Through the comparison of calcination conditions between cement preclinkering technology and cement precalcining technology,we studied the characteristics of temperature field distribution of cement preclinkering tech...Through the comparison of calcination conditions between cement preclinkering technology and cement precalcining technology,we studied the characteristics of temperature field distribution of cement preclinkering technology systems including cyclone preheater,preclinkering furnace,and rotary kiln.We used numericalsimulation method to obtain data of temperature field distribution.Some results are found by system study.The ratio of tailcoalof cement preclinkering technology is about 70%,and raw mealtemperature can reach 1070 ℃.Shorter L/D kiln type of preclinkering technology can obtain more stable calcining zone temperature.The highest solid temperature of cement preclinkering technology is higher than 80 ℃,and high temperature region(〉1450 ℃)length is 2 times,which is beneficialfor calcining clinker and higher clinker quality.So cement preclinkering technology can obtain more performance temperature filed,which improves both the solid-phase reaction and liquid-phase reaction.展开更多
Observations collected in the Badan Jaran desert hinterland and edge during 19-23 August 2009 and in the Jinta Oasis during 12-16 June 2005 are used to assess three methods for calculating the heat storage of the5-20-...Observations collected in the Badan Jaran desert hinterland and edge during 19-23 August 2009 and in the Jinta Oasis during 12-16 June 2005 are used to assess three methods for calculating the heat storage of the5-20-cm soil layer.The methods evaluated include the harmonic method,the conduction-convection method,and the temperature integral method.Soil heat storage calculated using the harmonic method provides the closest match with measured values.The conduction-convection method underestimates nighttime soil heat storage.The temperature integral method best captures fluctuations in soil heat storage on sub-diurnal timescales,but overestimates the amplitude and peak values of the diurnal cycle.The relative performance of each method varies with the underlying land surface.The land surface energy balance is evaluated using observations of soil heat flux at 5-cm depth and estimates of ground heat flux adjusted to account for soil heat storage.The energy balance closure rate increases and energy balance is improved when the ground heat flux is adjusted to account for soil heat storage.The results achieved using the harmonic and temperature integral methods are superior to those achieved using the conduction-convection method.展开更多
基金Funded by the Major State Basic Research Perelopment Program of China(973 Program)(No.2009CB623102)the Key Fund Project of Sichuan Provincial Department of Education(No.14ZA0086)the Key Fund Project of Professional Scientific Research Innovation Team of Southwest University of Science and Technology(No.14tdfk01)
文摘Through the comparison of calcination conditions between cement preclinkering technology and cement precalcining technology,we studied the characteristics of temperature field distribution of cement preclinkering technology systems including cyclone preheater,preclinkering furnace,and rotary kiln.We used numericalsimulation method to obtain data of temperature field distribution.Some results are found by system study.The ratio of tailcoalof cement preclinkering technology is about 70%,and raw mealtemperature can reach 1070 ℃.Shorter L/D kiln type of preclinkering technology can obtain more stable calcining zone temperature.The highest solid temperature of cement preclinkering technology is higher than 80 ℃,and high temperature region(〉1450 ℃)length is 2 times,which is beneficialfor calcining clinker and higher clinker quality.So cement preclinkering technology can obtain more performance temperature filed,which improves both the solid-phase reaction and liquid-phase reaction.
基金Supported by the National Science and Technology Support Program of China(2012BAH29B03)National(Key) Basic Research and Development(973)Program of China(2009CB421402)
文摘Observations collected in the Badan Jaran desert hinterland and edge during 19-23 August 2009 and in the Jinta Oasis during 12-16 June 2005 are used to assess three methods for calculating the heat storage of the5-20-cm soil layer.The methods evaluated include the harmonic method,the conduction-convection method,and the temperature integral method.Soil heat storage calculated using the harmonic method provides the closest match with measured values.The conduction-convection method underestimates nighttime soil heat storage.The temperature integral method best captures fluctuations in soil heat storage on sub-diurnal timescales,but overestimates the amplitude and peak values of the diurnal cycle.The relative performance of each method varies with the underlying land surface.The land surface energy balance is evaluated using observations of soil heat flux at 5-cm depth and estimates of ground heat flux adjusted to account for soil heat storage.The energy balance closure rate increases and energy balance is improved when the ground heat flux is adjusted to account for soil heat storage.The results achieved using the harmonic and temperature integral methods are superior to those achieved using the conduction-convection method.