Application of new directional logic to improve DC side fault discrimination for high resistance faults in HVDC grids 被引量:7
1
作者 Naushath M.HALEEM Athula D.RAJAPAKSE 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期560-573,共14页
This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the... This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the di/dt limiting inductors at the line terminals. A local measurement based secure and fast protection method is implemented by supervising a basic ROCOV relay with a directional element. This directional information is also used to develop a slower communication based DC line protection scheme for detecting high resistance faults. The proposed protection scheme is applied to a multi-level modular converter based three-terminal HVDC grid and its security and sensitivity are evaluated through electromagnetic transient simulations. A methodology to set the protection thresholds considering the constraints imposed by the breaker technology and communication delays is also presented. With properly designed di/dt limiting inductors,the ability of clearing any DC transmission system fault before fault currents exceeds a given breaker capacity is demonstrated. 展开更多
关键词 Directional relay DC line protection Multiterminal hvdc grid protection Rate of change of voltage(ROCOV)based hvdc transmission fault detection
原文传递
Study on Clamping Type DC Circuit Breaker with Short Fault Isolation Time and Low Energy Dissipation
2
作者 Xibei Zhao Gen Li +1 位作者 Jianzhong Xu Jinsha Yuan 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1743-1752,共10页
The development of DC grids faces challenges from DC fault protection.The conventional DC circuit breaker(DCCB)employs metal-oxide varistor(MOV)to isolate the faulted line,in which the fault isolation process is coupl... The development of DC grids faces challenges from DC fault protection.The conventional DC circuit breaker(DCCB)employs metal-oxide varistor(MOV)to isolate the faulted line,in which the fault isolation process is coupled with the energy dissipation process.In this study,a clamping type DCCB(CTCB)using internal capacitors to clamp the converter voltage is proposed.Thanks to the proposed configuration,fault isolation and energy dissipation are decoupled,resulting in a fast fault isolation and low energy dissipation compared to the conventional DCCB.The working principle of the proposed CTCB is presented and verified in a DC grid simulation model.A comparison is made with the traditional DCCB.The fault isolation time can be reduced by 34.5%.The dissipated energy can be reduced by 17.4%.The energy dissipation power can be reduced by 76.2%. 展开更多
关键词 DC circuit breaker DC fault DC protection hvdc grid MMC