on excavation compensation method(ECM),model tests of a super-large-span tunnel excavation by different anchor cable support methods in the initial support stage were carried out.The results indicate that during excavation of super-large-span tunnel,the stress and displacement of the shallow surrounding rocks decrease,following a step-shape pattern,and the tunnel failure is mainly concentrated on the vault and spandrel areas.Compared with conventional anchor cable supports,the NPR(negative Poisson’s ratio)anchor cable support is more suitable for the initial support stage of the super-large-span tunnels.The tunnel support theory,model test materials,methods,and the results obtained in this study could provide references for study of similar super-large-span tunnels。
基金Under the auspices of National Natural Science Foundation of China(No.52279016,51909106,51879108,42002247,41471160)Natural Science Foundation of Guangdong Province,China(No.2020A1515011038,2020A1515111054)+1 种基金Special Fund for Science and Technology Development in 2016 of Department of Science and Technology of Guangdong Province,China(No.2016A020223007)the Project of Jinan Science and Technology Bureau(No.2021GXRC070)。
文摘Huaihe River Basin(HRB) is located in China’s north-south climatic transition zone,which is very sensitive to global climate change.Based on the daily maximum temperature,minimum temperature,and precipitation data of 40 meteorological stations and nine monthly large-scale ocean-atmospheric circulation indices data during 1959–2019,we present an assessment of the spatial and temporal variations of extreme temperature and precipitation events in the HRB using nine extreme climate indices,and analyze the teleconnection relationship between extreme climate indices and large-scale ocean-atmospheric circulation indices.The results show that warm extreme indices show a significant(P < 0.05) increasing trend,while cold extreme indices(except for cold spell duration) and diurnal temperature range(DTR) show a significant decreasing trend.Furthermore,all extreme temperature indices show significant mutations during 1959-2019.Spatially,a stronger warming trend occurs in eastern HRB than western HRB,while maximum 5-d precipitation(Rx5day) and rainstorm days(R25) show an increasing trend in the southern,central,and northwestern regions of HRB.Arctic oscillation(AO),Atlantic multidecadal oscillation(AMO),and East Atlantic/Western Russia(EA/WR) have a stronger correlation with extreme climate indices compared to other circulation indices.AO and AMO(EA/WR) exhibit a significant(P < 0.05) negative(positive)correlation with frost days and diurnal temperature range.Extreme warm events are strongly correlated with the variability of AMO and EA/WR in most parts of HRB,while extreme cold events are closely related to the variability of AO and AMO in eastern HRB.In contrast,AMO,AO,and EA/WR show limited impacts on extreme precipitation events in most parts of HRB.
基金Supported by National Natural Science Foundation of China(Grant Nos.11801006 and 12071489).
文摘In this paper,by choosing some appropriate test functions,we prove the Weyl’s lemma for triharmonic functions based on the new type of mean value formulas.
文摘To make oral test accurately reflect the actual English spoken ability of candidates and play its role in guiding and promoting the improvement of English learners in the teaching, we must ensure that the design of scientific questions, the feasibility and validity of judgments to make an accurate and fair measurement of testers' language ability.
文摘AIM:To study intestinal permeability(IP) and its relationship to the disease activity in patients with inflammatory bowel diseases(IBD)-Crohn's disease(CD) and ulcerative colitis(UC).METHODS:Fifty-eight patients with active IBD(32 with CD and 26 with UC) and 25 healthy controls consented to participate in the study.The clinical activity of CD was estimated using the Crohn's Disease Activity Index(CDAI),and the endoscopic activity of UC using the Mayo scoring system.IP was assessed by the rise in levels of iohexol,which was administered orally(25 mL,350 mg/mL) 2 h after breakfast.Three and six hours later serum(SIC mg/L) and urine(UIC g/mol) iohexol concentrations were determined by a validated HPLC-UV technique.RESULTS:In the CD group,SIC values at 3 h(2.95 ± 2.11 mg/L) and at 6 h after ingestion(2.63 ± 2.18 mg/L) were significantly higher compared to those of healthy subjects(1.25 ± 1.40 mg/L and 1.11 ± 1.10 mg/L,respectively,P < 0.05).UIC(g/mol) values were also higher in patients,but the differences were significant only for UIC at 6 h.Significant positive correlation(P < 0.05) was found between the CDAI and IP,assessed by SIC at 3 h(r = 0.60) and 6 h(r = 0.74) after the ingestion.In comparison to controls,SIC and UIC of UC patients were higher in the two studied periods,but the differences were significant at 6 h only.Significantly higher values of SIC(P < 0.05) were found in patients with severe endoscopic activity of UC compared to those of patients with mild and moderate activity(3.68 ± 3.18 vs 0.92 ± 0.69 mg/L).CONCLUSION:Serum levels of iohexol at 3 h and 6 h after its ingestion reflect increased IP,which is related to the disease activity in patients with IBD.
文摘AIM To assess the diagnostic accuracy of a new fecal test for detecting Helicobacter pylori(H. pylori), using ^(13)Curea breath test as the reference standard, and explore bacterial antibiotic resistance. METHODS We conducted a prospective two-center diagnostic test accuracy study. We enrolled consecutive people≥ 18 years without previous diagnosis of H. pylori infection, referred for dyspepsia between February and October 2017. At enrollment, all participants underwent 13 C-urea breath test. Participants aged over 50 years were scheduled to undergo upper endoscopy with histology. Participants collected stool samples 1-3 d after enrollment for a new fecal investigation(THD fecal test). The detection of bacterial 23 S rRNA subunit gene indicated H. pylori infection. We also used the index diagnostic test to examine mutations conferring resistance to clarithromycin and levofloxacin. Independent investigators analyzed index test and reference test standard results blinded to the other test findings. We estimated sensitivity, specificity, positive(PPV) and negative(NPV) predictive value, diagnostic accuracy, positive and negative likelihood ratio(LR), together with 95% confidence intervals(CI).RESULTS We enrolled 294 consecutive participants(age: Median 37.0 years, IQR: 29.0-46.0 years; men: 39.8%). Ninetyfive(32.3%) participants had a positive ^(13)C-urea breath test. Twenty-three(7.8%) participants underwent upper endoscopy with histology, with a full concordance between ^(13)C-urea breath test and histology in detecting H. pylori infection. Four(1.4%) out of the 294 participants withdrew from the study after the enrollment visit and did not undergo THD fecal testing. In the 290 participants who completed the study, the THD fecal test sensitivity was 90.2%(CI: 84.2%-96.3%), specificity 98.5%(CI:96.8%-100%), PPV 96.5%(CI: 92.6%-100%), NPV 95.6%(CI: 92.8%-98.4%), accuracy 95.9%(CI: 93.6%-98.2%), positive LR 59.5(CI: 19.3-183.4), negative LR 0.10(CI: 0.05-0.18). Out of 83 infected participants identified with the THD fecal test, 34(41.0%) had bacterial genotypic changes consistent with antibiotic-resistant H. pylori infection. Of these, 27(32.5%) had bacterial strains resistant to clarithromycin, 3(3.6%) to levofloxacin, and 4(4.8%) to both antibiotics. CONCLUSION The THD fecal test has high performance for the non-invasive diagnosis of H. pylori infection while additionally enabling the assessment of bacterial antibiotic resistances.
基金supported by National Natural Science Foundation of China (Grant No. 50535030)National Basic Research Program of China (973 Program, Grant No. 2006CB300407)
文摘Mechanical properties of structural materials are particularly important for design, performance realization and reliability analysis of microelectromechanical systems (MEMS). Furthermore, accurate database of mechanical properties at the micro scale can provide indispensable reference for establishing MEMS standard. Electroplated nickel film is one of the most favored structural materials used in MEMS, thus its mechanical properties has been studied for many years. However, the measured values show large scatter in Yotmg's modulus of nickel film. Young's modulus and yield stress of electroplated nickel film are measured by using a micro-tensile testing instrument. The tensile load applied on the specimen is measured by a load cell with accuracy 0.25 mN directly, without additional friction. Through measuring the axial stiffness coefficient of the tensile instnunent in situ, the tensile strain of the specimen is obtained by using two-serial spring model. The electroplated nickel films were fabricated from sulfarnate baths, and the gauge section is 500μm long and 10μm wide nominally, and thickness range between 25 μm and 50μm. The obtained Young's modulus from tensile testing is 83+6 GPa for nickel specimens electroplated at current density of 20 mA/cm2 and it increases to 124+5 GPa as current density is decreased to 10 mA/cm2. The phenomena are interpreted in terms of porosity of microstructure. The higher current density produced rnicrostucture with low density and high volume fraction of pores, and the microstructure of high porosity corresponds to a lower modulus. The measured values of Young's modulus are consistent with those of calculated from the exponential empirical formula between Young's modulus and porosity. The micro-tensile testing instrument can also be used for mechanical measurement of other MEMS films.