Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora...Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.展开更多
Objective To study the role of bladder trabeculation found by B-mode ultrasound in evaluating the degree of bladder outlet obstruction ( BOO ) and the bladder function in benign prostatic hyperplasia ( BPH) patients. ...Objective To study the role of bladder trabeculation found by B-mode ultrasound in evaluating the degree of bladder outlet obstruction ( BOO ) and the bladder function in benign prostatic hyperplasia ( BPH) patients. Methods Conducted prospective research to determine differences in clinical data and urodynamic展开更多
BACKGROUND Intestinal lymphoma is a rare tumor.Contrast-enhanced ultrasound(CEUS)findings of intestinal lymphoma have not been reported previously,and the relationship between CEUS and clinicopathological features and...BACKGROUND Intestinal lymphoma is a rare tumor.Contrast-enhanced ultrasound(CEUS)findings of intestinal lymphoma have not been reported previously,and the relationship between CEUS and clinicopathological features and prognostic factors is still unknown.AIM To describe the B-mode US and CEUS features of intestinal lymphoma and investigate the correlation of CEUS and histopathological features.METHODS This was a single-center retrospective study.Eighteen patients with histologically confirmed intestinal lymphoma underwent B-mode US and CEUS examinations between October 2016 and November 2019.We summarized the features of Bmode US and CUES imaging of intestinal lymphoma and compared the frequency of tumor necrosis in intestinal lymphomas with reference to different pathological subtypes(aggressive or indolent)and clinical stage(early or advanced).The time–intensity curve parameters of CEUS were also compared between patients with normal and elevated serum lactate dehydrogenase.RESULTS In B-mode imaging,four patterns were observed in intestinal lymphoma:Mass type(12/18,66.7%),infiltration type(1/18,5.6%),mesentery type(4/18,22.2%)and mixed type(1/18,5.6%).All cases were hypoechoic and no cystic areas were detected.On CEUS,most cases(17/18,94.4%)showed arterial hyperechoic enhancement.All cases showed arterial enhancement followed by venous wash out.A relatively high rate of tumor necrosis(11/18,61.1%)was observed in this study.Tumor necrosis on CEUS was more frequent in aggressive subtypes(10/13,76.9%)than in indolent subtypes(1/5,20.0%)(P=0.047).There were no correlations between tumor necrosis and lesion size and Ann Arbor stage.There was no significant difference in time–intensity curve parameters between normal and elevated lactate dehydrogenase groups.CONCLUSION B-mode US and CEUS findings of intestinal lymphoma are characteristic.We observed a high rate of tumor necrosis,which appeared more frequently in aggressive pathological subtypes of intestinal lymphoma.展开更多
This paper deals with the temperature correlation of gray scale of B-mode ultrasound image from heated tissue. In this study, many in-vitro fresh pig livers are heated in a temperature range from 28 ℃ to 45℃, from w...This paper deals with the temperature correlation of gray scale of B-mode ultrasound image from heated tissue. In this study, many in-vitro fresh pig livers are heated in a temperature range from 28 ℃ to 45℃, from which a series of B-mode ultrasonic images of livers were obtained. The gray-value is evaluated from the ultrasound images respectively. A correlation of the mean gray value of the selected regions (12×12 pixels) in B-mode ultrasonic images of liver and its temperature was pointed out. And the experiment results agreed the evaluation well. And it is possible to monitor the tissue temperature changing in hyperthermia using this correlation.展开更多
Deep neural network(DNN)based computer-aided breast tumor diagnosis(CABTD)method plays a vital role in the early detection and diagnosis of breast tumors.However,a Brightness mode(B-mode)ultrasound image derives train...Deep neural network(DNN)based computer-aided breast tumor diagnosis(CABTD)method plays a vital role in the early detection and diagnosis of breast tumors.However,a Brightness mode(B-mode)ultrasound image derives training feature samples that make closer isolation toward the infection part.Hence,it is expensive due to a metaheuristic search of features occupying the global region of interest(ROI)structures of input images.Thus,it may lead to the high computational complexity of the pre-trained DNN-based CABTD method.This paper proposes a novel ensemble pretrained DNN-based CABTD method using global-and local-ROI-structures of B-mode ultrasound images.It conveys the additional consideration of a local-ROI-structures for further enhan-cing the pretrained DNN-based CABTD method’s breast tumor diagnostic performance without degrading its visual quality.The features are extracted at various depths(18,50,and 101)from the global and local ROI structures and feed to support vector machine for better classification.From the experimental results,it has been observed that the combined local and global ROI structure of small depth residual network ResNet18(0.8 in%)has produced significant improve-ment in pixel ratio as compared to ResNet50(0.5 in%)and ResNet101(0.3 in%),respectively.Subsequently,the pretrained DNN-based CABTD methods have been tested by influencing local and global ROI structures to diagnose two specific breast tumors(Benign and Malignant)and improve the diagnostic accuracy(86%)compared to Dense Net,Alex Net,VGG Net,and Google Net.Moreover,it reduces the computational complexity due to the small depth residual network ResNet18,respectively.展开更多
AIM:To assess the role of magnetic resonance cholangiopancreatography(MRCP) in detection of pancreatic duct stones(PDS) in patients with chronic pancreatitis(CP).METHODS:Clinical data of 78 CP patients who were treate...AIM:To assess the role of magnetic resonance cholangiopancreatography(MRCP) in detection of pancreatic duct stones(PDS) in patients with chronic pancreatitis(CP).METHODS:Clinical data of 78 CP patients who were treated at the First Affi liated Hospital of Xi'an Jiaotong University(China) between January 2004 and July 2008 were retrospectively analyzed.A predictive model of pancreatic duct stones was established through logistic regression and its effectiveness was verifi ed.Among these patients, MRCP was performed in 60 patients who served as a control group, while 44 patients with a higher predictive value than the entry threshold of the predictive model served as an experimental group.RESULTS:The positive rate of PDS in the 78 patients with CP was 19.2%(15/78).The predictive entry threshold of the predictive model was 5%(P < 0.05).The possibility of existence of PDS could be predicted according to the following 4 indexes:gastrointestinal symptoms, intermittent abdominal pain, diabetes mellitus(DM)/impaired glucose tolerance(IGT) and positive B-mode ultrasound results.The incidence of PDS in the experimental group was higher than that in the control group(P < 0.05).CONCLUSION:MRCP is strongly suggested for the detection of PDS in patients with gastrointestinal symptoms, intermittent abdominal pain, DM/IGT and positive B-mode ultrasound results.展开更多
Sediment incipient velocity (SIV) is a vital parameter for sediment research and river dynamics. This paper describes a novel method of estimating SIV based on the known flow velocity in the movable-bed model experi...Sediment incipient velocity (SIV) is a vital parameter for sediment research and river dynamics. This paper describes a novel method of estimating SIV based on the known flow velocity in the movable-bed model experiment. In this method, we use B-mode ultrasound imaging technique to get video images of moving particles and topography under water. By statistical analysis of video images, the relationship between the average number of imaging particles and flow velocity is obtained. The relationship between the change rate of average number and flow velocity is analyzed in sediment incipient process. These relationships are used to estimate the SIV. Lastly, the changed topography verifies the estimated velocity. The results show there is a sudden change in these relationships which can be used to estimate the SIV with high resolution by using a B-mode ultrasound device. The estimated SIV of plastic sands (particle size is about 0.25 mm) is 3.64 cm · s^-1 and the estimated SIV of natural sands (particle size is about 0.25 mm) is 5.47 cm · s^-1in the same condition.展开更多
Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing fr...Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography.展开更多
AIM: To investigate the association between B-mode ultrasound classification of small hepatocellular carcinoma (HCC) and outcome after radiofrequency ablation (RFA).
Incidentally found focal liver lesions are a commonfinding and a reason for referral to hepatobiliary service.They are often discovered in patients with history of liver cirrhosis,colorectal cancer,incidentally during...Incidentally found focal liver lesions are a commonfinding and a reason for referral to hepatobiliary service.They are often discovered in patients with history of liver cirrhosis,colorectal cancer,incidentally during work up for abdominal pain or in a trauma setting.Specific points should considered during history taking such as risk factors of liver cirrhosis;hepatitis,alcohol consumption,substance exposure or use of oral con-traceptive pills and metabolic syndromes.Full blood count,liver function test and tumor markers can act as a guide to minimize the differential diagnosis and to categorize the degree of liver disease.Imaging should start with B-mode ultrasound.If available,contrast enhanced ultrasound is a feasible,safe,cost effective option and increases the ability to reach a diagnosis.Contrast enhanced computed tomography should be considered next.It is more accurate in diagnosis and better to study anatomy for possible operation.Contrast enhanced magnetic resonance is the gold standard with the highest sensitivity.If doubt still remains,the options are biopsy or surgical excision.展开更多
Background/Aims: In this study, the different types of arterial diameter measurement methods were com-pared with each other on rat model. Methods: The study was planned in three phases. In phase 1, all subjects (n = 3...Background/Aims: In this study, the different types of arterial diameter measurement methods were com-pared with each other on rat model. Methods: The study was planned in three phases. In phase 1, all subjects (n = 30) underwent high resolution B-mode ultrasound examination and external diameter of the right com-mon carotid artery (RCCA) was measured. In phase 2, RCCA was explored. In phase 3, rats were put into three groups. Group 1 was kept at -20oC, group 2 was embedded in 4% formaldehyde solution. In group 3, circulatory system was filled with %20 latex solution. In all groups, digital image of the RCCA was taken after the processes mentioned above. Images were assessed by Image – Pro Plus software. Results: The greatest average diameter was observed in the high resolution B-mode ultrasound (phase 1). In group 1 and 2, direct measurement of the RCCA on living animal (phase 2) gave significantly wider diameter than those obtained at phase 3 in the same groups. Direct (phase 2) and latex (phase 3) measurements were equal in group 3. Conclusion: High resolution B-mode ultrasound gives larger, probably actual diameter of the artery. Latex injection results might correspond those encountered during operation.展开更多
Quadrature demodulation is used in medical ultrasound imaging to derive the envelope and instantaneous phase of the received radio-frequency(RF) signal.In quadrature demodulation,RF signal is multiplied with the sine ...Quadrature demodulation is used in medical ultrasound imaging to derive the envelope and instantaneous phase of the received radio-frequency(RF) signal.In quadrature demodulation,RF signal is multiplied with the sine and cosine wave reference signal and then low-pass filtered to produce the base-band complex signal,which has high computational complexity.In this paper,we propose an efficient quadrature demodulation method for B-mode and color flow imaging,in which the RF signal is demodulated by a pair of finite impulse response filters without mixing with the reference signal,to reduce the computational complexity.The proposed method was evaluated with simulation and in vivo experiments.From the simulation results,the proposed quadrature demodulation method produced similar normalized residual sum of squares(NRSS) and velocity profile compared with the conventional quadrature demodulation method.In the in vivo color flow imaging experiments,the time of the demodulation process was 5.66 ms and 3.36 ms,for the conventional method and the proposed method,respectively.These results indicated that the proposed method can maintain the performance of quadrature demodulation while reducing computational complexity.展开更多
基金the National Natural Science Foundation of China,Nos.92159305,92259303,62027901,81930053,and 82272029Beijing Science Fund for Distinguished Young Scholars,No.JQ22013and Excellent Member Project of the Youth Innovation Promotion Association CAS,No.2016124.
文摘Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.
文摘Objective To study the role of bladder trabeculation found by B-mode ultrasound in evaluating the degree of bladder outlet obstruction ( BOO ) and the bladder function in benign prostatic hyperplasia ( BPH) patients. Methods Conducted prospective research to determine differences in clinical data and urodynamic
基金National Natural Science Foundation of China,No.81974268Medical and Health Science and Technology Innovation Project of Chinese Academy of Medical Sciences,No.2017-I2M-1-006Beijing Hope Run Special Fund of Cancer Foundation of China,No.LC2017B19 and No.LC2016A04.
文摘BACKGROUND Intestinal lymphoma is a rare tumor.Contrast-enhanced ultrasound(CEUS)findings of intestinal lymphoma have not been reported previously,and the relationship between CEUS and clinicopathological features and prognostic factors is still unknown.AIM To describe the B-mode US and CEUS features of intestinal lymphoma and investigate the correlation of CEUS and histopathological features.METHODS This was a single-center retrospective study.Eighteen patients with histologically confirmed intestinal lymphoma underwent B-mode US and CEUS examinations between October 2016 and November 2019.We summarized the features of Bmode US and CUES imaging of intestinal lymphoma and compared the frequency of tumor necrosis in intestinal lymphomas with reference to different pathological subtypes(aggressive or indolent)and clinical stage(early or advanced).The time–intensity curve parameters of CEUS were also compared between patients with normal and elevated serum lactate dehydrogenase.RESULTS In B-mode imaging,four patterns were observed in intestinal lymphoma:Mass type(12/18,66.7%),infiltration type(1/18,5.6%),mesentery type(4/18,22.2%)and mixed type(1/18,5.6%).All cases were hypoechoic and no cystic areas were detected.On CEUS,most cases(17/18,94.4%)showed arterial hyperechoic enhancement.All cases showed arterial enhancement followed by venous wash out.A relatively high rate of tumor necrosis(11/18,61.1%)was observed in this study.Tumor necrosis on CEUS was more frequent in aggressive subtypes(10/13,76.9%)than in indolent subtypes(1/5,20.0%)(P=0.047).There were no correlations between tumor necrosis and lesion size and Ann Arbor stage.There was no significant difference in time–intensity curve parameters between normal and elevated lactate dehydrogenase groups.CONCLUSION B-mode US and CEUS findings of intestinal lymphoma are characteristic.We observed a high rate of tumor necrosis,which appeared more frequently in aggressive pathological subtypes of intestinal lymphoma.
基金The research was supported by National Nature Science Foundation (30470450) Education Committee Foundation( KP0608200201 ) Elitist Foundation( KW5800200351 ) from Beijing City,China.
文摘This paper deals with the temperature correlation of gray scale of B-mode ultrasound image from heated tissue. In this study, many in-vitro fresh pig livers are heated in a temperature range from 28 ℃ to 45℃, from which a series of B-mode ultrasonic images of livers were obtained. The gray-value is evaluated from the ultrasound images respectively. A correlation of the mean gray value of the selected regions (12×12 pixels) in B-mode ultrasonic images of liver and its temperature was pointed out. And the experiment results agreed the evaluation well. And it is possible to monitor the tissue temperature changing in hyperthermia using this correlation.
文摘Deep neural network(DNN)based computer-aided breast tumor diagnosis(CABTD)method plays a vital role in the early detection and diagnosis of breast tumors.However,a Brightness mode(B-mode)ultrasound image derives training feature samples that make closer isolation toward the infection part.Hence,it is expensive due to a metaheuristic search of features occupying the global region of interest(ROI)structures of input images.Thus,it may lead to the high computational complexity of the pre-trained DNN-based CABTD method.This paper proposes a novel ensemble pretrained DNN-based CABTD method using global-and local-ROI-structures of B-mode ultrasound images.It conveys the additional consideration of a local-ROI-structures for further enhan-cing the pretrained DNN-based CABTD method’s breast tumor diagnostic performance without degrading its visual quality.The features are extracted at various depths(18,50,and 101)from the global and local ROI structures and feed to support vector machine for better classification.From the experimental results,it has been observed that the combined local and global ROI structure of small depth residual network ResNet18(0.8 in%)has produced significant improve-ment in pixel ratio as compared to ResNet50(0.5 in%)and ResNet101(0.3 in%),respectively.Subsequently,the pretrained DNN-based CABTD methods have been tested by influencing local and global ROI structures to diagnose two specific breast tumors(Benign and Malignant)and improve the diagnostic accuracy(86%)compared to Dense Net,Alex Net,VGG Net,and Google Net.Moreover,it reduces the computational complexity due to the small depth residual network ResNet18,respectively.
文摘AIM:To assess the role of magnetic resonance cholangiopancreatography(MRCP) in detection of pancreatic duct stones(PDS) in patients with chronic pancreatitis(CP).METHODS:Clinical data of 78 CP patients who were treated at the First Affi liated Hospital of Xi'an Jiaotong University(China) between January 2004 and July 2008 were retrospectively analyzed.A predictive model of pancreatic duct stones was established through logistic regression and its effectiveness was verifi ed.Among these patients, MRCP was performed in 60 patients who served as a control group, while 44 patients with a higher predictive value than the entry threshold of the predictive model served as an experimental group.RESULTS:The positive rate of PDS in the 78 patients with CP was 19.2%(15/78).The predictive entry threshold of the predictive model was 5%(P < 0.05).The possibility of existence of PDS could be predicted according to the following 4 indexes:gastrointestinal symptoms, intermittent abdominal pain, diabetes mellitus(DM)/impaired glucose tolerance(IGT) and positive B-mode ultrasound results.The incidence of PDS in the experimental group was higher than that in the control group(P < 0.05).CONCLUSION:MRCP is strongly suggested for the detection of PDS in patients with gastrointestinal symptoms, intermittent abdominal pain, DM/IGT and positive B-mode ultrasound results.
基金Supported by the Fundamental Research Funds for the Central Universities(2014212020205)
文摘Sediment incipient velocity (SIV) is a vital parameter for sediment research and river dynamics. This paper describes a novel method of estimating SIV based on the known flow velocity in the movable-bed model experiment. In this method, we use B-mode ultrasound imaging technique to get video images of moving particles and topography under water. By statistical analysis of video images, the relationship between the average number of imaging particles and flow velocity is obtained. The relationship between the change rate of average number and flow velocity is analyzed in sediment incipient process. These relationships are used to estimate the SIV. Lastly, the changed topography verifies the estimated velocity. The results show there is a sudden change in these relationships which can be used to estimate the SIV with high resolution by using a B-mode ultrasound device. The estimated SIV of plastic sands (particle size is about 0.25 mm) is 3.64 cm · s^-1 and the estimated SIV of natural sands (particle size is about 0.25 mm) is 5.47 cm · s^-1in the same condition.
基金Supported by Interdisciplinary Center for Clinical Research of the University Medical Center of Erlangen(to Knieling F)Erlangen Graduate School in Advanced Optical Technologies by the German Research Foundation in the framework of the German excellence initiative(to Waldner MJ)
文摘Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography.
文摘AIM: To investigate the association between B-mode ultrasound classification of small hepatocellular carcinoma (HCC) and outcome after radiofrequency ablation (RFA).
文摘Incidentally found focal liver lesions are a commonfinding and a reason for referral to hepatobiliary service.They are often discovered in patients with history of liver cirrhosis,colorectal cancer,incidentally during work up for abdominal pain or in a trauma setting.Specific points should considered during history taking such as risk factors of liver cirrhosis;hepatitis,alcohol consumption,substance exposure or use of oral con-traceptive pills and metabolic syndromes.Full blood count,liver function test and tumor markers can act as a guide to minimize the differential diagnosis and to categorize the degree of liver disease.Imaging should start with B-mode ultrasound.If available,contrast enhanced ultrasound is a feasible,safe,cost effective option and increases the ability to reach a diagnosis.Contrast enhanced computed tomography should be considered next.It is more accurate in diagnosis and better to study anatomy for possible operation.Contrast enhanced magnetic resonance is the gold standard with the highest sensitivity.If doubt still remains,the options are biopsy or surgical excision.
文摘Background/Aims: In this study, the different types of arterial diameter measurement methods were com-pared with each other on rat model. Methods: The study was planned in three phases. In phase 1, all subjects (n = 30) underwent high resolution B-mode ultrasound examination and external diameter of the right com-mon carotid artery (RCCA) was measured. In phase 2, RCCA was explored. In phase 3, rats were put into three groups. Group 1 was kept at -20oC, group 2 was embedded in 4% formaldehyde solution. In group 3, circulatory system was filled with %20 latex solution. In all groups, digital image of the RCCA was taken after the processes mentioned above. Images were assessed by Image – Pro Plus software. Results: The greatest average diameter was observed in the high resolution B-mode ultrasound (phase 1). In group 1 and 2, direct measurement of the RCCA on living animal (phase 2) gave significantly wider diameter than those obtained at phase 3 in the same groups. Direct (phase 2) and latex (phase 3) measurements were equal in group 3. Conclusion: High resolution B-mode ultrasound gives larger, probably actual diameter of the artery. Latex injection results might correspond those encountered during operation.
基金Project supported by the National Key Technology R&D Program of China(No.2011BAI12B02)the Fundamental Research Funds for the Central Universities,China(Nos.2014FZA5019 and 2015FZA5019)
文摘Quadrature demodulation is used in medical ultrasound imaging to derive the envelope and instantaneous phase of the received radio-frequency(RF) signal.In quadrature demodulation,RF signal is multiplied with the sine and cosine wave reference signal and then low-pass filtered to produce the base-band complex signal,which has high computational complexity.In this paper,we propose an efficient quadrature demodulation method for B-mode and color flow imaging,in which the RF signal is demodulated by a pair of finite impulse response filters without mixing with the reference signal,to reduce the computational complexity.The proposed method was evaluated with simulation and in vivo experiments.From the simulation results,the proposed quadrature demodulation method produced similar normalized residual sum of squares(NRSS) and velocity profile compared with the conventional quadrature demodulation method.In the in vivo color flow imaging experiments,the time of the demodulation process was 5.66 ms and 3.36 ms,for the conventional method and the proposed method,respectively.These results indicated that the proposed method can maintain the performance of quadrature demodulation while reducing computational complexity.