期刊文献+
共找到7,382篇文章
< 1 2 250 >
每页显示 20 50 100
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
1
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Thermal Experience in an Era of Low Exergy Domestic Heating Systems
2
作者 Chris Tweed 《Journal of Civil Engineering and Architecture》 2023年第4期161-172,共12页
Existing theories of thermal comfort are largely blind to the way heat is delivered to spaces.Field studies,however,show that people create and enjoy thermal conditions that lie outside conventional definitions of com... Existing theories of thermal comfort are largely blind to the way heat is delivered to spaces.Field studies,however,show that people create and enjoy thermal conditions that lie outside conventional definitions of comfort-the thermal experience itself is valued-some of which are tied to particular ways of delivering heat.The concept“exergy”can be used to describe the quality of heat energy and its ability to provide warmth.A shift from fossil fuels towards renewable sources heralds a new era of space heating consisting mainly of low exergy sources,such as heat pumps.This marks a major turning point in the history of domestic heating.This paper begins by discussing variations in domestic thermal environments before considering new forms of low carbon heating.Later sections analyse the way in which these systems deliver heat within people’s homes and consider the implications for thermal experience,comfort and energy consumption. 展开更多
关键词 Thermal experience heating systems alliesthesia low energy design
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
3
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Assessment of tobacco heating system 2.4 on osteogenic differentiation of mesenchymal stem cells and primary human osteoblasts compared to conventional cigarettes 被引量:1
4
作者 Romina H Aspera-Werz Sabrina Ehnert +5 位作者 Monja Müller Sheng Zhu Tao Chen Weidong Weng Johann Jacoby Andreas K Nussler 《World Journal of Stem Cells》 SCIE CAS 2020年第8期841-856,共16页
BACKGROUND Cigarette smoking(CS)is the most common method of consuming tobacco.Deleterious effects on bone integrity,increased incidence of fractures,and delayed fracture healing are all associated with CS.Over 150 of... BACKGROUND Cigarette smoking(CS)is the most common method of consuming tobacco.Deleterious effects on bone integrity,increased incidence of fractures,and delayed fracture healing are all associated with CS.Over 150 of the 6500 molecular species contained in cigarette smoke and identified as toxic compounds are inhaled by CS and,via the bloodstream,reach the skeletal system.New technologies designed to develop a reduced-risk alternative for smokers are based on electronic nicotine delivery systems,such as e-cigarettes and tobacco heating systems(THS).THS are designed to heat tobacco instead of burning it,thereby reducing the levels of harmful toxic compounds released.AIM To examine the effects of THS on osteoprogenitor cell viability and function compared to conventional CS.METHODS Human immortalized mesenchymal stem cells(n=3)and primary human preosteoblasts isolated from cancellous bone samples from BG Unfall Klinik Tübingen(n=5)were osteogenically differentiated in vitro with aqueous extracts generated from either the THS 2.4“IQOS”or conventional“Marlboro”cigarettes for up to 21 d.Cell viability was analyzed using resazurin conversion assay(mitochondrial activity)and calcein-AM staining(esterase activity).Osteogenic differentiation and bone cell function were evaluated using alkaline phosphatase(AP)activity,while matrix formation was analyzed through alizarin red staining.Primary cilia structure was examined by acetylatedα-tubulin immunofluorescent staining.Free radical production was evaluated with 2’,7’-dichlorofluoresceindiacetate assay.RESULTS Our data clearly show that THS is significantly less toxic to bone cells than CS when analyzed by mitochondrial and esterase activity(P<0.001).No significant differences in cytotoxicity between the diverse flavors of THS were observed.Harmful effects from THS on bone cell function were observed only at very high,non-physiological concentrations.In contrast,extracts from conventional cigarettes significantly reduced the AP activity(by two-fold)and matrix mineralization(four-fold)at low concentrations.Additionally,morphologic analysis of primary cilia revealed no significant changes in the length of the organelle involved in osteogenesis of osteoprogenitor cells,nor in the number of ciliated cells following THS treatment.Assessment of free radical production demonstrated that THS induced significantly less oxidative stress than conventional CS in osteoprogenitor cells.CONCLUSIONTHS was significantly less harmful to osteoprogenitor cells during osteogenesisthan conventional CS. Additional studies are required to confirm whether THS isa better alternative for smokers to improve delays in bone healing followingfracture. 展开更多
关键词 Primary human osteoblast Cigarette smoke Tobacco heating system Mesenchymal stem cells Electronic nicotine delivery systems BONE
下载PDF
Case Study:Promoting Sustainable Energy Greenhouse Heating Systems to Small-Scale Local Farms
5
作者 Jeremy Ferrell Ok-Youn Yu Heiyoung Kim 《Journal of Agricultural Science and Technology(A)》 2020年第4期165-180,共16页
Biomass energy generated from livestock manure,other agricultural by-products and food waste can be an affordable greenhouse-heating energy source for those seeking lower energy costs.Appalachian State University,Nort... Biomass energy generated from livestock manure,other agricultural by-products and food waste can be an affordable greenhouse-heating energy source for those seeking lower energy costs.Appalachian State University,North Carolina(NC),USA,has built a 6.1 m×9.1 m greenhouse,called the“Nexus”to test the integrated sustainable energy heating system for growing season extension with less energy cost.This is done by using on-farm biomass resources/wastes such as agricultural waste and wood chips to produce energy coupled with solar water heating to store and supplement required thermal inputs.Growing season extension with heated greenhouses increases the availability of local food throughout the year,expands available markets and increases farmers’profits.Nexus includes an above ground 5,680-L water storage tank and an aquaculture pond.It is supported by a small-scale pyrolysis system,an anaerobic digestion system,solar thermal and compost heating.The preliminary result showed that compared to a conventional space heating system,about 30%of energy was saved to keep the greenhouse temperature available for growing by radiation from the water storage tank.The main purpose of this study was to test the proposed greenhouse heating systems developed at Nexus by implementing pilot systems on two local farms.Pyrolysis and solar thermal system in conjunction with heat storage and delivery system for each farm were built and tested in order to demonstrate how to reduce greenhouse energy use.This paper describes the results of the case study,which showed significant energy savings that can promote the resource-limited farmers’interest. 展开更多
关键词 GREENHOUSE sustainable energy farms heating system small-scale.
下载PDF
Effect of Different Heating Systems in Cucumber Production Greenhouses in Varamin Region on Crop Yield, Volume and Cost of Gas Consumed
6
作者 Majid Rashidi 《Journal of Environmental Science and Engineering(B)》 2020年第5期206-214,共9页
This research was conducted to study the effect of different heating systems in cucumber production greenhouses in Varamin region,Tehran province,Iran on crop yield,volume and cost of gas consumed.Three types of conve... This research was conducted to study the effect of different heating systems in cucumber production greenhouses in Varamin region,Tehran province,Iran on crop yield,volume and cost of gas consumed.Three types of conventional heating systems,namely the central heating system(including boiler+hot water pipes),gas heater system(including double-walled tank+blower)and traditional furnace system(including ignition chamber+torch+pipes carrying a mixture of hot air and flammable gases)were studied during two consecutive periods of greenhouse cucumber cultivation in the cold season(from January to June),and average values of crop yield,volume and cost of gas consumed were determined separately.Results of the study indicated that the central heating system with the highest crop yield(295 tžha^-1),and the lowest volume(100,000 m3žha^-1)and cost(210,000,000 Rialsžha^-1)of gas consumed was the best and most suitable heating system for greenhouses producing cucumbers in Varamin region and other regions with the same and similar climate as well as regions with active greenhouses in the cold season. 展开更多
关键词 GREENHOUSE heating systems greenhouse cucumber crop yield gas consumed Varamin Iran
下载PDF
Effects of Different Heating Systems on Cucumber Yield in Greenhouses and Cost and Gas Volume Consumed in Varamin Region
7
作者 Majid Rashidi Karim Arabsalmani Behnam Zand 《Journal of Agricultural Science and Technology(B)》 2020年第6期341-349,共9页
This research was conducted to investigate the effects of three heating systems on cucumber yield,and cost and gas volume consumed in greenhouses located in Varamin region,Tehran province,Iran.Conventional heating sys... This research was conducted to investigate the effects of three heating systems on cucumber yield,and cost and gas volume consumed in greenhouses located in Varamin region,Tehran province,Iran.Conventional heating systems used in the greenhouses are:central heating system(including boiler+hot water pipes),gas heater system(including double-walled tank+blower)and traditional furnace system(including ignition chamber+torch+pipes carrying a mixture of hot air and flammable gases).The study was carried out for two consecutive cucumber cultivation periods from January to June.Average values of crop yield,volume and cost of gas consumed were determined separately for each heating system.Results of the study indicated that the central heating system with the highest crop yield(295 t/ha),and the lowest volume(100,000 m^(3)/ha)and cost(840 USD/ha)of gas consumed was the best and most suitable heating system for greenhouses producing cucumbers in Varamin region and other regions with the same and similar climate as well as regions with active greenhouses in the cold season. 展开更多
关键词 GREENHOUSE heating systems greenhouse cucumber crop yield gas consumed Varamin Iran
下载PDF
Passive Heating Systems:A Case Study in a Brazilian Mountainous Region
8
作者 Ana Clara L.Pereira Ana Lúcia T.S.da Motta +2 位作者 Bruno B.F.da Costa Priscilla C.P.F.de Oliveira Thiago V.Miranda 《Journal of Civil Engineering and Architecture》 2019年第11期676-685,共10页
The study of thermal comfort in the built environment is of great relevance since it stimulates the development of more sustainable buildings suited to the local climate and able to meet the human need for well-being.... The study of thermal comfort in the built environment is of great relevance since it stimulates the development of more sustainable buildings suited to the local climate and able to meet the human need for well-being.The objective of this research was to develop,construct and test a passive heating system adaptable to existing buildings,reducing the need for major interventions and increasing thermal comfort in the indoor environment.The adopted methodological approach was a case study in a single-family residence located in the Brazilian city of Petrópolis,a mountainous region with a humid subtropical climate and a rigorous winter.The proposed passive heating system is totally isolated,thus mitigating air infiltration and promoting increase of temperature in the internal environment through the absorption of solar energy and greenhouse effect.This kind of solution is especially interesting for residents of this region,since most of the city buildings are not adequately prepared to handle low temperatures.Thus,given local climatic conditions,residents need to spend a lot of money on the acquisition and operation of electric or gas heating systems.The results indicated that the developed system,in fact,increased the temperature of the studied room when compared to an adjacent room,which did not receive the device.The findings of this paper,therefore,provide a valuable reference for experts and practitioners in the selection of heating systems to be used in cold regions,and proved that passive systems can provide thermal comfort at the same time that optimize the interaction of the building with the local ecosystem. 展开更多
关键词 Passive heating systems thermal comfort bioclimatic architecture sustainable buildings
下载PDF
Operation Performance of Central Solar Heating System with Seasonal Storage Water Tank in Harbin 被引量:2
9
作者 YE Ling1,JIANG Yi-qiang1,YAO Yang1,ZHANG Shi-cong2(1.Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,Harbin,Heilongjiang 150090,China 2.Institute of Built Environment and Energy Efficiency,China Academy of Building Research,Beijing 100013,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期111-114,共4页
This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in t... This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was followed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which decreases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition,the relationship between the solar collector efficiency and storage water temperature is also obtained,it decreases quickly with increasing storing water temperature,and then increases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world. 展开更多
关键词 CENTRAL solar heating system with SEASONAL storage(CSHSSS) simulation system efficiency STORAGE water tank VILLA
下载PDF
Tunable biasing magnetic field design of ferrite tuner for ICRF heating system in EAST 被引量:1
10
作者 徐曼曼 宋云涛 +4 位作者 陈根 赵燕平 毛玉周 刘广 彭振 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第11期82-91,共10页
Ion cyclotron range of frequency(ICRF) heating has been used in tokamaks as one of the most successful auxiliary heating tools and has been adopted in the EAST. However, the antenna load will fluctuate with the chan... Ion cyclotron range of frequency(ICRF) heating has been used in tokamaks as one of the most successful auxiliary heating tools and has been adopted in the EAST. However, the antenna load will fluctuate with the change of plasma parameters in the ICRF heating process. To ensure the steady operation of the ICRF heating system in the EAST, fast ferrite tuner(FFT) has been carried out to achieve real-time impedance matching. For the requirements of the FFT impedance matching system, the magnet system of the ferrite tuner(FT) was designed by numerical simulations and experimental analysis, where the biasing magnetic circuit and alternating magnetic circuit were the key researched parts of the ferrite magnet. The integral design goal of the FT magnetic circuit is that DC bias magnetic field is 2000 Gs and alternating magnetic field is±400 Gs. In the FTT, E-type magnetic circuit was adopted. Ferrite material is Nd Fe B with a thickness of 30 mm by setting the working point of Nd Fe B, and the ampere turn of excitation coil is 25 through the theoretical calculation and simulation analysis. The coil inductance to generate alternating magnetic field is about 7 m H. Eddy-current effect has been analyzed, while the magnetic field distribution has been measured by a Hall probe in the medium plane of the biasing magnet. Finally, the test results show the good performance of the biasing magnet satisfying the design and operating requirements of the FFT. 展开更多
关键词 EAST ICRF heating ferrite tuner biasing magnet
下载PDF
Numerical Study of Thermal Performance of Phase Change Material Energy Storage Floor in Solar Water Heating System
11
作者 ZENG Ruo-lang,WANG Xin,ZHANG Yin-ping,DI Hong-fa,ZHANG Qun-li(Department of Building Science,Tsinghua University,Beijing 100084,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期141-145,共5页
The conventional solar heating floor system contains a big water tank to store energy in the day time for heating at night,which takes much building space and is very heavy.In order to reduce the water tank volume eve... The conventional solar heating floor system contains a big water tank to store energy in the day time for heating at night,which takes much building space and is very heavy.In order to reduce the water tank volume even to cancel the tank,a novel structure of integrated water pipe floor heating system using shape-stabilized phase change materials(SSPCM)for thermal energy storage was developed.A numerical model was developed to analyze the performance of SSPCM floor heating system under the intermittent heating condition,which was verified by our experimental data.The thermal performance of the heating system and the effects of various factors on it were analyzed numerically.The factors including phase transition temperature,heat of fusion,thermal conductivity of SSPCM and thermal conductivity of the decoration material were analyzed.The results show that tm and kd are the most import influencing factors on the thermal performance of SSPCM floor heating system,since they determine the heat source temperature and thermal resistance between SSPCM plates and indoor air,respectively.Hm should be large to store enough thermal energy in the day time for nighttimes heating.The effects of kp can be ignored in this system.The SSPCM floor heating system has potential of making use of the daytime solar energy for heating at night efficiently in various climates when its structure is properly designed. 展开更多
关键词 phase CHANGE material energy STORAGE SOLAR water heating
下载PDF
Energy-saving potential analysis for teaching building with intermittent heating system in university of Tianjin
12
作者 何乐 孙贺江 《Journal of Central South University》 SCIE EI CAS 2009年第S1期111-117,共7页
An energy consumption analysis based on the heating characteristic of a building with central heat exchanger in a university of Tianjin was done,and the feasibility of intermittent heating with variable speed pumps wa... An energy consumption analysis based on the heating characteristic of a building with central heat exchanger in a university of Tianjin was done,and the feasibility of intermittent heating with variable speed pumps was discussed. By comparing various methods of energy consumption analysis,a modified Bin method based on the weather data in Tianjin was adopted. The heat consumption of the buildings under intermittent heating mode was calculated and compared with continuous heating mode,the result shows that intermittent heating can reduce energy consumption for 1 941 759 kW·h,save standard coal for 341 t,and reduce pump power consumption for 72 679 kW·h annually. Intermittent operation by means of varying the pump frequency not only leads to savings in fuel consumption and reduction in pollutant emissions,but also reduces operating costs significantly and it is an ideal energy-saving method. By analyzing the results,the recommendations of heating operation regulation and the transformation of pipe network were proposed separately to different kinds of buildings in colleges,such as laboratory building,teaching building. 展开更多
关键词 BIN method INTERMITTENT heating METEOROLOGICAL parameters ENERGY-SAVING of buildings
下载PDF
Value analysis of district heating system with gas-fired peak load boiler in secondary network
13
作者 郑雪晶 穆振英 《Journal of Central South University》 SCIE EI CAS 2009年第S1期178-182,共5页
In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fu... In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fuels of the system,including coal and gas,would cause different environmental impacts. Meanwhile,the reliability of the heating networks would be changed because the peak load regulating boiler could work as a standby heat source. A model for assessment of heating system was established by value analysis to optimize this kind of system. Energy consumption,greenhouse gas emission,pollution emission and system reliability were selected as functional assessment indexes in the model. Weights of each function were determined by analytical hierarchy process (AHP) and experts consultation. Life cycle cost was used as the cost in the model. A real case as an example was discussed to obtain the optimal base load ratio. The result shows that the optimal base load ratio of the case is 0.77. 展开更多
关键词 DISTRICT heating VALUE analysis base LOAD RATIO SECONDARY network
下载PDF
Performance analysis on solar-water compound source heat pump for radiant floor heating system
14
作者 曲世林 马飞 仇安兵 《Journal of Central South University》 SCIE EI CAS 2009年第S1期249-254,共6页
A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water t... A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system. 展开更多
关键词 heat PUMP SOLAR COMPOUND SOURCE COEFFICIENT of performance
下载PDF
A Polarizer with Sinusoidal Grooves in the Electron Cyclotron Resonance Heating System of the HL-2A Tokamak
15
作者 张国庆 Kazunobu NAGASAKl +4 位作者 周俊 王贺 黄梅 陈罡宇 饶军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第5期619-624,共6页
Theoretical calculation and experimental results for a polarizer with sinusoidal grooves used in the electron cyclotron resonance heating (ECRH) system of the HL-2A tokamak are presented. The calculation is based on... Theoretical calculation and experimental results for a polarizer with sinusoidal grooves used in the electron cyclotron resonance heating (ECRH) system of the HL-2A tokamak are presented. The calculation is based on an integral method developed in the vector theory of diffraction gratings, and the polarization characteristics obtained with a low-power test are in good agreement with the numerical calculated results. With the polarizer assembled in a miter bend in the ECRH transmission line, pure ordinary mode (O-mode) and extraordinary mode (X-mode) polarized waves are also expected in the high-power experiment, depending on the polarizer rotation angle and the toroidal injection angle of the electron cyclotron (EC) wave beam. Second-harmonic X-mode experiments were successfully explored in HL-2A. Experimental result revealed that the electron temperature increased from 0.8 keV (Ohmic heating phase) to 1.5 keV (second X-mode heating phase). 展开更多
关键词 POLARIZER electron cyclotron resonance heating vector integral method ordi-nary mode extraordinary mode
下载PDF
Ion Cyclotron Resonance Heating System on EAST
16
作者 王磊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期465-467,共3页
Ion cyclotron resonance heating (ICRH) system which will provide at least than 10 MW heating power, with a frequency range from 25 MHz to 100 MHz, is being built up for the EAST. The system includes high-power and w... Ion cyclotron resonance heating (ICRH) system which will provide at least than 10 MW heating power, with a frequency range from 25 MHz to 100 MHz, is being built up for the EAST. The system includes high-power and wide-frequency radio amplifier, transmission line as well as resonant double loop (RDL) antenna. As a part of this system a sub-ICRH system unit with a ultimate output power of 2.5 MW was set up and employed for heating experiment. The maximum of the launched power reached 200 kW in 2008. 展开更多
关键词 ion cyclotron resonance heating radio amplifier transmission line ANTENNA
下载PDF
Experimental Research of the Radiator Thermal Performance Test Equipment and Its Application in Heating System
17
作者 Lian Zhang Linjun Fan +3 位作者 Xin Xu Baowen Cao Heng Zhang Lihong Song 《Energy Engineering》 EI 2021年第2期399-410,共12页
Radiator thermal performance test equipment plays a key role in the processing of developing a new type of heat radiator and its application products.The precise of temperature controlling,temperature measuring andflo... Radiator thermal performance test equipment plays a key role in the processing of developing a new type of heat radiator and its application products.The precise of temperature controlling,temperature measuring andflow measuring are the vital factors for a radiator thermal performance test equipment.Based on the above back-ground,this paper improves the measurement and control system of radiator thermal performance test equip-ment,which improves the accuracy of the radiator thermal performance test equipment.This paper also optimizes the software and hardware system simultaneously so as to improve the precision of the auto-test system of test equipment.Theflow rate ranges from 175 kg/h to 178 kg/h under different conditions.The average is 176.5 kg/h and the deviation rates are from 1.62%to 1.97%.The heat produced under various conditions is different.The maximum is 4.3 kW and the minimum is 4.2 kW for condition 1,the maximum is 3.3 kW and the minimum is 3.2 kW for condition 2 and the maximum is 1.95 kW and the minimum is 1.89 kW for condition 3.However,the deviation rate is about 2.9%,which shows that the device has high stability and high precision.This paper studies a new electronic heat cost allocate meter test method by radiator thermal performance test equipment at the same time.This paper tests temperature changes through four measures points and gets a result appeared as a heat backup which should be avoided when using in the test of electronic heat cost allocate meter.Some experiences and references could be gained for further research in the heating system from this test and research. 展开更多
关键词 Electronic heat cost allocate meter RADIATOR precise control heating
下载PDF
Experimental Study of Solar-Assisted Heating System
18
作者 Jieting Wei Yang Liu Yu Gu 《Energy and Power Engineering》 2013年第4期151-156,共6页
Solar heating is a new energy saving technology. This paper studies the operating characteristics of solar-assisted heating system in Changchunarea, the changes of the indoor temperature with the conditions of solar-a... Solar heating is a new energy saving technology. This paper studies the operating characteristics of solar-assisted heating system in Changchunarea, the changes of the indoor temperature with the conditions of solar-assisted heating system .By analyzing these operating data we can see solar-assisted heating to meet the requirements of the indoor temperature and save energy. 展开更多
关键词 SOLAR ASSISTED heating ENERGY SAVING
下载PDF
Analysis of Double and Single Sided Induction Heating Systems by Layer Theory Approach
19
作者 Layth Jameel Buni Qaseer 《Journal of Electromagnetic Analysis and Applications》 2010年第7期403-410,共8页
The iterative layer theory approach is applied to the analysis of double sided and single sided induction heating systems for continuous heating of thin metal strips. The excitation is transverse to the direction of s... The iterative layer theory approach is applied to the analysis of double sided and single sided induction heating systems for continuous heating of thin metal strips. The excitation is transverse to the direction of strip motion and can be three phase or single phase. Nonmagnetic as well as ferromagnetic strips are employed. The important system parameters, namely, strip resistance, reactance, induced power and electromagnetic force are introduced. Accuracy of the method is verified with measurement of practical induction heating system together with comparison to numerical and analytical methods. 展开更多
关键词 EDDY CURRENTS Electromagnetic ANALYSIS Energy CONVERSION INDUCTION heating
下载PDF
Magnetic Oil Thermal Behavior under Electromagnetic Induction for Energy Efficient Heating System Design
20
作者 Ahmet Kucukkomurler Ramazan Selver 《Journal of Electromagnetic Analysis and Applications》 2010年第5期297-300,共4页
This study describes thermal behavior of magnetic lubricant oil under electromagnetic induction. Experimental set up include oil pump, oil tank, induction heating unit, and heat exchanger. It is a closed loop system w... This study describes thermal behavior of magnetic lubricant oil under electromagnetic induction. Experimental set up include oil pump, oil tank, induction heating unit, and heat exchanger. It is a closed loop system where the oil pump circulates oil through oil tank to the system, at the same time induction heating unit heats up to the heat exchanger where the lubricant oil thermal behavior is examined. The unit has been largely studied and tested both magnetic and regular motor oil in a laboratory environment and promising results have been obtained for an actual indoor floor to space heating system design. 展开更多
关键词 Electromagnetic INDUCTION Electroheat LUBRICANT OIL Heat Transfer Fluid Dynamics INDUCTION HEATED Iron Radiant HEATER
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部