该文基于系列文章1建立的电网换相换流器型高压直流(line commutated converter-based high voltage direct current,LCC-HVDC)阻抗模型,开展新能源基地经LCC-HVDC送出系统阻抗特性和振荡机理分析。首先,研究LCC-HVDC送端交流端口阻抗...该文基于系列文章1建立的电网换相换流器型高压直流(line commutated converter-based high voltage direct current,LCC-HVDC)阻抗模型,开展新能源基地经LCC-HVDC送出系统阻抗特性和振荡机理分析。首先,研究LCC-HVDC送端交流端口阻抗与阀本体交流阻抗、交流滤波器阻抗间的构成关系,分析直流线路、受端换流站、受端电网强度对送端换流站阀本体交流阻抗的主导影响;然后,研究送端换流站直流电流环对阀本体交流阻抗的重叠效应,分析送端换流站交流端口阻抗次/超同步频段负阻尼特性形成机理,并论述受端换流站和受端电网强度对送端交流端口阻抗特性的交互影响;接下来,建立新能源基地经LCC-HVDC送出系统等值模型,研究送端系统振荡边界条件,阐明LCC-HVDC对新能源并网点阻抗特性影响的变化规律,揭示直驱风机(permanent magnet synchronous generator,PMSG)、双馈风机(doubly-fed induction generator,DFIG)、光伏(photovoltaic,PV)不同类型新能源基地经LCC-HVDC送出系统次/超同步振荡机理;最后,不同类型新能源基地经LCC-HVDC送出系统仿真结果验证了该文提出的次/超同步振荡机理的正确性和通用性。展开更多
This paper proposes a novel directional pilot protection method based on the transient energy for bipolar HVDC line.Supposing the positive direction of current is from DC bus to the DC line,in the case of an internal ...This paper proposes a novel directional pilot protection method based on the transient energy for bipolar HVDC line.Supposing the positive direction of current is from DC bus to the DC line,in the case of an internal line fault,the transient energies detected on both sides of the line are all negative within a short time,which denotes the positive direction fault;while for an external fault,the transient energy on one end is positive,which means a negative direction fault,but the transient energy on the opposite end is negative,which indicates that the fault direction is positive.According to these characteristics,an integration criterion identifying fault direction is constructed.In addition,through setting a fixed energy threshold,the faulted line and lightning disturbance can also be discriminated.Simulation results from UHVDC transmission system show the validity of the proposed protection method.展开更多
与常规直流相比,永富直流逆变站存在功率全送和功率分送运行方式,而其处于分网接入方式时电网换相换流器高压直流输电(line commutated converter based high voltage directcurrent,LCC-HVDC)系统的交互振荡模式及特征尚不明确。针对...与常规直流相比,永富直流逆变站存在功率全送和功率分送运行方式,而其处于分网接入方式时电网换相换流器高压直流输电(line commutated converter based high voltage directcurrent,LCC-HVDC)系统的交互振荡模式及特征尚不明确。针对这一特殊运行方式,采用模块化建模的思路建立可以反映系统电气/控制回路间交互耦合路径的运动方程模型。在此基础上,依据系统整流侧-逆变侧、正极-负极间的交互耦合路径分解得到影响系统主导模式稳定性的3条扰动传递路径,即整流侧内部自稳性路径、逆变侧内部自稳性路径、双极交互作用致稳性路径。最后,设置不同工况下的案例,量化评估不同作用路径提供的阻尼大小,并通过仿真验证运动方程模型及扰动传递路径分析结果的正确性,为后续研究分网接入方式下LCC-HVDC系统交互振荡模式的阻尼特征提供模型基础。展开更多
为研究分网接入方式下电网换相换流器高压直流输电(line commutated converter based high voltage direct current,LCC-HVDC)系统的交互振荡模式及阻尼特征,基于系统的状态空间模型及系列文章(一)建立的运动方程模型,提取了表征逆变侧...为研究分网接入方式下电网换相换流器高压直流输电(line commutated converter based high voltage direct current,LCC-HVDC)系统的交互振荡模式及阻尼特征,基于系统的状态空间模型及系列文章(一)建立的运动方程模型,提取了表征逆变侧电气与控制环节强耦合特性的多个弱阻尼交互振荡模式,研究了不同短路比工况下交互振荡模式的变化特征。在此基础上,通过复转矩系数法量化评估了整流侧/逆变侧内部自稳性路径及双极交互作用致稳性路径对主导交互振荡模式阻尼特性的贡献度。结果表明:1)不同短路比工况下交互振荡模式的阻尼比会进行重新分配;2)当逆变侧正负极短路比相差较大时,双极交互作用较弱,正负极系统的稳定性由2个交互振荡模式各自主导,且稳定性特征有所差异;3)当逆变侧正负极短路比相近时,双极间动态交互加强,交互振荡模式会同时主导参与系统两极的稳定性,正负极稳定性特征相似。展开更多
The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Bas...The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation.展开更多
Renewable sources of energy are being integrated into the power grids due to their economic and environmental merits as compared with the traditional fossil-fuel-fired power generation. However, their significant pene...Renewable sources of energy are being integrated into the power grids due to their economic and environmental merits as compared with the traditional fossil-fuel-fired power generation. However, their significant penetration demands a thorough research in terms of system reliability, that is, security and stability. In this paper, Security Constrained Multi Objective Dynamic Economic Dispatch (SCMODED) problem considering cubic thermal cubic cost function, wind, solar penetration, cubic transmission power losses and cubic emissions cost function as objectives is first formulated. Both HVDC and HVAC lines are included in their formulation. Various approaches like probabilistic load flow (PLF), scenario based method, participation factors and Harmony Search algorithm etc. are employed in the solution process. Security and stability effects of renewable energy (RE) penetration are investigated and analyzed. The simulated results reveal that RE penetration leads to reduced cost and emissions and increased security concerns. Further, there is increased power system instability and hence increased load shedding so as to help the power system attain steady state stability. Inclusion of HVDC lines facilitates rapid and fast control to increase the transient stability limit by the action of the converter ignition angle (CIA) and converter extinction angle (CEA).展开更多
The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVD...The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVDC transmission lines based on correlation analysis is proposed in this paper. In the principle, external fault is equivalent to a positive capacitance model, so the correlation coefficient of the current and voltage derivative is 1;while the internal fault is equivalent to a negative capacitance model, so the correlation coefficient of the current and voltage derivative is -1. Internal faults and external faults can be distinguished by judging the correlation coefficient. Theoretical analysis and PSCAD simulation experiments show that the new principle, which is simple, not affected by transition resistance, control type and line distributed capacitance current, can identify internal faults and external faults reliably and rapidly, having certain practical value.展开更多
文摘该文基于系列文章1建立的电网换相换流器型高压直流(line commutated converter-based high voltage direct current,LCC-HVDC)阻抗模型,开展新能源基地经LCC-HVDC送出系统阻抗特性和振荡机理分析。首先,研究LCC-HVDC送端交流端口阻抗与阀本体交流阻抗、交流滤波器阻抗间的构成关系,分析直流线路、受端换流站、受端电网强度对送端换流站阀本体交流阻抗的主导影响;然后,研究送端换流站直流电流环对阀本体交流阻抗的重叠效应,分析送端换流站交流端口阻抗次/超同步频段负阻尼特性形成机理,并论述受端换流站和受端电网强度对送端交流端口阻抗特性的交互影响;接下来,建立新能源基地经LCC-HVDC送出系统等值模型,研究送端系统振荡边界条件,阐明LCC-HVDC对新能源并网点阻抗特性影响的变化规律,揭示直驱风机(permanent magnet synchronous generator,PMSG)、双馈风机(doubly-fed induction generator,DFIG)、光伏(photovoltaic,PV)不同类型新能源基地经LCC-HVDC送出系统次/超同步振荡机理;最后,不同类型新能源基地经LCC-HVDC送出系统仿真结果验证了该文提出的次/超同步振荡机理的正确性和通用性。
基金National Natural Science Foundation of China(51677109)National Key Research and Development Program of China(2016YFB0906003).
文摘This paper proposes a novel directional pilot protection method based on the transient energy for bipolar HVDC line.Supposing the positive direction of current is from DC bus to the DC line,in the case of an internal line fault,the transient energies detected on both sides of the line are all negative within a short time,which denotes the positive direction fault;while for an external fault,the transient energy on one end is positive,which means a negative direction fault,but the transient energy on the opposite end is negative,which indicates that the fault direction is positive.According to these characteristics,an integration criterion identifying fault direction is constructed.In addition,through setting a fixed energy threshold,the faulted line and lightning disturbance can also be discriminated.Simulation results from UHVDC transmission system show the validity of the proposed protection method.
文摘与常规直流相比,永富直流逆变站存在功率全送和功率分送运行方式,而其处于分网接入方式时电网换相换流器高压直流输电(line commutated converter based high voltage directcurrent,LCC-HVDC)系统的交互振荡模式及特征尚不明确。针对这一特殊运行方式,采用模块化建模的思路建立可以反映系统电气/控制回路间交互耦合路径的运动方程模型。在此基础上,依据系统整流侧-逆变侧、正极-负极间的交互耦合路径分解得到影响系统主导模式稳定性的3条扰动传递路径,即整流侧内部自稳性路径、逆变侧内部自稳性路径、双极交互作用致稳性路径。最后,设置不同工况下的案例,量化评估不同作用路径提供的阻尼大小,并通过仿真验证运动方程模型及扰动传递路径分析结果的正确性,为后续研究分网接入方式下LCC-HVDC系统交互振荡模式的阻尼特征提供模型基础。
文摘为研究分网接入方式下电网换相换流器高压直流输电(line commutated converter based high voltage direct current,LCC-HVDC)系统的交互振荡模式及阻尼特征,基于系统的状态空间模型及系列文章(一)建立的运动方程模型,提取了表征逆变侧电气与控制环节强耦合特性的多个弱阻尼交互振荡模式,研究了不同短路比工况下交互振荡模式的变化特征。在此基础上,通过复转矩系数法量化评估了整流侧/逆变侧内部自稳性路径及双极交互作用致稳性路径对主导交互振荡模式阻尼特性的贡献度。结果表明:1)不同短路比工况下交互振荡模式的阻尼比会进行重新分配;2)当逆变侧正负极短路比相差较大时,双极交互作用较弱,正负极系统的稳定性由2个交互振荡模式各自主导,且稳定性特征有所差异;3)当逆变侧正负极短路比相近时,双极间动态交互加强,交互振荡模式会同时主导参与系统两极的稳定性,正负极稳定性特征相似。
文摘The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation.
文摘Renewable sources of energy are being integrated into the power grids due to their economic and environmental merits as compared with the traditional fossil-fuel-fired power generation. However, their significant penetration demands a thorough research in terms of system reliability, that is, security and stability. In this paper, Security Constrained Multi Objective Dynamic Economic Dispatch (SCMODED) problem considering cubic thermal cubic cost function, wind, solar penetration, cubic transmission power losses and cubic emissions cost function as objectives is first formulated. Both HVDC and HVAC lines are included in their formulation. Various approaches like probabilistic load flow (PLF), scenario based method, participation factors and Harmony Search algorithm etc. are employed in the solution process. Security and stability effects of renewable energy (RE) penetration are investigated and analyzed. The simulated results reveal that RE penetration leads to reduced cost and emissions and increased security concerns. Further, there is increased power system instability and hence increased load shedding so as to help the power system attain steady state stability. Inclusion of HVDC lines facilitates rapid and fast control to increase the transient stability limit by the action of the converter ignition angle (CIA) and converter extinction angle (CEA).
文摘The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVDC transmission lines based on correlation analysis is proposed in this paper. In the principle, external fault is equivalent to a positive capacitance model, so the correlation coefficient of the current and voltage derivative is 1;while the internal fault is equivalent to a negative capacitance model, so the correlation coefficient of the current and voltage derivative is -1. Internal faults and external faults can be distinguished by judging the correlation coefficient. Theoretical analysis and PSCAD simulation experiments show that the new principle, which is simple, not affected by transition resistance, control type and line distributed capacitance current, can identify internal faults and external faults reliably and rapidly, having certain practical value.