期刊文献+
共找到508篇文章
< 1 2 26 >
每页显示 20 50 100
Simultaneous Determination of Uranium and Thorium with Standard Dual-addition Method
1
作者 何荣桓 王建华 王玉宝 《Rare Metals》 SCIE EI CAS CSCD 1998年第2期75-80,共6页
dual-standard addition method was proposed and the principle of simultaneous determination for a interfering binary mixtures was discussed. The proposed procedure was applied to spectroscopic analyses for the simultan... dual-standard addition method was proposed and the principle of simultaneous determination for a interfering binary mixtures was discussed. The proposed procedure was applied to spectroscopic analyses for the simultaneous determination of uranium and thorium without prior separation. Various molar ratios of uranium/thorium, from 0.5∶1 to 10∶1, can be determined with satisfactory precision and accuracy. Uranium and thorium content in a phosphate ore and simulated sample were determined, the recoveries were 98.4%~102.5% for uranium and 96.8%~102.3% for thorium, the relative standard deviations (R.S.D) were 1.5%~2.3% for uranium and 2.1%~3.1% for thorium. 展开更多
关键词 Dual-standard addition method Simultaneous determination URANIUM THORIUM Spectroscopic analysis
下载PDF
H-point计算分光光度法研究及其在复方盐酸丁卡因注射液中的应用 被引量:3
2
作者 陈国广 相秉仁 安登魁 《中国药科大学学报》 CAS CSCD 北大核心 1999年第2期97-99,共3页
介绍几种H-point法,并与常见的计算分光光度法进行了比较。将H-point法用于复方盐酸丁卡因注射液测定的数据处理,表明H-point法有效地消除干扰,有较高的精密度和准确度。盐酸丁卡因回收率为:H-point法... 介绍几种H-point法,并与常见的计算分光光度法进行了比较。将H-point法用于复方盐酸丁卡因注射液测定的数据处理,表明H-point法有效地消除干扰,有较高的精密度和准确度。盐酸丁卡因回收率为:H-point法101.0%,RSD为2.7%(n=7),K系数H-point法99.1%,RSD为1.8%(n=7),三波长H-point法99.6%,RSD为1.4%(n=7)。 展开更多
关键词 计算分光光度法 盐酸丁卡因 麻醉药 含量测定
下载PDF
白色和灰色H-point法分析鲁南贝特片
3
作者 陈国广 张琪 +4 位作者 朱凤英 韦萍 邹巧根 张尊建 相秉仁 《南京工业大学学报(自然科学版)》 CAS 2002年第3期95-98,共4页
比较H point法在白色与灰色体系中的应用 ,考察其分析结果的可靠性。研究鲁南贝特片、氯唑沙宗、对乙酰氨基酚的紫外吸收光谱 ,优化纯组分区间 ,采用标准加入系列光谱数据 ,测定主要成分的含量 ,并与白色处理方法比较。得出了氯唑沙宗... 比较H point法在白色与灰色体系中的应用 ,考察其分析结果的可靠性。研究鲁南贝特片、氯唑沙宗、对乙酰氨基酚的紫外吸收光谱 ,优化纯组分区间 ,采用标准加入系列光谱数据 ,测定主要成分的含量 ,并与白色处理方法比较。得出了氯唑沙宗的回收率为 10 2 .9% ,RSD =2 .12 % (n =7) ,对乙酰氨基酚的回收率为 10 0 .5 % ,RSD =1.98% (n =7) ;样品的标示含量为氯唑沙宗 98.8% ,RSD =1.6 4 (n =3) ;对乙酰氨基酚 98.3% ,RSD=1.6 9(n =3)。结果表明此法适合于灰色体系的分析 。 展开更多
关键词 白色 鲁南贝特片 h-point 灰色体系 纯组分区间 氯唑沙宗 对乙酰氨基酚 解痉镇痛药
下载PDF
电感耦合等离子体质谱法测定复杂高温合金中微量硅
4
作者 王丹 李思思 +3 位作者 李辉 郭莉莉 郭宏杰 张重远 《化学分析计量》 CAS 2024年第2期77-81,共5页
以混酸低温加热方式溶解合金,采用电感耦合等离子体质谱法测定复杂高温合金中微量硅。通过实验前准备、动能歧视和完全匹配基体消除二次污染、多原子离子干扰和共存元素干扰。采用5 mL盐酸、0.5 mL硝酸和几滴氢氟酸作溶剂,于80℃加热溶... 以混酸低温加热方式溶解合金,采用电感耦合等离子体质谱法测定复杂高温合金中微量硅。通过实验前准备、动能歧视和完全匹配基体消除二次污染、多原子离子干扰和共存元素干扰。采用5 mL盐酸、0.5 mL硝酸和几滴氢氟酸作溶剂,于80℃加热溶解合金样品,以Sc为内标校正仪器波动产生的影响。以硅的信号强度值为纵坐标,其质量分数为横坐标,绘制标准工作曲线,质量分数在0.002%~0.10%范围内线性良好,相关系数为0.999,检出限为0.0003%。样品加标平均回收率为90.0%~110.0%,测定结果的相对标准偏差不大于2.0%(n=6)。该方法操作简便,能够满足日常测试要求。 展开更多
关键词 电感耦合等离子体质谱法 标准加入法 复杂高温合金 微量硅
下载PDF
培养基及其pH对饲用凝结芽孢杆菌制剂的菌数检测影响
5
作者 王雪艳 王乙茹 +5 位作者 苗华彪 陈德近 何雪 杨睿 安清聪 程志斌 《饲料工业》 CAS 北大核心 2024年第24期91-95,共5页
研究采用平板计数法,评估了两个团体标准(T/YNBX 024,简称云南团标;T/CSWSL 022,简称北京团标)中的检测培养基及其pH对饲用凝结芽孢杆菌制剂的菌数检测影响。结果显示:两个团体标准中的特异培养基均可用于饲用凝结芽孢杆菌的菌数检测。... 研究采用平板计数法,评估了两个团体标准(T/YNBX 024,简称云南团标;T/CSWSL 022,简称北京团标)中的检测培养基及其pH对饲用凝结芽孢杆菌制剂的菌数检测影响。结果显示:两个团体标准中的特异培养基均可用于饲用凝结芽孢杆菌的菌数检测。采用云南团标配制的检测培养基,培养基pH 4.9~5.5范围均可用于准确检测凝结芽孢杆菌的总菌数。然而,采用北京团标中的检测培养基,需将培养基pH调整为5.5。以上研究结果旨在为规范饲用凝结芽孢杆菌制剂的菌数检测方法提供科学依据。 展开更多
关键词 饲用凝结芽孢杆菌 菌数检测 培养基 平板计数法 团体标准
下载PDF
二氧化硅抛光液中金属杂质的检测方法
6
作者 郝萍 《上海计量测试》 2024年第4期11-13,17,共4页
采用高分辨电感耦合等离子质谱仪检测二氧化硅抛光液中金属杂质元素,通过调节元素分辨力,选择适合的同位素进行检测,可有效解决质谱干扰问题。采用标准加入法稀释样品检测金属杂质含量的方法,10μg/kg加标回收率为81.17%~111.79%,可以... 采用高分辨电感耦合等离子质谱仪检测二氧化硅抛光液中金属杂质元素,通过调节元素分辨力,选择适合的同位素进行检测,可有效解决质谱干扰问题。采用标准加入法稀释样品检测金属杂质含量的方法,10μg/kg加标回收率为81.17%~111.79%,可以实现对二氧化硅抛光液中多金属杂质的快速分析。 展开更多
关键词 高分辨电感耦合等离子体质谱仪 金属杂质 标准加入法 二氧化硅抛光液
下载PDF
高纯铟杂质元素的ICP-MS测试方法研究 被引量:1
7
作者 牛佳佳 刘朋超 +3 位作者 王文燕 李乾 赵超 折伟林 《红外》 CAS 2024年第3期23-28,共6页
红外材料锑化铟的原材料之一是高纯度铟,其杂质元素的种类和含量直接影响了探测器的性能。因此建立准确高效的痕量元素定量测试方法尤为重要。通过严格控制温度保证酸解过程的可实现性,使用标准加入法建立标准曲线并对样品进行测试。经... 红外材料锑化铟的原材料之一是高纯度铟,其杂质元素的种类和含量直接影响了探测器的性能。因此建立准确高效的痕量元素定量测试方法尤为重要。通过严格控制温度保证酸解过程的可实现性,使用标准加入法建立标准曲线并对样品进行测试。经过响应率对比,该项测试选取的基底样品为单标溶液In10000,标准曲线的线性相关系数均接近于0.999。排除线性差异的影响,对多批次的测试结果进行分析并验证其准确性。同时采用内标法验证In10000溶液内的多种杂质元素含量。结果表明,基底样品具有极低的杂质含量。通过配置已知标准浓度的溶液对该测试方法的准确性和可重复性进行多次验证。测试结果表明,该项测试方法准确有效,可应用于高纯(大于6N) In的杂质含量测试。 展开更多
关键词 ICP-MS 高纯In 痕量元素 标准加入法
下载PDF
KED碰撞模式-电感耦合等离子体质谱(ICP-MS)法测定血液、尿液中8种重金属和准金属元素 被引量:2
8
作者 吴泽清 张成龙 +4 位作者 国菲 刘番番 毕文姬 杨瑞琴 李鹏 《中国无机分析化学》 CAS 北大核心 2024年第4期393-400,共8页
在金属中毒与死亡案件中,实验室常用的标准曲线法对人体内重金属和准金属元素定量分析的准确性易受不同人群血液、尿液基质差异以及基质效应的影响,为此建立了直接稀释-电感耦合等离子体质谱结合标准加入法测定人体血液和尿液中Cr、Co... 在金属中毒与死亡案件中,实验室常用的标准曲线法对人体内重金属和准金属元素定量分析的准确性易受不同人群血液、尿液基质差异以及基质效应的影响,为此建立了直接稀释-电感耦合等离子体质谱结合标准加入法测定人体血液和尿液中Cr、Co、Ni、As、Cd、Sb、Pb、Tl等8种重金属和准金属元素含量的方法。优化了碰撞气流量和载气流速,提高了对8种目标元素定性定量的灵敏度;探究了不同体积分数下ICP-MS增敏剂Triton X-100和乙醇对元素响应值的影响,采用0.1%HNO 3-0.05%Triton X-100混合溶液作为血液稀释剂稀释检材50倍,0.1%HNO 3-1%乙醇混合溶液作为尿液稀释剂稀释检材10倍,提高样品溶液中元素的响应值的同时避免了未消解有机物对仪器信号的影响。标准加入法的应用避免引入其他空白样品定量目标元素,保持定量过程中基质的一致性从而克服了样品中的基质效应,采用动能歧视(KED)模式对直接稀释后的目标元素进行测定,干扰离子与He碰撞裂解有效降低了多原子离子干扰,并选择60 s的清洗时间降低了元素的记忆效应。结果表明,各元素检出限(LOD)为0.006~0.063μg/L,定量限(LOQ)为0.02~0.21μg/L,血液和尿液中的加标回收率为78.8%~118%,日内和日间精密度均小于8.7%。建立的方法快速准确、灵敏度高、操作安全,方法及相关数据可以为相关案件中血液、尿液检材中重金属和准金属元素的检验鉴定提供方法参考和数据支撑。 展开更多
关键词 电感耦合等离子体质谱法 标准加入法 重金属 准金属 血液 尿液
下载PDF
电感耦合等离子体质谱(ICP-MS)法同时测定水系沉积物中痕量铅和砷
9
作者 吴怡 虞锐鹏 +2 位作者 陈海兰 曹玉华 李明 《中国无机分析化学》 CAS 北大核心 2024年第11期1471-1477,共7页
为准确测定沉积物中痕量铅和砷的含量,比较不同消解方式与不同混合酸体系对沉积物中铅和砷元素的提取效果,并探讨内标法和标准加入法对质控结果的影响,采用电感耦合等离子体质谱(ICP-MS)法测定,建立了电热板消解/ICP-MS标准加入法同时... 为准确测定沉积物中痕量铅和砷的含量,比较不同消解方式与不同混合酸体系对沉积物中铅和砷元素的提取效果,并探讨内标法和标准加入法对质控结果的影响,采用电感耦合等离子体质谱(ICP-MS)法测定,建立了电热板消解/ICP-MS标准加入法同时测定水系沉积物中铅和砷元素含量的方法。通过分析经认证的标准参考样(GSD-9)来评价方法的准确度。结果显示:采用HCl-HNO_(3)-HF-HClO_(4)体系电热板消解,具有较高的消解回收率;标准加入法可有效清除基质干扰,提高准确度;方法线性关系良好;铅和砷元素的回收率在93.9%~104%,相对标准偏差为4.2%~5.0%(n=6),检出限分别为0.026 mg/kg和0.004 mg/kg。方法的准确度和精密度良好、灵敏度高。为环境中土壤及水系沉积物中痕量重金属元素含量的测定提供了参考分析方法。 展开更多
关键词 沉积物 电热板消解 电感耦合等离子体质谱 标准加入法
下载PDF
Fast Determination of Phenanthrene in Soil by Gas Chroma- tography-Mass Spectrometry Using Chemometric Resolution and Standard Addition Method 被引量:2
10
作者 Weiwei Yu Wensheng Cai Xueguang Shao 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2013年第4期545-550,共6页
A method for fast determination of the component in complex samples by using gas chromatography-mass spectrometry (GC-MS) was developed and used for quantitative analysis of phenanthrene in soils. In the method, win... A method for fast determination of the component in complex samples by using gas chromatography-mass spectrometry (GC-MS) was developed and used for quantitative analysis of phenanthrene in soils. In the method, window independent component analysis (WICA) was used for resolving the mass spectrum and non-negative im- mune algorithm (NNIA) was employed for obtaining the chromatographic profile. Therefore, spectral and chroma- tographic information of a specific component can be obtained from the measured GC-MS data of overlapping and high background. Six soil samples collected from different places were analyzed. The tedious pretreatments in pre- paring the samples and the elution in the separation were simplified for speeding up the analysis. Due to the com- plexity of the matrix, standard addition method was adopted for the final quantification. The applicability of the method was validated with a spiked sample and the results of the six samples are reasonable. 展开更多
关键词 PHENANTHRENE gas chromatography-mass spectrometry standard addition method CHEMOINFORMATICS immune algorithm
原文传递
增材制造用金属粉末的特性和测试方法
11
作者 张龙治 鲍俊 《热处理》 CAS 2024年第4期35-39,共5页
增材制造用金属粉末的外观、化学成分、粒度、球形度、流动性、密度和空心率等特性均影响增材制造件的性能。目前,增材制造用金属粉末的成分、粒度、流动性和密度均有测试标准,但没有外观、球形度和空心率的测试标准。简要介绍了增材制... 增材制造用金属粉末的外观、化学成分、粒度、球形度、流动性、密度和空心率等特性均影响增材制造件的性能。目前,增材制造用金属粉末的成分、粒度、流动性和密度均有测试标准,但没有外观、球形度和空心率的测试标准。简要介绍了增材制造用金属粉末的外观、成分、粒度、球形度、密度、流动性和空心率的测试方法和相关标准。 展开更多
关键词 增材制造 金属粉末 标准 测试方法
下载PDF
极谱法测定注射用亚锡甲氧异腈中氯化亚锡的含量
12
作者 崔晓艳 王玉玺 +9 位作者 杨佳宁 王勇 程缤雁 姜华 刘倩楠 张明艺 范振亚 吴一凡 李岩 杨柳 《标记免疫分析与临床》 CAS 2024年第11期2030-2035,2040,共7页
目的建立注射用亚锡甲氧异腈中氯化亚锡含量的测定方法。方法采用经氮气饱和的0.2mol/L硝酸溶液作为稀释剂,甩汞电极(SMDE)操作模式,以极谱仪从-0.22 V起扫,在电极电位为-0.22~-0.50 V范围内记录极谱峰高,采用标准加入法测定注射用亚锡... 目的建立注射用亚锡甲氧异腈中氯化亚锡含量的测定方法。方法采用经氮气饱和的0.2mol/L硝酸溶液作为稀释剂,甩汞电极(SMDE)操作模式,以极谱仪从-0.22 V起扫,在电极电位为-0.22~-0.50 V范围内记录极谱峰高,采用标准加入法测定注射用亚锡甲氧异腈中氯化亚锡的含量,并进行方法学验证。结果方法学验证结果表明,新建立的方法专属性良好,稀释剂和辅料成分在氯化亚锡出峰位置处无干扰,方法线性良好(Y=0.9644 X+2.6993,r=0.9997),平均回收率(n=6)为102.0%(RSD=2.2%),精密度的RSD为0.8%,注射用亚锡甲氧异腈溶解后在30min内测定比较稳定,相对误差小于3.0%。结论建立的极谱法灵敏、准确,可用于注射用亚锡甲氧异腈中氯化亚锡含量的准确测定,为《中国药典》标准的增订提供了可靠的方法。 展开更多
关键词 注射用亚锡甲氧异腈 氯化亚锡 极谱法 SMDE模式 标准加入法
下载PDF
Using molecular mechanics method and group additive method to estimate the standard enthalpy of organic compounds
13
作者 王贵昌 潘荫明 +2 位作者 李勇军 汪惟为 赵学庄 《Chinese Science Bulletin》 SCIE EI CAS 1996年第19期1613-1617,共5页
It is almost impossible to determine the thermochemical data of all the compounds by experiments. Many methods for estimating the thermochemical data of organics have been proposed in the past 50 years. Benson’s grou... It is almost impossible to determine the thermochemical data of all the compounds by experiments. Many methods for estimating the thermochemical data of organics have been proposed in the past 50 years. Benson’s group additivity method which has the advantage of quickness, ease and accuracy is regarded as the most successful one among these empirical methods. Unfortunately, the group values used in Benson’s method are not sufficient, since they come from the experimental thermochemical data and the number of the groups in Benson’s group additivity method depends on the number of the orginc compounds that can be estimated. In this note, the molecular mechanics method is used 展开更多
关键词 MOLECULAR MECHANICS group additIVE method standard enthalpy.
原文传递
一种硫酸钡废渣中水溶性钡含量的测定方法研究
14
作者 李媛 《盐科学与化工》 CAS 2024年第12期38-39,共2页
文章建立了一种火焰原子吸收光谱法测定硫酸钡废渣中水溶性钡含量的新方法,采用标准加入法消除了样品的基体干扰,同时利用氯化钾溶液消除电离干扰,提高了水溶性钡测定的准确性。该方法还有效避免了硫酸钡废渣综合利用过程中固化剂对水... 文章建立了一种火焰原子吸收光谱法测定硫酸钡废渣中水溶性钡含量的新方法,采用标准加入法消除了样品的基体干扰,同时利用氯化钾溶液消除电离干扰,提高了水溶性钡测定的准确性。该方法还有效避免了硫酸钡废渣综合利用过程中固化剂对水溶性钡含量的测定影响,为硫酸钡废渣处理工艺的研究提供了坚实的分析技术支持。 展开更多
关键词 硫酸钡废渣 水溶性钡 原子吸收光谱法 标准加入法
下载PDF
石墨炉原子吸收标准加入法测定血液滤过置换基础液中的铝含量
15
作者 李震 于玮洁 +2 位作者 栾曾惠 朱韵洁 杨钊 《中国药品标准》 CAS 2024年第2期200-203,共4页
目的:建立石墨炉原子吸收法测定血液滤过置换基础液中铝的含量。方法:采用石墨炉原子吸收标准加入法,加入基体改进剂,测定铝的含量。结果:铝在0~20μg·L^(-1)范围内线性关系良好,r=0.998;检出限浓度为0.91μg·L^(-1);平均回... 目的:建立石墨炉原子吸收法测定血液滤过置换基础液中铝的含量。方法:采用石墨炉原子吸收标准加入法,加入基体改进剂,测定铝的含量。结果:铝在0~20μg·L^(-1)范围内线性关系良好,r=0.998;检出限浓度为0.91μg·L^(-1);平均回收率为96.5%。3批样品测定结果分别为3.299、1.232、2.431μg·L^(-1)。结论:本法可有效地测定血液滤过置换基础液产品中铝的含量,对产品的原料、生产和包装等可能引入污染的途径进行控制。建议企业重视血液滤过置换基础液中铝含量的检测,尽量减小污染风险,保证产品的质量。 展开更多
关键词 石墨炉原子吸收法 标准加入法 血液滤过置换基础液 污染 限度控制
下载PDF
电感耦合等离子体质谱法(ICP-MS)测定光刻胶中痕量元素
16
作者 黄丹宇 《化工技术与开发》 CAS 2024年第10期46-49,共4页
利用电感耦合等离子体质谱仪,建立了一套完整检测光刻胶中Li、Na、Mg、Al、K、Ca、Cr、Mn、Fe、Co、Ni、Zn、Ga、Pd、Ag、Sn、W、Pb、Bi等19种痕量元素的方法。通过仪器调谐,优化电感耦合等离子体质谱仪的工作参数,采用标准加入法校正基... 利用电感耦合等离子体质谱仪,建立了一套完整检测光刻胶中Li、Na、Mg、Al、K、Ca、Cr、Mn、Fe、Co、Ni、Zn、Ga、Pd、Ag、Sn、W、Pb、Bi等19种痕量元素的方法。通过仪器调谐,优化电感耦合等离子体质谱仪的工作参数,采用标准加入法校正基体,考察了该检测方法的检出限、精密度及加标回收率。结果表明,各元素的检出限在0.04~1.46ng·L^(-1)之间,加标回收率在90.0%~109.10%之间,精密度均小于3%。该方法简单易操作,精密度高,准确性好,可满足实际生产中对光刻胶的检测需求。 展开更多
关键词 电感耦合等离子体质谱法 光刻胶 标准加入法 痕量元素
下载PDF
ICP-MS测定HTK液中微量钙含量
17
作者 陈书蓉 樊美霞 +2 位作者 戴鹏 汪毅 朱建东 《广东化工》 CAS 2024年第10期143-145,共3页
目的:基于电感耦合等离子体质谱法(ICP-MS),建立一种测定HTK液中微量钙元素的测试方法。方法:将HTK浓缩液使用1%的硝酸进行稀释,添加钙元素标准溶液制备成系列钙元素标准溶液,选择铟作为内标,采用标准加入法并扣除空白进行测定,并且对... 目的:基于电感耦合等离子体质谱法(ICP-MS),建立一种测定HTK液中微量钙元素的测试方法。方法:将HTK浓缩液使用1%的硝酸进行稀释,添加钙元素标准溶液制备成系列钙元素标准溶液,选择铟作为内标,采用标准加入法并扣除空白进行测定,并且对方法进行精密度、准确度和加标回收进行评估。结果:钙元素含量的测定在0~1.5mg/L的范围内呈现良好的线性关系(R=0.9999,n=7),相对误差(RE)均小于2%,日内精密度RSD均小于1%,回收率为95%~105%。结论:本研究所建立的电感耦合等离子体质谱法能够很好地测定HTK液中微量钙含量,该方法线性范围好,且具有良好的精密度和准确性,为标准完善、质量监督提供了参考依据。 展开更多
关键词 HTK液 钙离子 电感耦合等离子体质谱法 标准加入法 方法优化
下载PDF
标准加入-电感耦合等离子体原子发射光谱法测定K465高温合金中的铪
18
作者 王明珠 曹方 詹平 《广东化工》 CAS 2024年第11期170-172,共3页
K465高温合金作为一种广泛应用的航空结构材料,其中铪含量的准确测定对材料性能的研究具有重要意义。采用电感耦合等离子体原子发射光谱法(ICP-AES)测定K465高温合金中铪的含量,会受到基体元素和合金元素的干扰。试验采用盐酸、硝酸和... K465高温合金作为一种广泛应用的航空结构材料,其中铪含量的准确测定对材料性能的研究具有重要意义。采用电感耦合等离子体原子发射光谱法(ICP-AES)测定K465高温合金中铪的含量,会受到基体元素和合金元素的干扰。试验采用盐酸、硝酸和柠檬酸处理样品,选择277.366 nm、273.876 nm和264.141 nm三个不同波长的分析谱线,并采用干扰较小、准确性高的标准加入法消除了基体元素和合金元素的干扰影响。试验结果表明,标准加入-ICP-AES发测定K465高温合金中的铪的最佳分析谱线波长为264.141 nm,方法检出限为0.002 mg·L^(-1),在此波长下验证方法的回收率为98.7%~104.0%,测量值的相对标准偏差为1.69%~3.20%。本方法准确可靠,能够满足K465高温合金分析的需要。 展开更多
关键词 电感耦合等离子体原子发射光谱法 K465高温合金 标准加入法 干扰消除
下载PDF
超高效液相色谱-串联质谱标准加入法测定芝麻油中乙基麦芽酚
19
作者 潘雯 杨坤 +1 位作者 陈光静 刘桂琼 《粮食与食品工业》 2024年第2期61-64,68,共5页
建立了一种芝麻油中乙基麦芽酚的超高效液相色谱-串联质谱标准加入的检测方法。样品经甲醇溶液提取,以0.1%甲酸水溶液和0.1%甲酸甲醇溶液作为流动相,梯度洗脱,经色谱柱分离,在电喷雾正离子模式下多反应监测,采用标准加入法定量。结果表... 建立了一种芝麻油中乙基麦芽酚的超高效液相色谱-串联质谱标准加入的检测方法。样品经甲醇溶液提取,以0.1%甲酸水溶液和0.1%甲酸甲醇溶液作为流动相,梯度洗脱,经色谱柱分离,在电喷雾正离子模式下多反应监测,采用标准加入法定量。结果表明:在20~200 ng/mL质量浓度范围内线性良好,相关系数r>0.995,回收率为98.4%~99.0%,相对标准偏差(n=6)为0.55%~1.03%。通过参加“CFAPA-2063芝麻香油中乙基麦芽酚的测定”能力验证,样品中乙基麦芽酚的|Z|<0.2,该方法前处理操作简单快速、基质干扰小、灵敏度高,可用于检测芝麻油中乙基麦芽酚含量。 展开更多
关键词 芝麻油 乙基麦芽酚 超高效液相色谱-串联质谱法 标准加入法
下载PDF
ICP-AES标准加入法同时测定钼粉中的多种杂质元素
20
作者 张俊美 李辉 +3 位作者 姚佳人 董园园 栾雪 张昕 《机械工程与自动化》 2024年第3期105-107,共3页
研究并建立了ICP-AES标准加入法同时测定钼粉中Fe、Ni、Al、Cu、Ca和Mg等杂质元素含量的方法。该方法采用盐酸-硝酸溶解样品,以标准加入法配制系列标准工作溶液;待测元素的分析谱线分别为Fe238.204 nm、Ni231.604 nm、Al167.078 nm、Cu3... 研究并建立了ICP-AES标准加入法同时测定钼粉中Fe、Ni、Al、Cu、Ca和Mg等杂质元素含量的方法。该方法采用盐酸-硝酸溶解样品,以标准加入法配制系列标准工作溶液;待测元素的分析谱线分别为Fe238.204 nm、Ni231.604 nm、Al167.078 nm、Cu327.396 nm、Mg280.270 nm、Ca393.366 nm;线性相关系数均达到0.996以上;测定结果的相对标准偏差为1.97%~5.08%,加标回收率为88%~113%;测定结果与国家标准GB/T 4325方法测定结果比对,基本相吻合。该方法测定结果准确可靠,能够满足科研生产对钼粉中Fe、Ni、Al、Cu、Ca和Mg等杂质元素含量测定的需求。 展开更多
关键词 钼粉 ICP-AES 标准加入法
下载PDF
上一页 1 2 26 下一页 到第
使用帮助 返回顶部