Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
The kinetic curves of the high-temperature oxidation of austenitic heat resistant stainless steel 1. 4828 at 1 050 ℃ were measured using a weighing method. It is shown that the oxidation curves at 1 050 ℃ followed t...The kinetic curves of the high-temperature oxidation of austenitic heat resistant stainless steel 1. 4828 at 1 050 ℃ were measured using a weighing method. It is shown that the oxidation curves at 1 050 ℃ followed the parabolic line law, and after 250 h of oxidation, the mass gain was about 80 g/m2. The surface morphology and structure of the oxide layers were studied by scanning electron microscopy and X-ray diffraction. A complicated oxide layer obtained at 1 050 ℃ was mainly composed, from inner to outer, of (FeSi) 3 04, Cr2 03, Fe2 03, and spinel oxides FeCr204 and NiMn204.展开更多
With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed o...With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed of HFOs (HFO-1234yf, HFO-1234ze(z), HFO-1234ze(e) and HFO-1234zf) are developed to substitute for HFC-134a and CFC-114 in air-conditioning and high-temperature heat pump systems, respectively. The cycle performances were evaluated by an improved theoretical cy-cle evaluation methodology. The results showed that all the mixtures proposed herein were favorable refrigerants with excel-lent thermodynamic cycle performances. M1A presented lower discharge temperature and pressure ratio and higher COPc than that of HFC-134a. The volumetric cooling capacity was similar to HFC-134a. It can be served as a good environmentally friendly alternative to replace HFC-134a. M3H delivered similar discharge temperature as CFC-114 did. And the COPh was 3% higher. It exhibits excellent cycle performance in high-temperature heat pump and is a promising refrigerant to substitute for CFC-114. And the gliding temperature differences enable them to exhibit better coefficient of performance by matching the sink/source temperature in practice. Because the toxicity, flammability and other properties are not investigated in detail, ex-tensive toxicity and flammability testing needs to be conducted before they are used in a particular application.展开更多
为解决低温余热资源过剩与高温用热需求紧缺之间的矛盾,设计了一套基于准二级压缩的高温热泵机组,理论分析循环流程并进行优化设计,采用闪蒸器与回热器组合提高机组性能,开展了机组的性能实验,以制热量、制热COP、[火用]效率、冷凝压力...为解决低温余热资源过剩与高温用热需求紧缺之间的矛盾,设计了一套基于准二级压缩的高温热泵机组,理论分析循环流程并进行优化设计,采用闪蒸器与回热器组合提高机组性能,开展了机组的性能实验,以制热量、制热COP、[火用]效率、冷凝压力、排气温度为性能指标,在冷凝器出水温度为85~120℃,蒸发器进水温度为50、60、70℃工况下,对机组性能进行分析。实测机组性能与理论计算结果吻合,蒸发器进水温度为49.8℃,冷凝器出水温度为118.1℃,机组制热量可达916.3 k W,制热COP为2.51,[火用]效率为46.3%,机组冷凝压力为1.8 MPa,排气温度为137℃,符合机组安全运行的要求。展开更多
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
文摘The kinetic curves of the high-temperature oxidation of austenitic heat resistant stainless steel 1. 4828 at 1 050 ℃ were measured using a weighing method. It is shown that the oxidation curves at 1 050 ℃ followed the parabolic line law, and after 250 h of oxidation, the mass gain was about 80 g/m2. The surface morphology and structure of the oxide layers were studied by scanning electron microscopy and X-ray diffraction. A complicated oxide layer obtained at 1 050 ℃ was mainly composed, from inner to outer, of (FeSi) 3 04, Cr2 03, Fe2 03, and spinel oxides FeCr204 and NiMn204.
基金supported by the National Natural Science Foundation of China (Grant No. 50976079)Science and Technology Support Key Project of Tianjin (Grant No. 10ZCKFGX01700)
文摘With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed of HFOs (HFO-1234yf, HFO-1234ze(z), HFO-1234ze(e) and HFO-1234zf) are developed to substitute for HFC-134a and CFC-114 in air-conditioning and high-temperature heat pump systems, respectively. The cycle performances were evaluated by an improved theoretical cy-cle evaluation methodology. The results showed that all the mixtures proposed herein were favorable refrigerants with excel-lent thermodynamic cycle performances. M1A presented lower discharge temperature and pressure ratio and higher COPc than that of HFC-134a. The volumetric cooling capacity was similar to HFC-134a. It can be served as a good environmentally friendly alternative to replace HFC-134a. M3H delivered similar discharge temperature as CFC-114 did. And the COPh was 3% higher. It exhibits excellent cycle performance in high-temperature heat pump and is a promising refrigerant to substitute for CFC-114. And the gliding temperature differences enable them to exhibit better coefficient of performance by matching the sink/source temperature in practice. Because the toxicity, flammability and other properties are not investigated in detail, ex-tensive toxicity and flammability testing needs to be conducted before they are used in a particular application.
文摘为解决低温余热资源过剩与高温用热需求紧缺之间的矛盾,设计了一套基于准二级压缩的高温热泵机组,理论分析循环流程并进行优化设计,采用闪蒸器与回热器组合提高机组性能,开展了机组的性能实验,以制热量、制热COP、[火用]效率、冷凝压力、排气温度为性能指标,在冷凝器出水温度为85~120℃,蒸发器进水温度为50、60、70℃工况下,对机组性能进行分析。实测机组性能与理论计算结果吻合,蒸发器进水温度为49.8℃,冷凝器出水温度为118.1℃,机组制热量可达916.3 k W,制热COP为2.51,[火用]效率为46.3%,机组冷凝压力为1.8 MPa,排气温度为137℃,符合机组安全运行的要求。