期刊文献+
共找到24,796篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
1
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE high performance liquid chromatography fluorescence detector
下载PDF
Rapid Determination of Dopamine and Its Metabolites During in vivo Cerebral Microdialysis by Routine High Performance Liquid Chromatography With Electrochemical Detection 被引量:1
2
作者 FU-CHUN JING HONG CHEN CHANG-LING LI 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第4期317-320,共4页
To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right... To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats. 展开更多
关键词 Dopamine (DA) 3 4-dihydroxyphenylacetic acid (DOPAC) Homovanillic acid (HVA) Cerebral microdialysis high performance liquid chromatography Electrochemical detection
下载PDF
On-line enrichment and determination of polycyclic aromatic hydrocarbons in atmospheric particulates using high performance liquid chromatography with fluorescence as detector 被引量:1
3
作者 HASHI Yuki WANG Tian-ran +1 位作者 LI Yue-qi LIN Jin-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1261-1265,共5页
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri... Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well. 展开更多
关键词 on-line enrichment on-line trap column high performance liquid chromatography (HPLC) atmospheric particulate polycyclic aromatic hydrocarbons (PAHs)
下载PDF
Optimization of Ultrasonic Extraction and Clean-up Protocol for the Determination of Polycyclic Aromatic Hydrocarbons in Marine Sediments by High-performance Liquid Chroma-tography Coupled with Fluorescence Detection 被引量:1
4
作者 PENG Xuewei YAN Guofang +3 位作者 LI Xianguo GUO Xinyun ZHOU Xiao WANG Yan 《Journal of Ocean University of China》 SCIE CAS 2012年第3期331-338,共8页
The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were pu... The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were purified with a miniaturized silica gel chromatographic column and analyzed with high performance liquid chromatography (HPLC) with a fluorescence detector. Ultrasonication with methanol-dichloromethane (2:1, v/v) mixture gave higher extraction efficiency than that with dichloromethane. Among the three elution solvents used in clean-up step, dichloromethane-hexane (2:3, v/v) mixture was the most satisfactory. Under the optimized conditions, the recoveries in the range of 54.82% to 94.70% with RSDs of 3.02% to 23.22% for a spiked blank, and in the range of 61.20% to 127.08% with RSDs of 7.61% to 26.93% for a spiked matrix, were obtained for the 15 PAHs studied, while the recoveries for a NIST standard reference SRM 1941b were in the range of 50.79% to 83.78% with RSDs of 5.24% to 21.38%. The detection limits were between 0.75 ng L-1 and 10.99 ng L-1for different PAHs. A sample from the Jiaozhou Bay area was examined to test the established methods. 展开更多
关键词 ultrasonic extraction marine sediment polycyclic aromatic hydrocarbon high performance liquid chromatography
下载PDF
Molecular Weight Distribution of Dissolved Organic Matter in Lake Hongfeng Determined by High Performance Size Exclusion Chromatography (HPSEC) With On-Line UV-Vis Absorbance and Fluorescence Detection 被引量:3
5
作者 岳兰秀 吴丰昌 +3 位作者 刘丛强 黎文 王静 梅毅 《Chinese Journal Of Geochemistry》 EI CAS 2004年第3期275-283,共9页
The molecular weight distribution (MWD) of dissolved organic matter (DOM) in lake waters from Lake Hongfeng was examined using high performance size exclusion chromatography (HPSEC) with UV-vis absorbance and fluoresc... The molecular weight distribution (MWD) of dissolved organic matter (DOM) in lake waters from Lake Hongfeng was examined using high performance size exclusion chromatography (HPSEC) with UV-vis absorbance and fluorescence detection. The elution curves obtained by absorbance and fluorescence techniques expressed similar patterns, with the exception of diminishing of large fraction and the peaks behind several seconds in fluorescence chromatograms. According to its molecular weight (MW), DOM in water samples is divided into several fractions: large ({>3.5} kDa); medium-large ({3.5}-{2.0} kDa); medium ({2.0}-{1.0} kDa) and small ({<1.0} kDa). The average molecular weight was calculated using the elution curve detected by UV-vis absorbance and fluorescence detection techniques. The results showed that the weight-average molecular weight (Mw) and number-average molecular weight (Mn) calculated by UV-vis absorbance techniques range from 1750 to 2050 Dalton and from 1450 to 1850 Dalton, respectively. And the Mw and Mn obtained by fluorescence detection are lower by 50 to 400 Dalton. As a reference, the molecular weight of Fluka humic acid (FHA) is larger than that of water samples by about 200 Dalton. The average molecular weight of DOM for water samples collected in March and July was compared. The results revealed that the molecular weight is lower for water samples obtained in July than that obtained in March, indicating the ambient environment has an influence on the molecular weight, including photo-degradation and biological activity. 展开更多
关键词 液化有机物 分子量 平均数 吸收比 荧光性 聚合化合物 湖水生物化学
下载PDF
Quantitative Analysis of Components in OC-CS Sprays by High Performance Liquid Chromatography with Double Wavelength UV Detection
6
作者 孙立权 陈振贺 +4 位作者 邱日祥 王莉晶 钱伟 耿利娜 罗爱芹 《Defence Technology(防务技术)》 SCIE EI CAS 2010年第3期216-219,共4页
The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under follo... The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray. 展开更多
关键词 analytical chemistry OC-CS sprays o-chlorobenzalmalononitrile oleoresin capsicum dihydrocapsaicin high performance liquid chromatography
下载PDF
A High-Performance Liquid Chromatography Method for the Simultaneous Determination of Five Index Components in Danhong Injection
7
作者 Yun An Tian Tian +2 位作者 Qinglin Wang Xingchu Gong Chenchen Wang 《American Journal of Analytical Chemistry》 CAS 2023年第11期481-492,共12页
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a... The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. 展开更多
关键词 Danhong Injection high performance liquid chromatography Phenolic Acid FLAVONOIDS
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
8
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides high performance liquid chromatography Diode array detection Dispersive liquid-liquid microextraction Water samples
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:2
9
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 high performance liquid chromatography Mass spectrometry RASAGILINE liquid-liquid extraction
下载PDF
Isolation and Purification of Unstable Iridoid Glucosides from Traditional Chinese Medicine by Preparative High Performance Liquid Chromatography Coupled with Solid-phase Extraction 被引量:1
10
作者 LI Cun-man XIAO Yuan-sheng +3 位作者 XUE Xing-ya FENG Jia-tao ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期392-396,共5页
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog... An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products. 展开更多
关键词 Unstable compound Isolation and purification Preparative high performance liquid chromatography Solid-phase extraction Iridoid glucoside
下载PDF
Determination of AF and AFG in Red Ginseng by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSD) 被引量:2
11
作者 Chen Wei He Da Shao Ying 《Animal Husbandry and Feed Science》 CAS 2019年第5期131-134,共4页
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ... [Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate. 展开更多
关键词 high performance liquid chromatography Evaporative light scattering detector Amadori compounds Red ginseng
下载PDF
Research Advances in Detection Techniques of High Performance Liquid Chromatography-Refractive Index Detector 被引量:1
12
作者 Huo Fang Zhang Zhimei +3 位作者 Wang Jianjun Guo Shijin Zhou Chunfeng Fu Shijun 《Animal Husbandry and Feed Science》 CAS 2014年第2期87-90,共4页
As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in... As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in the fields of quantitative determination of medicine and food,in order to lay a foundation for wider use of RID. 展开更多
关键词 Refractive index detector high performance liquid chromatography Research progress
下载PDF
Dispersive Liquid-liquid Microextraction Combined with High-performance Liquid Chromatography for the Determination of Clozapine and Chlorpromazine in Urine 被引量:3
13
作者 陈静 熊朝梅 +1 位作者 阮金兰 苏邹 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第2期277-284,共8页
A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid ... A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 μg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R20.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine. 展开更多
关键词 dispersive liquid-liquid microextraction CLOZAPINE CHLORPROMAZINE high-performance liquid chromatography human urine
下载PDF
Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography coupled with diode array detector and evaporative light scattering detector 被引量:4
14
作者 Yi-Kai Shi Fang Cui +3 位作者 Fang-Di Hu Ying-Yan Bi Yu-Feng Ma Shi-Lan Feng 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期20-25,共6页
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo... A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation. 展开更多
关键词 high-performance liquid chromatography(HPLC) diode array detector(DAD) evaporative light scattering detector(ELSD) Zhenqi Fuzheng preparation quantification hierarchical cluster analysis
下载PDF
Establishing a protein expression profile database for the normal human pituitary gland using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry 被引量:2
15
作者 Rong Xie Wei Xu +4 位作者 Weimin Bao Hang Liu Luping Chen Yiwen Shen Jianhong Zhu 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第36期2922-2928,共7页
In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around th... In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around the tumor, and analyzed the protein expression of human normal pituitary using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry proteomics technology. The ten most highly expressed proteins in normal human pituitary were: alpha 3 type VI collagen isoform 5 precursor (abundance among tall pituitary proteins 1.30%), fibrinogen beta chain preproprotein (0.99%), vimentin (0.73%), prolactin (0.69%), ATP synthase, H~ transporting and mitochondrial F1 complex beta subunit precursor (0.52%), keratin I (0.49%), growth hormone (0.45%), carbonic anhydrase I (0.40%), heat shock protein 90 kDa I (0.31%), and annexin V (0.30%). Based on the biological function classifications of these proteins, the top three categories by content were neuroendocrine proteins (abundance among all pituitary proteins, 40.1%), catalytic and metabolic proteins (28.3%), and cell signal transduction proteins (9.8%). Based on cell positioning classification, the top three categories were cell organelle (24.5%) membrane (20.8%), and cytoplasm (13.0%). Based on biological process classification, the top three categories of proteins are involved in physiological processes (42.9%), cellular processes (40.4%), and regulation of biological processes (9.1%). Our experimental findings indicate that a protein expression profile database of normal human pituitary can be precisely and efficiently established by proteomics technology. 展开更多
关键词 two-dimensional high-performance liquid chromatography mass spectrum pituitary gland PROTEINS PROTEOMICS hypophyseal tumor physiological function pathological mechanism
下载PDF
Biological Fingerprinting Analysis of Interaction Between Taxoids in Taxus and Microtubule Protein by Microdialysis Coupled with High-performance Liquid Chromatography/Mass Spectrometry for Screening Antimicrotubule Agents 被引量:1
16
作者 LEI Xiao-yuan KONG Liang +2 位作者 SU Xing-ye GUO Ming ZOU Han-fa 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2008年第4期411-419,共9页
Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and con... Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography (HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus) to microtubules is reported. It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis, and they were identified as the taxoids of taxol, baccatin III, 10-deacetylbaccatin Ⅲ(10-DAB), cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples, both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated. It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP. Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated. 展开更多
关键词 Microdialysis/high-performance liquid chromatography(HPLC) Biological fingerprinting analysis TAXOIDS MICROTUBULE TAXUS
下载PDF
High Performance Liquid Chromatography Separation and Simultaneous Fluorometric Detection of Trace Amount of Polyamines in Cell Culture Media
17
作者 王淳本 雷景迈 +1 位作者 柴锡禄 何善述 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第2期125-128,共4页
A highly sensitive and precise method for the determination of the polyamines (including putrescine, spermidine and spermine) in cell culture media is described. The samples were concentrated by C18 column and the pol... A highly sensitive and precise method for the determination of the polyamines (including putrescine, spermidine and spermine) in cell culture media is described. The samples were concentrated by C18 column and the polyamines were converted to fluorometric derivatives with DNS-Cl. The polyamine derivatives were then completely separated by HPLC and determined by simultaneous fluorometric detection. The CV of intragroup and intergroup were 2. 49 %-4. 26% and 4. 29 %-5. 16 %, respectively. The rate of recovery was 103%- 99%. There was trace amount of polyamines detected by this method in the media of F12, 8900, RPMI1640, DMEM and M199 even without incubation with cells. So this method can be used for detecting the changes of polyamines in a medium before and after incubation with cells. It is helpful for the researches on the regulation of cell proliferation by polyamines. 展开更多
关键词 medium PUTRESCINE SPERMIDINE SPERMINE high performance liquid chromatography fluorospectrophotometry
下载PDF
Determination of neomycin in water samples by high performance anion chromatography with pulsed amperometric detection
18
作者 Bin Guan Dong Xing Yuan 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第2期201-204,共4页
A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were car... A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were carried out with an isocratic mobile phase, containing 10 mmol/L NaOH. The influence of the concentration and pH of the mobile phase on the separation and detection was investigated. A quadruple-potential waveform used for the detection was optimized. The detection limit of neomycin was down to 0.027 μg/mL. The linearity of neomycin calibration curve ranged from 0.050 to 0.505 μg/mL with correlation coefficient of 0.9997. R.S.D. (n = 11) was 4.0%. 展开更多
关键词 NEOMYCIN high performance anion chromatography Pulsed amperometric detection
下载PDF
Study on the Flow Injection Micro-Column Pre-Separation System Coupled With High Performance Liquid Chromatography for the Determination of Ecdysterone in Traditional Chinese Medicine
19
作者 SHUAI Qin QIN Yong-chao +2 位作者 JIANG Zu-cheng LI Feng LIAO Zhen-huan (College of Chemistry and Environmental Science, Wuhan University, Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期83-88,共6页
A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chine... A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk. 展开更多
关键词 high performance liquid chromatography(HPLC) Flow injection analysis (FIA) ECDYSTERONE traditional Chinese medicine
下载PDF
Analysis of microsatellite instability in stool DNA of patients with colorectal cancer using denaturing high performance liquid chromatography
20
作者 Seok-Byung Lim Seung-Yong Jeong +10 位作者 Il-Jin Kim Dae Yong Kim Kyung Hae Jung Hee Jin Chang Hyo Seong Choi Dae Kyung Sohn Hio Chung Kang Yong Shin Sang-Geun Jang Jae-Hyun Park Jae-Gahb Park 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第41期6689-6692,共4页
AIM: To evaluate the usefulness of denaturing high performance liquid chromatography (DHPLC) for analyzing microsatellite instability (MSI) status in stool DNA of patients with colorectal cancer. METHODS: A tota... AIM: To evaluate the usefulness of denaturing high performance liquid chromatography (DHPLC) for analyzing microsatellite instability (MSI) status in stool DNA of patients with colorectal cancer. METHODS: A total of 80 cancer tissues from patients with primary sporadic colorectal tumor (proximal cancer: 27, distal cancer: 53) and matched stool (which were employed for comparison with the tissues) were analyzed for MSI status in BAT 26. DNA samples extracted from stool were evaluated by nested polymerase chain reaction (PCR) and DHPLC for MSI analysis. RESULTS: Six cases (7.5%) of MSI were identified in BAT 26 from 80 cancer tissues. All the stool DNA samples from patients whose cancer tissue showed IVlSI also displayed MSI in BAT 26. CONCLUSION: As MSI is one of the established fecal DNA markers to screen colorectal cancer, we propose to use DHPLC for the IVlSI analysis in fecal DNA. 展开更多
关键词 Colorectal cancer Denaturing high performance liquid chromatography Fecal DNA MicrosateUite instability STOOL
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部