In this paper, we present a magnetocardiogram (MCG) simulation study using the boundary element method (BEM) and based on the virtual heart model and the realistic human volume conductor model. The different contr...In this paper, we present a magnetocardiogram (MCG) simulation study using the boundary element method (BEM) and based on the virtual heart model and the realistic human volume conductor model. The different contributions of cardiac equivalent source models and volume conductor models to the MCG are deeply and comprehensively investigated. The single dipole source model, the multiple dipoles source model and the equivalent double layer (EDL) source model are analysed and compared with the cardiac equivalent source models. Meanwhile, the effect of the volume conductor model on the MCG combined with these cardiac equivalent sources is investigated. The simulation results demonstrate that the cardiac electrophysiological information will be partly missed when only the single dipole source is taken, while the EDL source is a good option for MCG simulation and the effect of the volume conductor is smallest for the EDL source. Therefore, the EDL source is suitable for the study of MCG forward and inverse problems, and more attention should be paid to it in future MCG studies.展开更多
Objectives: We hypothesized that the organisms and their organs or tissues could adapt themselves to the gradual changes of environment for surviving or reducing damage. This study explored whether gradual clamping (G...Objectives: We hypothesized that the organisms and their organs or tissues could adapt themselves to the gradual changes of environment for surviving or reducing damage. This study explored whether gradual clamping (GC) could reduce myocardial ischemia-reperfusion (IR) injury in rat heart. Methods: Twelve rats were randomized to IR group and GC group, then the hearts were isolated and perfused with Langendorff apparatus. Before cardioplegia, the perfusion was stopped abruptly in IR group while slowly with 5-minute in GC group. The hearts were subjected to 30-minute ischemia and 60-minute reperfusion. The left ventricular develop pressure (LVDP) and systolic pressure (LVSP), the maximal rate of the increase and decrease of left ventricular pressure (+dp/dt<sub>max</sub>, ﹣dp/dt<sub>max</sub>) were measured by polygraph system at different time points. The recovery of the variables was expressed as the ratio of these values at individual time point after reperfusion to the baseline respectively. Results: The recovery of LVDP after reperfusion was better than that in IR group (P = 0.034). No significant difference in the recovery of LVSP, +dp/dtmax and ﹣dp/dt<sub>max</sub> between groups was observed. Conclusions: Gradual clamping could improve the recovery of LVDP after IR, suggesting that gradual clamping could reduce myocardial IR injury.展开更多
This paper constructs a concentric ellipsoid torso-heart model by boundary element method and investigates the impacts of model structures on the cardiac magnetic fields generated by both equivalent primary source--a ...This paper constructs a concentric ellipsoid torso-heart model by boundary element method and investigates the impacts of model structures on the cardiac magnetic fields generated by both equivalent primary source--a current dipole and volume currents. Then by using the simulated magnetic fields based on torso-heart model as input, the cardiac current sources--an array of current dipoles by optimal constrained linear inverse method are constructed. Next, the current dipole array reconstruction considering boundaries is compared with that in an unbounded homogeneous medium. Furthermore, the influence of random noise on reconstruction is also considered and the reconstructing effect is judged by several reconstructing parameters.展开更多
Left anterior fascicular block(LAFB) is a heart disease identifiable from an abnormal electrocardiogram(ECG). It has been reported that LAFB is associated with an increased risk of heart failure. Non-specific intr...Left anterior fascicular block(LAFB) is a heart disease identifiable from an abnormal electrocardiogram(ECG). It has been reported that LAFB is associated with an increased risk of heart failure. Non-specific intraventricular conduction delay due to the lesions of the conduction bundles and slow cell to cell conduction has also been considered as another cause of heart failure. Since the location and mechanism of conduction delay have notable variability between individual patients, we hypothesized that the impaired conduction in the ventricular myocardium may lead to abnormal ECGs similar to LAFB ECG patterns. To test this hypothesis, based on a computer model with a three dimensional whole-heart anatomical structure, we simulated the cardiac exciting sequence map and 12-lead ECG caused by the block in the left anterior fascicle and by the slowed conduction velocity in the ventricular myocardium. The simulation results showed that the typical LAFB ECG patterns can also be observed from cases with slowed conduction velocity in the ventricular myocardium. The main differences were the duration of QRS and wave amplitude. In conclusion, our simulations provide a promising starting point to further investigate the underlying mechanism of heart failure with LAFB, which would provide a potential reference for LAFB diagnosis.展开更多
Cardiovascular disease,predominantly coronary heart disease and stroke,leads to high morbidity and mortality not only in developed worlds but also in underdeveloped regions.The dominant pathologic foundation for cardi...Cardiovascular disease,predominantly coronary heart disease and stroke,leads to high morbidity and mortality not only in developed worlds but also in underdeveloped regions.The dominant pathologic foundation for cardiovascular disease is atherosclerosis and,as to coronary heart disease,coronary atherosclerosis and resulting lumen stenosis,even total occlusions.In translational research,several animals,such as mice,rabbits and pigs,have been used as disease models of human atherosclerosis and related cardiovascular disorders.However,coronary lesions are either naturally rare or hard to be fast induced in these models,hence,coronary heart disease induction mostly relies on surgical or pharmaceutical interventions with no or limited primary coronary lesions,thus unrepresentative of human coronary heart disease progression and pathology.In this review,we describe the progress of animal models of coronary heart disease following either spontaneous or diet-accelerated coronary lesions.展开更多
To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease(control group) and 18 spe...To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease(control group) and 18 specimens with severe congenital heart disease(case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels(including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group(P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group(P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.展开更多
Background:Three-dimensional printing technology may become a key factor in transforming clinical practice and in significant improvement of treatment outcomes.The introduction of this technique into pediatric cardiac...Background:Three-dimensional printing technology may become a key factor in transforming clinical practice and in significant improvement of treatment outcomes.The introduction of this technique into pediatric cardiac surgery will allow us to study features of the anatomy and spatial relations of a defect and to simulate the optimal surgical repair on a printed model in every individual case.Methods:We performed the prospective cohort study which included 29 children with congenital heart defects.The hearts and the great vessels were modeled and printed out.Measurements of the same cardiac areas were taken in the same planes and points at multislice computed tomography images(group 1)and on printed 3D models of the hearts(group 2).Pre-printing treatment of the multislice computed tomography data and 3D model preparation were performed according to a newly developed algorithm.Results:The measurements taken on the 3D-printed cardiac models and the tomographic images did not differ significantly,which allowed us to conclude that the models were highly accurate and informative.The new algorithm greatly simplifies and speeds up the preparation of a 3D model for printing,while maintaining high accuracy and level of detail.Conclusions:The 3D-printed models provide an accurate preoperative assessment of the anatomy of a defect in each case.The new algorithm has several important advantages over other available programs.They enable the development of customized preliminary plans for surgical repair of each specific complex congenital heart disease,predict possible issues,determine the optimal surgical tactics,and significantly improve surgical outcomes.展开更多
基金supported by the State Key Development Program for Basic Research of China (Grant Nos. 2007CB512100 and2006CB601007)the National Natural Science Foundation of China (Grant No. 10674006)+2 种基金the National High Technology Research and Development Program of China (Grant No. 2007AA03Z238)China Postdoctoral Science Foundation (Grant No. 20090461376)the Fundamental Research Funds for the Central Universities (Grant No. KYJD09001)
文摘In this paper, we present a magnetocardiogram (MCG) simulation study using the boundary element method (BEM) and based on the virtual heart model and the realistic human volume conductor model. The different contributions of cardiac equivalent source models and volume conductor models to the MCG are deeply and comprehensively investigated. The single dipole source model, the multiple dipoles source model and the equivalent double layer (EDL) source model are analysed and compared with the cardiac equivalent source models. Meanwhile, the effect of the volume conductor model on the MCG combined with these cardiac equivalent sources is investigated. The simulation results demonstrate that the cardiac electrophysiological information will be partly missed when only the single dipole source is taken, while the EDL source is a good option for MCG simulation and the effect of the volume conductor is smallest for the EDL source. Therefore, the EDL source is suitable for the study of MCG forward and inverse problems, and more attention should be paid to it in future MCG studies.
文摘Objectives: We hypothesized that the organisms and their organs or tissues could adapt themselves to the gradual changes of environment for surviving or reducing damage. This study explored whether gradual clamping (GC) could reduce myocardial ischemia-reperfusion (IR) injury in rat heart. Methods: Twelve rats were randomized to IR group and GC group, then the hearts were isolated and perfused with Langendorff apparatus. Before cardioplegia, the perfusion was stopped abruptly in IR group while slowly with 5-minute in GC group. The hearts were subjected to 30-minute ischemia and 60-minute reperfusion. The left ventricular develop pressure (LVDP) and systolic pressure (LVSP), the maximal rate of the increase and decrease of left ventricular pressure (+dp/dt<sub>max</sub>, ﹣dp/dt<sub>max</sub>) were measured by polygraph system at different time points. The recovery of the variables was expressed as the ratio of these values at individual time point after reperfusion to the baseline respectively. Results: The recovery of LVDP after reperfusion was better than that in IR group (P = 0.034). No significant difference in the recovery of LVSP, +dp/dtmax and ﹣dp/dt<sub>max</sub> between groups was observed. Conclusions: Gradual clamping could improve the recovery of LVDP after IR, suggesting that gradual clamping could reduce myocardial IR injury.
基金Project supported by the State Key Development Program for Basic Research of China(Grant No.2006CB601007)the National Natural Science Foundation of China(Grant No.10674006)the National High Technology Research and Development Program of China(Grant No.2007AA03Z238)
文摘This paper constructs a concentric ellipsoid torso-heart model by boundary element method and investigates the impacts of model structures on the cardiac magnetic fields generated by both equivalent primary source--a current dipole and volume currents. Then by using the simulated magnetic fields based on torso-heart model as input, the cardiac current sources--an array of current dipoles by optimal constrained linear inverse method are constructed. Next, the current dipole array reconstruction considering boundaries is compared with that in an unbounded homogeneous medium. Furthermore, the influence of random noise on reconstruction is also considered and the reconstructing effect is judged by several reconstructing parameters.
基金Project supported by the National Natural Science Foundation of China(Nos.61527811 and 61701435)
文摘Left anterior fascicular block(LAFB) is a heart disease identifiable from an abnormal electrocardiogram(ECG). It has been reported that LAFB is associated with an increased risk of heart failure. Non-specific intraventricular conduction delay due to the lesions of the conduction bundles and slow cell to cell conduction has also been considered as another cause of heart failure. Since the location and mechanism of conduction delay have notable variability between individual patients, we hypothesized that the impaired conduction in the ventricular myocardium may lead to abnormal ECGs similar to LAFB ECG patterns. To test this hypothesis, based on a computer model with a three dimensional whole-heart anatomical structure, we simulated the cardiac exciting sequence map and 12-lead ECG caused by the block in the left anterior fascicle and by the slowed conduction velocity in the ventricular myocardium. The simulation results showed that the typical LAFB ECG patterns can also be observed from cases with slowed conduction velocity in the ventricular myocardium. The main differences were the duration of QRS and wave amplitude. In conclusion, our simulations provide a promising starting point to further investigate the underlying mechanism of heart failure with LAFB, which would provide a potential reference for LAFB diagnosis.
文摘Cardiovascular disease,predominantly coronary heart disease and stroke,leads to high morbidity and mortality not only in developed worlds but also in underdeveloped regions.The dominant pathologic foundation for cardiovascular disease is atherosclerosis and,as to coronary heart disease,coronary atherosclerosis and resulting lumen stenosis,even total occlusions.In translational research,several animals,such as mice,rabbits and pigs,have been used as disease models of human atherosclerosis and related cardiovascular disorders.However,coronary lesions are either naturally rare or hard to be fast induced in these models,hence,coronary heart disease induction mostly relies on surgical or pharmaceutical interventions with no or limited primary coronary lesions,thus unrepresentative of human coronary heart disease progression and pathology.In this review,we describe the progress of animal models of coronary heart disease following either spontaneous or diet-accelerated coronary lesions.
基金supported by grants from the National Natural Science Foundation of China(No.81530056 and No.81501494)Hubei Province Health and Family Planning Scientific Research Project(No.WJ2015MB016)Hubei Provincial Key Laboratory of Molecular Imaging Foundation,China(No.02.03.2014-29)
文摘To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease(control group) and 18 specimens with severe congenital heart disease(case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels(including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group(P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group(P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.
基金funded by the Ministry of Science and Higher Education of the Russian Federation as part of the World-Class Research Center Program:Advanced Digital Technologies(Contract No.075-15-2022-311,dated 20.04.2022).
文摘Background:Three-dimensional printing technology may become a key factor in transforming clinical practice and in significant improvement of treatment outcomes.The introduction of this technique into pediatric cardiac surgery will allow us to study features of the anatomy and spatial relations of a defect and to simulate the optimal surgical repair on a printed model in every individual case.Methods:We performed the prospective cohort study which included 29 children with congenital heart defects.The hearts and the great vessels were modeled and printed out.Measurements of the same cardiac areas were taken in the same planes and points at multislice computed tomography images(group 1)and on printed 3D models of the hearts(group 2).Pre-printing treatment of the multislice computed tomography data and 3D model preparation were performed according to a newly developed algorithm.Results:The measurements taken on the 3D-printed cardiac models and the tomographic images did not differ significantly,which allowed us to conclude that the models were highly accurate and informative.The new algorithm greatly simplifies and speeds up the preparation of a 3D model for printing,while maintaining high accuracy and level of detail.Conclusions:The 3D-printed models provide an accurate preoperative assessment of the anatomy of a defect in each case.The new algorithm has several important advantages over other available programs.They enable the development of customized preliminary plans for surgical repair of each specific complex congenital heart disease,predict possible issues,determine the optimal surgical tactics,and significantly improve surgical outcomes.