A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and con...Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography (HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus) to microtubules is reported. It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis, and they were identified as the taxoids of taxol, baccatin III, 10-deacetylbaccatin Ⅲ(10-DAB), cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples, both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated. It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP. Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated.展开更多
A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o...A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.展开更多
Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is ...Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation.展开更多
Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatograph...Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH.展开更多
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri...Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.展开更多
A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chine...A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk.展开更多
[Objectives]To accurately determine the naringin content in Rhizoma Drynariae.[Methods]The high performance liquid chromatography(HPLC)method was applied in the determination of the naringin content in Rhizoma Drynari...[Objectives]To accurately determine the naringin content in Rhizoma Drynariae.[Methods]The high performance liquid chromatography(HPLC)method was applied in the determination of the naringin content in Rhizoma Drynariae.The sample was sonicated at room temperature.The mobile phase was 0.1%phosphoric acid-acetonitrile(75∶25),detected by diode array detector at the wavelength of 284 nm,and quantified by external standard method.[Results]The linearity of naringin was good in the concentration range of 5-500μg/mL with a correlation coefficient of 0.9999.[Conclusions]This method has good linearity,easy operation,correctness and reproducibility as required,and is expected to provide a method for the determination of naringin content in Rhizoma Drynariae.展开更多
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
基金the National Natural Science Foundation of China(No.90709021)Knowledge Innovation Program of Chi-nese Academy of Sciences(No.KJCX2.YW.HO9)
文摘Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography (HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus) to microtubules is reported. It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis, and they were identified as the taxoids of taxol, baccatin III, 10-deacetylbaccatin Ⅲ(10-DAB), cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples, both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated. It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP. Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated.
文摘A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.
文摘Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation.
文摘Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH.
基金Project supported by the National Natural Science Foundation of China (No.20437020)Major Research Program of Chinese Academy of Sciences (No.KZCX3-SW-432).
文摘Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.
基金Education Ministy Foundation for Chinese Returned Scholars and Nature Science Foundation of Hubeiprovince!98J054
文摘A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk.
文摘[Objectives]To accurately determine the naringin content in Rhizoma Drynariae.[Methods]The high performance liquid chromatography(HPLC)method was applied in the determination of the naringin content in Rhizoma Drynariae.The sample was sonicated at room temperature.The mobile phase was 0.1%phosphoric acid-acetonitrile(75∶25),detected by diode array detector at the wavelength of 284 nm,and quantified by external standard method.[Results]The linearity of naringin was good in the concentration range of 5-500μg/mL with a correlation coefficient of 0.9999.[Conclusions]This method has good linearity,easy operation,correctness and reproducibility as required,and is expected to provide a method for the determination of naringin content in Rhizoma Drynariae.