Transient electromagnetic method (TEM),as a non-seismic geophysical exploration mainstream electromagnetic method,is widely used in oil,gas,mineral and other underground resources exploration areas. The coil sensor is...Transient electromagnetic method (TEM),as a non-seismic geophysical exploration mainstream electromagnetic method,is widely used in oil,gas,mineral and other underground resources exploration areas. The coil sensor is generally used to collect data. In view of the problems of incomplete information of the abnormal body and the data loss in the existing TEM single-component coil sensor,a three-component TEM coil sensor is designed. By analyzing the relationship between sensor sensitivity and coil structure parameters,the coil structure and turns are designed. By analyzing the frequency response characteristics of the TEM magnetic field sensor,the signal distortion is reduced by using the under-damped matching mode. By analyzing the distribution of various noise sources of the magnetic sensor,the appropriate amplifier is selected to reduce the background noise. Finally,a three-component TEM induction magnetic field sensor is designed. The weight of the sensor is controlled at 3.2 kg and the working frequency is 10 mHz-10 kHz. The background noises of X and Y components probably keep in 1.5×10^-8 V/ Hz and sensitivities are 8.4 and 9.8 nT/s,respectively,the background noise of vertical component is 2.1× 10^-7 V/ Hz and sensitivity is 18.5 nT/s. Compared with the existing single-component TEM receiving magnetic field sensor,the designed sensor realizes the signal acquisition of three components. Without too much increase in volume and total weight,it improves the sensitivity of the sensor and reduces the background noise,thus the signal-to-noise ratio (SNR) of the signal is improved.展开更多
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ...For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.展开更多
In order to calibrate electrical instruments and generate a constant magnetic field, a novel design method for square Helmholtz coil is proposed. According to the superposition principle in electromagnetics, the theor...In order to calibrate electrical instruments and generate a constant magnetic field, a novel design method for square Helmholtz coil is proposed. According to the superposition principle in electromagnetics, the theory of the square Helmholtz coil is established, and the design method is verified by Matlab calculation. Compared with conventional circular Helmholtz coil, the novel square one is with a larger uniform region. Simulation work is conducted in Maxwell, and the distribution of the magnetic field is obtained. The results demonstrate the validation of the applied calculation method of the proposed Helmholtz model. The space utilization rate η is used to make a comparison between the square and circular coils for the uniform region. The square Helmholtz coil is fabricated, the length of a single square coil is 1.5 m, and the amplitude of the magnetic field is controlled by the current. The GSM-19 T proton magnetometer is used to measure the amplitude of the magnetic field generated by the square Helmholtz coil. Experimental results indicate that a wide-range variable uniform magnetic field from 0 to 120 μT is generated in the center of Helmholtz coils.展开更多
为了提高电子束偏转扫描频率和磁场均匀性,采用Helmholtz空心线圈结构设计了一种低感抗电子枪偏转扫描线圈。采用ANSYS有限元分析软件对偏转扫描线圈的电磁场分布进行仿真,并采用高斯计对线圈内部的电磁场进行了测量,仿真结果与实际测...为了提高电子束偏转扫描频率和磁场均匀性,采用Helmholtz空心线圈结构设计了一种低感抗电子枪偏转扫描线圈。采用ANSYS有限元分析软件对偏转扫描线圈的电磁场分布进行仿真,并采用高斯计对线圈内部的电磁场进行了测量,仿真结果与实际测量值基本吻合,线圈内部的磁感应强度大小和电磁场分布的均匀性可以满足电子束高频偏转扫描的要求。实际扫描试验表明,该线圈实现了两点电子束高频偏转扫描,扫描频率可达30 k Hz。展开更多
Magnetometric resistivity(MMR)method is a new way to detect dam leakage.The coil sensor is generally used to collect data in geophysical exploration methods.Given the characteristics of accurate vector data requiremen...Magnetometric resistivity(MMR)method is a new way to detect dam leakage.The coil sensor is generally used to collect data in geophysical exploration methods.Given the characteristics of accurate vector data requirements and high sensitivity requirement,a three-component MMR air-core coil sensor is designed.Through the analysis of sensor sensitivity and coil structure parameters,the coil structure and turn number are designed.By analyzing the noise source of the sensor,a suitable amplifier is selected to reduce the background noise of the system.Through the analysis of the three-component non-orthogonal angles,the parameters of the non-orthogonal angles of the coils are corrected.Finally,a three-component MMR induction magnetic field sensor is designed.The volume of the sensor is controlled at 0.027 m 3.The background noise of X、Y and Z are 5.030435 nV/Hz@380 Hz and magnetic field sensitivities are 0.18995 pT/Hz@380 Hz.The three channels have good consistency,and the three-component nonorthogonal angles correction error of three components is controlled within 0.2%.展开更多
文摘Transient electromagnetic method (TEM),as a non-seismic geophysical exploration mainstream electromagnetic method,is widely used in oil,gas,mineral and other underground resources exploration areas. The coil sensor is generally used to collect data. In view of the problems of incomplete information of the abnormal body and the data loss in the existing TEM single-component coil sensor,a three-component TEM coil sensor is designed. By analyzing the relationship between sensor sensitivity and coil structure parameters,the coil structure and turns are designed. By analyzing the frequency response characteristics of the TEM magnetic field sensor,the signal distortion is reduced by using the under-damped matching mode. By analyzing the distribution of various noise sources of the magnetic sensor,the appropriate amplifier is selected to reduce the background noise. Finally,a three-component TEM induction magnetic field sensor is designed. The weight of the sensor is controlled at 3.2 kg and the working frequency is 10 mHz-10 kHz. The background noises of X and Y components probably keep in 1.5×10^-8 V/ Hz and sensitivities are 8.4 and 9.8 nT/s,respectively,the background noise of vertical component is 2.1× 10^-7 V/ Hz and sensitivity is 18.5 nT/s. Compared with the existing single-component TEM receiving magnetic field sensor,the designed sensor realizes the signal acquisition of three components. Without too much increase in volume and total weight,it improves the sensitivity of the sensor and reduces the background noise,thus the signal-to-noise ratio (SNR) of the signal is improved.
基金Project supported by the“Strategic Priority Research Program(B)”of the Chinese Academy of Sciences(Grant No.XDB04020200)the Shanghai Municipal Science and Technology Commission Project,China(Grant No.15DZ1940902)
文摘For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.
基金The National Natural Science Foundation of China(No.61327803)
文摘In order to calibrate electrical instruments and generate a constant magnetic field, a novel design method for square Helmholtz coil is proposed. According to the superposition principle in electromagnetics, the theory of the square Helmholtz coil is established, and the design method is verified by Matlab calculation. Compared with conventional circular Helmholtz coil, the novel square one is with a larger uniform region. Simulation work is conducted in Maxwell, and the distribution of the magnetic field is obtained. The results demonstrate the validation of the applied calculation method of the proposed Helmholtz model. The space utilization rate η is used to make a comparison between the square and circular coils for the uniform region. The square Helmholtz coil is fabricated, the length of a single square coil is 1.5 m, and the amplitude of the magnetic field is controlled by the current. The GSM-19 T proton magnetometer is used to measure the amplitude of the magnetic field generated by the square Helmholtz coil. Experimental results indicate that a wide-range variable uniform magnetic field from 0 to 120 μT is generated in the center of Helmholtz coils.
文摘为了提高电子束偏转扫描频率和磁场均匀性,采用Helmholtz空心线圈结构设计了一种低感抗电子枪偏转扫描线圈。采用ANSYS有限元分析软件对偏转扫描线圈的电磁场分布进行仿真,并采用高斯计对线圈内部的电磁场进行了测量,仿真结果与实际测量值基本吻合,线圈内部的磁感应强度大小和电磁场分布的均匀性可以满足电子束高频偏转扫描的要求。实际扫描试验表明,该线圈实现了两点电子束高频偏转扫描,扫描频率可达30 k Hz。
文摘Magnetometric resistivity(MMR)method is a new way to detect dam leakage.The coil sensor is generally used to collect data in geophysical exploration methods.Given the characteristics of accurate vector data requirements and high sensitivity requirement,a three-component MMR air-core coil sensor is designed.Through the analysis of sensor sensitivity and coil structure parameters,the coil structure and turn number are designed.By analyzing the noise source of the sensor,a suitable amplifier is selected to reduce the background noise of the system.Through the analysis of the three-component non-orthogonal angles,the parameters of the non-orthogonal angles of the coils are corrected.Finally,a three-component MMR induction magnetic field sensor is designed.The volume of the sensor is controlled at 0.027 m 3.The background noise of X、Y and Z are 5.030435 nV/Hz@380 Hz and magnetic field sensitivities are 0.18995 pT/Hz@380 Hz.The three channels have good consistency,and the three-component nonorthogonal angles correction error of three components is controlled within 0.2%.