期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Design and Simulation of a Electrorheological(ER) Control High Voltage Power Supply
1
作者 ZHU Shi-sha HUANG He-qing BAI Quan 《International Journal of Plant Engineering and Management》 2009年第3期142-146,共5页
Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power ... Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power supply for engineering application was designed which reduced power wastage by adopting soft switch technology; lessened its volume to satisfy micromation when adopting the planar transformer and improved its response character- istic by choosing an assistant discharging circuit. Simultaneously, a simulation analysis has been carried out. As results, the output voltage of this high voltage power supply is 5 kV, and the voltage can be continuously regulated and the voltage ripple is only 0. 7 %, so the requirement of stability is also achieved. 展开更多
关键词 ER control high voltage power supply application design soft switch technology SIMULATION
下载PDF
A high stability high voltage power supply design for HEPS injection system 被引量:1
2
作者 Peng Liu Jinhui Chen Guanwen Wang 《Radiation Detection Technology and Methods》 CSCD 2021年第4期564-569,共6页
Purpose The high energy photon source(HEPS)uses the on-axial injection scheme.There are two designs in this injection scheme that are critical to the performance of the HEPS injection system.One is the strip line kick... Purpose The high energy photon source(HEPS)uses the on-axial injection scheme.There are two designs in this injection scheme that are critical to the performance of the HEPS injection system.One is the strip line kicker and another is the high voltage fast pulse power supply system.In the high voltage fast pulse power supply system,the design of high voltage power supply is very important.The output voltage stability of high voltage power supply directly affects the stability of the pulse amplitude of the injection system.Methods A high voltage power supply with high output voltage stability is designed in this paper,and the scheme is given.The correctness of the design scheme is verified by simulation experiments.Result A prototype is built for full test.The test results showed that the output voltage stability is lower than 58 ppm.The output voltage is 6.4 mV(f≤3 kHz)/113.2 mV(f>3 kHz).Conclusions The designed high voltage power supply can fully meet the requirements of the HEPS injection system. 展开更多
关键词 HEPS Injection system high stability voltage ripple high voltage power supply
原文传递
Experiment and Operation of a LHCD-35kV/2.8MW/1000s High-Voltage Power Supply on HT-7 Tokamak
3
作者 黄懿赟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第4期1383-1386,共4页
A -35 kV/2.8 MW/1000s high-voltage power supply (HVPS) for HT-7 superconducting tokamak has been built successfully. The HVPS is scheduled to run on a 2.45 GHz/1 MW lower hybrid current drive (LHCD) [1] system of HT-7... A -35 kV/2.8 MW/1000s high-voltage power supply (HVPS) for HT-7 superconducting tokamak has been built successfully. The HVPS is scheduled to run on a 2.45 GHz/1 MW lower hybrid current drive (LHCD) [1] system of HT-7 superconducting tokamak before the set-up of HT-7 superconducting tokamak in 2003. The HVPS has a series of advantages such as good steady and dynamic response, logical computer program controlling the HVPS without any fault, operational panel and experimental board for data acquisition, which both are grounded distinctively in a normative way to protect the main body of HVPS along with its attached equipments from dangers. Electric power cables and other control cables are disposed reasonably, to prevent signals from magnetic interference and ensure the precision of signal transfer.This paper involves the experiment and operation of a 35 kV/2.8 MW/1000s HVPS [2] for 2.45 GHz/1 MW LHCD system. The reliability and feasibility of the HVPS has been demonstrated in comparison with experimental results of original design and simulation data. 展开更多
关键词 TOKAMAK lower hybrid current drive high voltage power supply
下载PDF
The Design of PSM-Based ECRH Power Supply Control System 被引量:2
4
作者 Jian Zhang Xu Hao +1 位作者 Wei Wei Yiyun Huang 《Journal of Power and Energy Engineering》 2016年第4期91-102,共12页
Electron cyclotron resonance heating (ECRH) system is one of the most important Tokamak auxiliary heating methods. However, there are growing demands for ECRH system as the physical experiments progress which meanwhil... Electron cyclotron resonance heating (ECRH) system is one of the most important Tokamak auxiliary heating methods. However, there are growing demands for ECRH system as the physical experiments progress which meanwhile adds the difficulty of designing and building the control system of its power source. In this paper, the method of designing a control system based on Single Chip Microcomputer (SCM) and Field Programmable Gate Array (FPGA) is introduced according to its main requirements. The experimental results show that the control system in this paper achieves the conversion of different working modes, gets exact timing, and realizes the failure protection in 10us thus can be used in the ECRH system. 展开更多
关键词 ECRH PSM high voltage power supply Control System Field Programmable Gate Array (FPGA) Single Chip Microcomputer (SCM)
下载PDF
Experimental Investigation of the Effects of Various Plasma Actuator Configurations on Lift and Drag Coefficients of a Circular Cylinder Including the Effects of Electrodes 被引量:4
5
作者 Siavash TABATABAEIAN Masoud MIRZAEI +2 位作者 Asghar SADIGHZADEH Vahid DAMIDEH Abdollah SHADARAM 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2012年第3期311-324,共14页
In this paper, the effects of the existence of plasma actuator electrodes and also various configurations of the actuator for controlling the flow field around a circular cylinder are experimentally investigated. The ... In this paper, the effects of the existence of plasma actuator electrodes and also various configurations of the actuator for controlling the flow field around a circular cylinder are experimentally investigated. The cylinder is made of PVC (Polyvinyl Chloride) and considered as a dielectric barrier. Two electrodes are fiush-mounted on the surface of the cylinder and are connected to a DC high voltage power supply lbr generation of electrical discharge. Pressure distribution results show that the existence of the electrodes and also the plasma are able to change the pressure distribution around the cylinder and consequently the lili and drag coefficients. It is found that the effect of the existence of the electrodes is comparable with the effect of plasma actuator in con- trolling the flow field around the cylinder and this effect is not reported by other researchers. Eventually it is concluded that the existence of the electrodes or any extra obiects on the cylinder and also the existence of the plasma are capable of changing the flow field structure around the cylinder so that the behavior of the lift and drag coefficients of the cylinder will be changed significantly. 展开更多
关键词 plasma actuator DC high voltage power supply generalized glow regime flow control wind tunnel
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部