It has been nearly 50 years since the first glimpse of the relationship between myopia and peripheral refractive errors. According to experiments on both animals and humans, the eyes with hyperopic peripheral vision a...It has been nearly 50 years since the first glimpse of the relationship between myopia and peripheral refractive errors. According to experiments on both animals and humans, the eyes with hyperopic peripheral vision appear to be at higher risk of developing myopia than those with myopic peripheral refractive errors. Despite the first measurement of peripheral refraction being achieved by a modified manual optometer, the concept of emmetropization triggered a rapidly increasing number of studies on peripheral aberrations. Not only the horizontal off-axis aberrations but also the meridional aberrations at different angles are measured by researchers during the development of peripheral aberrations measuring techniques. According to the differences among the working principles, a variety of techniques have been adopted for performing such measurements. The methods developed to realize the high-performance measurement involve the subject cooperating actively by rotating the head or eyes, the rotation of the whole optical path, and the combination of measurements of many light paths. This paper provides a review of the peripheral aberrations measuring techniques and their current status. This article also highlights the development trend of the measuring techniques of peripheral aberrations and practical applications of peripheral aberration measurements, such as the control of the accommodation, the measuring time, and the dynamic range problem of the wavefront sensor. Although wavefront sensing peripheral measurement is widely recognized for its capability to reveal both lower-order aberrations and higher-order aberrations, the efficiency of an autorefractometer is incomparable. The current study reveals that the most widely used peripheral aberration measurement methods are the use of an open field autorefractometer and Hartman-shack wavefront sensor-based techniques.展开更多
The optical wavefront distortion caused by a supersonic flow field around a half model of blunt nose cone was studied in a wind tunnel. A Shack-Hartmann wavefront sensor was used to measure the distorted optical wavef...The optical wavefront distortion caused by a supersonic flow field around a half model of blunt nose cone was studied in a wind tunnel. A Shack-Hartmann wavefront sensor was used to measure the distorted optical wavefront. Interesting optical parameters including the peak variation (PV), root of mean square (RMS) and Strehl ratio were obtained under different test conditions during the experiment. During the establishing process of the flow field in the wind tunnel test section, the wavefront shape was unstable. However after the flow field reached the steady flow state, the wavefront shape kept stable, and the relative error of wavefront aberration was found small. The Shack-Hartmann wavefront sensor developed was proved to be credible in measuring quantitatively the optical phase change of light traveling through the flow field around model window.展开更多
基金the financial support from Science Foundation Ireland (SFI) (No. 15/RP/B3208)‘111’ project by the State Administration of Foreign Experts Affairs and the Ministry of Education of China (No. B07014)。
文摘It has been nearly 50 years since the first glimpse of the relationship between myopia and peripheral refractive errors. According to experiments on both animals and humans, the eyes with hyperopic peripheral vision appear to be at higher risk of developing myopia than those with myopic peripheral refractive errors. Despite the first measurement of peripheral refraction being achieved by a modified manual optometer, the concept of emmetropization triggered a rapidly increasing number of studies on peripheral aberrations. Not only the horizontal off-axis aberrations but also the meridional aberrations at different angles are measured by researchers during the development of peripheral aberrations measuring techniques. According to the differences among the working principles, a variety of techniques have been adopted for performing such measurements. The methods developed to realize the high-performance measurement involve the subject cooperating actively by rotating the head or eyes, the rotation of the whole optical path, and the combination of measurements of many light paths. This paper provides a review of the peripheral aberrations measuring techniques and their current status. This article also highlights the development trend of the measuring techniques of peripheral aberrations and practical applications of peripheral aberration measurements, such as the control of the accommodation, the measuring time, and the dynamic range problem of the wavefront sensor. Although wavefront sensing peripheral measurement is widely recognized for its capability to reveal both lower-order aberrations and higher-order aberrations, the efficiency of an autorefractometer is incomparable. The current study reveals that the most widely used peripheral aberration measurement methods are the use of an open field autorefractometer and Hartman-shack wavefront sensor-based techniques.
文摘The optical wavefront distortion caused by a supersonic flow field around a half model of blunt nose cone was studied in a wind tunnel. A Shack-Hartmann wavefront sensor was used to measure the distorted optical wavefront. Interesting optical parameters including the peak variation (PV), root of mean square (RMS) and Strehl ratio were obtained under different test conditions during the experiment. During the establishing process of the flow field in the wind tunnel test section, the wavefront shape was unstable. However after the flow field reached the steady flow state, the wavefront shape kept stable, and the relative error of wavefront aberration was found small. The Shack-Hartmann wavefront sensor developed was proved to be credible in measuring quantitatively the optical phase change of light traveling through the flow field around model window.