Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us...Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections.展开更多
A series of H-shaped (PS)2PEG(PS)2 block copolymers with different PS chain lengths were prepared. The influence of different confinements active on the crystallization and self-nucleation (SN) behavior of the P...A series of H-shaped (PS)2PEG(PS)2 block copolymers with different PS chain lengths were prepared. The influence of different confinements active on the crystallization and self-nucleation (SN) behavior of the PEG blocks was investigated by differential scanning calorimetry (DSC). When the content of the crystalline block was high, a classical SN behavior was obtained. The block copolymer with PEG content of 49% (by weight) showed a classical SN behavior with a narrow self-nucleation domain and had bimodal crystallization exotherms. When the PEG dispersed as separated microdomains in the block copolymer, the self-nucleation domain disappeared and only annealing was observed.展开更多
304L H-shaped stainless steel is used as the support frame of the passive residual heat removal heat exchanger(PRHR HX) in a nuclear fission reactor. The extrusion process is adopted to manufacture the 304L H-shaped s...304L H-shaped stainless steel is used as the support frame of the passive residual heat removal heat exchanger(PRHR HX) in a nuclear fission reactor. The extrusion process is adopted to manufacture the 304L H-shaped stainless steel. Finite element method simulation is herein used to analyze metal flow characteristics, optimize the extrusion die, and predict the extrusion force at different temperatures and speeds. A Φ400-mm container and Φ388-mm forging billet are selected, and the 304L H-shaped stainless steel is successfully manufactured using a Germany SMS 60 MN horizontal extruder. The mechanical properties and microstructure of the manufactured 304L H-shaped stainless steel meet the requirements of the PRHR HX, and the surfaces of the product pass the dye penetration test. The H-shaped stainless steels are used in Haiyang nuclear power plant in Shandong Province.展开更多
This study simulates natural convection flow resulting from heat partitions in an H-shaped enclosure filled with a nanofluid using an incompressible smoothed particle hydrodynamics(ISPH)method.The right area of the H-...This study simulates natural convection flow resulting from heat partitions in an H-shaped enclosure filled with a nanofluid using an incompressible smoothed particle hydrodynamics(ISPH)method.The right area of the H-shaped enclosure is saturated with non-Darcy porous media.The center variable partitions of the H-shaped enclosure walls are kept at a high-temperature Th.The left and right walls of the H-shaped enclosure are positioned at a low temperature Tc and the other walls are adiabatic.In ISPH method,the source term in pressure Poisson equation(PPE)is modified.The influences of the controlling parameters on the temperature distributions,the velocity field and average Nusselt number are discussed.The performed simulations proofed that the length of the heated partitions augments the velocity field and temperature distributions in an H-shaped enclosure.Rayleigh number rises the fluid velocity and heat transfer in an H-shaped enclosure.The porous layer on the right side of the H-shaped enclosure at a lower Darcy parameter causes a high resistance force for the fluid flow and heat transfer characteristic inside an H-shaped enclosure.Added nanoparticles reduces the velocity field and enhances the heat transfer inside an H-shaped enclosure.展开更多
As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years...As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years.To fulfill this special requirement imposed by current seismic design codes,reinforcement ratios in the bridge towers have to be kept significantly higher than if limited ductility behavior of the tower is allowed.In addition,since the foundation capacity is closely related to the moment and shear capacities of the bridge tower,a large increase in bridge construction cost for elastically designed cable-stayed bridge is inevitable.To further investigate the possibility of limited ductility bridge tower design strategies,a new 1/20-scale cable-stayed bridge model with H-shaped bridge towers designed according to strong strut-weak tower column design was tested.The shake table experimental results are compared with a previous strong tower column-weak strut designed full bridge model.A comparison of the results show that ductility design with plastic hinges located on tower columns,i.e.,strong strut-weak tower column design,is another effective seismic design strategy that results in only small residual displacement at the top of the tower column,even under very severe earthquake excitations.展开更多
Conventional slot microstrip antenna is analyzed,an h-shaped multi-frequency and miniaturization slot microstrip antenna is proposed.Numerical simulation is performed for the characteristics of the antenna with the so...Conventional slot microstrip antenna is analyzed,an h-shaped multi-frequency and miniaturization slot microstrip antenna is proposed.Numerical simulation is performed for the characteristics of the antenna with the software HFSS11.0,which is a kind of simulation software based on Finite Element Method,the simulation results shown that the antenna operated at 2.26~2.42GHz,2.67~2.82GHz,4.28~4.39GHz and 5.76~5.89GHz when the return loss S11<-10dB,the size reduced compare to general microstrip antenna,demonstrated the effectiveness of the design scheme.The antenna structure is simple and easily to be implemented,met the wireless LAN 802.11a/b/g/n mobile terminal antenna miniaturization and multi-band requirements.展开更多
Despite the fact that some progress has been made in the self-assembly of H-shaped polymers, the corresponding self-assemblies that respond to external stimulus and are further utilized to adjust the release of drugs ...Despite the fact that some progress has been made in the self-assembly of H-shaped polymers, the corresponding self-assemblies that respond to external stimulus and are further utilized to adjust the release of drugs are still deficient. The stimuli-responsive segments with amphiphilic H-shaped structure are generally expected to enhance the controllability of self-assembly process. The synthesis and self-assembly behavior of thermo-responsive amphiphilic H-shaped polymers with poly(ethylene glycol) (PEG), polytetrahydrofuran (PTHF) and poly(N-isopropyl acrylamide) (PNIPAM) as building blocks are reported in this paper. The inner architecture structure and size of complex micelles formed by H-shaped self-assemblies were effectively adjusted when the solution temperature was increased above the lower critical solution temperature of PNIPAM segments. Furthermore, it was found that the architecture of self-assemblies underwent a transition from the complex micelles based on primary micelles with hybrid PEG/PNIPAM shells to large complex micelles based on primary micelles with hybrid PTHF/PNIPAM cores and PEG shells during the thermal-induced self-assembly process. The adjustable release rate ofdoxorubicin (DOX) from the DOX-loaded complex micelles and basic cell experiments further proved the feasibility of these self-assemblies as the thermal-responsive drug delivery system.展开更多
基金Supported by National Natural Science Foundation of China(No.51268054)Natural Science Foundation of Tianjin(No.13JCQNJC07300)the foundation of Key Laboratory of Coast Civil Structure Safety(Tianjin University),Ministry of Education of China(No.2011-1)
文摘Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections.
基金supported by the National Natural Science Foundation of China(No.50503022)Programs and the Fund for Creative Research Groups(No.50621302)
文摘A series of H-shaped (PS)2PEG(PS)2 block copolymers with different PS chain lengths were prepared. The influence of different confinements active on the crystallization and self-nucleation (SN) behavior of the PEG blocks was investigated by differential scanning calorimetry (DSC). When the content of the crystalline block was high, a classical SN behavior was obtained. The block copolymer with PEG content of 49% (by weight) showed a classical SN behavior with a narrow self-nucleation domain and had bimodal crystallization exotherms. When the PEG dispersed as separated microdomains in the block copolymer, the self-nucleation domain disappeared and only annealing was observed.
基金supported by the State Key Laboratory for Mechanical Behavior of Materials(No.20171909)
文摘304L H-shaped stainless steel is used as the support frame of the passive residual heat removal heat exchanger(PRHR HX) in a nuclear fission reactor. The extrusion process is adopted to manufacture the 304L H-shaped stainless steel. Finite element method simulation is herein used to analyze metal flow characteristics, optimize the extrusion die, and predict the extrusion force at different temperatures and speeds. A Φ400-mm container and Φ388-mm forging billet are selected, and the 304L H-shaped stainless steel is successfully manufactured using a Germany SMS 60 MN horizontal extruder. The mechanical properties and microstructure of the manufactured 304L H-shaped stainless steel meet the requirements of the PRHR HX, and the surfaces of the product pass the dye penetration test. The H-shaped stainless steels are used in Haiyang nuclear power plant in Shandong Province.
基金The authors would like to extend their appreciations to the Deanship of Scientific Research at King Khalid University,Abha,Saudi Arabia,for funding this work through the Research Group Project under Grant Number(R.G.P 2/70/41).
文摘This study simulates natural convection flow resulting from heat partitions in an H-shaped enclosure filled with a nanofluid using an incompressible smoothed particle hydrodynamics(ISPH)method.The right area of the H-shaped enclosure is saturated with non-Darcy porous media.The center variable partitions of the H-shaped enclosure walls are kept at a high-temperature Th.The left and right walls of the H-shaped enclosure are positioned at a low temperature Tc and the other walls are adiabatic.In ISPH method,the source term in pressure Poisson equation(PPE)is modified.The influences of the controlling parameters on the temperature distributions,the velocity field and average Nusselt number are discussed.The performed simulations proofed that the length of the heated partitions augments the velocity field and temperature distributions in an H-shaped enclosure.Rayleigh number rises the fluid velocity and heat transfer in an H-shaped enclosure.The porous layer on the right side of the H-shaped enclosure at a lower Darcy parameter causes a high resistance force for the fluid flow and heat transfer characteristic inside an H-shaped enclosure.Added nanoparticles reduces the velocity field and enhances the heat transfer inside an H-shaped enclosure.
基金National Key Research and Development Plan,China under Grant No.2017YFC1500702the National Natural Science Foundation of China under Grant No.51478338。
文摘As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years.To fulfill this special requirement imposed by current seismic design codes,reinforcement ratios in the bridge towers have to be kept significantly higher than if limited ductility behavior of the tower is allowed.In addition,since the foundation capacity is closely related to the moment and shear capacities of the bridge tower,a large increase in bridge construction cost for elastically designed cable-stayed bridge is inevitable.To further investigate the possibility of limited ductility bridge tower design strategies,a new 1/20-scale cable-stayed bridge model with H-shaped bridge towers designed according to strong strut-weak tower column design was tested.The shake table experimental results are compared with a previous strong tower column-weak strut designed full bridge model.A comparison of the results show that ductility design with plastic hinges located on tower columns,i.e.,strong strut-weak tower column design,is another effective seismic design strategy that results in only small residual displacement at the top of the tower column,even under very severe earthquake excitations.
基金supported by the Science Technology of The Chongqing Education Commission(KJ100512)the Natural Science Foundation of Chongqing province of China(CSTC 2010BB2412)
文摘Conventional slot microstrip antenna is analyzed,an h-shaped multi-frequency and miniaturization slot microstrip antenna is proposed.Numerical simulation is performed for the characteristics of the antenna with the software HFSS11.0,which is a kind of simulation software based on Finite Element Method,the simulation results shown that the antenna operated at 2.26~2.42GHz,2.67~2.82GHz,4.28~4.39GHz and 5.76~5.89GHz when the return loss S11<-10dB,the size reduced compare to general microstrip antenna,demonstrated the effectiveness of the design scheme.The antenna structure is simple and easily to be implemented,met the wireless LAN 802.11a/b/g/n mobile terminal antenna miniaturization and multi-band requirements.
基金financially supported by the National Natural Science Foundation of China(No.21674086)Scientific Research Program Funded by Shaanxi Provincial Education Department(No.17JK0103)
文摘Despite the fact that some progress has been made in the self-assembly of H-shaped polymers, the corresponding self-assemblies that respond to external stimulus and are further utilized to adjust the release of drugs are still deficient. The stimuli-responsive segments with amphiphilic H-shaped structure are generally expected to enhance the controllability of self-assembly process. The synthesis and self-assembly behavior of thermo-responsive amphiphilic H-shaped polymers with poly(ethylene glycol) (PEG), polytetrahydrofuran (PTHF) and poly(N-isopropyl acrylamide) (PNIPAM) as building blocks are reported in this paper. The inner architecture structure and size of complex micelles formed by H-shaped self-assemblies were effectively adjusted when the solution temperature was increased above the lower critical solution temperature of PNIPAM segments. Furthermore, it was found that the architecture of self-assemblies underwent a transition from the complex micelles based on primary micelles with hybrid PEG/PNIPAM shells to large complex micelles based on primary micelles with hybrid PTHF/PNIPAM cores and PEG shells during the thermal-induced self-assembly process. The adjustable release rate ofdoxorubicin (DOX) from the DOX-loaded complex micelles and basic cell experiments further proved the feasibility of these self-assemblies as the thermal-responsive drug delivery system.