A rapid, straightforward, sensitive, efficient, and cost-effective reverse-phase high-performance liquid chromatographic method was employed for the simultaneous determination of Sorbitol, Sodium Lactate, and Chloride...A rapid, straightforward, sensitive, efficient, and cost-effective reverse-phase high-performance liquid chromatographic method was employed for the simultaneous determination of Sorbitol, Sodium Lactate, and Chlorides in a drug solution for infusion. Sorbitol, Sodium lactate, and Chloride are all officially recognized in the USP monograph. Assay methods are provided through various techniques, with titrations being ineffective for trace-level quantification. Alternatively, IC, AAS, and ICP-MS, though highly accurate, are costly and often unavailable to most testing facilities. When considering methods, it’s important to prioritize both quality control requirements and user-friendly techniques. A simple HPLC simultaneous method was developed for the quantification of Chlorides, Sorbitol, and Sodium Lactate with a shorter run time. The separation utilized a Shimpack SCR-102(H) ion exclusion analytical column (7.9 mm × 300 mm, 7 μm), with a flow rate of 0.6 mL per min. The column compartment temperature was maintained at 40°C, and the injection volume was set at 10 μL, with detection at 200 nm. All measurements were conducted in a 0.1% solution of phosphoric acid. The analytical curves demonstrated linearity (r > 0.9999) in the concentration range of 0.79 to 3.8 mg per mL for Sodium Lactate (SL), 0.16 to 0.79 mg per mL for Sodium Chloride (SC), and 1.5 to 7.2 mg per mL for Sorbitol. Validation of the developed method followed the guidelines of the International Conference on Harmonization (ICH Q2B) and USP. The method exhibited precision, robustness, accuracy, and selectivity. In accelerated stability testing over 6 months, no significant variations were observed in organoleptic analysis and pH. Consequently, the developed method is deemed suitable for routine quality control analyses, enabling the simultaneous determination of Sodium Lactate, Sodium Chloride, and Sorbitol in pharmaceutical formulations and infusions.展开更多
In this editorial,we comment on an article published in a recent issue of the World Journal of Clinical Cases.There is a pressing need for reliable tools for diagnosing tuberculosis(TB)of the gastrointestinal tract.De...In this editorial,we comment on an article published in a recent issue of the World Journal of Clinical Cases.There is a pressing need for reliable tools for diagnosing tuberculosis(TB)of the gastrointestinal tract.Despite advancements in the diagnosis and treatment,TB remains a global health challenge.Ali et al demon-strated that TB may mimic gastrointestinal conditions,such as gastric outlet obstruction,causing a delay in the diagnosis.Furthermore,the latter complication is frequently observed during infections,including Helicobacter pylori,and rarely is related to TB,as in the presented case.In line with this,we think that laboratory tests based on interferon-gamma release assays can be a helpful tool for diagnosing latent TB paced in the gastrointestinal tract.Innovative strategies and approaches for diagnosing latent/active extra pulmonary TB are crucial for establishing the diagnosis early and enhancing treatment strategies to mitigate the global burden of TB.展开更多
Background: This study aimed to evaluate the diagnostic value of interferon-γ release assay (IGRA), a sensitive microbiological diagnostic method, in children and adolescents with suspected tuberculosis in a country ...Background: This study aimed to evaluate the diagnostic value of interferon-γ release assay (IGRA), a sensitive microbiological diagnostic method, in children and adolescents with suspected tuberculosis in a country with a high burden of tuberculosis. Method: This study included 581 children and adolescents aged 4 - 19 years who were suspected of having tuberculosis, were latently infected with Mycobacterium tuberculosis, and had received at least one dose of BCG vaccine between April 17, 2019, and February 24, 2021. The study evaluated the TST results of 106 patients who had a positive Quantiferon test and were suspected of having tuberculosis. Results: The study included 581 patients aged between 4 and 19 years. Of these, 106 patients tested positive for the Quantiferon test, while 19 were indeterminate and 456 were negative. The Quantiferon test positivity rate was 18.24%. Among the 106 QFT-Plus-positive cases, 23 patients also tested positive for TST. The difference in distribution was found to be statistically significant. Conclusion: The QFT-Plus test is considered an alternative to TST and other microbiological diagnostic methods for early tuberculosis diagnosis, particularly in children and adolescents.展开更多
Recently increasing concerns from the scientists and public have been paid for seawater pollution due to tetracycline(TC)overuse in maricultural area.However,there are few methods or instruments that can be used for s...Recently increasing concerns from the scientists and public have been paid for seawater pollution due to tetracycline(TC)overuse in maricultural area.However,there are few methods or instruments that can be used for specific and rapid detection of this antibiotic in seawater.In this study,the colloidal gold immunochromatographic assay(CG-ICA)was used to achieve this goal.A commercialized monoclonal antibody against TC(anti-TC mAb)was selected because of its higher sensitivity(half-maximal inhibitory concentration of 2.38μgL^(-1)).The prepared CG particles(average diameter of 20 nm)were used to label anti-TC mAb at pH 8.0.The conjugate pad was formed by spraying the CG-labeled anti-TC mAb on a glass fibre membrane followed by proper dryness.The test pad was made by immobilizing artificial antigen and anti-mouse mAb in the test line and the control line,respectively,in a nitrocellulose membrane.The test strip,assembled with sample pad,conjugate pad,test pad and absorbent pad,could be used to detect TC during seawater sample flowing through these components in turn.The results could be observed by the naked eye in 10min.The visible limit of detection(vLOD)was 20μgL^(-1) for TC in seawater.The CG-ICA test results were in good agreement with those of liquid chromatography-tandem mass spectrometry(LC-MS/MS).The assay also showed that,oxytetracycline(OTC)and chlortetracycline(CTC),as the structural analogues of TC,did not interfere with TC determination.Furthermore,the TC concentration given by test strip could not be affected by the fluctuation of temperature(10℃–30℃),pH(7–9)and salinity(0–40)of seawater.Therefore,CG-ICA is a suitable tool for rapid,on-site,and semi-quantitative detection of TC in seawater.展开更多
AIM:To report a novel splicing mutation in the RPGR gene(encoding retinitis pigmentosa GTPase regulator)in a three-generation Chinese family with X-linked retinitis pigmentosa(XLRP).METHODS:Comprehensive ophthalmic ex...AIM:To report a novel splicing mutation in the RPGR gene(encoding retinitis pigmentosa GTPase regulator)in a three-generation Chinese family with X-linked retinitis pigmentosa(XLRP).METHODS:Comprehensive ophthalmic examinations including best corrected visual acuity,fundus photography,vision field,and pattern-visual evoked potential were performed to identify the disease phenotype of a six-yearold boy from the family(proband).Genomic DNA was extracted from peripheral blood of five available members of the pedigree.Whole-exome sequencing(WES),Sanger sequencing,and pSPL3-based exon trapping were used to investigate the aberrant splicing of RPGR.Human Splice Finder v3.1 and NNSPLICE v0.9 were used for in silico prediction of splice site variants.RESULTS:The proband was diagnosed as having retinitis pigmentosa(RP).He had severe symptoms with early onset.A novel splicing mutation,c.619+1G>C in RPGR was identified in the proband by WES and in four family members by Sanger sequencing.Minigene splicing assays verified that c.619+1G>C in RPGR would result in the formation of a damaging alternative transcript in which the last 91 bp of exon 6 were skipped,leading to the subsequent deletion of 623 correct amino acids(c.529_619del p.Val177Glnfs*16).CONCLUSION:We identify a novel splice donor site mutation causing aberrant splicing of RPGR.Our findings add to the catalog of pathological mutations of RPGR and further emphasize the functional importance of RPGR in RP pathogenesis and its complex clinical phenotypes.展开更多
Introduction: The Central African Republic is one of the 30 high Tuberculosis burden countries in the world, with an incidence of 540 cases per 100,000 population and a mortality of 91 deaths per 100,000 population. S...Introduction: The Central African Republic is one of the 30 high Tuberculosis burden countries in the world, with an incidence of 540 cases per 100,000 population and a mortality of 91 deaths per 100,000 population. Since 2020, following WHO recommendations, the National Reference Laboratory for Tuberculosis has been using the Xpert<sup>®</sup> MTB/RIF assay as a first-line diagnostic test for the early detection of Drug Resistance Tuberculosis. The goal of this study was to evaluate the contribution of the Xpert<sup>®</sup> MTB/RIF assay to the surveillance of rifampicin resistance in new and previously treated tuberculosis cases. Materials and Methods: The data relative to the Xpert<sup>®</sup> MTB/RIF assay carried out on various categories of tuberculosis patients registered at the National Reference Laboratory for Tuberculosis in 2020 were analyzed retrospectively. The categories of tuberculosis patients were new cases, failed treatment cases, relapse cases, lost-to-follow-up cases and multidrug-resistant tuberculosis contact cases. Results: A total of 1404 tuberculosis patients were registered at the NRL-TB in 2020;the mean age was 39.2 years (2 - 90 years) and the male-to-female sex ratio was 1.16:1. Overall, 32.7% (454/1404) proved infected with tuberculosis, of which 22.5% (102/454) cases showed resistance to rifampicin. The primary resistance rate was 9.1% (27/298) and the secondary resistance rate was 46.6% (75/161). Treatment failures and relapsed cases were significantly associated with rifampicin resistance (p 0.005). Conclusion: Large-scale use of Xpert<sup>®</sup> MTB/RIF, especially in the provinces of the Central African Republic, will help the Ministry of Health to better control Drug Resistance Tuberculosis in the country.展开更多
Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixa...Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixation in the global ocean remain uncertain,partly because of the lack of methodological uniformity.The^(15)N_(2)tracer assay(the original bubble method→the^(15)N_(2)-enriched seawater method→the modified bubble method)is the mainstream method for field measurements of N2 fixation rates(NFRs),among which the original bubble method is the most frequently used.However,accumulating evidence has suggested an underestimation of NFRs when using this method.To improve the availability of previous data,we compared NFRs measured by three^(15)N_(2)tracer assays in the South China Sea.Our results indicate that the relationship between NFRs measured by the original bubble method and the^(15)N_(2)-enriched seawater method varies obviously with area and season,which may be influenced by incubation time,diazotrophic composition,and environmental factors.In comparison,the relationship between NFRs measured by the original bubble method and the modified bubble method is more stable,indicating that the N2 fixation rates based on the original bubble methods may be underestimated by approximately 50%.Based on this result,we revised the flux of N2 fixation in the South China Sea to 40 mmol/(m2·a).Our results improve the availability and comparability of literature NFR data in the South China Sea.The comparison of the^(15)N_(2)tracer assay for NFRs measurements on a larger scale is urgently necessary over the global ocean for a more robust understanding of the role of N2 fixation in the marine nitrogen cycle.展开更多
目的建立以高效液相色谱-蒸发光散射检测器(HPLC-ELSD)法测定依托红霉素片含量的方法。方法大曹三耀(OSAKA SODA GROUP)CAPCELL PAK C_(18) MGⅡS5色谱柱,0.03%二乙胺-乙腈(30∶70,V/V)为流动相,流速为0.9 mL·min^(-1),进样量10μL...目的建立以高效液相色谱-蒸发光散射检测器(HPLC-ELSD)法测定依托红霉素片含量的方法。方法大曹三耀(OSAKA SODA GROUP)CAPCELL PAK C_(18) MGⅡS5色谱柱,0.03%二乙胺-乙腈(30∶70,V/V)为流动相,流速为0.9 mL·min^(-1),进样量10μL,柱温40℃。ELSD参数:漂移管温度45℃,载气流速3.3 L·min^(-1),增益为6。结果依托红霉素在0.209~1.257 mg·mL^(-1)的浓度范围内线性关系良好(r=0.9991);精密度、稳定性、重复性试验的RSD<1.5%;加标回收率平均值为99.6%;定量限为0.209μg,检测限为0.067μg。结论该方法操作简单、准确灵敏、稳定性好,可用于依托红霉素片的含量测定。展开更多
文摘A rapid, straightforward, sensitive, efficient, and cost-effective reverse-phase high-performance liquid chromatographic method was employed for the simultaneous determination of Sorbitol, Sodium Lactate, and Chlorides in a drug solution for infusion. Sorbitol, Sodium lactate, and Chloride are all officially recognized in the USP monograph. Assay methods are provided through various techniques, with titrations being ineffective for trace-level quantification. Alternatively, IC, AAS, and ICP-MS, though highly accurate, are costly and often unavailable to most testing facilities. When considering methods, it’s important to prioritize both quality control requirements and user-friendly techniques. A simple HPLC simultaneous method was developed for the quantification of Chlorides, Sorbitol, and Sodium Lactate with a shorter run time. The separation utilized a Shimpack SCR-102(H) ion exclusion analytical column (7.9 mm × 300 mm, 7 μm), with a flow rate of 0.6 mL per min. The column compartment temperature was maintained at 40°C, and the injection volume was set at 10 μL, with detection at 200 nm. All measurements were conducted in a 0.1% solution of phosphoric acid. The analytical curves demonstrated linearity (r > 0.9999) in the concentration range of 0.79 to 3.8 mg per mL for Sodium Lactate (SL), 0.16 to 0.79 mg per mL for Sodium Chloride (SC), and 1.5 to 7.2 mg per mL for Sorbitol. Validation of the developed method followed the guidelines of the International Conference on Harmonization (ICH Q2B) and USP. The method exhibited precision, robustness, accuracy, and selectivity. In accelerated stability testing over 6 months, no significant variations were observed in organoleptic analysis and pH. Consequently, the developed method is deemed suitable for routine quality control analyses, enabling the simultaneous determination of Sodium Lactate, Sodium Chloride, and Sorbitol in pharmaceutical formulations and infusions.
基金The European Union-Next Generation EU,through the National Recovery and Resilience Plan of the Republic of Bulgaria,Project,No.BG-RRP-2.004-0008.
文摘In this editorial,we comment on an article published in a recent issue of the World Journal of Clinical Cases.There is a pressing need for reliable tools for diagnosing tuberculosis(TB)of the gastrointestinal tract.Despite advancements in the diagnosis and treatment,TB remains a global health challenge.Ali et al demon-strated that TB may mimic gastrointestinal conditions,such as gastric outlet obstruction,causing a delay in the diagnosis.Furthermore,the latter complication is frequently observed during infections,including Helicobacter pylori,and rarely is related to TB,as in the presented case.In line with this,we think that laboratory tests based on interferon-gamma release assays can be a helpful tool for diagnosing latent TB paced in the gastrointestinal tract.Innovative strategies and approaches for diagnosing latent/active extra pulmonary TB are crucial for establishing the diagnosis early and enhancing treatment strategies to mitigate the global burden of TB.
文摘Background: This study aimed to evaluate the diagnostic value of interferon-γ release assay (IGRA), a sensitive microbiological diagnostic method, in children and adolescents with suspected tuberculosis in a country with a high burden of tuberculosis. Method: This study included 581 children and adolescents aged 4 - 19 years who were suspected of having tuberculosis, were latently infected with Mycobacterium tuberculosis, and had received at least one dose of BCG vaccine between April 17, 2019, and February 24, 2021. The study evaluated the TST results of 106 patients who had a positive Quantiferon test and were suspected of having tuberculosis. Results: The study included 581 patients aged between 4 and 19 years. Of these, 106 patients tested positive for the Quantiferon test, while 19 were indeterminate and 456 were negative. The Quantiferon test positivity rate was 18.24%. Among the 106 QFT-Plus-positive cases, 23 patients also tested positive for TST. The difference in distribution was found to be statistically significant. Conclusion: The QFT-Plus test is considered an alternative to TST and other microbiological diagnostic methods for early tuberculosis diagnosis, particularly in children and adolescents.
基金The authors acknowledge the financial support from the National Natural Science Foundation of China(No.42077335).
文摘Recently increasing concerns from the scientists and public have been paid for seawater pollution due to tetracycline(TC)overuse in maricultural area.However,there are few methods or instruments that can be used for specific and rapid detection of this antibiotic in seawater.In this study,the colloidal gold immunochromatographic assay(CG-ICA)was used to achieve this goal.A commercialized monoclonal antibody against TC(anti-TC mAb)was selected because of its higher sensitivity(half-maximal inhibitory concentration of 2.38μgL^(-1)).The prepared CG particles(average diameter of 20 nm)were used to label anti-TC mAb at pH 8.0.The conjugate pad was formed by spraying the CG-labeled anti-TC mAb on a glass fibre membrane followed by proper dryness.The test pad was made by immobilizing artificial antigen and anti-mouse mAb in the test line and the control line,respectively,in a nitrocellulose membrane.The test strip,assembled with sample pad,conjugate pad,test pad and absorbent pad,could be used to detect TC during seawater sample flowing through these components in turn.The results could be observed by the naked eye in 10min.The visible limit of detection(vLOD)was 20μgL^(-1) for TC in seawater.The CG-ICA test results were in good agreement with those of liquid chromatography-tandem mass spectrometry(LC-MS/MS).The assay also showed that,oxytetracycline(OTC)and chlortetracycline(CTC),as the structural analogues of TC,did not interfere with TC determination.Furthermore,the TC concentration given by test strip could not be affected by the fluctuation of temperature(10℃–30℃),pH(7–9)and salinity(0–40)of seawater.Therefore,CG-ICA is a suitable tool for rapid,on-site,and semi-quantitative detection of TC in seawater.
基金Supported by National Natural Science Foundation of China(No.31751003)Natural Science Foundation of Zhejiang Province(No.LY20H120009)+1 种基金Health Commission of Zhejiang Province(No.2022KY168)Beijing Bethune Charitable Foundation(No.BJ-GY2021013J).
文摘AIM:To report a novel splicing mutation in the RPGR gene(encoding retinitis pigmentosa GTPase regulator)in a three-generation Chinese family with X-linked retinitis pigmentosa(XLRP).METHODS:Comprehensive ophthalmic examinations including best corrected visual acuity,fundus photography,vision field,and pattern-visual evoked potential were performed to identify the disease phenotype of a six-yearold boy from the family(proband).Genomic DNA was extracted from peripheral blood of five available members of the pedigree.Whole-exome sequencing(WES),Sanger sequencing,and pSPL3-based exon trapping were used to investigate the aberrant splicing of RPGR.Human Splice Finder v3.1 and NNSPLICE v0.9 were used for in silico prediction of splice site variants.RESULTS:The proband was diagnosed as having retinitis pigmentosa(RP).He had severe symptoms with early onset.A novel splicing mutation,c.619+1G>C in RPGR was identified in the proband by WES and in four family members by Sanger sequencing.Minigene splicing assays verified that c.619+1G>C in RPGR would result in the formation of a damaging alternative transcript in which the last 91 bp of exon 6 were skipped,leading to the subsequent deletion of 623 correct amino acids(c.529_619del p.Val177Glnfs*16).CONCLUSION:We identify a novel splice donor site mutation causing aberrant splicing of RPGR.Our findings add to the catalog of pathological mutations of RPGR and further emphasize the functional importance of RPGR in RP pathogenesis and its complex clinical phenotypes.
文摘Introduction: The Central African Republic is one of the 30 high Tuberculosis burden countries in the world, with an incidence of 540 cases per 100,000 population and a mortality of 91 deaths per 100,000 population. Since 2020, following WHO recommendations, the National Reference Laboratory for Tuberculosis has been using the Xpert<sup>®</sup> MTB/RIF assay as a first-line diagnostic test for the early detection of Drug Resistance Tuberculosis. The goal of this study was to evaluate the contribution of the Xpert<sup>®</sup> MTB/RIF assay to the surveillance of rifampicin resistance in new and previously treated tuberculosis cases. Materials and Methods: The data relative to the Xpert<sup>®</sup> MTB/RIF assay carried out on various categories of tuberculosis patients registered at the National Reference Laboratory for Tuberculosis in 2020 were analyzed retrospectively. The categories of tuberculosis patients were new cases, failed treatment cases, relapse cases, lost-to-follow-up cases and multidrug-resistant tuberculosis contact cases. Results: A total of 1404 tuberculosis patients were registered at the NRL-TB in 2020;the mean age was 39.2 years (2 - 90 years) and the male-to-female sex ratio was 1.16:1. Overall, 32.7% (454/1404) proved infected with tuberculosis, of which 22.5% (102/454) cases showed resistance to rifampicin. The primary resistance rate was 9.1% (27/298) and the secondary resistance rate was 46.6% (75/161). Treatment failures and relapsed cases were significantly associated with rifampicin resistance (p 0.005). Conclusion: Large-scale use of Xpert<sup>®</sup> MTB/RIF, especially in the provinces of the Central African Republic, will help the Ministry of Health to better control Drug Resistance Tuberculosis in the country.
基金The National Natural Science Foundation of China under contract Nos 42076042 and 41721005the Fund of Ministry of Science and Technology of China under contract No.2017FY201403the Fund of China Ocean Mineral Resources R&D Association under contract No.DY135-13-E2-03.
文摘Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixation in the global ocean remain uncertain,partly because of the lack of methodological uniformity.The^(15)N_(2)tracer assay(the original bubble method→the^(15)N_(2)-enriched seawater method→the modified bubble method)is the mainstream method for field measurements of N2 fixation rates(NFRs),among which the original bubble method is the most frequently used.However,accumulating evidence has suggested an underestimation of NFRs when using this method.To improve the availability of previous data,we compared NFRs measured by three^(15)N_(2)tracer assays in the South China Sea.Our results indicate that the relationship between NFRs measured by the original bubble method and the^(15)N_(2)-enriched seawater method varies obviously with area and season,which may be influenced by incubation time,diazotrophic composition,and environmental factors.In comparison,the relationship between NFRs measured by the original bubble method and the modified bubble method is more stable,indicating that the N2 fixation rates based on the original bubble methods may be underestimated by approximately 50%.Based on this result,we revised the flux of N2 fixation in the South China Sea to 40 mmol/(m2·a).Our results improve the availability and comparability of literature NFR data in the South China Sea.The comparison of the^(15)N_(2)tracer assay for NFRs measurements on a larger scale is urgently necessary over the global ocean for a more robust understanding of the role of N2 fixation in the marine nitrogen cycle.
文摘目的建立以高效液相色谱-蒸发光散射检测器(HPLC-ELSD)法测定依托红霉素片含量的方法。方法大曹三耀(OSAKA SODA GROUP)CAPCELL PAK C_(18) MGⅡS5色谱柱,0.03%二乙胺-乙腈(30∶70,V/V)为流动相,流速为0.9 mL·min^(-1),进样量10μL,柱温40℃。ELSD参数:漂移管温度45℃,载气流速3.3 L·min^(-1),增益为6。结果依托红霉素在0.209~1.257 mg·mL^(-1)的浓度范围内线性关系良好(r=0.9991);精密度、稳定性、重复性试验的RSD<1.5%;加标回收率平均值为99.6%;定量限为0.209μg,检测限为0.067μg。结论该方法操作简单、准确灵敏、稳定性好,可用于依托红霉素片的含量测定。