This study evaluated the effects of early treatment with β-adrenergic blocker metoprolol on ventricular remodeling and function after acute myocardial infarction (AMI) by using high frequency ultrasound.The relations...This study evaluated the effects of early treatment with β-adrenergic blocker metoprolol on ventricular remodeling and function after acute myocardial infarction (AMI) by using high frequency ultrasound.The relationship between the efficacy and the expression level of cardiac myocardial inflammatory cytokine was examined in rats.The rat model of AMI was induced by ligating the left ante-rior descending artery.The surviving rats were randomly assigned to two experimental groups:MI control (MI) group and MI metoprolol (MI-B) group,with the rats undergoing sham operation serving as normal control (Sham).MI-B group was given metoprolol for 4 weeks (refer to the CCS-2 protocol) and the other two groups received equal volume of saline via intragastric (i.g.) administation.The ventricular remodeling and function were evaluated by high frequency ultrasound 4 weeks after the treatment.Then all rats were sacrificed for pathological examination and immunohistochemistrical detection of inflammatory cytokines,including IL-1β,IL-6,IL-10 and TNF-α.Compared with the MI group,the left ventricular end-systolic dimension,end-diastolic dimension,end-systolic volume and end-diastolic volume of the MI-B group were significantly decreased (P<0.01),while the left ventricular anterior wall end-diastolic thickness,ejection fraction and fractional shortening were obviously increased (P<0.01).The conspicuous improvement in the left ventricular morphology and function was coincident with the markedly reduced TNF-α and IL-1β expression and the increased IL-10 expression.We are led to conclude that early metoprolol treatment for AMI can regulate myocardial inflammatory cytokine expression to improve cardiac function and the underlying mechanism might be that it decreases the level of pro-inflammatory cytokines and increases the level of its anti-inflammatory counterparts in cardiac myocytes.Our study also showed that echocardiography is a useful technique for the structural and functional assessment of left ventricle after acute myocardial infarction.展开更多
<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging ev...<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types.展开更多
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ...High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.展开更多
The purpose of the research was to evaluate the role of high frequency ultrasound in monitoring and efficacy assessment of anti-cellulite treatments. A group of 66 women used 3 different types of anti-cellulite treatm...The purpose of the research was to evaluate the role of high frequency ultrasound in monitoring and efficacy assessment of anti-cellulite treatments. A group of 66 women used 3 different types of anti-cellulite treatments;additionally a placebo group (n = 18) was created. The μ-Scan ultrasound device with a 35 MHz mechanical probe was used for the examinations. The following parameters were subjected to the ultrasound evaluation: epidermis thickness, dermis thickness, dermis echogenicity, the length and area of subcutaneous tissue bands projecting into the dermis (dermis-hypodermis junction), as well as the presence/absence of edema within the dermis. As a result of anti-cellulite treatment, the length and area of dermis-hypodermis junction significantly decreased, and dermis echogenicity significantly increased. Ultrasound imaging made it possible to evaluate the efficacy of the applied treatments. The high frequency ultrasound is a useful imaging technique for the application in aesthetic dermatology and cosmetology.展开更多
Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitt...Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitted to the Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine from December 2017 to July 2018 were selected. They were all undergoing transperineal 3D volume ultrasound combined with 2D high-frequency ultrasound examination, and the diagnosis results were analyzed. The results of ultrasonography and surgical pathology were compared. Results: Among 52 patients, 3D volume ultrasound combined with 2D high-frequency ultrasound were used to diagnose 32 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 5 cases of supra-sphincter type, and 1 case of extra-sphincter type. T supervisor classification accuracy rate is 90%. The detection rate of branch pipes was 92%, and the compliance rate of internal fistula was 95%. Two-dimensional high-frequency ultrasound was used to diagnose 34 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 4 cases of supra-sphincter type, and 0 cases of extra-sphincter type. The detection rate of branch canals was 42%, and the accuracy of type classification was 90%. The coincidence rate was 95%. There was a statistically significant difference in the detection rate of the anal fistula branch and the coincidence rate of the internal fistula between the two methods (both P Conclusion: 1) The overall coincidence rate of three-dimensional volumetric ultrasound combined with two-dimensional high-frequency ultrasound in the diagnosis of anal fistula is high;2) Three-dimensional volumetric ultrasound technology has great application prospects in infants and anal fistulas.展开更多
Shoulder ultrasonography is approved as the examination of choice for rotator cuff abnormality in many centers around the world since it is an inexpensive and safe tool for investigation of rotator cuff abnormalities....Shoulder ultrasonography is approved as the examination of choice for rotator cuff abnormality in many centers around the world since it is an inexpensive and safe tool for investigation of rotator cuff abnormalities. The goal of this study was to determine the ultrasound findings in patients with acute shoulder joint pain, and also to identify possible predictors of shoulder pain, as well as to compare the ultrasound diagnostic performance to that of MRI in such condition. A total of 65 (mean age 28 ± 1.2 years) consequential patients were recruited for a period of six months between July 2015 and June 2016 in this study. Collected data were confined on age, medical history, and clinical symptoms. Shoulder ultrasound was performed with a linear array transducer (10 - 15 MHz) connected to HI vision Avius ultrasound unit;Hitachi. MRI for the shoulder joint was performed in all cases to confirm the ultrasound results, using 1.5-T MRI system (Magnetom Espree);Siemens. Statistical analysis was completed using the standard Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) version 20 for windows. Ultrasound manages to determine the causes of acute shoulder joint pain in 98% of the patients. Fitted achievement values for shoulder ultrasound in the diagnosis the causes of shoulder joint pain were 100% sensitivity and a range of 96% to 100% of accuracy. Ultrasound presents a high sensitivity and accuracy in diagnosis a wide spectrum of shoulder joint lesions, with a diagnostic performance near to that of MRI.展开更多
This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of trans...This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.展开更多
Ultrasonic communication in vertebrates is attracting increasing research interest.To determine if ultrasonic vocalization is common in birds,we recorded their vocalizations with ultrasound detectors in the Dongzhai N...Ultrasonic communication in vertebrates is attracting increasing research interest.To determine if ultrasonic vocalization is common in birds,we recorded their vocalizations with ultrasound detectors in the Dongzhai National Nature Reserve of Henan Province,China.We found varying degrees of high frequency components in the vocalizations of 14 species and in several of these species,the frequency of harmonics was up to the range of ultrasound.We suggest that more studies are required to determine whether the high frequency components in avian vocalizations have functions and what these functions are.In addition,the ability of birds to hear sounds in the high frequency range also requires re-examination.展开更多
Nerve growth factor(NGF) plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effect...Nerve growth factor(NGF) plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound(HFU) is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.展开更多
基金supported by the National Natural ScienceFoundation of China (No.30370574)
文摘This study evaluated the effects of early treatment with β-adrenergic blocker metoprolol on ventricular remodeling and function after acute myocardial infarction (AMI) by using high frequency ultrasound.The relationship between the efficacy and the expression level of cardiac myocardial inflammatory cytokine was examined in rats.The rat model of AMI was induced by ligating the left ante-rior descending artery.The surviving rats were randomly assigned to two experimental groups:MI control (MI) group and MI metoprolol (MI-B) group,with the rats undergoing sham operation serving as normal control (Sham).MI-B group was given metoprolol for 4 weeks (refer to the CCS-2 protocol) and the other two groups received equal volume of saline via intragastric (i.g.) administation.The ventricular remodeling and function were evaluated by high frequency ultrasound 4 weeks after the treatment.Then all rats were sacrificed for pathological examination and immunohistochemistrical detection of inflammatory cytokines,including IL-1β,IL-6,IL-10 and TNF-α.Compared with the MI group,the left ventricular end-systolic dimension,end-diastolic dimension,end-systolic volume and end-diastolic volume of the MI-B group were significantly decreased (P<0.01),while the left ventricular anterior wall end-diastolic thickness,ejection fraction and fractional shortening were obviously increased (P<0.01).The conspicuous improvement in the left ventricular morphology and function was coincident with the markedly reduced TNF-α and IL-1β expression and the increased IL-10 expression.We are led to conclude that early metoprolol treatment for AMI can regulate myocardial inflammatory cytokine expression to improve cardiac function and the underlying mechanism might be that it decreases the level of pro-inflammatory cytokines and increases the level of its anti-inflammatory counterparts in cardiac myocytes.Our study also showed that echocardiography is a useful technique for the structural and functional assessment of left ventricle after acute myocardial infarction.
文摘<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types.
文摘High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.
文摘The purpose of the research was to evaluate the role of high frequency ultrasound in monitoring and efficacy assessment of anti-cellulite treatments. A group of 66 women used 3 different types of anti-cellulite treatments;additionally a placebo group (n = 18) was created. The μ-Scan ultrasound device with a 35 MHz mechanical probe was used for the examinations. The following parameters were subjected to the ultrasound evaluation: epidermis thickness, dermis thickness, dermis echogenicity, the length and area of subcutaneous tissue bands projecting into the dermis (dermis-hypodermis junction), as well as the presence/absence of edema within the dermis. As a result of anti-cellulite treatment, the length and area of dermis-hypodermis junction significantly decreased, and dermis echogenicity significantly increased. Ultrasound imaging made it possible to evaluate the efficacy of the applied treatments. The high frequency ultrasound is a useful imaging technique for the application in aesthetic dermatology and cosmetology.
文摘Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitted to the Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine from December 2017 to July 2018 were selected. They were all undergoing transperineal 3D volume ultrasound combined with 2D high-frequency ultrasound examination, and the diagnosis results were analyzed. The results of ultrasonography and surgical pathology were compared. Results: Among 52 patients, 3D volume ultrasound combined with 2D high-frequency ultrasound were used to diagnose 32 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 5 cases of supra-sphincter type, and 1 case of extra-sphincter type. T supervisor classification accuracy rate is 90%. The detection rate of branch pipes was 92%, and the compliance rate of internal fistula was 95%. Two-dimensional high-frequency ultrasound was used to diagnose 34 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 4 cases of supra-sphincter type, and 0 cases of extra-sphincter type. The detection rate of branch canals was 42%, and the accuracy of type classification was 90%. The coincidence rate was 95%. There was a statistically significant difference in the detection rate of the anal fistula branch and the coincidence rate of the internal fistula between the two methods (both P Conclusion: 1) The overall coincidence rate of three-dimensional volumetric ultrasound combined with two-dimensional high-frequency ultrasound in the diagnosis of anal fistula is high;2) Three-dimensional volumetric ultrasound technology has great application prospects in infants and anal fistulas.
文摘Shoulder ultrasonography is approved as the examination of choice for rotator cuff abnormality in many centers around the world since it is an inexpensive and safe tool for investigation of rotator cuff abnormalities. The goal of this study was to determine the ultrasound findings in patients with acute shoulder joint pain, and also to identify possible predictors of shoulder pain, as well as to compare the ultrasound diagnostic performance to that of MRI in such condition. A total of 65 (mean age 28 ± 1.2 years) consequential patients were recruited for a period of six months between July 2015 and June 2016 in this study. Collected data were confined on age, medical history, and clinical symptoms. Shoulder ultrasound was performed with a linear array transducer (10 - 15 MHz) connected to HI vision Avius ultrasound unit;Hitachi. MRI for the shoulder joint was performed in all cases to confirm the ultrasound results, using 1.5-T MRI system (Magnetom Espree);Siemens. Statistical analysis was completed using the standard Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) version 20 for windows. Ultrasound manages to determine the causes of acute shoulder joint pain in 98% of the patients. Fitted achievement values for shoulder ultrasound in the diagnosis the causes of shoulder joint pain were 100% sensitivity and a range of 96% to 100% of accuracy. Ultrasound presents a high sensitivity and accuracy in diagnosis a wide spectrum of shoulder joint lesions, with a diagnostic performance near to that of MRI.
文摘This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.
基金supported by the National Basic Research Program of China(No.2007CB411606)
文摘Ultrasonic communication in vertebrates is attracting increasing research interest.To determine if ultrasonic vocalization is common in birds,we recorded their vocalizations with ultrasound detectors in the Dongzhai National Nature Reserve of Henan Province,China.We found varying degrees of high frequency components in the vocalizations of 14 species and in several of these species,the frequency of harmonics was up to the range of ultrasound.We suggest that more studies are required to determine whether the high frequency components in avian vocalizations have functions and what these functions are.In addition,the ability of birds to hear sounds in the high frequency range also requires re-examination.
基金supported by the National Natural Science Foundation of ChinaNo.81100922
文摘Nerve growth factor(NGF) plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound(HFU) is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.