期刊文献+
共找到2,151篇文章
< 1 2 108 >
每页显示 20 50 100
Experimental investigation on high heat flux plasma parameters of HIT-PSI device in argon discharges
1
作者 Tao HUANG Qiuyue NIE +7 位作者 Cheng CHEN Lin NIE Wei ZHAO Tao JIANG Yang LIU Xu ZHAO Feng LI Xiaogang WANG 《Plasma Science and Technology》 2025年第1期118-127,共10页
Researches on plasma-facing materials/components(PFMs/PFCs)have become a focus in magnetic confinement fusion studies,particularly for advanced tokamak operation scenarios.Similarly,spacecraft surface materials must m... Researches on plasma-facing materials/components(PFMs/PFCs)have become a focus in magnetic confinement fusion studies,particularly for advanced tokamak operation scenarios.Similarly,spacecraft surface materials must maintain stable performance under relatively high temperatures and other harsh plasma conditions,making studies of their thermal and ablation resistance critical.Recently,a low-cost,low-energy-storage for superconducting magnets,and compact linear device,HIT-PSI,has been designed and constructed at Harbin Institute of Technology(HIT)to investigate the interaction between stable high heat flux plasma and PFMs/PFCs in scrape-off-layer(SOL)and divertor regions,as well as spacecraft surface materials.The parameters of the argon plasma beam of HIT-PSI are diagnosed using a water-cooled planar Langmuir probe and emission spectroscopy.As magnetic field rises to 2 T,the argon plasma beam generated by a cascaded arc source achieves high density exceeding 1.2×10^(21)m^(-3)at a distance of 25 cm from the source with electron temperature surpassing 4 eV,where the particle flux reaches 10^(24)m^(-2)s^(-1),and the heat flux loaded on the graphite target measured by infrared camera reaches 4 MW/m^(2).Combined with probe and emission spectroscopy data,the transport characteristics of the argon plasma beam are analyzed. 展开更多
关键词 linear plasma device plasma-material interaction high heat flux high particle flux
下载PDF
Analysis of the Effect of High-Dose Segmental Citrate Anticoagulation in High Flux Hemodialysis
2
作者 Xubo Fu 《Journal of Clinical and Nursing Research》 2024年第5期95-99,共5页
Objective:To analyze the clinical effect of high-dose citrate in segmental extracorporeal anticoagulation for high-throughput hemodialysis.Methods:The subjects included in this study were admitted to the hospital for ... Objective:To analyze the clinical effect of high-dose citrate in segmental extracorporeal anticoagulation for high-throughput hemodialysis.Methods:The subjects included in this study were admitted to the hospital for maintenance hemodialysis treatment from January 2021 to January 2023.All patients had a high risk of bleeding and received 4%trisodium citrate anticoagulant treatment,administered at a rate of 200 mL/h before and after the dialyzer.The anticoagulant effects achieved by the patients were observed and analyzed.Results:The total number of patients who received high-dose segmented citrate extracorporeal anticoagulation dialysis treatment was 50,with each patient undergoing 100 treatments.During the treatment,2 patients had to end the treatment early due to transmembrane pressure exceeding 30 mmHg and an increase in venous pressure exceeding 250 mmHg;the treatment times for these patients were 20 minutes and 200 minutes,respectively.The remaining patients successfully completed the 4-hour treatment.Blood pH and calcium ion concentration in the venous pot were monitored.It was observed that before dialysis,after 2 hours of dialysis,and at the end of dialysis,the blood pH of the patients remained within a relatively normal range.Although some patient levels changed after dialysis,they remained within the normal range.No adverse reactions(such as numbness of the limbs or convulsions)were observed during the anticoagulant treatment.Conclusion:Administering 4%trisodium citrate at a rate of 200 mL/h before and after the dialyzer achieves a good anticoagulant effect,maintains the patient’s blood gas levels within the normal range at the end of dialysis,and causes no adverse reactions. 展开更多
关键词 high dose Segmented citrate high flux HEMODIALYSIS Anticoagulation effect
下载PDF
Evaluation of ultra-fine grained tungsten under transient high heat flux by high-intensity pulsed ion beam 被引量:2
3
作者 谈军 周张健 +4 位作者 朱小鹏 郭双全 屈丹丹 雷明凯 葛昌纯 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2012年第5期1081-1085,共5页
Pure tungsten, oxide dispersion strengthened tungsten and carbide dispersion strengthened tungsten were fabricated by high-energy ball milling and spark plasma sintering process. In order to evaluate the properties of... Pure tungsten, oxide dispersion strengthened tungsten and carbide dispersion strengthened tungsten were fabricated by high-energy ball milling and spark plasma sintering process. In order to evaluate the properties of the tungsten alloys under transient high heat flues, four tungsten samples with different grain sizes were tested by high-intensity pulsed ion beam with a heat flux as high as 160 MW/(m^2·s^-1/2). Compared with the commercial tungsten, the surface modification of the oxide dispersion strengthened tungsten by high-intensity pulsed ion beam is completely different. The oxide dispersion strengthened tungsten shows inferior thermal shock response due to the low melting point second phase of Ti and Y2O3, which results in the surface melting, boiling bubbles and cracking. While the carbide dispersion strengthened tungsten shows better thermal shock response than the commercial tungsten. 展开更多
关键词 TUNGSTEN tungsten alloy ultra-fine grain surface effects thermal shock transient high heat flux
下载PDF
PERVAPORATION OF ETHANOL/WATER MIXTURES WITH HIGH FLUX BY ZEOLITE-FILLED PDMS/PVDF COMPOSITE MEMBRANES 被引量:5
4
作者 李继定 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2009年第6期771-780,共10页
Thin-film zeolite-filled silicone/PVDF composite membranes were fabricated by incorporating zeolite particles into PDMS(poly(dimethylsiloxane)) membranes.The morphology of zeolite particles and zeolite filled silicone... Thin-film zeolite-filled silicone/PVDF composite membranes were fabricated by incorporating zeolite particles into PDMS(poly(dimethylsiloxane)) membranes.The morphology of zeolite particles and zeolite filled silicone composite membranes were characterized by SEM.The zeolite-filled PDMS/PVDF composite membranes were applied for the pervaporation of ethanol/water mixtures and showed higher flux compared with that reported in literatures.The effect of zeolite loading and Si/Al ratio of zeolite particles on pe... 展开更多
关键词 ZEOLITE PDMS high flux PERVAPORATION Ethanol recovery
下载PDF
Bone marrow-derived mesenchymal stem cell-derived exosomeloaded miR-129-5p targets high-mobility group box 1 attenuates neurological-impairment after diabetic cerebral hemorrhage 被引量:2
5
作者 Yue-Ying Wang Ke Li +5 位作者 Jia-Jun Wang Wei Hua Qi Liu Yu-Lan Sun Ji-Ping Qi Yue-Jia Song 《World Journal of Diabetes》 SCIE 2024年第9期1979-2001,共23页
BACKGROUND Diabetic intracerebral hemorrhage(ICH)is a serious complication of diabetes.The role and mechanism of bone marrow mesenchymal stem cell(BMSC)-derived exosomes(BMSC-exo)in neuroinflammation post-ICH in patie... BACKGROUND Diabetic intracerebral hemorrhage(ICH)is a serious complication of diabetes.The role and mechanism of bone marrow mesenchymal stem cell(BMSC)-derived exosomes(BMSC-exo)in neuroinflammation post-ICH in patients with diabetes are unknown.In this study,we investigated the regulation of BMSC-exo on hyperglycemia-induced neuroinflammation.AIM To study the mechanism of BMSC-exo on nerve function damage after diabetes complicated with cerebral hemorrhage.METHODS BMSC-exo were isolated from mouse BMSC media.This was followed by transfection with microRNA-129-5p(miR-129-5p).BMSC-exo or miR-129-5poverexpressing BMSC-exo were intravitreally injected into a diabetes mouse model with ICH for in vivo analyses and were cocultured with high glucoseaffected BV2 cells for in vitro analyses.The dual luciferase test and RNA immunoprecipitation test verified the targeted binding relationship between miR-129-5p and high-mobility group box 1(HMGB1).Quantitative polymerase chain reaction,western blotting,and enzyme-linked immunosorbent assay were conducted to assess the levels of some inflammation factors,such as HMGB1,interleukin 6,interleukin 1β,toll-like receptor 4,and tumor necrosis factorα.Brain water content,neural function deficit score,and Evans blue were used to measure the neural function of mice.RESULTS Our findings indicated that BMSC-exo can promote neuroinflammation and functional recovery.MicroRNA chip analysis of BMSC-exo identified miR-129-5p as the specific microRNA with a protective role in neuroinflammation.Overexpression of miR-129-5p in BMSC-exo reduced the inflammatory response and neurological impairment in comorbid diabetes and ICH cases.Furthermore,we found that miR-129-5p had a targeted binding relationship with HMGB1 mRNA.CONCLUSION We demonstrated that BMSC-exo can reduce the inflammatory response after ICH with diabetes,thereby improving the neurological function of the brain. 展开更多
关键词 Bone marrow mesenchymal stem cells Exosome Diabetic cerebral hemorrhage Neuroinflammation MicroRNA-129-5p high mobility group box 1
下载PDF
Conceptual design and safety characteristics of a new multi-mission high flux research reactor 被引量:3
6
作者 Wei Xu Jian Li +4 位作者 Heng Xie Zhi-Hong Liu Jing Zhao Fei Xie Lei Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第3期9-24,共16页
Research reactors with neutron fluxes higher than 10^(14) n cm^(−2) s^(−1) are widely used in nuclear fuel and material irradiation,neutron-based scientific research,and medical and industrial isotope production.Such ... Research reactors with neutron fluxes higher than 10^(14) n cm^(−2) s^(−1) are widely used in nuclear fuel and material irradiation,neutron-based scientific research,and medical and industrial isotope production.Such high flux research reactors are not only important scientific research facilities for the development of nuclear energy but also represent the national comprehensive technical capability.China has several high flux research reactors that do not satisfy the requirements of nuclear energy development.A high flux research reactor has the following features:a compact core arrangement,high power density,plate-type fuel elements,a short refueling cycle,and high coolant velocity in the core.These characteristics make it difficult to simultaneously realize high neutron flux and optimal safety margin.A new multi-mission high flux research reactor was designed by the Institute of Nuclear and New Energy Technology at Tsinghua University in China;the reactor can simul-taneously realize an average neutron flux higher than 2.0×10^(15) n cm^(−2) s^(−1) and fulfill the current safety criterion.This high flux research reactor features advanced design concepts and has sufficient safety margins according to the preliminary safety analysis.Based on the analysis of the station blackout accident,loss of coolant accident,and reactivity accident of a single-control drum rotating out accidently,the maximum temperature of the cladding surface,minimum departure from nucleate boiling ratio,and temperature difference to the onset of nucleate boiling temperature satisfy the design limits. 展开更多
关键词 high flux research reactor Neutron flux Safety analysis Maximum temperature of cladding surface Departure from nucleate boiling ratio
下载PDF
Flux-measuring approach of high temperature metal liquid based on BP neural networks 被引量:1
7
作者 胡燕瑜 桂卫华 李勇刚 《Journal of Central South University of Technology》 2003年第3期244-247,共4页
A soft-measuring approach is presented to measure the flux of liquid zinc with high temperature andcausticity. By constructing mathematical model based on neural networks, weighing the mass of liquid zinc, the fluxof ... A soft-measuring approach is presented to measure the flux of liquid zinc with high temperature andcausticity. By constructing mathematical model based on neural networks, weighing the mass of liquid zinc, the fluxof liquid zinc is acquired indirectly, the measuring on line and flux control are realized. Simulation results and indus-trial practice demonstrate that the relative error between the estimated flux value and practical measured flux value islower than 1.5%, meeting the need of industrial process. 展开更多
关键词 flux high temperature METAL LIQUID flux-measuring NEURAL NETWORKS
下载PDF
Manufacturing and High Heat Flux Testing of Brazed Flat-Type W/CuCrZr Plasma Facing Components 被引量:2
8
作者 练友运 刘翔 +4 位作者 封范 陈蕾 程正奎 王金 谌继明 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第2期184-189,共6页
Water-cooled flat-type W/Cu Cr Zr plasma facing components with an interlayer of oxygen-free copper(OFC) have been developed by using vacuum brazing route.The OFC layer for the accommodation of thermal stresses was ... Water-cooled flat-type W/Cu Cr Zr plasma facing components with an interlayer of oxygen-free copper(OFC) have been developed by using vacuum brazing route.The OFC layer for the accommodation of thermal stresses was cast onto the surface of W at a temperature range of 1150oC-1200 oC in a vacuum furnace.The W/OFC cast tiles were vacuum brazed to a Cu Cr Zr heat sink at 940 oC using the silver-free filler material Cu Mn Si Cr.The microstructure,bonding strength,and high heat flux properties of the brazed W/Cu Cr Zr joint samples were investigated.The W/Cu joint exhibits an average tensile strength of 134 MPa,which is about the same strength as pure annealed copper.High heat flux tests were performed in the electron beam facility EMS-60.Experimental results indicated that the brazed W/Cu Cr Zr mock-up experienced screening tests of up to 15 MW/m^2 and cyclic tests of 9 MW/m^2 for 1000 cycles without visible damage. 展开更多
关键词 W/CuCrZr mock-up vacuum casting vacuum brazing high heat flux tests
下载PDF
Radial Non-uniformity Index Research on High-density,High-flux CFB Riser with Stratified Injection 被引量:3
9
作者 Geng Qiang Wang Lu +3 位作者 Li Zhichao Li Chunyi Liu Yibin You Xinghua 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2012年第4期64-72,共9页
A high-density, high-flux circulating fluidized bed (CFB) riser (100 mm in ID and 10.614 m in height) was ap- plied in a wide range of operating conditions (with solid fluxes up to 400 kg/m2s and superficial gas ... A high-density, high-flux circulating fluidized bed (CFB) riser (100 mm in ID and 10.614 m in height) was ap- plied in a wide range of operating conditions (with solid fluxes up to 400 kg/m2s and superficial gas velocities up to 12 m/s) to examine its radial non-uniformity dynamics. The solids holdup was determined through the use of a fiber-optic probe at 11 axial levels. The results indicated that under all operating conditions, the high superficial gas velocity and low solid flux- es maintained a low radial non-uniformity index (RNI). The high-density/flux CFB riser had several unique characteristics, so that the peak of the radial solids holdup profile occurred at a position with r/R=0.8. The RNI and solids holdup at the cross-sectional position had a good logarithmic relationship at the low-density condition (with a mean solids holdup of 〈0.2), and the RNI decreased when the mean solids holdup exceeded 0.2. Investigation of the dynamics of stratified injec- tion revealed that the feed ratio had an important effect on G, and on solids holdup distribution. A novel "〈" shaped axial solids holdup profile was found. Gs decreased sharply when the up-flow feed ratio exceeded 0.5, and RNI was lowest when the up-flow feed ratio was 1. 展开更多
关键词 fluidization high density/flux CFB riser radial non-uniformity index stratified injection feed ratio
下载PDF
High X-Ray-to-Optical Flux Ratio Sources From RASS 被引量:1
10
作者 Xu D. W 1, 2 , Wei J. Y 1, 2 , Dong X. Y 1, 2 , Hu J.Y 1, 2 1 (Beijing Astronomical Observatory, The Chinese Academy of Sciences, Beijing 100012, China) 2 (National Astronomical Observatories, The Chinese Academy of Sciences, Beijing 10 《天文研究与技术》 CSCD 1999年第S1期312-314,共3页
We present the first results of a program to identify the unknown bright active galactic nuclei (AGN) in the ROSAT All Sky Survey Bright Source Catalog (RASSBSC). We have used lg C+04 R as an alternative expression fo... We present the first results of a program to identify the unknown bright active galactic nuclei (AGN) in the ROSAT All Sky Survey Bright Source Catalog (RASSBSC). We have used lg C+04 R as an alternative expression for lg (f x f opt ), where C is X-ray count rate and R stands for R magnitude. Then a high X-ray-to-optical flux ratio criterion has been used to select an AGN sample with 165 unidentified X-ray sources for optical spectroscopy. At present over 93% of the X-ray sources in the sample have been fully identified in the following classes: emission line AGNs, clusters of galaxies, BL Lacertae objects, and stars. 展开更多
关键词 high X-Ray-to-Optical flux Ratio Sources From RASS
下载PDF
Microchannel cooling technique for dissipating high heat flux on W/Cu flat-type mock-up for EAST divertor
11
作者 Mingxiang LU Le HAN +5 位作者 Qi ZHAO Juncheng QIU Jianhong ZHOU Dinghua HU Nanyu MOU Xuemei CHEN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第9期134-144,共11页
As an important component of tokamaks,the divertor is mainly responsible for extracting heat and helium ash,and the targets of the divertor need to withstand high heat flux of 10 MW m-2 for steady-state operation.In t... As an important component of tokamaks,the divertor is mainly responsible for extracting heat and helium ash,and the targets of the divertor need to withstand high heat flux of 10 MW m-2 for steady-state operation.In this study,we proposed a new strategy,using microchannel cooling technology to remove high heat load on the targets of the divertor.The results demonstrated that the microchannel-based W/Cu flat-type mock-up successfully withstood the thermal fatigue test of 1000 cycles at 10 MW m^(-2)with cooling water of 26 l min^(-1),30°C(inlet),0.8 MPa(inlet),15 s power on and 15 s dwell time;the maximum temperature on the heat-loaded surface(W surface)of the mock-up was 493°C,which is much lower than the recrystallization temperature of W(1200°C).Moreover,no occurrence of macrocrack and‘hot spot’at the W surface,as well as no detachment of W/Cu tiles were observed during the thermal fatigue testing.These results indicate that microchannel cooling technology is an efflcient method for removing the heat load of the divertor at a low flow rate.The present study offers a promising solution to replace the monoblock design for the EAST divertor. 展开更多
关键词 MICROCHANNEL DIVERTOR flat-type high heat flux test EAST
下载PDF
Evaluation of The Thermal Performance of Multi-Element Doped Graphite under Steady-State High Heat Flux
12
作者 陈俊凌 李建刚 +3 位作者 野田信明 久保田雄辅 郭全贵 裘亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第4期1387-1394,共8页
Multi-element doped graphite, GBST1308 has been developed as a plasma facing material (PFM) for high heat flux components of the HT-7U device. The thermal performance of the material under steady-state (SS) high heat ... Multi-element doped graphite, GBST1308 has been developed as a plasma facing material (PFM) for high heat flux components of the HT-7U device. The thermal performance of the material under steady-state (SS) high heat flux was evaluated under actively cooling conditions, the specimens were mechanically joined to copper heat sink with supercarbon sheet as a compliant layer between the interfaces. The experiments have been performed in a facility of ACT (actively cooling test stand) with a 100 kW electron gun in order to test the suitability and the loading limit of such materials. The surface temperature and bulk temperature distribution of the specimens were investigated. The experimental results are very encouraging that when heat flux is not more than 6 MW/m2, the surface temperature of GBST1308 is less than 1000℃, which is the lowest, compared with IG-430U and even with CX-2002U (CFC); The primary results indicate that the mechanically-joined material system by such a proper design as thin tile, super compliant layer, GBST as a PFM and copper-alloy heat sink, can be used as divertor plates for HT-7U in the first phase. 展开更多
关键词 doped graphite heat sink compliant layer steady state high heat flux surface temperature bulk temperature distribution
下载PDF
High-flux electron beams from laser wakefield accelerators driven by petawatt lasers
13
作者 Ming ZENG Ovidiu TESILEANU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第7期7-11,共5页
Laser wakefield accelerators (LWFAs) are considered to be one of the most compeuuve next- generation accelerator candidates. In this paper, we will study the potential high-flux electron beam production of an LWFA d... Laser wakefield accelerators (LWFAs) are considered to be one of the most compeuuve next- generation accelerator candidates. In this paper, we will study the potential high-flux electron beam production of an LWFA driven by petawatt-level laser pulses. In our three-dimensional particle-in-cell simulations, an optimal set of parameters gives -40 nC of charge with 2 PW laser power, thus -400 kA of instantaneous current if we assume the electron beam duration is 100 fs. This high flux and its secondary radiation are widely applicable in nuclear and QED physics, industrial imaging, medical and biological studies. 展开更多
关键词 laser accelerator petawatt laser high-flux electron beam
下载PDF
Numerical Simulation of Subcooled Boiling Inside High-Heat-Flux Component with Swirl Tube in Neutral Beam Injection System
14
作者 陶玲 胡纯栋 谢远来 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第5期512-520,共9页
In order to realize steady-state operation of the neutral beam injection(NBI) system with high beam energy,an accurate thermal analysis and a prediction about working conditions of heat-removal structures inside hig... In order to realize steady-state operation of the neutral beam injection(NBI) system with high beam energy,an accurate thermal analysis and a prediction about working conditions of heat-removal structures inside high-heat-flux(HHF) components in the system are key issues.In this paper,taking the HHF ion dump with swirl tubes in NBI system as an example,an accurate thermal dynamic simulation method based on computational fluid dynamics(CFD) and the finite volume method is presented to predict performance of the HHF component.In this simulation method,the Eulerian multiphase method together with some empirical corrections about the inter-phase transfer model and the wall heat flux partitioning model are considered to describe the subcooled boiling.The reliability of the proposed method is validated by an experimental example with subcooled boiling inside swirl tube.The proposed method provides an important tool for the refined thermal and flow dynamic analysis of HHF components,and can be extended to study the thermal design of other complex HHF engineering structures in a straightforward way.The simulation results also verify that the swirl tube is a promising heat removing structure for the HHF components of the NBI system. 展开更多
关键词 neutral beam injection system swirl tube subcooled boiling computational fluid dynamics high-heat-flux component ion dump
下载PDF
Mapping the Wall-Region Dynamics of High-Flux Gas-Solid Riser Using Scaling Regions from the Solid Concentration Time Series
15
作者 Justin M. Jeremiah Samwel V. Manyele +1 位作者 Abraham K. Temu Jesse-X. Zhu 《Engineering(科研)》 2019年第1期74-92,共19页
An experimental study of the gas-solid flow dynamics in the high-flux CFB riser was accomplished by analysing the scaling regions from solid concentration signals collected from a 76 mm internal diameters and 10 m hig... An experimental study of the gas-solid flow dynamics in the high-flux CFB riser was accomplished by analysing the scaling regions from solid concentration signals collected from a 76 mm internal diameters and 10 m high riser of a circulating fluidized bed (CFB) system. The riser was operated at 4.0 to 10.0 m/s gas velocity and 50 to 550 kg/m2s solids flux. Spent fluid catalytic cracking (FCC) catalyst particles of 67 μm mean diameter and 1500 kg/m3 density together with 70% to 80% humid air was used. Solid concentration data were analysed using codes prepared in FORTRAN 2008 to get correlation integrals at different embedding dimensions and operating conditions and plot their profiles. Scaling regions were identified by visual inspection method and their location on planes determined. Scaling regions were analysed based on operating conditions and riser spatial locations. It was found that scaling regions occupy different locations on the plane depending on the number of embedding dimensions and operating conditions. As the number of embedding dimensions increases the spacing between scaling regions decreases until it saturates towards higher embedding dimensions. Slopes of scaling regions increases with embedding dimensions until saturation where they become constant. Slopes of scaling regions towards the wall decrease while the number of scaling regions for a particular profile increases. The span of the scaling region is wider at the initial values of hyperspherical radius than its final values. The scaling regions in some flow development sections show multifractal behaviour for each embedding dimension which manifests into visible basin which is defined in this study as multifractal basin. Further, the end points of the scaling region for each correlation integral profile differ from each other as the embedding dimension changes. This study suggests that identification of scaling region by visual inspection method is useful in understanding the gas-solid flow dynamics in the High-Flux CFB riser system. Further studies are recommended on risers of different diameters and heights operated at low and high solid fluxes and different gas velocities for comparison or usage of time series of different signal types like pressure fluctuations. 展开更多
关键词 SCALING Region CORRELATION Integral CORRELATION Dimension Embedding Dimensions Multifractal Basin high-flux RISER
下载PDF
Analysis of Flow Dynamics in the High-Flux Gas-Solid Riser Using Trajectory Distances across Attractors Reconstructed from Solid Concentration Signals
16
作者 Justin M. Jeremiah Samwel V. Manyele +1 位作者 Abraham K. Temu Jesse-X. Zhu 《Engineering(科研)》 2018年第10期688-703,共16页
The study of the entrance and wall dynamics of a high-flux gas-solid riser was conducted using trajectory distances of the reconstructed attractors from solid concentration signals collected from a 76 mm internal diam... The study of the entrance and wall dynamics of a high-flux gas-solid riser was conducted using trajectory distances of the reconstructed attractors from solid concentration signals collected from a 76 mm internal diameters and 10 m high riser of a circulating fluidized bed (CFB) system. The riser was operated at 4.0 to 10.0 m/s gas velocity and 50 to 550 kg/m2s solids flux. Spent fluid catalytic cracking (FCC) catalyst particles with 67 μm mean diameter and density of 1500 kg/m3 together with 70% to 80% humid air was used. Solid concentration data were analyzed using codes prepared in FORTRAN 2008 to get trajectories of the reconstructed attractors and their distances apart. Trajectory distances were found to increase from the centre towards the wall indicating the expansion of the attractor. The probability density function (PDF) of the trajectory distances changes from single peak at the centre to multiple peaked profiles in the wall region. Multiple peaked profiles indicate multifractal flow behaviours. Cumulative distribution functions (CDF) of the trajectory distances changes from single S-shaped at the centre to multiple S-shaped profiles in some locations of the wall region indicating multifractal flow behaviours. The PDF distribution of these distances at the entrance section and in the wall region forms different types of statistical distributions showing differences in gas-solid flow structures in various spatial locations of the wall region and the entrance sections. Most of the distributions at the centre fall under the Gumbel max distribution for all flow development sections of the riser, especially at air velocities of 5.5 m/s and 8 m/s showing uniform flow structures. Further, it was found that increase of the number of the phase space reconstruction embedding dimension increases the trajectory distances between the state vectors leading to the expansion of the attractor. 展开更多
关键词 TRAJECTORY DISTANCE Probability Density FUNCTION Cumulative Distribution FUNCTION Euclidian DISTANCE high-flux RISER
下载PDF
Mapping Correlation Dimension along the Wall Region of a High-Flux Gas-Solid Riser Using Embedded Solid Concentration Time Series
17
作者 Justin M. Jeremiah Samwel V. Manyele +1 位作者 Abraham K. Temu Jesse-X. Zhu 《Engineering(科研)》 2018年第10期655-679,共25页
Analysis of the entrance and wall dynamics of a high-flux gas-solid riser was conducted using embedded solid concentration time series collected from a 76 mm internal diameter and 10 m high riser of a circulating flui... Analysis of the entrance and wall dynamics of a high-flux gas-solid riser was conducted using embedded solid concentration time series collected from a 76 mm internal diameter and 10 m high riser of a circulating fluidized bed (CFB) system. The riser was operated at 4.0 to 10.0 m/s air velocity and 50 to 550 kg/m2s solids flux of spent fluid catalytic cracking (FCC) catalyst particles with 67 μm mean diameter and density of 1500 kg/m3. Data were analyzed using prepared FORTRAN 2008 code to get correlation integral followed by determination of correlation dimensions with respect to the hyperspherical radius and their profiles, plots of which were studied. It was found that correlation dimension profiles at the centre have single peak with higher values than the wall region profiles. Towards the wall, these profiles have double or multiple peaks showing bifractal or multifractal flow behaviors. As the velocity increases the wall region profiles become random and irregular. Further it was found that, as the height increases the correlation dimension profiles shift towards higher hyperspherical radius at the centre and towards lower hyperspherical radius in the wall region at r/R = 0.81. The established method of mapping correlation dimension profiles in this study forms a suitable tool for analysis of high-flux riser dynamics compared to other analyses approaches. However, further analysis is recommended to other gas-solid CFB riser of different dimensions operated at high-flux conditions using the established method. 展开更多
关键词 CORRELATION Integral MAPPING CORRELATION Dimension high-flux GAS-SOLID RISER EMBEDDED Solid Concentration Time Series
下载PDF
Diagnosis of the Medium-Range Variation of the Subtropical High over the Western Pacific during a Meiyu Process by Three-Dimensional E-P Flux
18
作者 张启和 喻世华 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1990年第4期463-474,共12页
In this paper, using the daily grid data (2.5 × 2.5) of the ECMWF / WMO, we have computed respectively the three-dimensional wave activity flux in the stages of pre-onset, prevailing and post ending of Meiyu from... In this paper, using the daily grid data (2.5 × 2.5) of the ECMWF / WMO, we have computed respectively the three-dimensional wave activity flux in the stages of pre-onset, prevailing and post ending of Meiyu from 1 to 31 July 1982. The potential vorticity field is taken as the physical quantity relating the wave activity flux to the variation of the subtropical high over the Western Pacific. It is found that the three-dimensional wave activity flux is a powerful means for diagnosis of the variation of the subtropical high over the Western Pacific: The region of the subtropical high is just the confluence area of wave energy, whose changes in intensity and range decide the variation of the subtropical high. The confluence of wave energy comes from the monsoon flow in low latitudes, the Meiyu rain belts in middle latitudes and the heating fields on the eastern side of the Qinghai-Xizang Plateau. The relation between these sources and the subtropical high displays the self-adjusting mechanism among members of East-Asia summer monsoon. 展开更多
关键词 Diagnosis of the Medium-Range Variation of the Subtropical high over the Western Pacific during a Meiyu Process by Three-Dimensional E-P flux OVER
下载PDF
Preliminary High Heat Flux Tests of Small-Scale Be/Cu Mock-Ups
19
作者 LIU Xiang ZHANG Fu CHEN Jiming ZHANG Nianman PAN Chuanhong 《Southwestern Institute of Physics Annual Report》 2005年第1期115-116,共2页
China, as one of the members of ITER (international thermonuclear experimental reactor) project, one of the most important construction tasks is the fabrication of the first wall panel and shield blankets, which is ... China, as one of the members of ITER (international thermonuclear experimental reactor) project, one of the most important construction tasks is the fabrication of the first wall panel and shield blankets, which is the key engineering technology of ITER construction and might be one of the crucial issues of the future reactor too. Since 2004, an associated research team including Southwestern Institute of Physics ( SWIP ), Ninxia Non-ferrous Metal Co. Itd and Chinese Institute of Engineering Physics, as well as Nuclear Power Institute of China has been established. Up to now, several series of interlayer for hot isostatic press ( HIP ) connection of beryllium and CuCrZr alloy have been tested. They are titanium film or coating, Cu coating and Al or AISiMg alloy etc. The bonding strength (tensile or shear strength ) of HIPed Be/Cu joints is up to 100 MPa. 展开更多
关键词 ITER high heat flux tests Be/Cu mock-ups
下载PDF
前列腺癌患者外周血中CD4^+CD25^(high)调节性T细胞及调节因子TGF-β1和COX-2的表达
20
作者 夏桃林 刘涛 +5 位作者 吴振权 张海滨 杨明 刘绍远 何灼彬 李辽源 《中华男科学杂志》 CAS CSCD 北大核心 2011年第10期888-893,共6页
目的:通过检测前列腺癌患者以及健康志愿者外周血中CD4+CD25high调节性T细胞、TGF-β1及COX-2的表达,初步探讨CD4+CD25high调节性T细胞在前列腺癌发病机制中的作用及其与TGF-β1和COX-2的相关性。方法:应用流式细胞术检测30例前列腺癌... 目的:通过检测前列腺癌患者以及健康志愿者外周血中CD4+CD25high调节性T细胞、TGF-β1及COX-2的表达,初步探讨CD4+CD25high调节性T细胞在前列腺癌发病机制中的作用及其与TGF-β1和COX-2的相关性。方法:应用流式细胞术检测30例前列腺癌患者治疗前后(其中前列腺癌局限组11例,非局限组19例)及20例健康志愿者外周血单个核细胞(PBMC)中CD4+CD25high调节性T细胞占CD4+T细胞的比例;应用酶联免疫吸附试验(ELISA)检测其外周血清中TGF-β1和COX-2的表达。对前列腺癌患者上述指标进行术前术后对比分析,另对CD4+CD25high调节性T细胞与TGF-β1及COX-2的相关性进行分析;并探讨上述指标在前列腺癌患者局限组和非局限组间是否存在差异性。结果:流式细胞术检测显示,前列腺癌患者治疗前PBMC中CD4+CD25high调节性T细胞占CD4+T细胞的比例为(18.32±7.49)%,高于健康志愿者对照组(7.77±1.86)%(P<0.05)。前列腺癌患者治疗后其比值为(17.34±5.87)%,较治疗前稍减低,但两者相比无显著差异(P>0.05)。ELISA检测外周血清中TGF-β1和COX-2显示,前列腺癌组分别为(215.97±55.16)ng/ml和(6.88±5.14)ng/ml,对照组分别为(149.75±47.11)ng/ml和(5.65±2.69)ng/ml;前列腺癌患者外周血清中TGF-β1的表达水平高于健康志愿者对照组(P<0.05),COX-2的表达水平与对照组无显著差异(P>0.05)。通过多重线性回归分析表明,前列腺癌患者PBMC中CD4+CD25high调节性T细胞的表达与血清中TGF-β1和COX-2的表达无显著相关。前列腺癌局限组和非局限组外周血中CD4+CD25high调节性T细胞、TGF-β1及COX-2的表达均无显著性差异(P>0.05)。结论:前列腺癌患者PBMC中CD4+CD25high调节性T细胞可能参与前列腺癌的发生,其增殖机制与血清中TGF-β1和COX-2的表达无关,可能与肿瘤本身及肿瘤局部微环境相关。 展开更多
关键词 前列腺癌 CD4+CD25high调节性T细胞 转化生长因子Β1 环氧合酶-2
下载PDF
上一页 1 2 108 下一页 到第
使用帮助 返回顶部