期刊文献+
共找到38篇文章
< 1 2 >
每页显示 20 50 100
Studies of Adsorption of Cadmium Ions by Biowaste Adsorbent from Aqueous Solutions with Ion-Selective Electrodes and ICP-OES
1
作者 Taha Fadlou Allah Kaltrina Jusuf +3 位作者 Ali A. Shohatee Liang Feng Louis Trombetta Enju Wang 《American Journal of Analytical Chemistry》 2023年第6期274-286,共13页
Using environment-friendly and low-cost biowaste adsorbents as toxic metal ion removal substrates from aqueous solutions has a great economic advantage. This work evaluated pumpkin and potato peel biowastes for the ad... Using environment-friendly and low-cost biowaste adsorbents as toxic metal ion removal substrates from aqueous solutions has a great economic advantage. This work evaluated pumpkin and potato peel biowastes for the adsorption of cadmium ions. The biowastes were treated with acid or base. Batch experiments were carried out by introducing a known concentration of metal ion solution into the biowaste sorbent at various pH levels. The pH and metal ion concentration was monitored with pH and cadmium ion-selective electrode continuously for two hours, and the final concentration for the metal ion after 24 hours was measured with the cadmium electrode and then confirmed with ICP-OES. L-type isotherms were obtained that fit to Freundlich model. Adsorption isotherms showed chemical adsorption and the kinetics following the second order model. Equilibrium adsorption capacity is higher than 29 mg/g at pH 5.6 when the initial concentration is 220 ppm. Dynamic cadmium adsorption capacity is 17 mg/g from aqueous solution when the feed solution is 220 ppm with pumpkin peel biowaste sorbent. The biowaste materials can be regenerated with acid washing. 展开更多
关键词 Cadmium Ion Biowaste Sorbent ion-selective electrode ICP-OES
下载PDF
Direct Determination of Potassium-Sodium Activity Ratio in Soil Suspension with Two Ion-Selective Electrodes 被引量:1
2
作者 LIHONG-YAN JIGUO-LIANG 《Pedosphere》 SCIE CAS CSCD 1991年第4期363-369,共7页
A K+-selective electrode and a Na+-selective electrode were used to construct a measuring cell without liquid-junction for the determination of the ion activity ratio of K+ to Na+ in soil suspensions. The measured cel... A K+-selective electrode and a Na+-selective electrode were used to construct a measuring cell without liquid-junction for the determination of the ion activity ratio of K+ to Na+ in soil suspensions. The measured cell potential was not affected by the total electrolyte concentration when the total cation concentration was 10-1-10-3 mol L-1 and the concentration ratio CK+ / CNa+. was 10:1 to 1:50. When the concentration ratios were equal to 1and the total electrolyte concentrations were 10-2 and 10-3 mol L-1, the ion activity ratio measurement would not be affected by pH in the pH range of 3.5 to 11.5 and 4.4 to 11 respectively. Ions other than H+ have no remarkable influence on the measurement. The ion activity ratio of K+ to Na+ measured directly in soil suspension agree well with those in centrifuged supernant solution. The relative deviation was within 4%. From the measured ion activity ratio, the difference of the bonding energies of K+ and Na+ ions was calculated. 展开更多
关键词 ion activity ratio ion-selective electrode potassium ion sodium ion
下载PDF
Preparation of CeO_2 Nanoparticles and Its Application to Ion-selective Electrodes Based on Acetyl Cellulose 被引量:1
3
作者 Jinzhang Gao Fei Guan +4 位作者 Yongjun Ma Wu Yang Jingwan Kang Hualing Deng Youli Qi 《Rare Metals》 SCIE EI CAS CSCD 2001年第4期217-221,共4页
CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted comple... CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted completely at lower temperature. The redox behavior and the crystallization process of the dried gel were studied by thermogravimetric analysis and infrared spectroscopy. The synthesized powders were characterized by X-ray powder diffraction and transmission electron microscopy. In addition, rare earth elements ion-selective electrodes based on acetyl cellulose were prepared using ultra fine cerium oxide powders. 展开更多
关键词 CeO2 nanoparticles sol-gel method ion-selective electrode acetyl cellulose
下载PDF
Construction and Application of a PVC Membrane Enoxacin Ion-selective Electrode Based on a Needle-shaped Inner Reference Electrode
4
作者 HUANG Chao-lun LI Rui-fen XIU Rong 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2003年第4期409-412,共4页
A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet o... A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia. 展开更多
关键词 Enoxacin PVC membrane-coated-wire electrode ion-selective electrode Content determination
下载PDF
Potentiometric Urea Biosensor Based on Ion-Selective Electrode by Different Immobilization Procedures
5
作者 Nien-Hsuan Chou Jung-Chuan Chou +1 位作者 Tai-Ping Sun Shen-Kan Hsiung 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期309-312,共4页
Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,alterin... Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,altering the measured potential.Therefore,the characteristics of the effect of other ions on ammonium ion-selective electrode-based urea biosensors are considered.Based on the experimental results,the urea biosensor based on entrapment had a high response voltage of around 189 mV and fast response time of around 16 sec.Moreover,selectivity of the urea biosensor in different interfering ions was considered to elucidate the characteristics of ammonium ion-selective electrode-based biosensors. 展开更多
关键词 enzyme immobilization ammonium ion-selective electrode interfering ions urea biosensors SELECTIVITY
下载PDF
STUDY OF CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEW NEUTRAL CARRIER
6
作者 Wei XU Bin GUO You Rong NIE Zai Fu HUANG Department of Environmental Science,Wuhan University,430072 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第2期179-180,共2页
A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coeffic... A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coefficents are -2.3 Li(+),-3.5 Na(+),-4.0 K(+),-3.7NH_4(+),-4.5 Mg(2+) and -4.4Zn(2+). 展开更多
关键词 ETH ION STUDY OF CALCIUM ion-selective electrode BASED ON A NEW NEUTRAL CARRIER PVC
下载PDF
A comparative study of four 20-membered N_2S_4-crown ethers as ionophores for polymeric membrane silver selective electrodes 被引量:4
7
作者 Zhang, Jun Yu, Shun Yang +2 位作者 Yin, Tan Ji Hu, Xue Feng Qin, Wei 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第4期464-467,共4页
Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effe... Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho... 展开更多
关键词 ion-selective electrodes SILVER IONOPHORE Azathiacrown ether
下载PDF
Ion Selective Electrode Array Analysis Using Variable Step-Size Generalized Simulated Annealing
8
作者 WANG Shi-hua, XIAO Dan and YU Ru-qin (Department of Chemistry and Chemical Engineering,Hunan Univ. ,Changsha,410082) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第4期296-302,共7页
A global optimum location algorithm called Variable Step-Size Generalized Simulated Annealing(VSGSA) was applied to treating the data obtained by using an array of ion-electrodes in solutions containing mixtures of Na... A global optimum location algorithm called Variable Step-Size Generalized Simulated Annealing(VSGSA) was applied to treating the data obtained by using an array of ion-electrodes in solutions containing mixtures of Na+, K+, Ca2+. Unlike traditional optimization algorithms such as simplex procedure, VSGSA can be used to determine the model parameters without any priori information about the analytical system under investigation and overcome the disadvantage of simplex method which might converge to local extrema depending on the starting positions. The algorithm was applied to po-tentiometric determination of ions in mixture solutions. 展开更多
关键词 CHEMOMETRICS Multivariate calibration Array of ion-selective electrodes Generalized simulated annealing
下载PDF
Binding mechanism of halide ions to bovine serum albumin and hemoglobin: investigated by ion selective-electrode
9
作者 Gongke Wang Wen Tang +2 位作者 Xiaoxiao Hao Changling Yan Yan Lu 《Journal of Biophysical Chemistry》 2011年第3期194-201,共8页
The binding mechanism of the interactions of halide ions (F–, Br– and I–) with bovine serum albumin (BSA) and hemoglobin (Hb) were studied at different temperatures, by using ion-selective electrodes. The experimen... The binding mechanism of the interactions of halide ions (F–, Br– and I–) with bovine serum albumin (BSA) and hemoglobin (Hb) were studied at different temperatures, by using ion-selective electrodes. The experimental data were treated according to Klotz equation, and the number of binding sites and the binding constants were determined. The results show that the binding sites of F– on protein molecules are more than those of Br– and I–. Additionally, the number of the binding sites for halide ions on protein molecules increases with increasing temperature. This study also indicates that the binding constants for the interactions of halide ions with proteins gradually decrease as the size of halide ions and temperature increases. These behaviors were reasonably interpreted with the structural and thermodynamic factors. The thermodynamic functions at different temperatures were calculated with thermodynamic equations, and the enthalpy change for the interactions were also determined by isothermal titration calorimetry (ITC) at 298.15 K, which indicate that the interactions of halide ions with proteins are mainly electrostatic interaction. 展开更多
关键词 Binding Mechanism Interaction ion-selective electrode BOVINE Serum ALBUMIN HEMOGLOBIN
下载PDF
Coulometric Response of H-Selective Solid-Contact Ion-Selective Electrodes and Its Application in Flexible Sensors+
10
作者 Tingting Han Tao Song +4 位作者 Shiyu Gan Dongxue Han Johan Bobacka Li Niu Ari lvaska 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2023年第2期207-213,共7页
The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulf... The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection. 展开更多
关键词 Solid-contact ion-selective electrodes Membranes Proton transfer Conducting materials Cyclic voltammetry Coulometric response Flexible sensors Electrochemical impedance spectrum
原文传递
Metal sulfide quantum dots-aggregated PAMAM dendrimer for cadmium ion-selective electrode-based immunoassay of alpha-fetoprotein 被引量:2
11
作者 Qunfang Li Jing Jin +1 位作者 Fangming Lou Dianping Tang 《Science China Chemistry》 SCIE EI CAS CSCD 2018年第6期750-756,共7页
An ion-selective electrode(ISE)-based immunoassay has been innovatively designed for the sensitive detection of liver cancer biomarker(alpha-fetoprotein,AFP),using metal sulfide quantum dot(QD)-based nano labels.Cd S ... An ion-selective electrode(ISE)-based immunoassay has been innovatively designed for the sensitive detection of liver cancer biomarker(alpha-fetoprotein,AFP),using metal sulfide quantum dot(QD)-based nano labels.Cd S QDs-aggregated PAMAM dendrimer(QD-DE)was first synthesized and functionalized with polyclonal rabbit anti-human AFP antibodies.Thereafter,a sandwich immunoreaction was implemented on monoclonal mouse anti-human AFP antibody-coated microplate by using antibody-functionalized QD-DE as the secondary antibody.Accompanying the immunocomplex,subsequent potentiometric detection of cadmium ion dissolved from the QD-DE under acidic condition was conducted on a portable cadmium ion-selective electrode(Cd-ISE).Results revealed that the electrode potential of the Cd-ISE increased with the increment of AFP concentration from 0.1 to 100 ng m L^(-1)at a detection limit(LOD)of 68 pg m L^(-1).The relative standard deviations(RSD)were below9.09%and 10.54%for the intra-and inter-assay,respectively.Additionally,six human serum specimens were determined on CdISE-based immunosensor by using commercial human AFP ELISA kit as the reference,and gave good relationship between two methods.Importantly,Cd-ISE-based immunoassay offers the promise for simple and cost-effective screening of disease-related biomarkers. 展开更多
关键词 potentiometric immunoassay metal sulfide quantum dot PAMAM dendrimer ALPHA-FETOPROTEIN ion-selective electrode cancer biomarker
原文传递
A novel Ce(Ⅳ)ion-selective polyvinyl chloride membrane electrode based on HDEHP and HEH/EHP 被引量:1
12
作者 何金桂 李勇 +3 位作者 薛向欣 茹红强 黄小卫 杨合 《Journal of Rare Earths》 SCIE EI CAS CSCD 2017年第9期934-940,共7页
A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such... A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such as membrane composition, internal solution, concentration of SO_4^(2–), and acidity in test solution. The best performance was obtained using the membrane with PVC:DBP:HDEHP:HEH/EHP:OA mass ratio of 75:175:5:5:5. The proposed electrode exhibited a Nernstian slope of 30.44 mV/decade for Ce(Ⅳ) ion over a linear concentration range of 1×10^(–5)–1×10^(–1) mol/L with the detection limit of 9.0×10^(-6) mol/L. The electrode showed stable response within the SO_4^(2–) concentration range of 0.1–1 mol/L and the acidity range of 0.25–1.2 mol/L H+. The proposed electrode showed high selectivity for Ce(Ⅳ) over a wide variety of interfering ions and a fast response time. It was used as an indicator in the potentiometric titration of Ce(Ⅳ) solution with H_2O_2 solution, and could also be used for the determination of Ce(Ⅳ) in real Ce(Ⅳ)-containing aqueous samples. 展开更多
关键词 Ce(Ⅳ) ion-selective electrode HDEHP HEH/EHP PVC membrane potential response rare earths
原文传递
Synthesis of a Tweezer-like Bis(phenylthiapropoxy)calix[4]-arene as a Cation/π Enhanced Sensor for Ion-Selective Electrodes
13
作者 孙浩 曾宪顺 +7 位作者 吕监泉 冷雪冰 陈企发 徐风波 李庆山 何锡文 张文勤 张正之 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第10期1109-1114,共6页
Two novel 25,27-dihydroxy-26,28-bis(3-phenylthiapropoxy)-calixarene (3) and 25,27-dihydroxy-26,28-bis(3-phenylthia-propoxy)-5,11,17,23-tetra-tert-butylcalixarene (4) were synthesized for the evaluation of their ion-... Two novel 25,27-dihydroxy-26,28-bis(3-phenylthiapropoxy)-calixarene (3) and 25,27-dihydroxy-26,28-bis(3-phenylthia-propoxy)-5,11,17,23-tetra-tert-butylcalixarene (4) were synthesized for the evaluation of their ion-selectivity in ion-selective electrodes (ISEs). ISEs based on 3 and 4 as neutral ionophores were prepared, and their selectivity coefficients for Ag + (lg K pot Ag,M) were investigated against other alkali metal, alkaline-earth metal, aluminum, thallium (I), lead and some transition metal ions using the separate solution method (SSM). These ISEs showed excellent Ag + selectivity over most of the interfering cations examined, except for Hg 2+ and Fe 2+ having relative smaller interference (lg K pot Ag,M≤-2.1). 展开更多
关键词 CALIXARENES synthesis silver selectivity ion-selective electrode
原文传递
Comparison of three measurement models of soil nitrate-nitrogen based on ion-selective electrodes
14
作者 Shangfeng Du Qi Pan +1 位作者 Yun Xu Shushu Cao 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第1期211-216,共6页
Ion-selective electrode(ISE)is a quick and low-cost method of soil nitrate nitrogen(N)detection.The measurement models of soil nitrate-N based on ISEs includes the linear regression model,multiple linear regression mo... Ion-selective electrode(ISE)is a quick and low-cost method of soil nitrate nitrogen(N)detection.The measurement models of soil nitrate-N based on ISEs includes the linear regression model,multiple linear regression model and BP neural network model,and so on.Three models were analyzed in theory,measurement experiments of validation samples and soil nitrate-N concentrations were carried out in this study,and the measurement accuracies of the three models were compared.The results showed that,in the measurement experiments of validation samples and soil nitrate-N concentrations,BP neural network model had the highest accuracy(the average relative errors between results of the BP neural network model and the reference values were 5.07%and 8.81%,respectively)among the three models,multiple linear regression model had the second highest accuracy(the average relative errors between results of the multiple linear regression model and the reference values were 7.70%and 10.51%,respectively),linear regression model couldn’t exclude the interference of chloride ions so that it had the lowest accuracy(the average relative errors between results of the linear regression model and the reference values were 11.16%and 12.28%,respectively)among the three models.The BP neural network model can effectively restrain the interference of chloride ions,and it has a high accuracy for the measurement of soil nitrate-N concentration,so that the BP neural network model can be used to measure soil nitrate-N concentration accurately. 展开更多
关键词 ion-selective electrode soil nitrate-nitrogen measurement model ACCURACY
原文传递
New All-solid-state Carbonate Ion-selective Electrode with Ag2CO3-BaCO3 as Sensitive Films
15
作者 ZHAO Yue HAN Chenhua +4 位作者 HUANG Yuanfeng QIN Wenli ZHANG Xiao KAN Yating YE Ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2016年第4期655-660,共6页
A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respe... A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respectively. This paper presented the detailed procedures of the construction of the electrode, the applications of the electrode in various experiments, and the corresponding chemical reaction principles involved. The fabricated electrode was characterized by means of scanning electron microscopy(SEM), energy dispersive spectrometer(EDS), and electrochemical analyses. The electrode exhibited stable linear responses to carbonate anions(10-5--10-1 mol/L) with average Slope of the curve being -26.56 mV per decade, and showed negligible responses to NO3, SO2-, and Sal- anions. The electrode was further used to measure the concentration of carbonate anions in boiler water. The measured concentration was lower than that determined via titration. Overall, the electrode exhibited the advantages of miniaturized size, robust construction, and compatibility with other equipment and thus could be ideally integrated into various sensor platforms to collect chemical data from industrial heat exchangers. 展开更多
关键词 Ag2CO3-BaCO3 ion-selective electrode Carbonate determination Heat exchange water
原文传递
pH Overpotential for Unveiling the pH Gradient Effect of H^(+)/OH^(−)Transport in Electrode Reaction Kinetics
16
作者 Fengjun Yin Ling Fang Hong Liu 《CCS Chemistry》 CAS 2022年第1期369-380,共12页
The pH gradient caused by H^(+)/OH^(−)transport on an electrode surface is the key factor determining reaction performance,but its detailed impact on the electrode reaction kinetics has yet to be clarified.Here,the pH... The pH gradient caused by H^(+)/OH^(−)transport on an electrode surface is the key factor determining reaction performance,but its detailed impact on the electrode reaction kinetics has yet to be clarified.Here,the pH gradient effect was determined by developing electrode reaction equations,considering the overpotential assigned to the pH gradient called pH overpotential.The pH gradient effect was revealed to involve two aspects:(1)the Nernst pH overpotential,accounting for the common Nernst relationship with pH,and(2)the pH-dependent function of the electron-transfer coefficient(α_(pH)).Both parts were verified experimentally using oxygen reduction reaction and hydrogen evolution reaction,obviously,with differentα_(pH) functions.Detailedα_(pH) function effect was clarified based on numerical calculations of the electrode reaction equations.We found that the effect could be assessed suitably by an apparent constant(α_(app))and a nonlinear fitting method proposed forα_(app) value estimation.The results of this study provide the kinetic fundamentals of electrode reactions involving H^(+)/OH^(−)and contribute to the understanding and assessment of their performance with the H^(+)/OH^(−)transport effect. 展开更多
关键词 pH overpotential pH gradient effect electrode reaction kinetics H^(+)and OH^(−)transport hydrogen evolution reaction oxygen reduction reaction
原文传递
Adsorption of Potassium and Calcium Ions by Variable Charge Soils 被引量:2
17
作者 LIHONG-YAN JIGUO-LIANG 《Pedosphere》 SCIE CAS CSCD 1992年第3期255-264,共10页
Interactions of potassium and calcium ions with four typical variable charge soils in South China were examined by measuring pK-0.5pCa value with a potassium ion-selective electrode and a calcium ion-selective electro... Interactions of potassium and calcium ions with four typical variable charge soils in South China were examined by measuring pK-0.5pCa value with a potassium ion-selective electrode and a calcium ion-selective electrode,and pK value with a potassium ion-selective electrode.The results showed that adsorption of potassium and calcium ions increased with soil suspension pH,and the tendency of the pK-0.5pCa value changing with pH differed with respect to pH range and potassium to calcium ratio.Adsorption of equal amount of calcium and potassium ions led to release of an identical number of protons,suggesting similar adsorption characteristics of these two ions when adsorbed by variable charge soils.Compared with red soil,latosol and lateritic red soil had higher adsorption selectivities for calcium ion.The red soil had a greater affinity for potassium ion than that for calcium ion at low concentration,which seems to result from its possession of 2:1 type minerals,such as vermiculite and mica with a high affinity for potassium ion.The results indicated that adsorption of potassium and calcium ions by the variable charge soils was chiefly caused by the electrostatic attraction between the cations and the soil surfaces.Moreover,it was found that sulfate could affect the adsorption by changing soil surface properties and by forming ion-pair. 展开更多
关键词 ADSORPTION calcium ion ion-selective electrode potassium ion variable charge soil
下载PDF
Potentiometric detection of polyions based on functionalized magnetic nanopaiticles 被引量:2
18
作者 De An Song Rong Ning Liang +3 位作者 Rui Ming Zhang Jia Wang Ding Jun Zhang Wei Qin 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第11期1378-1381,共4页
A novel potentiometric detection strategy based on functionalized magnetic nanoparticles has been developed for rapid and sensitive sensing of polyions.Highly dispersed magnetic nanoparticles coated with ion exchanger... A novel potentiometric detection strategy based on functionalized magnetic nanoparticles has been developed for rapid and sensitive sensing of polyions.Highly dispersed magnetic nanoparticles coated with ion exchanger and plasticizer could promote an in situ cooperative ion-pairing interaction between the ion exchanger and the polyion analyte in sample solution by dramatically reducing the mass-transfer distance.With applying a magnetic field,the nanoparticles can be attached to the surface of ion exchanger free polymeric membrane.The observed potential signals are related to the polyion concentrations.The proposed polymeric membrane electrode exhibits a linear relationship between the greatest potential response slope(dE/dt) and the logarithm of protamine concentration in the range of 0.05-5μg/mL with a lower detection limit of 0.033μg/mL. 展开更多
关键词 POTENTIOMETRY Functionalized magnetic nanoparticles POLYIONS ion-selective electrodes
下载PDF
Adsorption Kinetics of Pb^(2+) and Cu^(2+) on Variable Charge Soils and Minerals: Ⅲ. Adsorption Kinetics of Pb^(2+) Within 30 Minutes 被引量:2
19
作者 HUGUO-SONG YUMING-FENG 《Pedosphere》 SCIE CAS CSCD 1993年第4期349-359,共11页
The adsorption kinetics of Pb^2+ on different soils and minerals with variable charges was studied by the two ion-selective electrode technique at different pH and concentrations.The results showed that more than 95% ... The adsorption kinetics of Pb^2+ on different soils and minerals with variable charges was studied by the two ion-selective electrode technique at different pH and concentrations.The results showed that more than 95% of adsorption on all the samples occurred during the first 5 minutes.All adsorption time-dependent data could fit the surface second-order equation very well.The values of Xm were goethite>kaolinite,and latosol>red soil at the same initial reaction concentration.The values of k were kaolinite>>goethite,and latosol>red soil at the same reaction pH and initial concentration.The higher the suspension pH,the faster the adsorption occurred.The meaning of Xm got by the two ion-selective electrode technique(one kind of batch technique) was different from that by the miscible displacement technique in that the former was only the equilibrium adsorption amount at a definite concentration and pH,but the latter was almost equal to the adsorption capacity at a definite pH with much less influence of concentration.One Pb^2+ was supposed to occupy two adsorption sites as the adsorption mechanism is concerned. 展开更多
关键词 ADSORPTION KINETICS PB2+ two ion-selective electrode technique variable charge surfaces
下载PDF
Kinetic Characteristics of Nitrate Uptake by Wheat and Rape and Their Determination 被引量:2
20
作者 ZHANGLI-GAN XUANJIA-XIANG 《Pedosphere》 SCIE CAS CSCD 1993年第2期127-132,共6页
15-day old seedlings of wheat and rape were grown in a series of solutions with different concentrations of KNO3 for a definite period of time. The changes in NO3- concentration of the solutions were determined by the... 15-day old seedlings of wheat and rape were grown in a series of solutions with different concentrations of KNO3 for a definite period of time. The changes in NO3- concentration of the solutions were determined by the double ion-selective electrode method, and then the amount of NO3- taken up by the plants was estimated and values of Km and Imax of the Michealis-Menten equation were calculated. Results show that both the method and conditions of determination affected the values of Km and Imax. For example, the Km value was appreciably reduced when the volume of culture solution was increased or when the duration of nutrient uptake was shortened; the Km value obtained with short-term depletion method was higher than that obtained with long-term one. Similar Variations were found for the values of Imax. There was a considerable difference in the characteristics of uptake kinetics between wheat and rape when determined under the same conditions of determination. The isotherm of NO3- uptake by wheat could be separated into saturated and unsaturated parts, and when the concentration of NO3- exceeded 180 uuuuuuuuuuuuM, the relationship between the rate of NO3- uptake and NO3- concentration tended to be linear. However, the isotherm of NO3- uptake by rape was found to fit the Michealis-Menten equation and no linear relationship could be found. 展开更多
关键词 double ion-selective electrode method kinetic parameter NITRATE
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部