This paper briefly introduces the collection and recognition of bio-medical sig nals, designs the method to collect FM signals. A detailed discussion on the sys tem hardware, structure and functions is also given. Und...This paper briefly introduces the collection and recognition of bio-medical sig nals, designs the method to collect FM signals. A detailed discussion on the sys tem hardware, structure and functions is also given. Under LabWindows/CVI,the ha rdware and the driver do compatible, the hardware equipment work properly active ly. The paper adopts multi threading technology for real-time analysis and make s use of latency time of CPU effectively, expedites program reflect speed, impro ve s the program to perform efficiency. One threading is collecting data; the other threading is analyzing data. Using the method, it is broaden to analyze the sig nal in real-time. Wavelet transform to remove the main interference in the FM a nd by adding time-window to recognize with BP network; Finally the results of c ollecting signals and BP networks are discussed.8 pregnant women’s signals of F M were collected successfully by using the sensor. The correct of BP network rec ognition is about 83.3% by using the above measure.展开更多
Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under cond...Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under conditions of rest or work,the temporal distances of successive heartbeats are subject to fluctuations,thereby forming the basis of Heart Rate Variability(HRV).In normal conditions,the human is persistently exposed to highly changing and dynamic situational demands.With these demands in mind,HRV can,therefore,be considered as the human organism’s ability to cope with and adapt to continuous situational requirements,both physiologically and emotionally.Fast Fourier Transform(FFT)is used in various physiological signal processing,such as heart rate variability.FFT allows a spectral analysis of HRV and is great help in HRV analysis and interpretation.展开更多
The aim of this paper is to describe and analyse the behaviour of heart rate variability(HRV)during constant-load,high-intensity exercise using a time frequency analysis(Wavelet Transform).Eleven elite cyclists took p...The aim of this paper is to describe and analyse the behaviour of heart rate variability(HRV)during constant-load,high-intensity exercise using a time frequency analysis(Wavelet Transform).Eleven elite cyclists took part in the study(age:18.6±3.0 years;VO_(2max):4.88±0.61 litres·min^(-1)).Initially,all subjects performed an incremental cycloergometer test to determine load power in a constant load-test(379.55±36.02 W;89.0%).HRV declined dramatically from the start of testing(p<0.05).The behaviour of power spectral density within the LF band mirrored that of total energy,recording a significant decrease from the outset LF peaks fell rapidly thereafter,remaining stable until the end of the test.HF-VHF fell sharply in the first 20 to 30 seconds.The relative weighting(%) of HF-VHF was inverted with the onset of fatigue,[1.6%at the start,7.1(p<0.05) at the end of the first phase,and 43.1%(p<0.05) at the end of the test].HF-VHF_(peak) displayed three phases:a moderate initial increase,followed by a slight fall,thereafter increasing to the end of the test.The LF/HF-VHF ratio increased at the start,later falling progressively until the end of the first phase and remaining around minimal values until the end of the test.展开更多
文摘This paper briefly introduces the collection and recognition of bio-medical sig nals, designs the method to collect FM signals. A detailed discussion on the sys tem hardware, structure and functions is also given. Under LabWindows/CVI,the ha rdware and the driver do compatible, the hardware equipment work properly active ly. The paper adopts multi threading technology for real-time analysis and make s use of latency time of CPU effectively, expedites program reflect speed, impro ve s the program to perform efficiency. One threading is collecting data; the other threading is analyzing data. Using the method, it is broaden to analyze the sig nal in real-time. Wavelet transform to remove the main interference in the FM a nd by adding time-window to recognize with BP network; Finally the results of c ollecting signals and BP networks are discussed.8 pregnant women’s signals of F M were collected successfully by using the sensor. The correct of BP network rec ognition is about 83.3% by using the above measure.
文摘Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under conditions of rest or work,the temporal distances of successive heartbeats are subject to fluctuations,thereby forming the basis of Heart Rate Variability(HRV).In normal conditions,the human is persistently exposed to highly changing and dynamic situational demands.With these demands in mind,HRV can,therefore,be considered as the human organism’s ability to cope with and adapt to continuous situational requirements,both physiologically and emotionally.Fast Fourier Transform(FFT)is used in various physiological signal processing,such as heart rate variability.FFT allows a spectral analysis of HRV and is great help in HRV analysis and interpretation.
文摘The aim of this paper is to describe and analyse the behaviour of heart rate variability(HRV)during constant-load,high-intensity exercise using a time frequency analysis(Wavelet Transform).Eleven elite cyclists took part in the study(age:18.6±3.0 years;VO_(2max):4.88±0.61 litres·min^(-1)).Initially,all subjects performed an incremental cycloergometer test to determine load power in a constant load-test(379.55±36.02 W;89.0%).HRV declined dramatically from the start of testing(p<0.05).The behaviour of power spectral density within the LF band mirrored that of total energy,recording a significant decrease from the outset LF peaks fell rapidly thereafter,remaining stable until the end of the test.HF-VHF fell sharply in the first 20 to 30 seconds.The relative weighting(%) of HF-VHF was inverted with the onset of fatigue,[1.6%at the start,7.1(p<0.05) at the end of the first phase,and 43.1%(p<0.05) at the end of the test].HF-VHF_(peak) displayed three phases:a moderate initial increase,followed by a slight fall,thereafter increasing to the end of the test.The LF/HF-VHF ratio increased at the start,later falling progressively until the end of the first phase and remaining around minimal values until the end of the test.