期刊文献+
共找到2,400篇文章
< 1 2 120 >
每页显示 20 50 100
Revisiting the theoretical prediction of the explosive performance found by the Trauzl test
1
作者 Ivana Dobrilovic Mario Dobrilovic Muhamed Suceska 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第6期163-174,共12页
The Trauzl lead block test allows the determination of the approximate performance of explosives in blasting applications by measuring the volume increase(expansion)that is produced by the detonation of an explosive c... The Trauzl lead block test allows the determination of the approximate performance of explosives in blasting applications by measuring the volume increase(expansion)that is produced by the detonation of an explosive charge in the cavity of a lead block.In this paper,we reconsider the possibility of interpreting the Trauzl test results in terms of detonation parameters or quantities.The detonation parameters used in the analysis are calculated using the thermochemical code EXPLO5,while the hydrocode AUTODYN is used to simulate the effect of explosive charge density and reaction rate on the results of the Trauzl test.The increase in the volume of the lead block cavity was found to correlate best with the product of the detonation heat and the root of the volume of detonation products.Hydrocode simulation showed that the density of explosive charge and the rate of explosive decomposition affect the dynamics of the interaction of the detonation product and the lead block,and consequently the lead block cavity volume increase. 展开更多
关键词 Trauzl lead block test performance of explosives EXPLO5 AUTODYN Detonation heat
下载PDF
Performance analysis of heat pump based on a new solar air-source heat pump heating system 被引量:2
2
作者 梁彩华 张小松 +1 位作者 朱霞 李秀伟 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期227-231,共5页
To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and p... To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season. 展开更多
关键词 solar energy air-source heat pump heating mode performance SIMULATION
下载PDF
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
3
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Exploring heating performance of gas engine heat pump with heat recovery 被引量:3
4
作者 董付江 刘凤国 +2 位作者 李先庭 尤学一 赵冬芳 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期1931-1936,共6页
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1... In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature. 展开更多
关键词 gas engine heat pump coefficient of performance primary energy ratio heating mode heat recovery
下载PDF
Implementation of heat exchanger performance testing system of heat transfer and flow resistance 被引量:3
5
作者 操瑞兵 陈亚平 +2 位作者 吴嘉峰 董聪 盛艳军 《Journal of Southeast University(English Edition)》 EI CAS 2012年第1期46-51,共6页
A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, co... A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, compressed air, glycol water solution and water as the heating fluids, and air and water as the cooling fluids. The heat transfer performance testing of heat exchangers can be conducted not only for a conventional one heating fluid to one cooling fluid, but also for a compound air cooling heat exchanger with two or three heating fluids in parallel or in series. The control and measurement system is implemented based on a LabVIEW software platform, consisting of the data acquisition and process system, and the automotive operation and control system. By using advanced measuring instruments combined with sound computer software control, the testing system has characteristics of a compact structure, high accuracy, a wide range of testing scope and a friendly operation interface. The uncertainty of the total heat transfer coefficient K is less than 5%. The testing system provides a reliable performance testing platform for designing and developing new heat exchangers. 展开更多
关键词 heat exchanger heat transfer performance testing system LABVIEW
下载PDF
Performance analysis of U-vertical direct-expansion ground-source heat pump 被引量:1
6
作者 杨伟 周晋 张国强 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期209-211,共3页
The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in... The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in the cooling mode and a higher evaporating temperature in the heating mode,and the ground heat exchanger(GHE)in the DX GSHP has a low thermal resistance.Therefore,the coefficient of performance(COP)of the DX GSHP is higher than that of the GSHP.In addition,the system performance of the DX GSHP system is higher than that of the conventional GSHP system because there are no secondary solution loops and water circulating pumps in the DX GSHP system.The experimental energy performance of the DX GSHP system is also investigated based on the actual operational data.The tested DX GSHP system is installed in Xiangtan,China.The U-vertical GHE of the DX GSHP is buried in a water well.The length and the outside nominal diameter of the GHE are 42 m and 12.7 mm,respectively.The experimental results show that the maximum(COP)and the average COP of the DX GSHP system in the heating mode are 5.95 and 4.72,respectively. 展开更多
关键词 direct-expansion ground-source heat pump energy consumption analysis performance
下载PDF
Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3 被引量:3
7
作者 陈成敏 张于峰 +4 位作者 邓娜 马洪亭 张彦所 马丽筠 胡晓微 《Transactions of Tianjin University》 EI CAS 2011年第5期386-390,共5页
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe... Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained. 展开更多
关键词 moderate and high temperature heat pump refrigerant mixture SINGLE-STAGE compression heat pump system coefficient of performance
下载PDF
Heat transfer performance testing of a new type of phase change heat sink for high power light emitting diode 被引量:2
8
作者 XIANG Jian-hua ZHANG Chun-liang +2 位作者 ZHOU Chao LIU Gui-yun ZHOU Wei 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第7期1708-1716,共9页
In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, t... In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, the fabrication process of miniaturized phase change heat sink is investigated, upon which all parts of the heat sink are fabricated including main-body and end-cover of the heat sink, the formation of three-dimensional boiling structures at the evaporation end, the sintering of the wick, and the encapsulation of high power LED phase change heat sink. Subsequently, with the assistance of the developed testing system, heat transfer performance of the heat sink is tested under the condition of natural convection, upon which the influence of thermal load and working medium on the heat transfer performance is investigated. Finally, the heat transfer performance of the developed miniaturized phase change heat sink is compared with that of metal solid heat sink. Results show that the developed miniaturized phase change heat sink presents much better heat transfer performance over traditional metal solid heat sink, and is suitable for the packaging of high power LED. 展开更多
关键词 miniaturized phase change heat sink three-dimensional microgrooves sintered wick heat transfer performance testing
下载PDF
Intelligent prediction on performance of high-temperature heat pump systems using different refrigerants 被引量:1
9
作者 YU Xiao-hui ZHANG Yu-feng +4 位作者 ZHANG Yan HE Zhong-lu DONG Sheng-ming MA Xue-lian YAO Sheng 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第11期2754-2765,共12页
Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2... Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2-based in the HTHP in different running conditions.The results demonstrated the feasibility and reliability of M1 and M2 as new high-temperature refrigerants.Additionally,the exploration and analyses of the support vector machine(SVM)and back propagation(BP)neural network models were made to find a practical way to predict the performance of HTHP system.The results showed that SVM-Linear,SVM-RBF and BP models shared the similar ability to predict the heat capacity and power input with high accuracy.SVM-RBF demonstrated better stability for coefficient of performance prediction.Finally,the proposed SVM model was used to assess the potential of the M1 and M2.The results indicated that the HTHP system using M1 could produce heat at the temperature of 130°C with good performance. 展开更多
关键词 high-temperature heat pump experimental performance support vector machine back propagation neural network performance prediction
下载PDF
Experimental Investigation on the Performance of Heat Pump Operating with Copper and Alumina Nanofluids 被引量:1
10
作者 Faizan Ahmed Waqar Ahmed Khan Jamal Nayfeh 《Computers, Materials & Continua》 SCIE EI 2021年第3期2843-2856,共14页
In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the... In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the heat pump.The nanofluids were used to enhance the heat input to the system by means of providing an external jacket around the evaporator coil.Both the nanofluids were prepared in three volume fractions 1%,2%and 5%.Water was chosen as the base fluid.The performance of the heat pump was assessed by calculating the coefficient of performance of the system when it was operated with and without nanofluid jacket.A significant enhancement in the coefficient of performance was noticed when copper and alumina nanofluids were employed in the system.Also,the coefficient of performance was found to have a direct relationship with the tested volume fractions.For the highest volume fraction of 5%,the performance of the heat pump was found to enhance by 23%with alumina nanofluid,while for copper nanofluid,a very significant enhancement in performance by 72%was observed.Thus,utilizing of nanofluids in heat pumps can be very beneficial towards performance enhancement and the idea can also be extended to other thermal systems such as steam power plant,automobile radiator,industrial heat exchangers and refrigeration systems. 展开更多
关键词 NANOPARTICLES copper nanofluid alumina nanofluid heat pump coefficient of performance
下载PDF
Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan 被引量:2
11
作者 杜红普 孔祥飞 +1 位作者 李敏 齐承英 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1554-1562,共9页
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is... The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability. 展开更多
关键词 ground source heat pump monitoring operation performance
下载PDF
Performance analysis on solar-water compound source heat pump for radiant floor heating system
12
作者 曲世林 马飞 仇安兵 《Journal of Central South University》 SCIE EI CAS 2009年第S1期249-254,共6页
A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water t... A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system. 展开更多
关键词 heat pump SOLAR COMPOUND SOURCE COEFFICIENT of performance
下载PDF
Experimental investigation of effect of refrigerant gases,compressor lubricant and operating conditions on performance of a heat pump
13
作者 AFSHARI Faraz SÖZEN Adnan +2 位作者 KHANLARI Ataollah TUNCER Azim Doğuş ALI Hafiz Muhammad 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3556-3568,共13页
In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des... In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element. 展开更多
关键词 heat pump efficiency coefficient of performance(COP) performance compressor oil charge amount
下载PDF
Experimental Evaluation of the Heat Output/Input and Coefficient of Performance Characteristics of a Chemical Heat Pump in the Periodic Operation of CaCl<sub>2</sub>Hydration
14
作者 Atsuhiro Ichinose Kazuki Kuwata +2 位作者 Takehiro Esaki Takayuki Matsuda Noriyuki Kobayashi 《Journal of Materials Science and Chemical Engineering》 2020年第11期33-42,共10页
We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the... We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump. 展开更多
关键词 Chemical heat pump CaCl2/H2O Hydration Reaction heat pump Cycle Coefficient of performance
下载PDF
Novel Radiation-Adjustable Heating Terminal Based on Flat Heat Pipe Combined with Air Source Heat Pump
15
作者 Yifan Wu Hongli Sun +3 位作者 Mengfan Duan Borong Lin Hengxin Zhao Chaohung Liu 《Engineering》 SCIE EI CAS CSCD 2023年第1期192-207,共16页
The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking c... The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. However, as a major component of space heating, heating terminals might not fit well with ASHP in order to achieve both intermittency and comfort. Therefore, this study proposes a novel radiation-adjustable heating terminal combined with an ASHP to achieve electrification, intermittency, and better thermal comfort. Radiant terminals currently suffer from three major problems: limited maximum heating capacity, inability to freely adapt, and difficulty with combining them with ASHPs. These problems were solved by improving the structural design of the novel terminal (Improvement A–E). Results showed that the maximum heating capacity increased by 23.6% and radiation heat transfer ratio from 10.1% to 30.9% was provided for users with the novel terminal. Further, new flat heat pipe (FHP) design improved stability (compressor oil return), intermittency (refrigerant thermal inertia), and safety (refrigerant leakage risk) by reducing the length of exposed refrigerant pipes. Furthermore, a new phased operation strategy was proposed for the novel terminal, and the adjustability of the terminal was improved. The results can be used as reference information for decarbonizing buildings by electrifying heating terminals. 展开更多
关键词 Novel heating terminal Air-source heat pump Structural impr ovement design Maximum heating capacity Rapid adjustability Room temperature distribution
下载PDF
Heat Transfer Performance and Structural Optimization of a Novel Micro-channel Heat Sink
16
作者 Jianhua Xiang Liangming Deng +3 位作者 Chao Zhou Hongliang Zhao Jiale Huang Sulian Tao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第2期189-200,共12页
With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is pro... With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is promising for the heat dissipation of super-thin electronic equipment.In this study,thermal resistance theoretical model of the micro-channel heat sink was first established.Then,fabrication process of the micro-channel heat sink was introduced.Subsequently,heat transfer performance of the fabricated micro-channel heat sink was tested through the developed testing platform.Results show that the developed micro-channel heat sink has more superior heat dissipation performance over conventional metal solid heat sink and it is well suited for high power LEDs application.Moreover,the micro-channel structures in the heat sink were optimized by orthogonal test.Based on the orthogonal optimization,heat dissipation performance of the micro-channel radiator was further improved. 展开更多
关键词 MICRO-CHANNEL Phase change heat sink heat transfer performance testing Finite element simulation Orthogonal test
下载PDF
Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target
17
作者 Lei LI Le HAN +6 位作者 Pengfei ZI Lei CAO Tiejun XU Nanyu MOU Zhaoliang WANG Lei YIN Damao YAO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第9期194-205,共12页
The divertor target components for the Chinese fusion engineering test reactor(CFETR)and the future experimental advanced superconducting tokamak(EAST)need to remove a heat flux of up to20 MW m-2.In view of such a hig... The divertor target components for the Chinese fusion engineering test reactor(CFETR)and the future experimental advanced superconducting tokamak(EAST)need to remove a heat flux of up to20 MW m-2.In view of such a high heat flux removal requirement,this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology.Rectangular water-cooled channels with a special thermal transfer structure(TTS)are designed in the heat sink to improve the flat-tile divertor target’s heat transfer performance(HTP).The parametric design and optimization methods are applied to study the influence of the TTS variation parameters,including height(H),width(W*),thickness(T),and spacing(L),on the HTP.The research results show that the flat-tile divertor target’s HTP is sensitive to the TTS parameter changes,and the sensitivity is T>L>W*>H.The HTP first increases and then decreases with the increase of T,L,and W*and gradually increases with the increase of H.The optimal design parameters are as follows:H=5.5 mm,W*=25.8 mm,T=2.2 mm,and L=9.7 mm.The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method.A flat-tile divertor mock-up is developed according to the optimized parameters.In addition,high heat flux(HHF)tests are performed on an electron beam facility to further investigate the mock-up HTP.The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m-2under the tungsten tile thickness<5 mm and the flow speed7 m s^(-1).The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by13%and30%compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock,respectively.The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of20 MW m-2of heat load without visible deformation,damage,and HTP degradation.The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only930℃.The flat-tile divertor target’s HTP is greatly improved by the parametric design and optimization method,and is better than the ITER-like monoblock and the flat-tile mock-up for the WEST divertor.This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors. 展开更多
关键词 CFETR heat transfer performance parametric design and optimization HHF tests flat-tile divertor target
下载PDF
Analysis of Thermodynamic Characteristic Changes in Direct Expansion Ground Source Heat Pump Using Hydrofluoroolefins (HFOs) Substituting for HFC-134a
18
作者 Yuefen Gao Honglei Zhao +1 位作者 Yingxin Peng Tony Roskilly 《Energy and Power Engineering》 2013年第2期11-17,共7页
HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be ... HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be beneficial to mitigating climate change. This study aims to find out the thermodynamic characteristics of the direct expansion ground source heat pump system using HFO-1234yf or HFO-1234ze[E] by theoretical calculation. The results indicate that HFO-1234yf system in an actual cycle has the highest COP. HFO-1234yf and HFO-1234ze[E] have such smaller capacity per unit of swept volume that they need larger compression capacity if providing the same heating or cooling loads. For a given unit when HFC-134a is replaced with HFO-1234yf or HFO-1234ze[E], the capacity will decrease. More refrigerant charge is required in the HFO-1234yf or HFO-1234ze[E] system. The results also present that more refrigerant charge is required in the cooling mode than in the heating mode. 展开更多
关键词 Direct EXPANSION Ground Source heat pump (DXGSHP) THERMODYNAMIC performance HFO-1234YF HFO-1234ze[E] HFC-134A
下载PDF
Field Investigation and Comparison Analysis of Low-Grade Heat Pump Technologies in Building Space Heating Projects
19
作者 Yanxue Li Weijun Gao +3 位作者 Xiaoyi Zhang Wenya Xu Yingjun Ruan Yinzhong Wang 《Energy Engineering》 EI 2022年第1期63-81,共19页
The building sector contributes a large ratio of final energy consumption,and improving building energy efficiency is expected to play a significant role in mitigating its carbon dioxide emission.Herein,we collected t... The building sector contributes a large ratio of final energy consumption,and improving building energy efficiency is expected to play a significant role in mitigating its carbon dioxide emission.Herein,we collected the on-site measurement data to investigate the techno-economic performances of different heat pump types that exist in building space heating projects in Qingdao,China.An in-depth analysis revealed the temperature variations of measured low-grade heat sources over the whole heating supply period,and urban sewage water shows high stable heat energy quality compared with seawater and geothermal heat resources.Operational behaviors including cycling inlet and outlet temperature of the selected heat pumps were illustrated,and analysis evaluated detailed effects of operational parameters on energy efficiency performances.Then the relationship between COPs distributions of heat pumps and operational conditions was examined further,and the positive effect of the rising temperature of heat sources on energy efficiency improvement of heat pump is highlighted when the heating supply temperature is higher.Furthermore,we analyzed the economic and carbon emission performance of the heat pump system,and results show that electricity price plays a vital role in the lifespan energy cost saving potential,and the heat pump could serve as a promising approach in reducing CO_(2) related to the building space heating.Finally,we recommended suggestions for improving the overall energy efficiency and cost competitiveness of decentralized heat pump systems for building space heating. 展开更多
关键词 On-site measurement heat pumps heating supply operational performance
下载PDF
Research on Operation of Electrothermal Integrated Energy System Including Heat Pump and Thermal Storage Units Based on Capacity Planning
20
作者 Taihong Liu Dingchen Wu +4 位作者 Fei Xu Panpan Song Mingshan Wei Jian Wu Xiaochun Bai 《Energy Engineering》 EI 2021年第3期535-548,共14页
In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing... In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing power grid operation.In this paper,an electrothermal integrated energy system including heat pump and thermal storage units was proposed.The scheduling model was based on the load data and the output characteristics of power units,each power unit capacity was programmed without constraints,and the proposed scheduling model was compared with the traditional combined heat and power scheduling model.Results showed that the investment and pollutant discharge of the system was reduced respectively.Wind power was fully absorbed.Compared with the traditional thermal power unit,the proportion of the output was significantly decreased by the proposed model.The proposed system could provide a new prospect for wind power absorption and environment protection. 展开更多
关键词 Electrothermal integrated energy system capacity planning thermal storage unit heat pump
下载PDF
上一页 1 2 120 下一页 到第
使用帮助 返回顶部