期刊文献+
共找到10,645篇文章
< 1 2 250 >
每页显示 20 50 100
Increasing the Efficiency and Level of Environmental Safety of Pro-Environmental City Heat Supply Technologies by Low Power Nuclear Plants
1
作者 Vladimir Kravchenko Igor Kozlov +3 位作者 Volodymyr Vashchenko Iryna Korduba Andrew Overchenko Serhii Tsybytovskyi 《World Journal of Nuclear Science and Technology》 CAS 2024年第2期107-117,共11页
In connection with the current prospect of decarbonization of coal energy through the use of small nuclear power plants (SNPPs) at existing TPPs as heat sources for heat supply to municipal heating networks, there is ... In connection with the current prospect of decarbonization of coal energy through the use of small nuclear power plants (SNPPs) at existing TPPs as heat sources for heat supply to municipal heating networks, there is a technological need to improve heat supply schemes to increase their environmental friendliness and efficiency. The paper proves the feasibility of using the heat-feeding mode of ASHPs for urban heat supply by heating the network water with steam taken from the turbine. The ratio of electric and thermal power of a “nuclear” combined heat and power plant is given. The advantage of using a heat pump, which provides twice as much electrical power with the same heat output, is established. Taking into account that heat in these modes is supplied with different potential, the energy efficiency was used to compare these options. To increase the heat supply capacity, a scheme with the use of a high-pressure heater in the backpressure mode and with the heating of network water with hot steam was proposed. Heat supply from ASHPs is efficient and environmentally friendly even in the case of significant remoteness of heat consumers. 展开更多
关键词 Low-Capacity Nuclear power Plants Environmental Friendliness of the thermal power Generation Mode Heat Generation Condensation Mode Heat Supply
下载PDF
The changing process and trend of ground temperature around tower foundations of Qinghai-Tibet Power Transmission line 被引量:3
2
作者 YanLi Xie QiHao Yu +2 位作者 YanHui You ZhongQiu Zhang TingTao Gou 《Research in Cold and Arid Regions》 CSCD 2019年第1期13-20,共8页
After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing proce... After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change. 展开更多
关键词 Qinghai-Tibet power Transmission line tower FOUNDATION ground temperature change CHARACTERISTIC TREND
下载PDF
Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant 被引量:4
3
作者 Xiaoxiao Li Sam Duniam +3 位作者 Hal Gurgenci Zhiqiang Guan Anand Veeraragavan 侯恩哲 《建筑节能》 CAS 2017年第5期113-113,共1页
Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid a... Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid area,natural draft dry cooling tower is a promising choice.To develop the experimental studies on small cooling tower,a 20 m high natural draft dry cooling tower with fully instrumented measurement system was established by the Queensland Geothermal Energy Centre of Excellence.The performance of this cooling tower was measured with the constant heat input of 600 kW and 840 kW and with ambient temperature ranging from 20 ℃ to 32 ℃.The cooling tower numerical model was refined and validated with the experimental data.The model of 1 MW concentrating solar thermal supercritical CO2 power cycle was developed and integrated with the cooling tower model.The influences of changing ambient temperature and the performance of the cooling tower on efficiency of the power system were simulated.The differences of the mechanism of the ambient temperature effect on Rankine cycle and supercritical CO2 Brayton cycle were analysed and discussed. 展开更多
关键词 tower draft SUPERCRITICAL Rankine LIKELY AMBIENT refined irradiation RENEWABLE Queensland
下载PDF
A New Principle of Fault Identification of on the Same Tower Based on Traveling Wave Reactive Powers
4
作者 Hao Wu Ruikai Ye +2 位作者 Xingxing Dong Kunjian Yu Zhengwei Chang 《Journal of Power and Energy Engineering》 2019年第7期50-70,共21页
In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based ... In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based on the reactive powers of traveling wave is proposed. With the implementation of S-transform, the initial traveling wave reactive powers are calculated and the change characteristics of reactive power under different fault conditions are studied. The protection criterion is constructed by analyzing the ratio of the reactive powers of the same end on double-circuit transmission lines and the ratio of the reactive powers at both ends on the same line. According to the ratio of reactive power on the same side of the line and both ends of the same line, it is possible to identify whether the faults of the double-circuit line of the same tower occurred in or out of the protection zone. A large number of simulation results show that the protection performance is sensitive and reliable, and quick to respond. The criterion is simple and is basically not affected by fault initial angles, fault types, and transitional resistances. 展开更多
关键词 Double-Circuit Transmission Line on the SAME tower TRAVELING Wave Reactive power S-TRANSFORM Fault Identification
下载PDF
Thermo-economic Investigation of an Enhanced Geothermal System Organic Rankine Cycle and Combined Heating and Power System
5
作者 WANG Lingbao BU Xianbiao LI Huashan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2021年第6期1958-1966,共9页
As a potentially viable renewable energy, Enhanced Geothermal Systems(EGSs) extract heat from hot dry rock(HDR) reservoirs to produce electricity and heat, which promotes the progress towards carbon peaking and carbon... As a potentially viable renewable energy, Enhanced Geothermal Systems(EGSs) extract heat from hot dry rock(HDR) reservoirs to produce electricity and heat, which promotes the progress towards carbon peaking and carbon neutralization. The main challenge for EGSs is to reduce the investment cost. In the present study, thermo-economic investigations of EGS projects are conducted. The effects of geofluid mass flow rate, wellhead temperature and loss rate on the thermo-economic performance of the EGS organic Rankine cycle(ORC) are studied. A performance comparison between EGS-ORC and the EGS combined heating and power system(CHP) is presented. Considering the CO_(2)emission reduction benefits, the influence of carbon emission trading price on the levelized cost of energy(LCOE) is also presented. It is indicated that the geofluid mass flow rate is a critical parameter in dictating the success of a project. Under the assumed typical working conditions, the LCOE of EGS-ORC and EGS-CHP systems are 24.72 and 16.1 cents/k Wh, respectively. Compared with the EGS-ORC system, the LCOE of the EGS-CHP system is reduced by 35%. EGS-CHP systems have the potential to be economically viable in the future. With carbon emission trading prices of 12.76 USD/ton, the LCOE can be reduced by approximately 8.5%. 展开更多
关键词 enhanced geothermal system organic Rankine cycle combined heating and power system thermo-economic investigation carbon emission reduction
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
6
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
Characteristics of divertor heat flux distribution with an island divertor configuration on the J-TEXT tokamak
7
作者 Yutong YANG Yunfeng LIANG +8 位作者 Wei YAN Shuangbao SHU Jiankun HUA Song ZHOU Qinghu YANG Jinlong GUO Ziyang JIN Wei XIE the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期9-17,共9页
On J-TEXT,the temporal evolution of heat flux distribution on the high-field side(HFS)divertor plate has been measured by an infrared(IR)camera during the plasma operation with an island divertor configuration.In expe... On J-TEXT,the temporal evolution of heat flux distribution on the high-field side(HFS)divertor plate has been measured by an infrared(IR)camera during the plasma operation with an island divertor configuration.In experiments,the island divertor configuration is an edge magnetic island chain structure surrounded by stochastic layers,which can be induced by resonant magnetic perturbations(RMPs).The experimental results show that the heat flux distribution on the HFS target plate depends significantly on the edge magnetic topology.Furthermore,the impact of hydrogen fueling using supersonic molecular beam injection(SMBI)on the divertor heat flux distributions is studied on J-TEXT with an island divertor configuration.It has been observed that power detachment can be achieved when the radiation front approaches the last closed flux surface(LCFS)after each SMBI pulse.This result may provide a method of access for divertor detachment on a fusion device with a three-dimensional(3D)boundary magnetic structure. 展开更多
关键词 infrared camera island divertor heat flux SMBI power detachment
下载PDF
3D electromagnetic simulation of the coupling characteristics and double-stub Ferrite tuners impedance matching for EAST ICRH four-strap antenna
8
作者 Hua ZHOU Dan DU +4 位作者 Zhongshi YANG KSAITO Qingxi YANG Wei ZHANG Guojian NIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期32-44,共13页
A program developed with COMSOL software integrates EAST four-strap antenna coupling with the double-stub Ferrite tuners(FT)impedance matching,obtaining physical quantities crucial for predicting the overall performan... A program developed with COMSOL software integrates EAST four-strap antenna coupling with the double-stub Ferrite tuners(FT)impedance matching,obtaining physical quantities crucial for predicting the overall performance of the ion cyclotron resonance heating(ICRH)antenna and matching system.These quantities encompass S-matrix,port complex impedance,reflection coefficients,electric field and voltage distribution,and optimal matching settings.In this study,we explore the relationship between S-matrix,reflection coefficients,port complex impedance,and frequency.Then,we analyze the impact of Faraday screens placement position and transparency,the distance from the Faraday screen(FS)to the current straps(CS),the relative distance between ports,and the characteristic impedance of the transmission line on the coupling characteristic impedance of the EAST ICRH system.Finally,we simulate the electric field distribution and voltage distribution of the EAST ICRH system for plasma heating with double-stub FT impedance matching.Using optimized parameters,the coupling power of the ICRH system can be approximately doubled.The results present herein may offer guidance for the design of high-power,long-pulse operation ICRH antenna systems. 展开更多
关键词 ion cyclotron resonance heating antenna impedance matching system coupling power S-MATRIX EAST
下载PDF
Performance of Gas-Steam Combined Cycle Cogeneration Units Influenced by Heating Network Terminal Steam Parameters
9
作者 Guanglu Xie Zhimin Xue +5 位作者 Bo Xiong Yaowen Huang Chaoming Chen Qing Liao Cheng Yang Xiaoqian Ma 《Energy Engineering》 EI 2024年第6期1495-1519,共25页
The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and p... The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and power system multidimensionally based on the operating characteristics of the cogeneration units,the hydraulic and thermodynamic characteristics of the heating network,and the energy loads.Taking a steam network supported by a gas-steam combined cycle cogeneration system as the research case,the interaction effect among the source-side prime movers,the heating networks,and the terminal demand thermal parameters were investigated based on the designed values,the plant testing data,and the validated simulation.The operating maps of the gas-steam combined cycle cogeneration units were obtained using THERMOFLEX,and the minimum source-side steam parameters of the steam network were solved using an inverse solution procedure based on the hydro-thermodynamic coupling model.The cogeneration operating maps indicate that the available operating domain considerably narrows with the rise of the extraction steam pressure and flow rate.The heating network inverse solution demonstrates that the source-side steam pressure and temperature can be optimized from the originally designed 1.11 MPa and 238.8°C to 1.074 MPa and 191.15°C,respectively.Under the operating strategy with the minimum source-side heating parameters,the power peak regulation depth remarkably increases to 18.30%whereas the comprehensive thermal efficiency decreases.The operation under the minimum source-side heating steam parameters can be superior to the originally designed one in the economy at a higher price of the heating steam.At a fuel price of$0.38/kg and the power to fuel price of 0.18 kg/(kW·h),the critical price ratio of heating steam to fuel is 119.1 kg/t.The influence of the power-fuel price ratio on the economic deviation appears relatively weak. 展开更多
关键词 Gas-steam combined cycle cogeneration of heating and power steam network inverse problem operating performance
下载PDF
Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources
10
作者 Tianyu Zhou Liang Hao +2 位作者 Xin Xu Meng Si Lian Zhang 《Energy Engineering》 EI 2024年第1期145-168,共24页
This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.Th... This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.The simulated heat source temperature(SHST)in this work was set from 39.51°C to 48.60°C by the simulated heat source module.The influence of load percentage of simulated heat source(LPSHS)between 50%and 70%,the rotary valve opening(RVO)between 20%and 100%,the resistive load between 36Ωand 180Ωor the no-load of the generator,as well as the autumn and winter ambient temperature on the system performance were studied.The results showed that the stability of the system was promoted when the generator had a resistive load.The power generation(PG)and generator speed(GS)of the system in autumn were better than in winter,but the expander pressure ratio(EPR)was lower than in winter.Keep RVO unchanged,the SHST,the mass flow rate(MFR)of the working medium,GS,and the PG of the system increased with the increasing of LPSHS for different generator resistance load values.When the RVO was 60%,LPSHS was 70%,the SHST was 44.15°C and the resistive load was 72Ω,the highest PG reached 15.11 W.Finally,a simulation formula was obtained for LPSHS,resistance load,and PG,and its correlation coefficient was between 0.9818 and 0.9901.The formula can accurately predict the PG.The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792,and the relative error was within±5%. 展开更多
关键词 ORC load percentage of simulated heat source resistive load rotary valve opening power generation
下载PDF
Improving the performance of a thermoelectric power system using a flat-plate heat pipe 被引量:8
11
作者 Suchen Wu Yiwen Ding +1 位作者 Chengbin Zhang Dehao Xu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期44-53,共10页
A gravitational flat-plate heat pipe is designed and fabricated in this paper to serve as a heat spreader to diffuse the local heat source to the hot side of the thermoelectric power module.Based on this, an experimen... A gravitational flat-plate heat pipe is designed and fabricated in this paper to serve as a heat spreader to diffuse the local heat source to the hot side of the thermoelectric power module.Based on this, an experimental test for the thermoelectric power generation system is conducted to study the influences of the heat spreader on the temperature uniformity and power generation performance when exposing to a local heat source.In addition,the effects of the heating power, inclination angle, and local heat source size on the power generation performance of the thermoelectric power module using a flat-plate heat pipe as a heat spreader are examined and compared with that using a metal plate.The results indicate that the gravitational flat-plate heat pipe has considerable advantages over the metal plate in the temperature uniformity.The superiority of temperature uniformity in the improvement of power generation performance for the thermoelectric power system using a heat pipe is demonstrated.Particularly, the heat pipe shows good adaptability to placement mode and the local heat source size, which is beneficial to the application in the thermoelectric power generation. 展开更多
关键词 theRMOELECTRIC HEAT PIPE HEAT SPREADER power generation
下载PDF
Recent advance on the efficiency at maximum power of heat engines 被引量:9
12
作者 Tu Zhan-Chun 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期36-45,共10页
This review reports several key advances on the theoretical investigations of efficiency at maximum power of heat engines in the past five years. The analytical results of efficiency at maximum power for the Curzon-Ah... This review reports several key advances on the theoretical investigations of efficiency at maximum power of heat engines in the past five years. The analytical results of efficiency at maximum power for the Curzon-Ahlborn heat engine, the stochastic heat engine constructed from a Brownian particle, and Feynman's ratchet as a heat engine are presented. It is found that: the efficiency at maximum power exhibits universal behavior at small relative temperature differences; the lower and the upper bounds might exist under quite general conditions; and the problem of efficiency at maximum power comes down to seeking for the minimum irreversible entropy production in each finite-time isothermal process for a given time. 展开更多
关键词 effciency at maximum power heat engine UNIVERSALITY BOUNDS
下载PDF
In-Situ Preparation and Thermal Shock Resistance of Mullite-Cordierite Heat Tube Material for Solar Thermal Power 被引量:6
13
作者 徐晓虹 MA Xionghua +3 位作者 WU Jianfeng CHEN Ling XU Tao ZHANG Mengqi 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第3期407-412,共6页
In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sint... In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sintering using a-Al203, Suzhou kaolin, talc, and feldspar as starting materials. The important parameter for solar thermal transfer tube such as water absorption (W), bulk density (Db), and the mechanical properties were investigated. The phase composition and microstructure of the composite ceramics were analyzed by XRD and SEM. The experimental results show that the B3 sintered at 1 300 ℃ and holding for 3 h has an optimum thermal shock resistance. The bending strength loss rate of B3 is only 2% at 1 100℃ by air quenching-strength test and the sample can endure 30 times thermal shock cycling, and the water absorption, the bulk density and the bending strength are 0.32%, 2.58 g·cm-3, and 125.59 MPa respectively. The XRD analysis indicated that the phase compositions of the sample were mullite, cordierite, corundum, and spinel. The SEM images illustrate that the cordierite is prismatic grain and the mullite is nano rod, showing a good thermal shock resistance for composite ceramics as potential solar thermal power material. 展开更多
关键词 solar thermal power generation heat transfer tube MULLITE-CORDIERITE composite ceramic
下载PDF
New thermal optimization scheme of power module in solid-state amplifier 被引量:3
14
作者 Lie-Peng Sun Zhen-Yu Yuan +5 位作者 Cheng Zhang Xian-Bo Xu Jun-Gang Miao Jian-Hua Zhang Long-Bo Shi Yuan He 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第4期143-149,共7页
The new 1 kW power module for ADS project needs the optimization of cooling design including water flow and tunnel layout, and the water flow of three tons per hour was chosen to be a goal for a 20 kW power source.Acc... The new 1 kW power module for ADS project needs the optimization of cooling design including water flow and tunnel layout, and the water flow of three tons per hour was chosen to be a goal for a 20 kW power source.According to analysis from the insertion and integrated loss, about 24 modules were integrated into the rated power. Thus, every module has a cooling flow of 2.1 L/min for RF heat load and power supply loss, which is very hard to achieve if no special consideration and techniques. A new thermal simulation method was introduced for thermal analysis of cooling plate through CST multi-physics suite,especially for temperature of power LDMOS transistor.Some specific measures carried out for the higher heat transfer were also presented in this paper. 展开更多
关键词 RF system SOLID-STATE AMPLIFIER power MODULE HEAT TRANSFER COEFFICIENT
下载PDF
Performance analysis and improvement of geothermal binary cycle power plant in oilfield 被引量:4
15
作者 李太禄 朱家玲 张伟 《Journal of Central South University》 SCIE EI CAS 2013年第2期457-465,共9页
In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that refle... In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that reflects both the technical and economic performances was put forward and used as the objective function. An organic Rankine cycle (ORC) was analyzed through the energetic and exergetic analyses, and the reasons for low efficiency were pinpointed. Results indicate that geothermal water directly transferring heat to the working fluid reduces energy dissipation and increases cycle efficiencies. The net power output with an internal heat exchanger (IHE) is averagely 5.3% higher than that without an IHE. R601a and R601 can be used to replace R123 for geothermal water below 110℃. Moreover, the modified ORC dramatically outperforms the actual one. 展开更多
关键词 geothermal power generation organic Rankine cycle energetic and exergetic analyses OILFIELD internal heat exchanger
下载PDF
Analysis of Wind Power Assessment Based on the WRF Model 被引量:1
16
作者 LI Ji-Hang GUO Zhen-Hai +2 位作者 WANG Hui-Jun LI Ji-Hang WANG Hui-Jun 《Atmospheric and Oceanic Science Letters》 CSCD 2014年第2期126-131,共6页
Assessing wind energy is a key step in selecting a site for a wind farm. The accuracy of the assessment is essential for the future operation of the wind farm. There are two main methods for assessing wind power: one ... Assessing wind energy is a key step in selecting a site for a wind farm. The accuracy of the assessment is essential for the future operation of the wind farm. There are two main methods for assessing wind power: one is based on observational data and the other relies on mesoscale numerical weather prediction(NWP). In this study, the wind power of the Liaoning coastal wind farm was evaluated using observations from an anemometer tower and simulations by the Weather Research and Forecasting(WRF) model, to see whether the WRF model can produce a valid assessment of the wind power and whether the downscaling process can provide a better evaluation. The paper presents long-term wind data analysis in terms of annual, seasonal, and diurnal variations at the wind farm, which is located on the east coast of Liaoning Province. The results showed that, in spring and summer, the wind speed, wind direction, wind power density, and other main indicators were consistent between the two methods. However, the values of these parameters from the WRF model were significantly higher than the observations from the anemometer tower. Therefore, the causes of the differences between the two methods were further analyzed. There was much more deviation in the original material, National Centers for Environmental Prediction(NCEP) final(FNL) Operational Global Analysis data, in autumn and winter than in spring and summer. As the region is vulnerable to cold-air outbreaks and windy weather in autumn and winter, and the model usually forecasted stronger high or low systems with a longer duration, the predicted wind speed from the WRF model was too large. 展开更多
关键词 wind power assessment anemometer tower data WRF model variance analysis
下载PDF
Evaporative Cooling Applied in Thermal Power Plants:A Review of the State-ofthe-Art and Typical Case Studies 被引量:1
17
作者 Tiantian Liu Huimin Pang +7 位作者 Suoying He Bin Zhao Zhiyu Zhang Jucheng Wang Zhilan Liu Xiang Huang Yuetao Shi Ming Gao 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2229-2265,共37页
A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-coo... A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption. 展开更多
关键词 Direct evaporative cooling cooling tower cooling performance wet media nozzle spray thermal power plants
下载PDF
Technical and Economic Aspects and Experience from 6 Years of Operating the Technology Using the Waste Heat from the Exhaust Gases of Heat Sources and 3 Years of Operating a Heating Plant in an Autonomous, Island Regime 被引量:1
18
作者 Imrich Discantiny 《Journal of Geological Resource and Engineering》 2019年第2期39-44,共6页
This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion p... This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion process in heat & power plants, cogeneration units, etc., which burn the gaseous fuel, primarily natural gas, or methane, biogas, geothermal gas, or other gaseous mixtures containing hydrogen. The solution proposes a more effective and non-traditional use of gaseous fuel for heating, the flue gases of which are processed in order to extract additional utilisable heat, with potential elimination of CO2 from them. Deploying of the heating plant in an island regime (OFF-GRID) enables definition of the benefits brought by the 3 years of operational experience and presents visions for the future offering the possibility to utilise the support energy services at the municipal as well as regional level. 展开更多
关键词 NATURAL GAS (NG) liquefied NATURAL GAS (LNG) liquefied propane GAS (LPG) combined HEAT & power (CHP) renewable energy sources (RES) waste HEAT recovery (WHR) international GAS union (IGU)
下载PDF
Effect of Substructure on the Thermoelectric Power of aβ-Quenched ZrCrFe Alloy
19
作者 DerekO.Northwood 孙喜臣 《Rare Metals》 SCIE EI CAS CSCD 1993年第2期110-116,共7页
β-quenching a Zr-1.15 wt%Cr-0.10 wt%Fe alloy produces a martensitic or a Widmanst(a|¨)tten transforma- tion morphology,or a mixture of the two,depending on the cooling rate.For the Widmanst(a|¨)tten struc... β-quenching a Zr-1.15 wt%Cr-0.10 wt%Fe alloy produces a martensitic or a Widmanst(a|¨)tten transforma- tion morphology,or a mixture of the two,depending on the cooling rate.For the Widmanst(a|¨)tten structure,or the mixed martensitic-Widmanst(a|¨)itten structure,a grain boundary phase is observed at most prior-β grain boundaries.X-ray line broadening analysis and the thermoelectric power(TEP)measurements of these quenched samples show that not only the solubility of alloying elements in α-Zr matrix,but also substructure (microstrain,crystallite size and dislocation density)have an effect on TEP.Thus,TEP measurements are very well suited for following the structural transformations taking place in Zr alloys during fabrication. 展开更多
关键词 ZrCrFe alloy SUBSTRUCTURE Heat treatment thermoelectric power
下载PDF
Application of Solid Oxide Fuel Cell-Auxiliary Power Unit on Different Trucks in Northeast China
20
作者 周苏 王士嘉 《Journal of Donghua University(English Edition)》 EI CAS 2015年第4期565-570,共6页
A diesel engine of conventional trucks has a low efficiency under the idling condition,leading to a high cost for heating or cooling in the cab during night. The solution to this problem will have great significance o... A diesel engine of conventional trucks has a low efficiency under the idling condition,leading to a high cost for heating or cooling in the cab during night. The solution to this problem will have great significance on energy conservation and emission reduction. A new auxiliary power unit of solid oxide fuel cell( SOFCAPU) with high efficiency solves this problem perfectly. Heat pump air conditioner is considered as a promising device for the application of SOFC-APU with a high cooling and heating efficiency. To make a quantitative analysis for the application of SOFC-APU,a model is built in Matlab / Simulink. The diesel engine model and SOFC-APU model are fitted based on some experimental data of SOFC-APU and diesel engine during the idling operation. An analysis of the application of SOFC-APU on different trucks in Northeast China is comprehensively made,including efficiency and emission. 展开更多
关键词 diesel engine TRUCK heating and cooling power emissions AUXILIARY power unit of solid oxide fuel cell(SofC-APU)
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部