The cubic stiffness force model(CSFM)and Bouc-Wen model(BWM)are introduced and compared innovatively.The unknown coefficients of the nonlinear models are identified by the genetic algorithm combined with experiments.B...The cubic stiffness force model(CSFM)and Bouc-Wen model(BWM)are introduced and compared innovatively.The unknown coefficients of the nonlinear models are identified by the genetic algorithm combined with experiments.By fitting the identified nonlinear coefficients under different excitation amplitudes,the nonlinear vibration responses of the system are predicted.The results show that the accuracy of the BWM is higher than that of the CSFM,especially in the non-resonant region.However,the optimization time of the BWM is longer than that of the CSFM.展开更多
Objective:A novel technique was explored using an airbag-selective portal vein blood arrester that circumvents the need for an intraoperative assessment of anatomical variations in patients with complex intrahepatic s...Objective:A novel technique was explored using an airbag-selective portal vein blood arrester that circumvents the need for an intraoperative assessment of anatomical variations in patients with complex intrahepatic space-occupying lesions.Methods:Rabbits undergoing hepatectomy were randomly assigned to 4 groups:intermittent portal triad clamping(PTC),intermittent portal vein clamping(PVC),intermittent portal vein blocker with an airbag-selective portal vein blood arrester(APC),and without portal blood occlusion(control).Hepatic ischemia and reperfusion injury were assessed by measuring the 7-day survival rate,blood loss,liver function,hepatic pathology,hepatic inflammatory cytokine infiltration,hepatic malondialdehyde levels,and proliferating cell nuclear antigen levels.Results:Liver damage was substantially reduced in the APC and PVC groups.The APC animals exhibited transaminase levels similar to or less oxidative stress damage and inflammatory hepatocellular injury compared to those exhibited by the PVC animals.Bleeding was significantly higher in the control group than in the other groups.The APC group had less bleeding than the PVC group because of the avoidance of portal vein skeletonization during hepatectomy.Thus,more operative time was saved in the APC group than in the PVC group.Moreover,the total 7-day survival rate in the APC group was higher than that in the PTC group.Conclusion:Airbag-selective portal vein blood arresters may help protect against hepatic ischemia and reperfusion injury in rabbits undergoing partial hepatectomy.This technique may also help prevent liver damage in patients requiring hepatectomy.展开更多
BACKGROUND Hem-o-lok clips are typically used to control the cystic duct and vessels during laparoscopic cholecystectomy(LC)and common bile duct exploration for stones in the bile duct and gallbladder.Here,we report a...BACKGROUND Hem-o-lok clips are typically used to control the cystic duct and vessels during laparoscopic cholecystectomy(LC)and common bile duct exploration for stones in the bile duct and gallbladder.Here,we report a unique example of Hem-o-lok clip movement towards the duodenal bulb after LC,appearing as a submucosal tumor(SMT).Additionally,we provide initial evidence of gradual and evolving endoscopic manifestations of Hem-o-lok clip migration to the duodenal bulb wall and review the available literature.CASE SUMMARY A 72-year-old man underwent LC for gallstones,and Hem-o-lok clips were used to ligate both the cystic duct and cystic artery.Esophagogastroduodenoscopy(EGD)2 years later revealed an SMT-like lesion in the duodenal bulb.Due to the symptomatology,the clinical examination did not reveal any major abnormalities,and the patient was followed up as an outpatient.A repeat EGD performed 5 months later revealed an SMT-like lesion in the duodenal bulb with raised edges and a central depression.A third EGD was conducted,during which a Hem-o-lok clip was discovered connected to the front side of the duodenum.The clip was extracted easily using biopsy forceps,and no complications occurred.Two months after the fourth EGD,the scar was surrounded by normal mucosa.CONCLUSION Clinicians should be aware of potential post-LC complications.Hem-o-lok clips should be removed if symptomatic.展开更多
文摘The cubic stiffness force model(CSFM)and Bouc-Wen model(BWM)are introduced and compared innovatively.The unknown coefficients of the nonlinear models are identified by the genetic algorithm combined with experiments.By fitting the identified nonlinear coefficients under different excitation amplitudes,the nonlinear vibration responses of the system are predicted.The results show that the accuracy of the BWM is higher than that of the CSFM,especially in the non-resonant region.However,the optimization time of the BWM is longer than that of the CSFM.
基金supported by the Hainan Provincial Natural Science Foundation of China(No.821QN0982 and No.2019RC373)。
文摘Objective:A novel technique was explored using an airbag-selective portal vein blood arrester that circumvents the need for an intraoperative assessment of anatomical variations in patients with complex intrahepatic space-occupying lesions.Methods:Rabbits undergoing hepatectomy were randomly assigned to 4 groups:intermittent portal triad clamping(PTC),intermittent portal vein clamping(PVC),intermittent portal vein blocker with an airbag-selective portal vein blood arrester(APC),and without portal blood occlusion(control).Hepatic ischemia and reperfusion injury were assessed by measuring the 7-day survival rate,blood loss,liver function,hepatic pathology,hepatic inflammatory cytokine infiltration,hepatic malondialdehyde levels,and proliferating cell nuclear antigen levels.Results:Liver damage was substantially reduced in the APC and PVC groups.The APC animals exhibited transaminase levels similar to or less oxidative stress damage and inflammatory hepatocellular injury compared to those exhibited by the PVC animals.Bleeding was significantly higher in the control group than in the other groups.The APC group had less bleeding than the PVC group because of the avoidance of portal vein skeletonization during hepatectomy.Thus,more operative time was saved in the APC group than in the PVC group.Moreover,the total 7-day survival rate in the APC group was higher than that in the PTC group.Conclusion:Airbag-selective portal vein blood arresters may help protect against hepatic ischemia and reperfusion injury in rabbits undergoing partial hepatectomy.This technique may also help prevent liver damage in patients requiring hepatectomy.
文摘BACKGROUND Hem-o-lok clips are typically used to control the cystic duct and vessels during laparoscopic cholecystectomy(LC)and common bile duct exploration for stones in the bile duct and gallbladder.Here,we report a unique example of Hem-o-lok clip movement towards the duodenal bulb after LC,appearing as a submucosal tumor(SMT).Additionally,we provide initial evidence of gradual and evolving endoscopic manifestations of Hem-o-lok clip migration to the duodenal bulb wall and review the available literature.CASE SUMMARY A 72-year-old man underwent LC for gallstones,and Hem-o-lok clips were used to ligate both the cystic duct and cystic artery.Esophagogastroduodenoscopy(EGD)2 years later revealed an SMT-like lesion in the duodenal bulb.Due to the symptomatology,the clinical examination did not reveal any major abnormalities,and the patient was followed up as an outpatient.A repeat EGD performed 5 months later revealed an SMT-like lesion in the duodenal bulb with raised edges and a central depression.A third EGD was conducted,during which a Hem-o-lok clip was discovered connected to the front side of the duodenum.The clip was extracted easily using biopsy forceps,and no complications occurred.Two months after the fourth EGD,the scar was surrounded by normal mucosa.CONCLUSION Clinicians should be aware of potential post-LC complications.Hem-o-lok clips should be removed if symptomatic.